Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Advanced Components for Spaceborne Infrared Astronomy

Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.

Davidson, Arnold W.↗

The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

Agnes, P.↗

The critical role of soil moisture in compound hazards

Soil moisture regulates the exchange of energy, water, and carbon across land–vegetation–atmosphere interfaces. Extremes in soil moisture can amplify natural hazards through interactions with diverse Earth system processes. Despite its mechanistic importance, soil moisture remains underrepresented in hazard research and predictive frameworks. Here, in this study, we review our current understanding of the role of soil moisture in the evolution and onset of diverse compound hazards by synthesizing the latest findings from observational and modelling studies. We highlight key soil moisture mechanisms, including atmospheric feedbacks that amplify drought–heatwave–wildfire events, precipitation couplings that promote clustered storms, and threshold responses that drive vegetation die-offs, trigger landslides, and induce flooding. Persistent challenges in observational data, model representation and operational implementation have limited the integration of soil moisture into hazard early-warning systems. Addressing these gaps through advances in observations, data assimilation, and physics-based and data-driven modelling will enhance hazard prediction and preparedness in a rapidly changing world.

Li, Chuxuan [University of California, Los Angeles↗

Cross-plane Thermoelectric and Thermionic Transport across Au/ h -BN/Graphene Heterostructures

Here, the thermoelectric voltage generated at an atomically abrupt interface has not been studied exclusively because of the lack of established measurement tools and techniques. Atomically thin 2D materials provide an excellent platform for studying the thermoelectric transport at these interfaces. Here, we report a novel technique and device structure to probe the thermoelectric transport across Au/ h -BN/graphene heterostructures. An indium tin oxide (ITO) transparent electrical heater is patterned on top of this heterostructure, enabling Raman spectroscopy and thermometry to be obtained from the graphene top electrode in situ under device operating conditions. Here, an AC voltage V(ω) is applied to the ITO heater and the thermoelectric voltage across the Au/ h -BN/graphene heterostructure is measured at 2ω using a lock-in amplifier. We report the Seebeck coefficient for our thermoelectric structure to be –215 μV/K. The Au/graphene/ h -BN heterostructures enable us to explore thermoelectric and thermal transport on nanometer length scales in a regime of extremely short length scales. The thermoelectric voltage generated at the graphene/ h -BN interface is due to thermionic emission rather than bulk diffusive transport. As such, this should be thought of as an interfacial Seebeck coefficient rather than a Seebeck coefficient of the constituent materials.

42 ENGINEERING↗

III/V silicon hybrid laser based on a resonant Bragg structure

We demonstrate a laser tunable in intensity with gigahertz tuning speed based on a III/V reflective semiconductor optical amplifier (RSOA) coupled to a silicon photonic chip. The silicon chip contains a Bragg-based Fabry–Perot resonator to form a passive bandpass filter within its stopband to enable single-mode operation of the laser. We observe a side mode suppression ratio of 43 dB, linewidth of 790 kHz, and an optical output power of 1.65 mW around 1530 nm. We also investigate using a micro-ball lens as an alternative coupling method between the RSOA and the silicon chip.

Davis, Jordan A. (ORCID:0000000343483295)↗

On Forced RF Generation of CW Magnetrons for SRF Accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

43 PARTICLE ACCELERATORS↗

A Ferroelectric Fast Reactive Tuner for Superconducting Cavities

A prototype FerroElectric Fast Reactive Tuner (FE-FRT) for superconducting cavities has been developed, which allows the frequency to be controlled by application of a potential difference across a ferroelectric residing within the tuner. This technique has now become practically feasible due to the recent development of a new extremely low loss ferroelectric material. In a world first, CERN has tested the prototype FE-FRT with a superconducting cavity, and frequency tuning has been successfully demonstrated. This is a significant first step in the development of an entirely new class of tuner. These will allow electronic control of cavity frequencies, by a device operating at room temperature, within timescales that will allow active compensation of microphonics. For many applications this could eliminate the need to use over-coupled fundamental power couplers, thus significantly reducing RF amplifier power.

43 PARTICLE ACCELERATORS↗

Design and Implementation of a Digital Controller for a Vibration Isolation and Vernier Pointing System

This paper discusses the recommissioning of the Annular Suspension and Pointing System (ASPS), originally developed in the mid 1970's for pointing and vibration isolation of space experiments. The hardware was developed for NASA Langley Research Center by Sperry Flight Systems (now Honeywell Satellite Systems), was delivered to NASA in 1983. Recently, the hardware was loaned to Old Dominion University (ODU). The ASPS includes coarse gimbal assemblies and a Vernier Pointing Assembly (VPA) that utilize magnetic suspension to provide noncontacting vibration isolation and vernier pointing of the payload. The VPA is the main focus of this research. At ODU, the system has been modified such that it can now be operated in a l-g environment without a gravity offload. Suspension of the annular iron rotor in five degrees-of-freedom has been achieved with the use of modern switching power amplifiers and a digital controller implemented on a 486-class PC.

Neff, Daniel J.↗

WGM-Based Photonic Local Oscillators and Modulators

Photonic local oscillators and modulators that include whispering-gallery mode (WGM) optical resonators have been proposed as power-efficient devices for generating and detecting radiation at frequencies of the order of a terahertz. These devices are intended especially to satisfy anticipated needs for receivers capable of detecting lowpower, narrow-band terahertz signals to be used for sensing substances of interest in scientific and military applications. At present, available terahertz-signal detectors are power-inefficient and do not afford the spectral and amplitude resolution needed for detecting such signals. The proposed devices would not be designed according to the conventional approach of direct detection of terahertz radiation. Instead, terahertz radiation would first be up-converted into the optical domain, wherein signals could be processed efficiently by photonic means and detected by optical photodetectors, which are more efficient than are photodetectors used in conventional direct detection of terahertz radiation. The photonic devices used to effect the up-conversion would include a tunable optical local oscillator and a novel electro-optical modulator. A local oscillator according to the proposal would be a WGM-based modelocked laser operating at a desired pulserepetition rate of the order of a terahertz. The oscillator would include a terahertz optical filter based on a WGM microresonator, a fiber-optic delay line, an optical amplifier (which could be either a semiconductor optical amplifier or an erbium-doped optical fiberamplifier), and a WGM Ka-band modulator. The terahertz repetition rate would be obtained through harmonic mode locking: for example, by modulating the light at a frequency of 33 GHz and locking each 33d optical mode, one would create a 1.089-THz pulse train. The high resonance quality factors (Q values) of WGM optical resonators should make it possible to decrease signal-generation threshold power levels significantly below those of other optical-signal-generation devices.

Matsko, Andrey↗

EHW Approach to Temperature Compensation of Electronics

Efforts are under way to apply the concept of evolvable hardware (EHW) to compensate for variations, with temperature, in the operational characteristics of electronic circuits. To maintain the required functionality of a given circuit at a temperature above or below the nominal operating temperature for which the circuit was originally designed, a new circuit would be evolved; moreover, to obtain the required functionality over a very wide temperature range, there would be evolved a number of circuits, each of which would satisfy the performance requirements over a small part of the total temperature range. The basic concepts and some specific implementations of EHW were described in a number of previous NASA Tech Briefs articles, namely, "Reconfigurable Arrays of Transistors for Evolvable Hardware" (NPO-20078), Vol. 25, No. 2 (February 2001), page 36; Evolutionary Automated Synthesis of Electronic Circuits (NPO- 20535), Vol. 26, No. 7 (July 2002), page 37; "Designing Reconfigurable Antennas Through Hardware Evolution" (NPO-20666), Vol. 26, No. 7 (July 2002), page 38; "Morphing in Evolutionary Synthesis of Electronic Circuits" (NPO-20837), Vol. 26, No. 8 (August 2002), page 31; "Mixtrinsic Evolutionary Synthesis of Electronic Circuits" (NPO-20773) Vol. 26, No. 8 (August 2002), page 32; and "Synthesis of Fuzzy-Logic Circuits in Evolvable Hardware" (NPO-21095) Vol. 26, No. 11 (November 2002), page 38. To recapitulate from the cited prior articles: EHW is characterized as evolutionary in a quasi-genetic sense. The essence of EHW is to construct and test a sequence of populations of circuits that function as incrementally better solutions of a given design problem through the selective, repetitive connection and/or disconnection of capacitors, transistors, amplifiers, inverters, and/or other circuit building blocks. The connection and disconnection can be effected by use of field-programmable transistor arrays (FPTAs). The evolution is guided by a search-andoptimization algorithm (in particular, a genetic algorithm) that operates in the space of possible circuits to find a circuit that exhibits an acceptably close approximation of the desired functionality. The evolved circuits can be tested by mathematical modeling (that is, computational simulation) only, tested in real hardware, or tested in combinations of computational simulation and real hardware.

Stoica, Adrian↗

Metasurface quantum-cascade laser with electrically switchable polarization

Dynamic control of a laser’s output polarization state is desirable for applications in polarization sensitive imaging, spectroscopy, and ellipsometry. Using external elements to control the polarization state is a common approach. Less common and more challenging is directly switching the polarization state of a laser, which, however, has the potential to provide high switching speeds, compactness, and power efficiency. Here, we demonstrate a new approach to achieve direct and electrically controlled polarization switching of a semiconductor laser. This is enabled by integrating a polarization-sensitive metasurface with a semiconductor gain medium to selectively amplify a cavity mode with the designed polarization state, therefore leading to an output in the designed polarization. Here, the demonstration is for a terahertz quantum-cascade laser, which exhibits electrically controlled switching between two linear polarizations separated by 80°, while maintaining an excellent beam with a narrow divergence of ~3°×3° and a single-mode operation fixed at ~3.4 THz, combined with a peak power as high as 93 mW at a temperature of 77 K. The polarization-sensitive metasurface is composed of two interleaved arrays of surface-emitting antennas, all of which are loaded with quantum-cascade gain materials. Each array is designed to resonantly interact with one specific polarization; when electrical bias is selectively applied to the gain material in one array, selective amplification of one polarization occurs. The amplifying metasurface is used along with an output coupler reflector to build a vertical-external-cavity surface-emitting laser whose output polarization state can be switched solely electrically. In conclusion, this work demonstrates the potential of exploiting amplifying polarization-sensitive metasurfaces to create lasers with desirable polarization states—a concept which is applicable beyond the terahertz and can potentially be applied to shorter wavelengths.

47 OTHER INSTRUMENTATION↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Peroxy radical measurements with NCAR's chemical amplifier

The present NCAR instrument for HO2/RO2 measurements has been described previously. It is based on the reactions involving HO2, RO2, and HO radicals with CO and NO. Since (HO2) + (RO2) + (HO) is much greater than (HO) for most atmospheres, it is useful as a peroxy radical detector. Operation of the instrument depends on the creation of a chemical chain reaction which is initiated as HO2 and RO2 radicals in ambient air encounter added NO gas; this forms an NO2 molecule and an HO or RO radical: HO2(RO2) + NO yields HO(RO) + NO2. RO radicals react relatively efficiently with O2 to form an HO2 radical, and subsequently an HO-radical, by reaction with NO. CO gas added to the reaction chamber during part of the operating cycle, recycles the HO to HO2; HO + CO (+O2) yields HO2 + CO2. The reaction sequence may form several hundred NO2 molecules per HO2 (RO2) originally present, before chain termination occurs. The added CO is replaced by N2 addition periodically so that the chain reaction is suppressed, and a 'blank' signal resulting from NO2, O3 and possibly other NO2-forming species (non-chain processes) in ambient air is recorded. The difference between the signal with and without CO is proportional to the peroxy radical concentration. The NO2 produced is monitored using a sensitive luminol chemiluminescence detector system. In the NCAR instrument the length of the amplification chain is determined using a stable source of HO2 radicals (H2O2 thermal decomposition); the ratio of the signal seen with CO present to that with N2 present gives the sensitivity of the instrument to HO2 (molecules of NO2 formed/peroxy radical). The instrument is automated to carry out in hourly repeated cycles: (1) chain length determination; (2) NO2 calibration; and (3) linearity check on the response of signals. One minute averages of signals are normally recorded. The sensitivity of the instrument to detect peroxy radicals is in the pptv range. The present instrument has operated continuously (24 hr/day) in the field studies which extended over a period of several weeks. The major advantages of this instrument are as follows: (1) its relative simplicity; (2) low power requirements; and (3) its rapid response to all types of peroxy radicals--HO2, CH3O2 and the higher alkyl and acyl peroxy radicals; however not all RO2 species generate HO2 radicals with perfect efficiency and hence have somewhat lower response/molecule than HO2 radicals.

Cantrell, Christopher↗

Use of an Ultrasonic/Sonic Driller/Corer to Obtain Sample Powder for CHEMIN, a Combined XRD/XRF Instrument

A miniature CHEMIN XRD/XRF (X-Ray Diffraction/X-Ray Fluourescence) instrument is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed in order to enable XRD analysis on an extraterrestrial body is how best to obtain a representative sample powder for analysis. For XRD powder diffraction analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a 2-dimensional detector as used in the CHEMIN instrument will produce good results with poorly prepared powders, the quality of the data will improve if the sample is fine-grained and randomly oriented. An Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL is an effective mechanism of sampling rock to produce cores and powdered cuttings. It requires low axial load (< 5N) and thus offers significant advantages for operation from lightweight platforms and in low gravity environments. The USDC is lightweight (<0.5kg), and can be driven at low power (<5W) using duty cycling. It consists of an actuator with a piezoelectric stack, ultrasonic horn, free-mass, and drill bit. The stack is driven with a 20 kHz AC voltage at resonance. The strain generated by the piezoelectric is amplified by the horn by a factor of up to 10 times the displacement amplitude. The tip impacts the free-mass and drives it into the drill bit in a hammering action. The free-mass rebounds to interact with the horn tip leading to a cyclic rebound at frequencies in the range of 60-1000 Hz. It does not require lubricants, drilling fluid or bit sharpening and it has the potential to operate at high and low temperatures using a suitable choice of piezoelectric material. To assess whether the powder from an ultrasonic drill would be adequate for analyses by an XRD/XRF spectrometer such as CHEMIN, powders obtained from the JPL ultrasonic drill were analyzed and the results were compared to carefully prepared powders obtained using a laboratory bench scale Retsch mill.

Chipera, S. J.↗

First results of the 2.45 GHz Oshima electron cyclotron resonance ion source

A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.

43 PARTICLE ACCELERATORS↗

On forced RF generation of CW magnetrons for accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a quite large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for stabilization of magnetrons. In this case CW magnetrons with the injection-locked oscillations generate a high level of noise. This may preclude use of standard CW magnetrons in this operating mode in the Superconducting RF (SRF) accelerators. In this article we described a method developed for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The method is most suitable for powering high Q-factor cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗