Search NASASearch

SEARCH · Search NASA

Results for “electroweak interactions in nuclear physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,865 records · Page 63

Cation valency in water-in-salt electrolytes alters the short- and long-range structure of the electrical double layer

Highly concentrated aqueous electrolytes (termed water-in-salt electrolytes, WiSEs) at solid-liquid interfaces are ubiquitous in myriad applications including biological signaling, electrosynthesis, and energy storage. This interface, known as the electrical double layer (EDL), has a different structure in WiSEs than in dilute electrolytes. Here, we investigate how divalent salts [zinc bis(trifluoromethylsulfonyl)imide, Zn(TFSI) 2 ], as well as mixtures of mono- and divalent salts [lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) mixed with Zn(TFSI) 2 ], affect the short- and long-range structure of the EDL under confinement using a multimodal combination of scattering, spectroscopy, and surface forces measurements. Raman spectroscopy of bulk electrolytes suggests that the cation is closely associated with the anion regardless of valency. Wide-angle X-ray scattering reveals that all bulk electrolytes form ion clusters; however, the clusters are suppressed with increasing concentration of the divalent ion. To probe the EDL under confinement, we use a Surface Forces Apparatus and demonstrate that the thickness of the adsorbed layer of ions at the interface grows with increasing divalent ion concentration. Multiple interfacial layers form following this adlayer; their thicknesses appear dependent on anion size, rather than cation. Importantly, all electrolytes exhibit very long electrostatic decay lengths that are insensitive to valency. It is likely that in the WiSE regime, electrostatic screening is mediated by the formation of ion clusters rather than individual well-solvated ions. This work contributes to understanding the structure and charge-neutralization mechanism in this class of electrolytes and the interfacial behavior of mixed-electrolyte systems encountered in electrochemistry and biology.

Science & Technology - Other Topics

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

SMM parallel battery operation in orbit

A parallel battery system for the SMM spacecraft is described. The battery system performance as a function of lifetime over orbit was evaluated. The following equipment performance specifications were examined during a typical orbit: battery current and discharges, voltage limitations, battery temperature variations, and current sensor performance. Tabulated battery performance data is also included.

Broderick, R.

In-Orbit Earth Radiation Budget Satellite (ERBS) Battery Switch

A viewgraph presentation outlines the Earth Radiation Budget Satellite (ERBS) power system and battery history. ERBS spacecraft and battery cell failures are listed with the reasons for failure. The battery management decision and stabilization of the batteries is discussed. Present battery operations are shown to be successful.

Ahmad, Anisa

The Study of Dopant Segregation Behavior During the Growth of GaAs in Microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

D H Matthiesen

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Tetrel Bond-Mediated Photophysical Modulation and Fluoride Recognition in Carbazole-Organosilanes

Silicon-centered orbitals are typically regarded as electronically inert in donor–acceptor systems. Here, we show that silole-based carbazole–silane architectures can render these orbitals electronically relevant, enabling modulation of excited-state behavior and anion-responsive photophysics. Two carbazole–Dipp–silanes exhibit identical carbazole-localized LE singlet emission in solution yet diverge markedly in the solid state: one compound displays a broad long-wavelength emission band in the prompt spectrum and enhanced long-lived emission consistent with a triplet-derived excited state, likely arising from a combination of intramolecular structural locking and solid-state packing effects, whereas the more flexible analogue remains predominantly LE-emissive. Fluoride coordination further differentiates the two systems, producing ratiometric red-shifted emission in one case and fluorescence quenching in the other through a fully reversible coordination process. These results identify σ*(Si–Ar) orbitals as tunable contributors to excited-state landscapes in organosilane luminophores and suggest a broader design strategy for controlling excited-state behavior in tetrel-based photofunctional systems.

Haque, Md Hasanul

Pinned in Microgravity: How Colloidal Suspensions Inhibit Droplet Motion

Understanding the fundamental behavior of colloidal fluids in microgravity is critical for advancing material science, manufacturing, and biological processes. In this study we investigate the dynamics of a droplet containing colloidal suspension when ejected in short term microgravity. These conditions are generated using a 2.2 second drop tower. A custom droplet generator was designed to produce consistent size-controlled droplets containing passive colloidal particles. The particles are suspended in water and subsequently ejected out of a hydrophobic wedge under microgravity conditions, where the droplet ejection time can be predicted [Torres & Weislogel, 2021]. The ejection times will be compared with de-ionized water ejected from the same system to investigate the effects of change in density and surface tension caused by the colloids. Successful passive colloidal ejection will lay the foundation for active colloid research in the future.

colloids

Evidence for Multiple Diagenetic Episodes in Ancient Fluvial‐Lacustrine Sedimentary Rocks in Gale Crater, Mars

The Curiosity rover's exploration of rocks and soils in Gale crater has provided diverse geochemical and mineralogical data sets, underscoring the complex geological history of the region. We report the crystalline, clay mineral, and amorphous phase distributions of four Gale crater rocks from an 80‐m stratigraphic interval. The mineralogy of the four samples is strongly influenced by aqueous alteration processes, including variations in water chemistries, redox, pH, and temperature. Localized hydrothermal events are evidenced by gray hematite and maturation of amorphous SiO 2 to opal‐CT. Low‐temperature diagenetic events are associated with fluctuating lake levels, evaporative events, and ground water infiltration. Among all mudstones analyzed in Gale crater, the diversity in diagenetic processes is primarily captured by the mineralogy and X‐ray amorphous chemistry of the drilled rocks. Variations indicate a transition from magnetite to hematite and an increase in matrix‐associated sulfates suggesting intensifying influence from oxic, diagenetic fluids up section. Furthermore, diagenetic fluid pathways are shown to be strongly affected by unconformities and sedimentary transitions, as evidenced by the intensity of alteration inferred from the mineralogy of sediments sampled adjacent to stratigraphic contacts.

C N Achilles

Chemo‐Mechanical Coupling in Hydrogels: Dynamics in the Diffusion‐Limited Regime

Hydrogels are characterized by substantial volume changes in response to external stimuli, making them promising candidates for developing smart materials with enhanced adaptability and responsiveness. By integrating chemical reactions, hydrogels acquire dynamic and tunable responsiveness to external stimuli through chemo‐mechanical coupling, expanding their potential in emerging applications. However, capturing their transient behavior remains challenging due to the complex interplay of chemical reactions, solvent transport, and polymer network deformation. Classical theories capture equilibrium swelling but fail to describe time‐dependent phenomena. To address this, a time‐dependent continuum model is developed that explicitly couples these processes. Volume phase transition in hydrogels with homogeneous chemical reactions is investigated, then the effects of reaction kinetics on these transitions are analyzed. The coupling of these mechanisms is further explored through a study of transient mechanical instabilities. To illustrate the impact of distinct reaction and diffusion timescales, a photo‐active gripper is studied for robotic applications. Finally, a photo‐active microswimmer that exhibits non‐reciprocal motion is proposed to highlight the solvent diffusion for locomotion at the micro‐ and nano‐ scales. The work establishes that transient dynamics of chemo‐mechanical hydrogels generate functions not accessible by steady state models and provides a predictive platform for designing adaptive materials in emerging applications.

chemo-mechanical coupling

Revealing the Roles of CuF 2 /NiF 2 Incorporation in the Electrochemical Performance of FeF 3 Cathodes in Solid‐State Batteries

Mixed metal fluorides have been considered as a promising candidate to lower the voltage hysteresis of conversion-type iron fluoride cathodes, but their cycling stability is limited due to transition metal dissolution and interphase growth in liquid electrolyte batteries. Here, we study the role of incorporating CuF 2 and NiF 2 in the electrochemical performance of FeF 3 cathode in halide-based solid-state batteries to test whether we can transfer the kinetic benefit of low voltage hysteresis to solid-state batteries while using solid electrolyte to eliminate transition metal dissolution and stabilize the interphase. Synchrotron X-ray absorption spectroscopy results indicated the redox reactions are attributed to Cu 0 /Cu + and Fe 0 /Fe 2+ in 25CuF 2 -75FeF 3 and Ni 0 /Ni 2+ and Fe 0 /Fe 3+ in 10NiF 2 -90FeF 3 . While no apparent improvement in electrode kinetics can be observed, the incorporation of CuF 2 and NiF 2 can largely improve the cycling stability of FeF 3 cathodes. In conclusion, the results demonstrate the advantages of using solid-state concept to improve the cycling stability of conversion-type cathodes.

25 ENERGY STORAGE

Dirac Fermions and Flat Bands in Phosphorus Carbide Nanotubes: Structural and Quantum Phase Transitions in a Quasi-One-Dimensional Material

Chemically realistic quasi-one-dimensional (1D) materials in which Dirac Fermions and highly degenerate flat bands coexist intrinsically at the Fermi level are exceedingly rare, while representing a highly desirable platform for correlated and topological quantum phenomena. Here, in this work, using specialized symmetry-adapted first-principles calculations we predict a new class of nanomaterials─phosphorus carbide nanotubes (P 2 C 3 NTs)─obtained by rolling monolayer P 2 C 3 , a two-dimensional material shown in a previous letter to host “double Kagome bands”. Both armchair and zigzag P 2 C 3 NTs are stable at room temperature and feature the rare coexistence of Dirac crossings and multiple flat bands at the Fermi level inherited from the underlying honeycomb–Kagome lattice, with the flat bands resilient to elastic deformations. Under large strain, the structure transforms from honeycomb–Kagome to “brick-wall”, accompanied by multiple coupled structural and quantum phase transitions. We also uncover localized edge states, spin splitting from vacancies and dopants, and strain-tunable magnetism. Together, these results establish P 2 C 3 NTs as a chemically specific and mechanically tunable 1D material platform with potential applications in quantum hardware and spintronics.

carbon nanotubes

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record

Impact of Inertia, Friction, and Backlash upon Force Control in Telemanipulation

The mechanical behavior of master controllers of telemanipulators has been a concern of both designers and implementors of telerobotic systems. In general, the literature recommends that telemanipulator systems be constructed that minimize inertia, friction, and backlash in an effort to improve telemanipulative performance. For the most part, these recommendations are founded upon theoretical analysis or simply intuition. Although these recommendations are not challenged on their merit, the material results are measured of building and fielding telemanipulators that possess less than ideal mechanical behaviors. Experiments are described in which forces in a mechanical system with human input are evaluated as a function of mechanical characteristics such as inertia, friction, and backlash. Results indicate that the ability of the human to maintain gripping forces was relatively unaffected by dynamic characteristics in the range studied, suggesting that telemanipulator design in this range should be based on task level force control requirements rather than human factors.

Neil A Duffie