Search NASA⌕ Search

SEARCH · Search NASA

Results for “secure data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

DER Cybersecurity Detection and Response Suite

SAND2024-08475O The Distributed Energy Resource (DER) Cybersecurity Detection and Response Suite is a solution for distributed energy resource (DER) systems. The DER Security Orchestration, Automation, and Response (SOAR) solution that uses alerts from signature- and behavior-based Intrusion Detection Systems are intended to be deployed as bump-in-the-wire (BITW) devices in front of DER equipment. The fielded application would use multiple intrusion detection systems that report data to SOAR to respond to cyberattacks. The suite consists of two software components: • The proactive intrusion detection and mitigation system (PIDMS) secures grid-edge photovoltaic smart inverters and other equipment in distributed energy resource systems. It is a distributed BITW solution; cyber and physical data are automatically processed using network inspection tools and custom machine learning algorithms to detect abnormal events and correlate cyber-physical events. • The Security Orchestration, Automation, and Response for Distributed Energy Resources (SOAR4DER) application ingests data from several intrusion detection systems to quickly block attacks and revert DER systems to good states. Using a collection of intrusion detection system technologies on a BITW device, it incorporates physical and cyber data to detect abnormal and potential malicious behaviors. Multiple SOAR playbooks then use the intrusion detection system data streams to automatically defend the system. SOAR4DER system testing showed detection and response times under 30 seconds for all adversary reconnaissance, denial-of-service attacks, malicious Modbus commands, brute-force logins, and machine-in-the-middle attacks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗

A Privacy First Path Analysis using Clickstream Data

In the modern digital economy, data-driven decision making is crucial for effectively meeting the ever-evolving demands of consumer engagement and satisfaction. Clickstream data has become invaluable for understanding customer behavior, yet concerns over privacy and security persist, especially with some internet service providers profiting from its sale. This article introduces an innovative methodology that blends experiential learning with advanced cryptographic techniques, including differential privacy and graph analytics. The core objective of this methodology is to estimate Customer Lifetime Value (CLV) by analyzing clickstream data, achieving an average prediction accuracy of 92.4% in user engagement levels while ensuring user anonymity through Recency, Frequency, and Monetary (RFM) analysis. Our study introduces the concept of a “data depositor” and a privacy manager, employing the composition theorem to merge non-adaptive queries effectively. Privacy budgets (? = 1.0, d = 10-5), sensitivity-specific techniques, and data partitioning were applied. Randomization and noise addition protect data integrity, with special handling for categorical values. This approach, differing from prior studies, offers a 12.6% improvement in privacy-preserving targeting accuracy while maintaining strict confidentiality, presenting a novel path forward in data-driven decision-making.

Frequency and Monetary (RFM) analysis↗

Late Breaking Results: COPPER: Computation Obfuscation by Producing Permutations for Encoding Randomly

Deployed embedded devices face security risks due to increased ease of physical access to the devices by unauthorized users. Capable adversaries can intercept a device to recover the data in memory, including results of performed sensitive computations. Device owners require data confidentiality on their physically insecure devices. To satisfy this goal we implement a novel method, COPPER (Computation Obfuscation by Producing Permutations for Encoding Randomly), to create data which never exists on the device digitally in plaintext format and which is subsequently used for computation. In this paper we utilize COPPER to calculate a moving average computation on encoded data.

embedded systems↗

OCGen Module Mooring Project

Ocean Renewable Power Company's OCGen Module Mooring Project provided an extensive research, design, development, testing and data collection effort and analysis conducted with respect to a positively buoyant, submerged MHK device secured to the seabed using a tensioned mooring system. Different analytic tools were evaluated for their utility in the design of submerged systems and their moorings. Deployment and testing of a prototype OCGen® system provided significant data related to mooring line loads and system attitude and station keeping. Mooring line loads were measured in situ and reported against flow speeds. The Project made a significant step in the development of designs, methodologies and practices related to floating and mooring of marine hydrokinetic (MHK) devices. Importantly for Ocean Renewable Power Company, the Project provided a sound basis for advancing a technically and commercially viable OCGen® Power System. The OCGen® Power System is unique in the MHK industry and, in itself, offers distinct advantages of MHK devices that are secured to the seabed using fixed structural frames. Foremost among these advantages are capital and operating cost reductions and increased power extraction by allowing the device to be placed at the most energetic level of the water column.

16 TIDAL AND WAVE POWER↗

Economical Ground Data Delivery

Data delivery in the Deep Space Network (DSN) involves transmission of a small amount of constant, high-priority traffic and a large amount of bursty, low-priority data. The bursty traffic may be initially buffered and then metered back slowly as bandwidth becomes available. Today both types of data are transmitted over dedicated leased circuits. The authors investigated the potential of saving money by designing a hybrid communucations architecture that uses leased circuits for high-priority network communications and dial-up circuits for low-priority traffic. The architecture presented here may also be applied to any ground station-to-customer network within the range of a common carrier. The authors compare estimated costs for various scenerios and suggest security safeguards that should be considered.

communications↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

Centers for Disease Control and Prevention (CDC) Radiation Hazard Scale (Expanded Data Product Feedback Report)

During radiation emergencies, it is important to communicate clearly as radiation risks are often unfamiliar to many members of the general public and emergency responders, including public health workers. To partially address this issue, the Centers for Disease Control and Prevention (CDC) developed the Radiation Hazard Scale to communicate radiation risk to the general public, community leaders, and decision makers. The simple numeric scale does not require a background in radiation physics or health effects and can be used to assist people in understanding their risk and motivate protective action compliance. Lawrence Livermore National Laboratory has assisted the US Department of Energy National Nuclear Security Administration and the CDC in the development of Radiation Hazard Scale data products. This report documents the feedback received from Federal response officials on an expanded data product set. This expanded set accounts for the effects of building protection on radiation exposure and allows for the comparison between different response actions, including sheltering in place, based on the LLNL developed Regional Shelter Analysis methodology.

54 ENVIRONMENTAL SCIENCES↗

Modernization of the Cassini Ground System

The Cassini Spacecraft and its ground system have been operational for over 16 years. Modernization presents several challenges due to the personnel, processes, and tools already invested and embedded into the current ground system structure. Every mission's ground system has its own unique complexities and challenges, involving various organizational units. As any mission from its inception to its execution, schedules are always tight. This forces GDS engineers to implement a working ground system that is not necessarily fully optimized. Ground system challenges increase as technology evolves and cyber threats become more sophisticated. Cassini's main challenges were due to its ground system existing before many security requirements were levied on the multi-mission tools and networks. This caused a domino effect on Cassini GDS tools that relied on outdated technological features. In the aerospace industry reliable and established technology is preferred over innovative yet less proven technology. Loss of data for a spacecraft mission can be catastrophic; therefore, there is a reluctance to make changes and updates to the ground system. Nevertheless, all missions and associated teams face the need to modernize their processes and tools. Systems development methods from well-known system analysis and design principles can be applied to many missions' ground systems. Modernization should always be considered, but should be done in such a way that it does not affect flexibility nor interfere with established practices. Cassini has accomplished a secure and efficient ground data system through periodic updates. The obstacles faced while performing the modernization of the Cassini ground system will be outlined, as well as the advantages and challenges that were encountered.

Razo, Gus↗

Modernization of the Cassini Ground System

The Cassini Spacecraft and its ground system have been operational for over 16 years. Modernization presents several challenges due to the personnel, processes, and tools already invested and embedded into the current ground system structure. Every mission's ground system has its own unique complexities and challenges, involving various organizational units. As any mission from its inception to its execution, schedules are always tight. This forces GDS engineers to implement a working ground system that is not necessarily fully optimized. Ground system challenges increase as technology evolves and cyber threats become more sophisticated. Cassini's main challenges were due to its ground system existing before many security requirements were levied on the multi-mission tools and networks. This caused a domino effect on Cassini GDS tools that relied on outdated technological features. In the aerospace industry reliable and established technology is preferred over innovative yet less proven technology. Loss of data for a spacecraft mission can be catastrophic; therefore, there is a reluctance to make changes and updates to the ground system. Nevertheless, all missions and associated teams face the need to modernize their processes and tools. Systems development methods from well-known system analysis and design principles can be applied to many missions' ground systems. Modernization should always be considered, but should be done in such a way that it does not affect flexibility nor interfere with established practices. Cassini has accomplished a secure and efficient ground data system through periodic updates. The obstacles faced while performing the modernization of the Cassini ground system will be outlined, as well as the advantages and challenges that were encountered.

Razo, Gus↗

FERMI/GLAST Integrated Trending and Plotting System Release 5.0

An Integrated Trending and Plotting System (ITPS) is a trending, analysis, and plotting system used by space missions to determine performance and status of spacecraft and its instruments. ITPS supports several NASA mission operational control centers providing engineers, ground controllers, and scientists with access to the entire spacecraft telemetry data archive for the life of the mission, and includes a secure Web component for remote access. FERMI/GLAST ITPS Release 5.0 features include the option to display dates (yyyy/ddd) instead of orbit numbers along orbital Long-Term Trend (LTT) plot axis, the ability to save statistics from daily production plots as image files, and removal of redundant edit/create Input Definition File (IDF) screens. Other features are a fix to address invalid packet lengths, a change in naming convention of image files in order to use in script, the ability to save all ITPS plot images (from Windows or the Web) as GIF or PNG format, the ability to specify ymin and ymax on plots where previously only the desired range could be specified, Web interface capability to plot IDFs that contain out-oforder page and plot numbers, and a fix to change all default file names to show yyyydddhhmmss time stamps instead of hhmmssdddyyyy. A Web interface capability sorts files based on modification date (with newest one at top), and the statistics block can be displayed via a Web interface. Via the Web, users can graphically view the volume of telemetry data from each day contained in the ITPS archive in the Web digest. The ITPS could be also used in nonspace fields that need to plot data or trend data, including financial and banking systems, aviation and transportation systems, healthcare and educational systems, sales and marketing, and housing and construction.

Ritter, Sheila↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Probabilistic Voltage Risk Assessment of MiniWECC System with Uncertain PVs and Wind Generations using Realistic Data

Here, it is found from actual data that due to generation dispatch and uncertain renewable generations and loads with complicated correlations, inferring the probabilistic distributions for uncertain inputs is challenging. Many probabilistic power flow approaches have been developed in the literature but their validations using realistic systems and data are lacking. This paper proposes a data-driven probabilistic analysis approach for system risk assessment of the miniWECC system using actual data. The sparse Gaussian process (SGP) is advocated to quantify the impacts of uncertain inputs on voltage security. SGP does not need the probability distribution function of uncertain inputs, can handle correlations and is highly computationally efficient. Results on the miniWECC system using realistic data show that SGP outperforms existing approaches and is able to quantify the voltage violation risks.

17 WIND ENERGY↗

Enterprise Artificial Intelligence Strategy for Los Alamos National Laboratory

In the 1984 martial arts drama film, The Karate Kid, a young Daniel LaRusso is unexpectedly placed in an adversarial environment unable to eYectively adapt to a series of new threats and limitations. Fortunately for the main character, once placed under the tutelage of a Mr. Miyagi, he finds resiliency not through the adoption of new tools, but a re-focused set of fundamentals. Much in the same way that Daniel learns waxing on and buYing oY car wax by hand has rewards for Karate, LANL is choosing the harder path of self-hosting Large Language Models (LLMs) for enterprise use instead of only relying on buying access to a hosted AI service like Azure’s OpenAI Application Programming Interface (API). We also are not willing to wait for software-as-a-service (SAAS) AI services to meet us where we need to be from a FedRAMP accreditation standpoint. Our operations regularly depend on access at CUI, UCNI, ITAR and other FIPS-199 moderate-impact data levels and hosting our own services gives us the right security and compliance posture to be useful across the broad range of our work at LANL. With the rise in threats to critical infrastructure, cloud service providers (CSPs), and supply chain attacks from both state and non-state actors, we are not placing the bet that SAAS hosted AI services will be available when we need them. Should a major event occur, we do not want our staY and operations left without a pathway for us to fix the problem and resume the use of AI tools.

42 ENGINEERING↗

GPU-Based Static Data-Flow Analysis for Fast and Scalable Android App Vetting

Many popular vetting tools for Android applications use static code analysis techniques. In particular, Interprocedural Data-Flow Graph (IDFG) construction is the computation at the core of Android static data-flow analysis and consumes most of the analysis time. Many analysis tools use a worklist algorithm, an iterative fixed-point approach, to construct the IDFG. In this paper, we observe that a straightforward GPU parallelization of the worklist algorithm leads to significant underutilization of the GPU resources. We identify four performance bottlenecks, namely, frequent dynamic memory allocations, high branch divergence, workload imbalance, and irregular memory access patterns. Accordingly, we propose GDroid, a GPU-based worklist algorithm implementation with multiple fine-grained optimizations tailored to common characteristics of Android applications. The optimizations considered are: matrix-based data structure, memory access-based node grouping, and worklist merging. Our experimental evaluation, performed on 1000 Android applications, shows that the proposed optimizations are beneficial to performance, and GDroid can achieve up to 128X speedups against a plain GPU implementation.

Android security↗

Accessing Wi-Fi Data for Occupancy Sensing

A key issue for saving energy in buildings is to assure that delivery of energy services matches building occupancy as closely as possible, to assure that energy is not wasted providing the services to empty rooms or buildings, and to assure that needed services are provided during all times when desired. Accomplishing this to date has been significantly hampered by a lack of inexpensive mechanisms to obtain and use building-wide and more granular data about occupancy. In recent years, the concept of inferential (or implicit) sensing has been proposed and explored to use data from IT systems that already exists in most buildings, to obtain data that are not perfect, but are nearly free to obtain. Past work by LBNL and others has primarily demonstrated the principle and potential for this, with a primary focus on data from Wi-Fi networks as the best near-term opportunity for inferential sensing from IT networks. This is due to its near-ubiquity, ease of explanation to many audiences, relative uniformness in deployment, low latency of detection, clear ways to mitigate privacy and security, and other benefits (Price et al., 2015). While the potential and value are clear, researchers or building managers who want to obtain the data lack a source of information to understand what data might exist, what devices may have it, and what mechanisms are available to obtain the data. The purpose of this report is to fill that gap. The report begins with a review of institutional issues in collecting such data, including very real concerns about privacy and IT security. It then describes the various system architectures used in Wi-Fi systems in commercial buildings today, and a variety of mechanisms that can be used to obtain information from them, including examples of how to use them, and sample output. Next is a summary of how to use such data for several different purposes, from retrospective analysis to dynamic building operation, and a conclusion. An appendix provides additional detail on specific mechanisms available from major equipment manufacturers. The mechanisms specified in this report can be used by building owners and operators to confirm proper operation and uncover any issues or unexpected conditions as a resource for building owners and researchers interesting in utilizing inferential sensing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel capabilities for examining and summarizing hierarchical and geographic resiliency profiles

The geospatial research and development team in the National and Homeland Security Division at Idaho National Laboratory was tasked with providing tools to derive insight from the substantial amount of data currently available - and continuously being produced - associated with the critical infrastructure of the US. This effort is in support of the Department of Homeland Security, whose mission includes the protection of this infrastructure and the enhancement of its resilience to hazards, both natural and human. We present geovisual-analytics-based approaches for analysis of vulnerabilities and resilience of critical infrastructure, designed so that decision makers, analysts, and infrastructure owners and managers can manage risk, prepare for hazards, and direct resources before and after an incident that might result in an interruption in service. Our designs are based on iterative discussions with DHS leadership and analysts, who in turn will use these tools to explore and communicate data in partnership with utility providers, law enforcement, and emergency response and recovery organizations, among others. In most cases these partners desire summaries of large amounts of data, but increasingly, our users seek the additional capability of focusing on, for example, a specific infrastructure sector, a particular geographic region, or time period, or of examining data in a variety of generalization or aggregation levels. These needs align well with tenets of in-formation-visualization design; in this paper, selected applications among those that we have designed are described and positioned within geovisualization, geovisual analytical, and information visualization frameworks.

97 MATHEMATICS AND COMPUTING↗