Search NASASearch

SEARCH · Search NASA

Results for “thermal modeling techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,622 records · Page 63

Preparation of the Ice Certification of the Dornier 328 Regional Airliner By Numerical Simulation and By Ground Test

The Dornier 328, a new regional airliner, is to be qualified to FAR25/JAR25 requirements for operation into known icing conditions. All lifting surfaces are pneumatically deiced. Impingement limits were determined using a validated computational fluid dynamic (CFD) code. Wind tunnel tests with a model of the whole aircraft and the isolated empennage equipped with artificial ice shapes showed a degradation of handling characteristics due to ice accretion. Extensive two and three dimensional CFD calculations evaluated ice accretion at the deflection elevator horn. Icing tunnel tests were performed with a model of the horizontal tail with icing similitude fulfilled. The Dornier Do328 powerplant air induction system has successfully completed a program of icing tests in support of aircraft certification for operation into known icing conditions. Potential flight icing conditions were extensively analyzed using a CFD potential flow code and 3-D particle tracking routine to identify critical flight icing conditions. The tunnel test program verified the analytically predicted critical ice accretion surfaces of the air induction system, the adequacy of the ice protection provisions and demonstrated compliance with the applicable (JAR25) regulatory material.

D Welte

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

Realization of two-dimensional discrete time crystals with anisotropic Heisenberg coupling

A discrete time crystal (DTC) is an out-of-equilibrium phase of matter that spontaneously breaks discrete time-translation symmetry. Previous studies have been limited to a set of models with Ising-like couplings - and mostly only in one dimension - thus precluding our understanding of the existence (or not) of DTCs in models with more realistic interactions. In this work, by combining the latest generation of IBM quantum processors with state-of-the-art tensor network methods, we demonstrate the existence of a DTC in a two-dimensional system governed by anisotropic Heisenberg interactions. We uncover a rich phase diagram encompassing spin-glass, ergodic, and time-crystalline phases, and identify the interplay of initialization, interaction anisotropy, and driving protocols in stabilizing the DTC phase. By extending the study of Floquet matter beyond simplified models, we lay the groundwork for exploring how driven systems bridge the gap between quantum coherence and emergent non-equilibrium thermodynamics.

Phase transitions and critical phenomena

High-Temperature SiC Cladding End Plug Irradiation Design and HFIR Readiness

This report documents the design of a High Flux Isotope Reactor (HFIR) irradiation experiment intended to evaluate irradiation effects on the hermeticity of silicon carbide (SiC) end plug specimens under a radial fast neutron flux gradient at representative light-water reactor (LWR) temperatures of approximately 300 °C. The overarching goal of this work is to statistically evaluate SiC end plug hermeticity and mechanical properties following irradiation using the high-throughput irradiation capability discussed here. Each specimen consists of a short section of SiC fiber–reinforced SiC (SiC/SiC) tube with a single monolithic SiC end plug joined to one end. The experiment allows up to 66 specimens to be irradiated in six different stacks within a dry, sealed irradiation capsule derived from the previously developed high-temperature SiC/SiC cladding bowing experiment. The neutronics basis, thermal analysis, and HFIR readiness of the experiment are discussed in this report for two possible design cases. The first design case is based on existing approval documentation and components that are on hand and approved for use, so the experiment insertion would require only specimen receipt, specimen pre-irradiation characterization, experiment assembly, and final fabrication package approval. The second design case provides improved thermal robustness and the preferred end plug geometry but requires fabrication of a modified holder and revisions to the HFIR approval documentation, in addition to the other activities required for the first design case, before insertion.

Hott, Daniel [Oak Ridge National Laboratory (ORNL)

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

Aliberti, Gerardo

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

The Solid Surface Combustion Experiment Aboard the USML-1 Mission

AA Experimental results from the five experiments indicate that flame spread rate increases with increasing ambient oxygen content and pressure. An experiment was conducted aboard STS-50/USML-1 in the solid Surface Combustion Experiment (SSCE) hardware for flame spread over a thin cellulosic fuel in a quiescent oxidizer of 35% oxygen/65% nitrogen at 1.0 atm. pressure in microgravity. The USML-1 test was the fourth of five planned experiments for thin fuels, one performed during each of five Space Shuttle Orbiter flights. Data that were gathered include gas- and solid-phase temperatures and motion picture flame images. Observations of the flame are described and compared to theoretical predictions from steady and unsteady models that include flame radiation from CO2 and H2O. Experimental results from the five esperiments indicate that flame spread rate increases with increasing ambient oxygen content and pressure. The brightness of the flame and the visible soot radiation also increase with increasing spread rate. Steady-state numerical predictions of temperature and spread rate and flame structure trends compare well with experimental results near the flame's leading edge while gradual flame evolution is captured through the unsteady model.

Robert A Altenkirch

Observations of the microclimate of a lake under cold air advective conditions

The moderating effects of Lake Apopka, Florida, on downwind surface temperatures were evaluated under cold air advective conditions. Point temperature measurements north and south of the lake and data obtained from the NOAA satellite and a thermal scanner flown at 1.6 km, indicate that, under conditions of moderate winds (approximately 4m/sec), surface temperatures directly downwind may be higher than surrounding surface temperatures by as much as 5 C. With surface wind speed less than 1m/sec, no substantial temperature effects were observed. Results of this study are being used in land use planning, lake level control and in agriculture for selecting planting sites.

R. G., Jr. Bill

Update on Development of 360V, 28kWh Lithium-Ion Battery

Engineering unit submodule batteries (EUSB) the 360V, 28kWh EAPU battery were designed and assembled by COM DEV. These submodules consist of Sony Li-Ion 18650HC cells in a 5P-41S array yielding 180V, 1.4 kWh. Tests of these and of substrings and single cells at COM DEV and at JSC under various performance and abuse conditions demonstrated that performance requirements can be met. The thermal vacuum tests demonstrated that the worst case hot condition is the design driver. Deficiencies in the initial diode protection scheme of the battery were identified as a result of test failures. Potential solutions to the scheme are under development and will be presented.

Davies, Francis

Uncovering obscured phonon dynamics from powder inelastic neutron scattering using machine learning

The study of phonon dynamics is pivotal for understanding material properties, yet it faces challenges due to the irreversible information loss inherent in powder inelastic neutron scattering spectra and the limitations of traditional analysis methods. In this study, we present a machine learning framework designed to reveal obscured phonon dynamics from powder spectra. Using a variational autoencoder, we obtain a disentangled latent representation of spectra and successfully extract force constants for reconstructing phonon dispersions. Notably, our model demonstrates effective applicability to experimental data even when trained exclusively on physics-based simulations. The fine-tuning with experimental spectra further mitigates issues arising from domain shift. Analysis of latent space underscores the model’s versatility and generalizability, affirming its suitability for complex system applications. Furthermore, our framework’s two-stage design is promising for developing a universal pre-trained feature extractor. This approach has the potential to revolutionize neutron measurements of phonon dynamics, offering researchers a potent tool to decipher intricate spectra and gain valuable insights into the intrinsic physics of materials.

domain adaptation

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting

Alignments in the orientation of radio jets from AGN and their host galaxies

It is well established that active galactic nuclei (AGNs) play an important role in the evolution of galaxies. These AGNs can be linked to the accretion processes onto massive black holes and past merger events in their host galaxies, which may lead to different alignments of the jets with respect to the host galaxies. This paper presents a study of the position angle (PA) differences between radio and optical images of radio-AGNs based on the second data release (DR2) of the Low Frequency Array (LOFAR) Two-Meter Sky Survey (LoTSS), theKarl G. JanskyVery Large Array Faint Images of the Radio Sky at Twenty-Centimeters Survey (FIRST), the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys, and the Sloan Digital Sky Survey (SDSS). We assessed PA measurement biases in the data and classified the radio-AGNs based on the radio luminosity and infrared colour from the Wide-field Infrared Survey Explorer (WISE). This resulted in the largest sample of radio AGNs with reliable radio and optical PA measurements published to date, with a total of 3682 AGNs. The PA difference (dPA) distributions for the radio-AGN sample show a prominent minor-axis alignment tendency. Based on some simple assumptions, we simulated the projection effect to estimate the intrinsic jet-galaxy alignment. The observed dPA distribution can be well described by a two-component jet-alignment model in which one component is more aligned with the minor axis of the host galaxy than the other. The fitting results indicate that the jet alignment is dependent on radio luminosity and the shape of the host galaxies, with the jets being more likely to be aligned with the minor axis of the galaxy for lower radio luminosity and for optically more elongated radio-AGNs. The minor-axis alignment of the entire sample may suggest a coherent accretion model present in most AGN host galaxies, while a considerable number of luminous radio-AGNs with massive host galaxies might have undergone accretion – according to the chaotic model – or past merger events.

Astronomy & Astrophysics

Cryopump for Large Pulses of Hydrogen

A test involving a flow of hot hydrazine decomposition products at a rate of 13.6 g/s (0.03 lb/s) established the requirement to maintain pressure in an 11.9-m-(39 ft) diameter space chamber below 200 microns. The flow, 2/3 hydrogen and 1/3 nitrogen by volume, continued for several periods ranging from 3 to 15 min. The pressure requirement was necessary to minimize thermal effects of the gas on the test vehicle but was well beyond the capability of the existing facility pumps. Various methods of obtaining additional temporary jump capacity were considered. From these, the slugged-charcoal approach was selected as the quickest and least expensive method to implement.

B C Moore

Improved constraints on hematite refractive index for estimating climatic effects of dust aerosols

Abstract Uncertainty in desert dust composition poses a big challenge to understanding Earth’s climate across different epochs. Of particular concern is hematite, an iron-oxide mineral dominating the solar absorption by dust particles, for which current estimates of absorption capacity vary by over two orders of magnitude. Here, we show that laboratory measurements of dust composition, absorption, and scattering provide valuable constraints on the absorption potential of hematite, substantially narrowing its range of plausible values. The success of this constraint is supported by results from an atmospheric transport model compared with station-based measurements. Additionally, we identify substantial bias in simulating hematite abundance in dust aerosols with current soil mineralogy descriptions, underscoring the necessity for improved data sources. Encouragingly, the next-generation imaging spectroscopy remote sensing data hold promise for capturing the spatial variability of hematite. These insights have implications for enhancing dust modeling, thus contributing to efforts in climate change mitigation and adaptation.

Environmental Sciences & Ecology

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed