Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Ion-Atom Cold Collisions and Atomic Clocks

This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime.

Ion-Atom↗

Evaluation of Commercial-Off-The-Shelf (COTS) Electronics for Extreme Cold Environments

Deep space and Icy Moon missions (Titan, Enceladus, Ceres, Europa, & Ganymede) will need qualified extreme environment capable components for electronic systems located in extremities of their rovers and spacecraft. Commercial off the shelf (COTS) components would be advantageous to use for some aspects of such projects, given that they are easier to procure and offer a broad range of functionalities. Furthermore, theoretical and experimental data suggest that many COTS parts are capable of operation, and not just storage, at temperatures well beyond the manufacturer specified temperature limits. To help address the challenges presented at near cryogenic temperatures, a COTS selection knowledge base is being developed to estimate the performance of COTS components within cold environments. The knowledge base captures queries from a range of information sources such as cold functionality test results for part types and families, theoretical and experimental literature reviews and key findings are summarized here. In addition, a selection of components are planned to be examined for their performance to near cryogenic temperatures to generate a methodology for identification and verification of the COTS candidates. As the qualification of COTS parts for extreme environments can be very costly, this knowledge base can serve to reduce qualification time and cost by pre-selecting and limiting candidates.

Mojarradi, Mohammad↗

166 GHz Ice Scattering Signal in Cold-Season Precipitating Cloud Systems

Surface snowfall can be produced by a variety of forcing mechanisms that are accompanied by different in-cloud physical processes and microphysical composition. For instance, shallow cumuliform snowfall forced by marine cold air outbreaks shows distinct geographic and seasonal signatures and plays in important role in annual snowfall production in many regions worldwide. Coincident CloudSat-CALIPSO observations confirm that oceanic regions exhibiting frequent shallow cumuliform snow are typically composed of mixed-phase cloud and precipitation particles and display passive microwave brightness temperature behavior that is dominated by cloud liquid water emission, while combined Global Precipitation Measurement (GPM) radiometer and surface radar studies of intense shallow cumuliform events indicate significant ice particle scattering signals at the highest GPM radiometer frequencies. Passive microwave imager channels in the 37 to 89 GHz range have long been used to detect precipitation-sized ice particle scattering signatures in clouds. Dual polarization plays an important role in distinguishing between scattering signatures and other background variability. The GPM Microwave Imager (GMI) is the first satellite radiometer to possess dual-polarized channels at 166 GHz. These high-frequency channels are more susceptible to emission and attenuation by cloud liquid water and water vapor than lower-frequency channels, but are also more sensitive to ice scattering. This research studies the ice scattering information contained in the 166 GHz channels compared to the historically used 85/89 GHz channels on previous sensors. A 166 GHz scattering index (SI) will be developed to understand how its correlation with non-precipitating ice scattering at higher altitudes also affects the 166 GHz scattering signature in cold-season precipitating cloud systems. The 166 GHz SI will be used to possibly isolate precipitation scattering signature for different snowfall modes (shallow convective vs. deep stratiform). The supercooled liquid water affecting shallow convective systems and drastically reducing the scattering signal could be detected and quantified, providing additional information for convective snow detection and quantification in solid precipitation retrieval algorithms.

Lisa Milani↗

Simultaneous Orthogonal Imaging for Cold Flow Characterization of Additively Manufactured Injector Elements

Additively manufactured (AM) injectors have the potential to improve characteristic velocity (C*) performance beyond the 90-97% of theoretical C* performance seen by traditionally manufactured (TM) combustion device injectors. Maximized C* performance yields high overall combustion efficiency in all types of combustion devices, particularly liquid rocket engines (LREs) and rotating detonation rocket engines (RDREs). A high degree of propellant atomization and mixedness is required to achieve maximum C* performance and therefore high overall combustion efficiency. This study focused on measuring and comparing the performance of different novel AM injector elements over a broad range of operating conditions under high pressure, cold flow. As part of this work, a high pressure, cold flow experimental spray facility was designed to measure each element’s injector spray patterns under pressures ranging from 50 to 1000 psig and stiffness ratios from 0.5 to 2.0. Preliminary results are presented from orthogonal, simultaneous imaging comparing atomization and spray geometry between quad, trio, pentad, slotted, and triplet impingers in gas-liquid flow.

Ari D Goldman↗

A Cold Wet Mars: A Testable Hypothesis for Ancient Mars Ocean Freezing Point Depression Via Low Molecular Weight Organics

Mars exhibits widespread evidence of surface water in the distant past, but global modeling has had difficulty producing climatological conditions conducive to a wet surface. The hypothesis discussed here examines a different way of approaching the problem rather than focusing on climate, instead an examination of the nature of the surface liquid itself. Previous work has largely assumed that martian surface water was a brine analogous to terrestrial ocean water, but recent discoveries suggest that significant amounts of light organic compounds may have been present via abiogenic native production of light organics on Mars [1]. Light organics such as methanol and formaldehyde have an approximate order-of-magnitude greater freezing point depression than brine, potentially lowering the freezing point of martian surface fluids sufficiently to remain liquid even if the mean surface temperature is below zero Centigrade. As Mars evolved and the surface transitioned to the strongly oxidized conditions seen today, the light organics would have oxidized to carbon dioxide and may be a constituent of the atmosphere today. Considerable work must be done to constrain the freezing points of Mars-relevant organic/water and organic/salt/water mixtures, but this investigation might explain the presence of surface fluid on a cold early Mars – a cold, wet Mars as opposed to a warm, wet Mars. Additionally, this approach may work in conjunction with climatological modeling to better describe early conditions conducive which adequately explain observations. This hypothesis can be tested by examination of ancient fluid inclusions (either in situ or via Mars Sample Return) such as those commonly found in halite, preserving samples of ancient martian surface fluid.

M D Fries↗

SMAP Calibration Using Cold Sky Observations

Cold Sky Calibration is an important tool in the calibration of the SMAP radiometer. It is used to assess the absolute calibration and its temporal drift. We will present the results of 7 years of cold sky observations and the latest improvements they provide to the analysis of the SMAP radiometer calibration performances.

Emmanuel P Dinnat↗

Impacts of Cold Ionospheric Ions in Magnetic Reconnection at the Earth’s Magnetopause and Magnetotail

The Earth’s magnetosphere is filled by particles from two sources: the solar wind and the ionosphere. Ionospheric ions are initially cold and contain He+ and O+, in addition to to H+. Depending on their initial magnetic latitude and local time, and the state of the magnetosphere, they may contribute to the plasmasphere, the plasma sheet, the ring current, the warm plasma cloak etc. Depending on which path they follow in the magnetosphere, some of these ionospheric ions remain cold when they reach the two key reconnection regions: the Earth’s magnetopause and the plasma sheet in the tail. In this presentation, we will first review previous statistical works that quantify the number of cold/ionospheric ions near these two regions. Several works have attempted to quantify these populations, but they are inherently difficult to characterize due to their low energy, often below the spacecraft potential. We will also discuss the impacts they have on the magnetic reconnection process. Ionospheric ions mass-load the regions where reconnection takes place and change the characteristic Alfven speed, resulting in a smaller reconnection electric field. They also take a portion of the energy that is imparted to particles, affecting the energy budget of magnetic reconnection. Finally, they introduce new length and time scales, associated to their gyroradius and gyroperiod. We will discuss what are the implications of these impacts for the evolution of the magnetosphere – solar wind interactions.

Sergio Toledo Redondo↗

Observation of a Cold Air Outbreak using CrIS on S-NPP and its Comparison with MERRA-2 and ERA-5

A cold air outbreak (CAO) is an extreme weather phenomenon that has significant social and economic impacts over a large region of the midlatitudes. However, the dynamical mechanism governing the occurrence and evolution of CAO events, particularly the role of the stratosphere, is not well understood. Through an analysis of one extreme CAO episode that occurred on 27-31 January 2019 across much of the US Midwest, this presentation examines the thermodynamic structure and impact of stratospheric downward transport using single-field-view (SFOV) satellite products (with a spatial resolution of ~14 km at nadir) from the Cross-track Infrared Sounder (CrIS) onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite in conjunction with MERRA-2 and ERA5 reanalysis products. The results show that along the path of cold air transport, particularly near the coldest surface center, there exists a large enhancement of O 3 , deep tropopause folding, and significant downward transport of stratospheric dry air, and a warm center above the tropopause that can be observed directly using the brightness temperature (BT) observations from CrIS stratospheric sounding channels. This study provides some observational evidences from CrIS that confirm the impact of stratosphere on CAO through downward transport, and demonstrates the value of the SFOV retrieval products for CAO dynamic transport study and model evaluation.

Xiaozhen Xiong↗

Isolation, Characterization and Genetic Manipulation of Cold-Tolerant, Manganese-Oxidizing Pseudomonas sp. Strains

Manganese-oxidizing bacteria (MnOB) produce Mn oxide minerals that can be used by humans for bioremediation but the purpose for the bacterium is less clear. This study describes the isolation and characterization of cold-tolerant MnOB strains isolated from a compost pile in Morris, Minnesota, USA: Pseudomonas sp. MS-1 and DSV-1. The strains were preliminarily identified as members of species Pseudomonas psychrophila by 16S rRNA analysis and a multi-locus phylogenetic study using a database of 88 genomes from the Pseudomonas genus. However, the average nucleotide identity (ANI) between these strains and the P. psychrophila sp. CF149 type strain was less than 93%. Thus, the two strains are members of a novel species that diverged from P. psychrophila . DSV-1 and MS-1 are cold tolerant; both grow at 4C but grow faster at 24C. Unlike the mesophilic MnOB P. putida GB-1, both strains are capable of robustly oxidizing Mn at low temperatures. Both DSV-1 and MS-1 genomes contain homologs of several Mn oxidation genes found in P. putida GB-1 ( mnxG, mcoA, mnxS1, mnxS2 and mnxR ). Random mutagenesis by transposon insertion was successfully performed in both strains and identified genes involved in Mn oxidation that were similar to those found in P. putida GB-1. Our results show that MnOB can be isolated from compost, supporting a role for Mn oxidation in plant waste degradation. The novel isolates Pseudomonas spp. DSV-1 and MS-1 both can oxidize Mn at low temperature and likely employ similar mechanisms and regulation as P. putida GB-1.

manganese oxidation↗

A REALISTIC EXAMINATION OF COLD FUSION CLAIMS 24 YEARS LATER

On March 29, 1989, chemists Martin Fleischmann and Stanley Pons announced they had discovered an effect whose explanation was required to lie in the realm of nuclear reactions. Their claim, and those subsequent to it of roughly similar nature, became known as ‘cold fusion’. Research continues to this day on this effect, but what has become clear is that whatever it is, it is not a conventional fusion process. Thus the ‘cold fusion’ moniker is somewhat inappropriate and many current researchers in the field prefer the term “Low Energy Nuclear Reactions (LENR)”, although other terms have been coined for it as well. the results developed out of the LENR research do in fact show something is happening to produce signals which might be interpreted as supporting nuclear reactions (which is what encourages and sustains LENR researchers), but which can also be interpreted via a set of unique and interesting conventional processes. The focus of this document is to describe and address recent objections to such processes so that subsequent LENR research can be guided to develop information that will determine whether either set of explanations has merit. It is hoped that criteria delineated herein will aid the USDOE and other agencies in determining if LENR proposals are meritorious and worthy of support or not.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Condensation Risk of Mechanically Attached Roof Systems in Cold Climate Zones

A white roof, cool roof, is constructed to decrease thermal loads from solar radiation, therefore saving energy by decreasing the cooling demands. Unfortunately, cool roofs with mechanically attached membrane, have shown to have a higher risk of intermediate condensation in the materials below the membrane in certain climates (Ennis & Kehrer, 2011) and in comparisons with similar construction with a darker exterior surface (Bludau, Zirkelbach, & Kuenzel, 2009). As a consequence, questions have been raised regarding the sustainability and reliability of using cool roof membranes in Northern U.S. climate zones. A white roof surface reflects more of the incident solar radiation in comparisons with a dark surface, which makes a distinguished difference on the surface temperature of the roof. However, flat roofs with either a light or dark surface and if facing a clear sky, are constantly losing energy to the sky due to the exchange of infrared radiation. This phenomenon exists both during the night and the day. During the day, if the sun shines on the roof surface, the exchange of infrared radiation typically becomes insignificant. During nights and in cold climates, the temperature difference between the roof surface and the sky can deviate up to 20 C (Hagentoft, 2001) which could result in a very cold surface temperature compared to the ambient temperature. Further, a colder surface temperature of the roof increases the energy loss and the risk of condensation in the building materials below the membrane. In conclusion, both light and dark coated roof membranes are cooled by the infrared radiation exchange during the night, though a darker membrane is more heated by the solar radiation during the day, thus decreasing the risk of condensation. The phenomenon of night time cooling from the sky and the lack of solar gains during the day is not likely the exclusive problem concerning the risk of condensation in cool roofs with mechanically attached membranes. Roof systems with thermoplastic membranes are prone to be more effected by interior air intrusion into the roof construction; both due to the wind induced pressure differences and due to the flexibility and elasticity of the membrane (Molleti, Baskaran, Kalinger, & Beaulieu, 2011). Depending on the air permeability of the material underneath the membrane, wind forces increase the risk of fluttering (also referred as billowing) of the thermoplastic membrane. Expectably, the wind induced pressure differences creates a convective air flow into the construction i.e. Page 2 air intrusion. If the conditions are right, moisture from the exchanging air may condensate on surfaces with a temperature below dew-point. The definite path of convective airflows through the building envelope is usually very difficult to determine and therefore simplified models (K nzel, Zirkelbach, & Scfafaczek, 2011) help to estimate an additional moisture loads as a result of the air intrusion. The wind uplifting pressure in combination with wind gusts are important factors for a fluttering roof. Unfortunately, the effect from a fluctuating wind is difficult to estimate as this is a highly dynamic phenomenon and existing standards (ASTM, 2011a) only take into account a steady state approach i.e. there is no guidance or regulations on how to estimate the air intrusion rate. Obviously, a more detailed knowledge on the hygrothermal performance of mechanically attached cool roof system is requested; in consideration to varying surface colors, roof air tightness, climate zones and indoor moisture supply.

Pallin, Simon B↗

Summary Of Cold Crucible Vitrification Tests Results With Savannah River Site High Level Waste Surrogates

The cold crucible inductive melting (CCIM) technology successfully applied for vitrification of low- and intermediate-level waste (LILW) at SIA Radon, Russia, was tested to be implemented for vitrification of high-level waste (HLW) stored at Savannah River Site, USA. Mixtures of Sludge Batch 2 (SB2) and 4 (SB4) waste surrogates and borosilicate frits as slurries were vitrified in bench- (236 mm inner diameter) and full-scale (418 mm inner diameter) cold crucibles. Various process conditions were tested and major process variables were determined. Melts were poured into 10L canisters and cooled to room temperature in air or in heat-insulated boxes by a regime similar to Canister Centerline Cooling (CCC) used at DWPF. The products with waste loading from ~40 to ~65 wt.% were investigated in details. The products contained 40 to 55 wt.% waste oxides were predominantly amorphous; at higher waste loadings (WL) spinel structure phases and nepheline were present. Normalized release values for Li, B, Na, and Si determined by PCT procedure remain lower than those from EA glass at waste loadings of up to 60 wt.%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Empirical Profiling of Cold Hydrogen Plumes Formed from Venting Of LH2 Storage Vessels: Preprint

Liquid hydrogen (LH2) storage is a viable approach to assuring sufficient hydrogen capacity at commercial fuelling stations. Presently, LH2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH2 delivery process. The behaviour of cold hydrogen plumes has not been well-characterized because empirical field data is essentially non-existent. The NFPA 2 Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and CFD modellers, has identified the lack of understanding of hydrogen dispersion during LH2 venting of storage vessel as a critical gap for establishing safety distances at LH2 facilities, especially commercial hydrogen fuelling stations. To address this need, the NREL sensor laboratory, in collaboration with the NFPA 2 Safety Task Group developed the Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH2 storage tank venting. A prototype Analyzer was developed and field-deployed at an actual LH2 venting operation with critical findings that included: - H2 being detected as much as 2 m lower than the release point, which is not predicted by existing models - A small and inconsistent correlation between oxygen depletion and the hydrogen concentration - A negligible to non-existent correlation between in-situ temperature and the hydrogen concentration The Analyzer is currently being upgraded for enhanced metrological capabilities including improved real-time spatial and temporal profiling of the plume and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behaviour under different wind, humidity, and temperatures. This data will be shared with the NFPA 2 Safety Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

30 DIRECT ENERGY CONVERSION↗

Effects of Cold Temperature and Main Compressor Intercooling on Recuperator and Recompression Cycle Performance

<span>This study investigates the effects of cold supercritical CO2 (sCO2) temperatures, compressor inlet pressures, and main compressor intercooling on the efficiency and specific power of recompression sCO2 cycles. Reducing the cold sCO2 temperature increases the compressor inlet density, thus reducing required compression power and increasing cycle thermal efficiency. &nbsp;Similarly, main compressor intercooling improves the specific power of a recompression cycle, reducing sCO2 mass flow, cycle size and cost for a given power output, though it is also shown to lead to an internal pinch point in the low temperature recuperator. Strategies for remediation of internal pinch points for recuperators as well as for the main CO2 cooler and the flue gas cooler are discussed, and apply to recompression cycles for all sCO2 applications.&nbsp; Upfront consideration of these remediation strategies is essential to determine attainable sCO2 cycle operating conditions and component sizing requirements.</span>

White, Chuck↗

Conducting plastic cold plates

Cold plates are described herein. In one example, a cold plate can include a thermally conductive plastic forming a coolant channel that includes a heat spreader formed into the thermally conductive plastic and an exterior surface of the thermally conductive plastic with a coupling location to couple a heat pipe to the exterior surface of the thermally conductive plastic.

97 MATHEMATICS AND COMPUTING↗

Method for removal of a foulant from a carrier gas in a single vessel using recycled cold solids

A method for removal of a foulant from a carrier gas is disclosed. A solids conveyance device that spans a vessel and a solids coolant system are provided. A cold solid foulant is provided to the solid inlet of the vessel. The carrier gas containing the foulant is provided to the carrier gas inlet of the vessel. The foulant condenses or desublimates onto the recycled solid foulant, forming a foulant-depleted carrier gas and a solid foulant product. The solids conveyance device passes the solid foulant product out of the vessel. The foulant-depleted carrier gas leaves the vessel. The solid foulant product is split into a final solid foulant product and a recycled solid foulant. The recycled solid foulant is cooled through the coolant system to produce the cold solid foulant. In this manner, the foulant is removed from the carrier gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cold cathode switching device and converter

A cold-cathode switching device is presented. The cold-cathode switching device includes a housing defining a chamber; an ionizable gas disposed in the chamber; and a plurality of electrodes disposed in the chamber. The plurality of electrodes includes a cathode and an anode defining a discharge gap, and wherein at least one of the cathode and anode comprises a material that is liquid at an operating temperature of the cathode or the anode.

42 ENGINEERING↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗