Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

THz Radar Observations of Hydrometeors in a Spray Chamber

Abstract A THz radar, with its wide bandwidth, is capable of high‐resolution imaging down to the centimeter scale. In this study, a THz radar is applied to detect hydrometeors generated in a spray chamber. The observed backscattering signals show fluctuations at centimeter scales, indicating various hydrometeor distribution patterns along the radar beam. A co‐located High‐Speed Imaging (HSI) sensor is used to measure the Drop Size Distributions (DSD) in the spray chamber. The radar sampling beam is well aligned with the HSI probes, allowing an objective comparison between the remote sensing and in situ observations. In this study, the observed radar power is compared with the power estimated from the HSI measurements. Results show great consistency, with power difference smaller than 0.5 dB. This study demonstrates the feasibility and great potential of using a THz radar for ultra‐high‐resolution observations of clouds in a laboratory facility, and in the real atmosphere.

54 ENVIRONMENTAL SCIENCES↗

HH 222: A GIANT HERBIG-HARO FLOW FROM THE QUADRUPLE SYSTEM V380 ORI

HH 222 is a giant shocked region in the L1641 cloud, and is popularly known as the Orion Streamers or ''the waterfall'' on account of its unusual structure. At the center of these streamers are two infrared sources coincident with a nonthermal radio jet aligned along the principal streamer. The unique morphology of HH 222 has long been associated with this radio jet. However, new infrared images show that the two sources are distant elliptical galaxies, indicating that the radio jet is merely an improbable line-of-sight coincidence. Accurate proper motion measurements of HH 222 reveal that the shock structure is a giant bow shock moving directly away from the well-known, very young, Herbig Be star V380 Ori. The already known Herbig-Haro object HH 35 forms part of this flow. A new Herbig-Haro object, HH 1041, is found precisely in the opposite direction of HH 222 and is likely to form part of a counterflow. The total projected extent of this HH complex is 5.3 pc, making it among the largest HH flows known. A second outflow episode from V380 Ori is identified as a pair of HH objects, HH 1031 to the northwest and the already known HH 130 to the southeast, along an axis that deviates from that of HH 222/HH 1041 by only 3.°7. V380 Ori is a hierarchical quadruple system, including a faint companion of spectral type M5 or M6, which at an age of ∼1 Myr corresponds to an object straddling the stellar-to-brown dwarf boundary. We suggest that the HH 222 giant bow shock is a direct result of the dynamical interactions that led to the conversion from an initial non-hierarchical multiple system into a hierarchical configuration. This event occurred no more than 28,000 yr ago, as derived from the proper motions of the HH 222 giant bow shock.

79 ASTRONOMY AND ASTROPHYSICS↗

AlignOT: An Optimal Transport Based Algorithm for Fast 3D Alignment With Applications to Cryogenic Electron Microscopy Density Maps

Aligning electron density maps from Cryogenic electron microscopy (cryo-EM) is a first key step for studying multiple conformations of a biomolecule. As this step remains costly and challenging, with standard alignment tools being potentially stuck in local minima, we propose here a new procedure, called AlignOT, which relies on the use of computational optimal transport (OT) to align EM maps in 3D space. By embedding a fast estimation of OT maps within a stochastic gradient descent algorithm, our method searches for a rotation that minimizes the Wasserstein distance between two maps, represented as point clouds. Here, we quantify the impact of various parameters on the precision and accuracy of the alignment, and show that AlignOT can outperform the standard local alignment methods, with an increased range of rotation angles leading to proper alignment. We further benchmark AlignOT on various pairs of experimental maps, which account for different types of conformational heterogeneities and geometric properties. As our experiments show good performance, we anticipate that our method can be broadly applied to align 3D EM maps.

3D alignment↗

Estimation, UQ, and Sensitivity Analysis for a New Diagnostic Setup [Slides]

This is for an early career talk I am giving at the Association for Women in Math’s Research Symposium. It provides a general overview of three projects: the first focuses on velocity measurements from optical laser diagnostics, the second focuses on probe alignment and location (metrology), and the third is my Site-Directed Research and Development (SDRD) which focuses on neural networks for image datasets. All three projects have strong uncertainty quantification components.

97 MATHEMATICS AND COMPUTING↗

Simple spectroscope used with solid state image amplifier over wide spectral range

Prism plus image amplifier panel provides visual image of many infrared spectral lines from carbon arc impregnated with metal compound. Different metal compounds generate various desired spectra. Panel also aligns and focuses simple spectroscopes for detecting spectral lines inside and outside visible region.

Brown, R. L., Sr.↗

Spectrum-Imaging Detector Array With Integrated Filter

Proposed rectangular array of photodetectors in imaging spectrometer includes integral filter deposited directly on imaging array which would not become misaligned or misregistered as result of mechanical shock, vibration, or differential thermal expansion. Need for precise alignment and registration of filter cannot be over-emphasized.

Labaw, Clayton C.↗

Summary of AXAF calibration requirements

The following summarizes requirements on the High Resolution Mirror Assembly (HRMA) and HRMA/SI calibration. The lists of calibration measurements assume that the HRMA meets the CTT requirement that the XRCF test environment shall have not more than a 10 percent effect on the encircled energy in 1 arcsec and that it can be calibrated to 1 percent. This implies that the offloading scheme has been implemented in the HRMA. It should be remembered that there are additional calibrations needed for: aspect system; tracking; gyros; other parts of the PCAS; spacecraft timing and checks on timing accuracy for all SIs after integration in the spacecraft; ficucial lights and periscope; alignments; optical metrology data: lengths and diameters with errors on mirror elements and optical interferometer data on surface figure; and throughput and imaging stability test: an end-to-end test that can be used after the XRCF to verify that the x-ray throughput and imaging quality have not been degraded. The tables presented give a summary of the integration times for HRMA and HRMA/SI calibration.

Kellogg, E.↗

"We Burn to Learn" About Fuel-Air Mixing Within Aircraft Powerplants

I am working with my branch s advanced diagnostics team to investigate fuel-air mixing in jet-fueled gas turbine combustors and jet-fuel reformers. Our data acquisition begins with bench-top experiments which will help with calibration of equipment for facility testing. While conducting the bench-top experiments I learned to align laser and optical equipment to collect data, to use the data acquisition software, and to process the data into graphs and images. which jet he1 is to be reformed into hydrogen. Testing will commence shortly, after which we will obtain and analyze data and meet a critical milestone for the end of September. I am also designing the layout for a Schlieren system that will be used during that time frame. A Schlieren instrument records changes in the refractive index distribution of transparent media like air flows. The refractive index distribution can then be related to density, temperature, or pressure distributions within the flow. I am working on a scheme to quantify this information and add to the knowledge of the fuel-air mixing process.

Robinson, Heidi N.↗

Highly Collimated Jets and Wide-angle Outflows in HH 46/47: New Evidence from Spitzer Infrared Images

We present new details of the structure and morphology of the jets and outflows in HH 46/47 as seen in Spitzer infrared images from IRAC and MIPS, reprocessed using the 'HiRes' deconvolution technique. HiRes improves the visualization of spatial morphology by enhancing resolution (to subarcsecond levels in IRAC bands) and removing the contaminating side lobes from bright sources. In addition to sharper views of previously reported bow shocks, we have detected (1) the sharply delineated cavity walls of the wide-angle biconical outflow, seen in scattered light on both sides of the protostar, (2) several very narrow jet features at distances approximately 400 AU to approximately 0.1 pc from the star, and (3) compact emissions at MIPS 24 m with the jet heads, tracing the hottest atomic/ionic gas in the bow shocks. Together the IRAC and MIPS images provide a more complete picture of the bow shocks, tracing both the molecular and atomic/ionic gases, respectively. The narrow width and alignment of all jet-related features indicate a high degree of jet collimation and low divergence (width of approximately 400 AU increasing by only a factor of 2.3 over 0.2 pc). The morphology of this jet, bow shocks, wide-angle outflows, and the fact that the jet is nonprecessing and episodic, constrain the mechanisms for producing the jet's entrained molecular gas, and origins of the fast jet, and slower wide-angle outflow.

Herbig-Haro objects↗

SU-E-J-107: Supervised Learning Model of Aligned Collagen for Human Breast Carcinoma Prognosis

Purpose: Our goal is to develop and apply a set of optical and computational tools to enable large-scale investigations of the interaction between collagen and tumor cells. Methods: We have built a novel imaging system for automating the capture of whole-slide second harmonic generation (SHG) images of collagen in registry with bright field (BF) images of hematoxylin and eosin stained tissue. To analyze our images, we have integrated a suite of supervised learning tools that semi-automatically model and score collagen interactions with tumor cells via a variety of metrics, a method we call Electronic Tumor Associated Collagen Signatures (eTACS). This group of tools first segments regions of epithelial cells and collagen fibers from BF and SHG images respectively. We then associate fibers with groups of epithelial cells and finally compute features based on the angle of interaction and density of the collagen surrounding the epithelial cell clusters. These features are then processed with a support vector machine to separate cancer patients into high and low risk groups. Results: We validated our model by showing that eTACS produces classifications that have statistically significant correlation with manual classifications. In addition, our system generated classification scores that accurately predicted breast cancer patient survival in a cohort of 196 patients. Feature rank analysis revealed that TACS positive fibers are more well aligned with each other, generally lower density, and terminate within or near groups of epithelial cells. Conclusion: We are working to apply our model to predict survival in larger cohorts of breast cancer patients with a diversity of breast cancer types, predict response to treatments such as COX2 inhibitors, and to study collagen architecture changes in other cancer types. In the future, our system may be used to provide metastatic potential information to cancer patients to augment existing clinical assays.

60 APPLIED LIFE SCIENCES↗

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unsteady Pressure-Sensitive-Paint Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

Unsteady Pressure-Sensitive Paint (UPSP) Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

SU-E-T-528: Robustness Evaluation for Fiducial-Based Accelerated Partial Breast Proton Therapy

Purpose: To investigate the robustness of the proton treatment plans in the presence of rotational setup error when patient is aligned with implanted fiducials. Methods: Five Stage I invasive breast cancer patients treated with the APBP protocol (PCG BRE007-12) were studied. The rotational setup errors were simulated by rotating the original CT images around the body center clockwise and counterclockwise 5 degrees (5CW and 5CCW). Manual translational registration was then performed to match the implanted fiducials on the rotated images to the original dataset. Patient contours were copied to the newly created CT set. The original treatment plan was applied to the new CT dataset with the beam isocenter placed at the geometrical center of PTV. The dose distribution was recalculated for dosimetric parameters comparison. Results: CTV and PTV (D95 and V95) coverages were not significantly different between the two simulated plans (5CW and 5CCW) and the original plan. PTV D95 and CTV D95 absolute difference among the three plans were relatively small, with maximum changes of 0.28 CGE and 0.15 CGE, respectively. PTV V95 and CTV V95 absolute differences were 0.79% and 0.48%. The dosage to the thyroid, heart, contralateral breast and lung remained zero for all three plans. The Dmax and Dmean to the volume of ipsilateral breast excluding CTV were compared, with maximum difference values of 1.02 CGE for Dmax and 3.56 CGE for Dmean. Ipsilateral lung Dmean maintained no significant changes through the three plan comparison, with the largest value 0.32 CGE. Ipsilateral lung Dmax was the most sensitive parameter to this simulation study, with a maximum difference at 20.2 CGE. Conclusion: Our study suggests that fiducial-based Accelerated Partial Breast Proton Therapy is robust with respect to +/− 5 degree patient setup rotational errors, as long as the internal fiducial markers are used for patient alignment.

60 APPLIED LIFE SCIENCES↗

Dynamics Explorer measurements of particles, fields, and plasma drifts over a horse-collar auroral pattern

As shown from ground-based measurements and satellite-borne imagers, one type of global auroral pattern characteristic of quiet (usually northward IMF) intervals is that of a contracted but thickened emission region of a pattern referred to as 'horse-collar' aurora (Hones et al., 1989). In this report we use the Dynamics Explorer data set to examine a case in which this horse-collar pattern was observed by the DE-1 auroral imager, while at the same time DE-2, at lower altitude, measured precipitating particles, electric and magnetic fields, and plasma drifts. Our analysis shows that, in general, there is close agreement between the optical signatures and the particle precipitation patterns. In many instances, over scales ranging from tens to a few hundred kilometers, electron precipitation features and upward field-aligned currents are observed at locations where the plasma flow gradients indicate negative V-average x E. The particle, plasma, and field measurements made along the satellite track and the 2D perspective of the imager provide a means of determining the configuration of convective flows in the high-latitude ionosphere during this interval of northward IMF. Recent mapping studies are used to relate the low-altitude observations to possible magnetospheric source regions.

Sharber, J. R.↗

STRONG LENSING BY SUBHALOS IN THE DWARF-GALAXY-MASS RANGE. II. DETECTION PROBABILITIES

The dark halo substructures predicted by current cold dark matter simulations may in principle be detectable through strong-lensing image-splitting of quasars on small angular scales (0.01 arcsec or below). Here, we estimate the overall probabilities for lensing by substructures in a host halo closely aligned to the line of sight to a background quasar. Under the assumption that the quasar can be approximated as a point source, the optical depth for strong gravitational lensing by subhalos typically turns out to be very small ({tau} < 0.01), contrary to previous claims. We therefore conclude that it is currently not feasible to use this strategy to put the simulation predictions for the dark matter subhalo population to the test. However, if one assumes the source to be spatially extended, as is the case for a quasar observed at radio wavelengths, there is a reasonable probability for witnessing substructure lensing effects even at rather large projected distances from the host galaxy, provided that the angular resolution is sufficient. While multiply imaged, radio-loud quasars would be the best targets for unambiguously detecting dark matter subhalos, even singly imaged radio quasars might be useful for setting upper limits on the abundance and central surface mass density of subhalos.

99 GENERAL AND MISCELLANEOUS↗

Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm

Purpose: In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. Methods: The study comprised ten prostate cancer patients, for whom a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). Results: The MAE within the body contour was 36.5 ± 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% ± 0.2% (1 s.d.) between sCT and rCT, whereas it was −0.3% ± 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. Conclusions: The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties introduced by variations in patient geometry between imaging sessions.

60 APPLIED LIFE SCIENCES↗