Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Structural properties and recrystallization effects in ion beam modified B20-type FeGe films

Disordered iron germanium (FeGe) has recently garnered interest as a testbed for a variety of magnetic phenomena as well as for use in magnetic memory and logic applications. This is partially owing to its ability to host skyrmions and antiskyrmions—nanoscale whirlpools of magnetic moments that could serve as information carriers in spintronic devices. In particular, a tunable skyrmion–antiskyrmion system may be created through precise control of the defect landscape in B20-phase FeGe, motivating the development of methods to systematically tune disorder in this material and understand the ensuing structural properties. To this end, we investigate a route for modifying magnetic properties in FeGe. In particular, we irradiate epitaxial B20-phase FeGe films with 2.8 MeV Au 4+ ions, which creates a dispersion of amorphized regions that may preferentially host antiskyrmions at densities controlled by the irradiation fluence. To further tune the disorder landscape, we conduct a systematic electron diffraction study with in situ annealing, demonstrating the ability to recrystallize controllable fractions of the material at temperatures ranging from ~150 to 250°C. Finally, we describe the crystallization kinetics using the Johnson–Mehl–Avrami–Kolmogorov model, finding that the growth of crystalline grains is consistent with diffusion-controlled one-to-two dimensional growth with a decreasing nucleation rate.

36 MATERIALS SCIENCE↗

Beam-driven dynamics of aluminium dopants in graphene

Abstract Substituting heteroatoms into graphene can tune its properties for applications ranging from catalysis to spintronics. The further recent discovery that covalent impurities in graphene can be manipulated at atomic precision using a focused electron beam may open avenues towards sub-nanometer device architectures. However, the preparation of clean samples with a high density of dopants is still very challenging. Here, we report vacancy-mediated substitution of aluminium into laser-cleaned graphene, and without removal from our ultra-high vacuum apparatus, study their dynamics under 60 keV electron irradiation using aberration-corrected scanning transmission electron microscopy and spectroscopy. Three- and four-coordinated Al sites are identified, showing excellent agreement with ab initio predictions including binding energies and electron energy loss spectrum simulations. We show that the direct exchange of carbon and aluminium atoms predicted earlier occurs under electron irradiation, although unexpectedly it is less probable than the same process for silicon. We also observe a previously unknown nitrogen–aluminium exchange that occurs at Al–N double-dopant sites at graphene divacancies created by our plasma treatment.

36 MATERIALS SCIENCE↗

SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

60 APPLIED LIFE SCIENCES↗

Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

60 APPLIED LIFE SCIENCES↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

Thermocouple and RTD Drift Due to Neutron Irradiation and Temperature for Space Nuclear Applications: A Review

Temperature measurement is a key factor in the safe and reliable operation of nuclear reactors. Thermocouples and resistance temperature detectors (RTDs) are among the most common and reliable tools deployed for temperature measurement, and some are capable of operating in extreme environments such as very high temperature and neutron radiation fields anticipated in nuclear thermal propulsion (NTP) or fission surface power. These devices are known to exhibit drifting behavior in their temperature readings throughout their operational lifetimes. Here, to help select appropriate instrumentation, it is important to identify the factors that influence drift as well as typical behavior in these environments. This work is focused on identifying contributing factors in the performance of thermocouples and RTDs. An extensive literature review is included that discusses several experimental results in different environments. Although individual instrument performance may vary with construction methods, materials selection, and vendors, this review aims to assist in the selection process and identify typical expected behaviors of several devices.

Chesser, Ryan J. [Oak Ridge National Laboratory (O↗

Hole Trapping in Halide Perovskites Induces Phase Segregation

Metal halide perovskites have garnered a great deal of attention for their applications in photovoltaics, LEDs, and radiation detection. The ease of solution processing high-quality perovskite semiconductors with large absorption coefficients and tolerance to native defects is decidedly attractive. Additionally, the ability to precisely tune the band gap of halide perovskites through compositional alloying of the halide ion is of particular interest for a range of applications, especially for tandem solar cells. However, under steady state light irradiation, an initially homogeneous mixed halide perovskite (MHP) will form local domains that are rich in one halide ion (e.g., Br or I). This light-induced phase segregation in MHPs forms iodide-rich domains that act as charge carrier traps and lowers the efficiency of perovskite-based devices. Thus, phase segregation poses a serious challenge to the implementation of MHPs in real-world device settings. Interestingly, when a phase segregated MHP film is placed in the dark, entropic driving forces become dominant and the segregated perovskite remixes and returns to its initially homogeneous state. Several key mechanistic details of phase segregation have been elucidated over the years. However, there are still aspects of halide segregation that are not clear, and there is ongoing debate in the literature as to what are the key factors that contribute to the mechanism. This Account discusses recent results that point to the specific role of hole trapping in phase segregation. Interestingly, generation of holes through above-band-gap excitation or through electrochemical injection increases ion migration and leads to phase segregation. The thermodynamic and redox properties of halide perovskites provide a strong driving force for hole trapping and oxidation of iodide species in MHPs. However, mobile halide species within the perovskite lattice take time to migrate and generate halide-rich domains. When in contact with a nonpolar solvent, the migration of iodine species is further extended to expulsion of iodine from the perovskite film. Thus, the mobility of halides and their susceptibility to hole-induced oxidation play a crucial role in determining the long-term stability of metal halide perovskites. Strategies to gain kinetic control over ion migration to slow phase segregation are needed to overcome these hurdles and achieve stable mixed halide perovskites. Modification of the perovskite composition through introduction of different cations or halide ions, or introduction of low-dimensional perovskite phases may suppress phase segregation. Furthermore, in achieving stability and improving the efficiency of perovskite solar cells and light emitting devices with minimal impacts, suppression of segregation remains the key factor.

36 MATERIALS SCIENCE↗

Operational Characteristics of SiC Diodes as Ionizing Radiation Detectors

In order to explore the possibility of using SiC detectors in nuclear physics applications in extreme environments, the operational characteristics of 4H-SiC Schottky diodes with different dopant concentrations have been studied with {sup 12}C and {sup 16}O ions at various incident energies. The detector response has been investigated in term of linearity, energy resolution, signal rise-time and Charge Collection Efficiency as a function of the applied reverse bias and of the dopant concentration. Moreover, since one of the most promising properties of SiC detectors is their radiation hardness, the radiation damage, produced by irradiating SiC diodes with {sup 16}O ions at 35.2 MeV, has been evaluated by measuring the degradation of both the signal pulse-height and the energy resolution as a function of the {sup 16}O fluence.

36 MATERIALS SCIENCE↗

Resonance Raman mapping as a tool to monitor and manipulate Si nanocrystals in Si-SiO{sub 2} nanocomposite

Specially designed laser heating experiment along with Raman mapping on Si-SiO{sub 2} nanocomposites elucidates the contribution of core and surface/interface in the intermediate frequency range (511–514 cm{sup −1}) Si phonons. The contribution of core to surface/interface increases with the size of Si nanocrystal, which itself increases on laser irradiation. Further, it is found that resonance Raman is crucial to the observance of surface/interface phonons and wavelength dependent Raman mapping can be corroborated with band edges observed in absorption spectra. This understanding can be gainfully used to manipulate and characterize Si-SiO{sub 2} nanocomposite, simultaneously for photovoltaic device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasmonic nanostructures for conversion of optical power to electrical power

A plasmoelectric device for conversion of optical power to direct current (DC) electrical power includes a first plasmonic nanostructure having a first resonance value and a second plasmonic nanostructure having a second resonance value. The first and second plasmonic nanostructures are electrically coupled and the first plasmonic nanostructure is configured to receive irradiation at a first irradiation value and the second plasmonic nanostructure is configured to receive irradiation at a second irradiation value, to induce charge transfer between the first and second plasmonic nanostructures.

Sheldon, Matthew↗

Cryogenic molecular separation system for radioactive {sup 11}C ion acceleration

A {sup 11}C molecular production/separation system (CMPS) has been developed as part of an isotope separation on line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. In the ISOL system, {sup 11}CH{sub 4} molecules will be produced by proton irradiation and separated from residual air impurities and impurities produced during the irradiation. The CMPS includes two cryogenic traps to separate specific molecules selectively from impurities by using vapor pressure differences among the molecular species. To investigate the fundamental performance of the CMPS, we performed separation experiments with non-radioactive {sup 12}CH{sub 4} gases, which can simulate the chemical characteristics of {sup 11}CH{sub 4} gases. We investigated the separation of CH{sub 4} molecules from impurities, which will be present as residual gases and are expected to be difficult to separate because the vapor pressure of air molecules is close to that of CH{sub 4}. We determined the collection/separation efficiencies of the CMPS for various amounts of air impurities and found desirable operating conditions for the CMPS to be used as a molecular separation device in our ISOL system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring, Cutting and Sorting Irradiated Control Rods to Limit the Volume of Intermediate Level Long-lived Waste - 17001

During operation, the PWR control rods are either completely extracted (scram or safety rods) or partially inserted in the operating zone of the core (fine control or operating rods). At the nominal rating conditions or close to them, the operating zone is limited to some steps of insertion in the order of a few tens of cm. In fact, only the lower part of the control rods are subjected to a significant neutron flux with an impact on the neutron activation and so on the waste classification (Low Level Short-lived Waste versus Intermediate Level Long-lived Waste). Our calculative as well as experimental experience confirms the significant presence of radionuclides in the control rods, but only in the lower parts. Measuring, cutting and finally sorting control rod scraps can reduce the volume of Intermediate Level Long-lived Waste planned for our storage deposit facility. This paper presents the EDF/DP2D methodologies followed to determine the sort criteria between the Low Level Short-lived Waste versus the Intermediate Level Long-lived Waste zones for the Silver-Indium-Cadmium control rods. The irradiated control rods are stored in cases without their head. Each case can contain several control rods, and the cases are stored under water in the fuel assembly pool. To calculate the radioactive inventories, we have developed a calculation scheme which is composed of a 3-dimensional mapping of the neutron flux, a calculation of the evolution of the isotopic compositions under neutron flux and finally a comparison between calculated and measured values. The main hypotheses of the control rods calculation take into account: - 3-dimensional geometry and 3-dimensional neutron sources distribution, - the isotopic compositions including impurities, - the history of irradiation resulting mainly from the daily power production, the positions of the control rods in the loading patterns and the positions in the axial operating zone. In order to validate the calculations, measurements were made 20 meters under water in the fuel assembly pool. The experimental results show the presence of many gamma emitter radionuclides. Only Ag-108m was retained for validating the calculations. This is due to the fact that silver is considered as the 'standard' chemical element for our control rods and silver produces Ag-108m which is a long-lived gamma emitter radionuclide. The analysis of the calculated results and the measured values allow us to build a simplified physics model for the simulation of the control rods activation. Finally three sort criteria can be proposed: - Without measurement devices, the sorting is based on an empirical sort criterion. Cuttings must then be made on the 2 back-ends of the control rod pins. This option is due to the difficulty in knowing the orientation of the pins in the storage cases. The cutting lines are placed at approximately 1 m from the 2 back-ends of the pins. This approach does not allow a great optimization of the sorting, less than 50% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With a simple dose rate measurement device, the knowledge of the orientation of the pins in the storage cases allows us to limit cuttings to the lower part of the control rods. Depending on the 'top to tail' cases, between approximately 50% and 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With an accurate measurement device, the sorting can be based on a specific activity of Ag-108m. Over 4400 Bq/g of Ag-108m (corresponding to the Intermediate Level Long-lived Waste limit), the control rod pieces can be considered as a long-lived waste. The measurements must be made over the 2 back-ends of control rod pins to examine the cases of 'top to tail' storage. This approach allows a great optimization of the sorting. Depending on the history of irradiation, more than 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent-free bottom-up patterning of zeolitic imidazolate frameworks

Patterning metal-organic frameworks (MOFs) at submicrometer scale is a crucial yet challenging task for their integration in miniaturized devices. Here we report an electron beam (e-beam) assisted, bottom-up approach for patterning of two MOFs, zeolitic imidazolate frameworks (ZIF), ZIF-8 and ZIF-67. A mild pretreatment of metal oxide precursors with linker vapor leads to the sensitization of the oxide surface to e-beam irradiation, effectively inhibiting subsequent conversion of the oxide to ZIFs in irradiated areas, while ZIF growth in non-irradiated areas is not affected. Well-resolved patterns with features down to the scale of 100 nm can be achieved. This developer-free, all-vapor phase technique will facilitate the incorporation of MOFs in micro- and nanofabrication processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Weak-antilocalization and surface dominated transport in topological insulator Bi{sub 2}Se{sub 2}Te

We explore the phase coherence of thin films of the topological insulator material Bi{sub 2}Se{sub 2}Te grown through pulsed laser deposition (PLD) technique. The films were characterised using various techniques for phase and composition. The films were found to be of good quality. We carried out extensive magneto-transport studies of these films and found that they exhibit two dimensional weak antilocalization behaviour. A careful analysis revealed a relatively high phase coherence length (58nm at 1.78K) for a PLD grown film. Since PLD is an inexpensive technique, with the possibility to integrate with other materials, one can make devices which can be extremely useful for low power spintronics and topological quantum computation.

36 MATERIALS SCIENCE↗

Growth evolution of AlN films on silicon (111) substrates by pulsed laser deposition

AlN films with various thicknesses have been grown on Si(111) substrates by pulsed laser deposition (PLD). The surface morphology and structural property of the as-grown AlN films have been investigated carefully to comprehensively explore the epitaxial behavior. The ∼2 nm-thick AlN film initially grown on Si substrate exhibits an atomically flat surface with a root-mean-square surface roughness of 0.23 nm. As the thickness increases, AlN grains gradually grow larger, causing a relatively rough surface. The surface morphology of ∼120 nm-thick AlN film indicates that AlN islands coalesce together and eventually form AlN layers. The decreasing growth rate from 240 to 180 nm/h is a direct evidence that the growth mode of AlN films grown on Si substrates by PLD changes from the islands growth to the layer growth. The evolution of AlN films throughout the growth is studied deeply, and its corresponding growth mechanism is hence proposed. These results are instructional for the growth of high-quality nitride films on Si substrates by PLD, and of great interest for the fabrication of AlN-based devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferroelectric domain engineering by focused infrared femtosecond pulses

We demonstrate infrared femtosecond laser-induced inversion of ferroelectric domains. This process can be realised solely by using tightly focused laser pulses without application of any electric field prior to, in conjunction with, or subsequent to the laser irradiation. As most ferroelectric crystals like LiNbO{sub 3}, LiTaO{sub 3}, and KTiOPO{sub 4} are transparent in the infrared, this optical poling method allows one to form ferroelectric domain patterns much deeper inside a ferroelectric crystal than by using ultraviolet light and hence can be used to fabricate practical devices. We also propose in situ diagnostics of the ferroelectric domain inversion process by monitoring the Čerenkov second harmonic signal, which is sensitive to the appearance of ferroelectric domain walls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗

ON-GOING STATUS OF KJRR FUEL (U-7MO) QUALIFICATION

In order to cope with global shortage of Mo-99 supplies and with growing demand of neutron transmutation doping, KJRR construction plan has been launched since April 2012 to provide self-sufficiency of domestic RI demand, and to extend Si doping capacity for power device market growth. Through comprehensive surveillance of the fuels in-reactor behavior, KAERI has selected the fuel meat of U-7%Mo dispersion in an aluminum matrix with 5wt%Si for the KJRR fuel. As part of the efforts for fuel licensing and qualification of the KJRR fuel, an LTA irradiation test at the ATR started from November 2015 was successfully completed by reaching at 219 EFPD in the end of February 2017. Together with the results of HAMP-1 already completed irradiation and PIE, the successful irradiation of the LTA also demonstrates the fuel integrity under more rigorous conditions than the KJRR operation conditions. This paper updates the current status of the KJRR U7Mo (8 g-U/cm3) LTA irradiation and PIE plan up to date as of February 2017.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗