Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Heat pipes for spacecraft temperature control: An assessment of the state-of-the-art

Spacecraft applications that require the efficient cooling of high-powered components, the precise temperature control of sensitive electronic and optical components, and the protection of cooled components from temporary, adverse environmental conditions are increasing. Heat pipes using gas, vapor, liquid, or voltage control to provide variable conductance or diode thermal behavior have been and are continuing to be developed to meet increasingly difficult requirements. The various control techniques are critically evaluated using characteristic features and properties, including heat transport capability, volume and mass requirements, complexity and ease of fabrication, reliability, and control characteristics. As a result, advantages and disadvantages of specific approaches are derived and discussed. Using four development levels, the state-of-the-art of the various heat pipe temperature control techniques is assessed.

Groll, M.↗

Envelope Protection for In-Flight Ice Contamination

Fatal loss-of-control (LOC) accidents have been directly related to in-flight airframe icing. The prototype system presented in this paper directly addresses the need for real-time onboard envelope protection in icing conditions. The combinations of a-priori information and realtime aerodynamic estimations are shown to provide sufficient input for determining safe limits of the flight envelope during in-flight icing encounters. The Icing Contamination Envelope Protection (ICEPro) system has been designed and implemented to identify degradations in airplane performance and flying qualities resulting from ice contamination and provide safe flight-envelope cues to the pilot. Components of ICEPro are described and results from preliminary tests are presented.

Gingras, David R.↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A pressure control analysis of cryogenic storage systems

Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments.

Lin, C.-S.↗

A pressure control analysis of cryogenic storage systems

Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments.

Lin, C.-S.↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Safety Assessment of El Cabril, the Spanish Surface Disposal facility for LILW and VLLW - 17233

El Cabril project was launched in 1986, for Low and Intermediate Level Waste (LILW) disposal, based on concrete barriers and concrete disposal units. The operation of a Very Low Leve Waste (VLLW) complementary facility based on clay and High Density Polyethylene (HDPE) barriers and different types of disposal units started in 2008. Two main objectives are considered in the design: Immediate and post-closure protection and no radiological restrictions, after institutional control period. To fulfil these objectives several design criteria like waste isolation through a multi-barrier system, surveillance period no longer than 300 years and limitation of activity are applied. The Safety Assessment process follows a methodology which, taking into account important facts like safety and design criteria, time frame, radiological protection criteria, waste characteristics, environment, FEPs (features, events and processes), etc., develops different scenarios, models and calculations to define the safety approach. This safety approach follows the current guides and recommendations of international organizations, it covers the potential impact of the facility for the operational and long-term periods and it includes normal evolution and less likely accidental and inadvertent human intrusion events. All the studies and considerations done for the Safety Assessment have to be included in a safety Report, required for getting the Operation License for Nuclear Installations in Spain. The content of this Report is defined by the Spanish regulation and it has to be revised if there is a change in the facility that may affect the safety. It is also mandatory making a Safety Periodic Review (every 10 years in the case of El Cabril) that has to be presented to the Regulatory Council. This paper outlines the principles, objectives and criteria of El Cabril's disposal installation and it explains the safety assessment performed, for both LILW and VLLW disposal, as part of the documentation produced to obtain the authorization to operate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of New CERCLA Five-Year Review Guidance at Hanford - 16403

Under CERCLA, the implementation of remedial actions established in records of decision (ROD) are required to be reviewed every five years to evaluate their effectiveness in protecting human health and the environment. Past reviews have included evaluation of actions that were not implemented under existing RODs and, therefore, not subject to the requirement. While commendable for its transparency, discussing these out-of-scope actions created confusion and elicited comments that required time and effort to resolve. The fourth CERCLA Five Year Review (FYR) at the Hanford Site embraces the EPA guidance designed to streamline the process and focuses on the specific objectives of the review. This guidance and the training materials developed jointly by multiple federal agencies including EPA, DOE, DOD, and Department of the Interior (DOI), demonstrate a focused approach to the FYR process and offer real-world examples for streamlining this important document. This paper discusses the focused approach and process changes implemented at the Hanford Site that reduced the size and complexity of the document and provided the DOE, Richland Operations Office, with an efficient, effective template for preparing subsequent reviews. One key change was a thorough evaluation of what operable units were discussed and what operable units were not discussed in the five-year review. This process resulted in a reduction of 14 operable unit discussions. Additionally, extensive referencing of previously published CERCLA documents including closure reports and periodic groundwater monitoring reports minimized the amount of analytical data tables necessary to support the discussion. The Hanford five year review made good use of technology and provided internet links to existing documents where detailed information and voluminous analytical data reside. This eliminated the use of extensive data tables and summaries. The resulting five protectiveness determinations include: 1) 'Protective' which is used when there is sufficient data to conclude that the remedy is functioning as intended; 2) 'Protective in the short term' which is used when the data and/or documentation review raises issues that could affect future protectiveness; 3) 'Will be protective' which is used when the remedy under construction is anticipated to be protective on completion; 4) 'Protectiveness deferred' which is typically used when additional information is needed; and 5) 'Not protective' which is used when risks are not under control. Reviewing only on the appropriate operable units, and supporting the analysis of remedy performance with focused data, the resulting protectiveness determinations and overall effectiveness of the document were significantly improved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned from Annual Inspection Process - 12329

The U.S. Department of Energy (DOE) Office of Legacy Management's (LM) mission is to manage DOE's post-closure responsibilities and ensure the future protection of human health and the environment. LM has control and custody of legacy land, structures, and facilities and is responsible for maintaining them at levels suitable for their long-term use. As defined by the DOE guidance document Long-Term Stewardship Planning Guidance for Closure Sites, long-term stewardship refers to all activities necessary to ensure protection of human health and the environment. These activities include, but are not limited to, 'all engineered and institutional controls (ICs) designed to contain or to prevent exposure to residual contamination and waste, such as surveillance activities, record-keeping activities, inspections, groundwater monitoring, maintenance of other barriers and contained structures, access control, and posting signs'. The development and management of ICs have been, and continue to be, critical to the success of LM surveillance and maintenance activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RIP3-dependent necrosis induced inflammation exacerbates atherosclerosis

Atherothrombotic vascular disease is already the leading cause of mortality worldwide. Atherosclerosis shares features with diseases caused by chronic inflammation. More attention should concentrates on the innate immunity effect atherosclerosis progress. RIP3 (receptor-interacting protein kinase 3) act through the transcription factor named Nr4a3 (Nuclear orphan receptors) to regulate cytokine production. Deletion RIP3 decreases IL-1α production. Injection of anti-IL-1α antibody protects against the progress of atherosclerosis in ApoE −/− mice. RIP3 as a molecular switch in necrosis, controls macrophage necrotic death caused inflammation. Inhibiting necrosis will certainly reduce atherosclerosis through limit inflammation. Necrotic cell death caused systemic inflammation exacerbated cardiovascular disease. Inhibition of necrosis may yield novel therapeutic targets for treatment in years to come. - Highlights: • RIP3 regulate the Nr4a3 to control cytokine production. • Deletion RIP3 decreases IL-1a production. • Injection anti-IL-1a antibody protects against the progress of atherosclerosis. • RIP3 controls macrophage necrotic dead caused inflammation.

60 APPLIED LIFE SCIENCES↗

Barriers and Alternatives to Encryption in Critical Nuclear Systems

Over the past decade, cybersecurity researchers have released multiple studies highlighting the insecure nature of I&C system communication protocols. In response, standards bodies have addressed the issue by adding the ability to encrypt communications to some protocols in some cases, while control system engineers have argued that encryption within these kinds of high consequence systems is in fact dangerous. Certainly, control system information between systems should be protected. But encrypting the information may not be the best way to do so. In fact, while in IT systems vendors are concerned with confidentiality, integrity, and availability, frequently in that order, in OT systems engineers are much more concerned with availability and integrity that confidentiality. In this paper, we will counter specific arguments against encrypting control system traffic, and present potential alternatives to encryption that support nuclear OT system needs more strongly that commodity IT system needs while still providing robust integrity and availability guarantees.

42 ENGINEERING↗

Initial Assessment of Cover Degradation Features at the Mexican Hat, Utah, UMTRCA Disposal Site - 19556

The Mexican Hat, Utah, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site is located on the Navajo Reservation in southeast Utah. The US Nuclear Regulatory Commission licensed the site to the US Department of Energy Office of Legacy Management (LM) for custody and long-term care. LM manages long-term surveillance and maintenance activities at the site with the principal goal of protecting human health and the environment. The disposal cell was designed to encapsulate low-level radioactive mill tailings and other residual radioactive materials (RRM) in a way that minimizes the need for active maintenance and limits radon gas emanation and precipitation infiltration. The disposal cell has a multicomponent cover, consisting of a 60 cm thick (24 inch), low-permeability, bentonite-amended radon barrier, overlain by a 15 cm thick (6 inch) sandy gravel bedding/filter layer and a 30 cm thick (12 inch) riprap erosion-protection layer. Under UMTRCA, designs intended to control and contain RRM shall be effective for up to 1000 years, to the extent reasonably achievable and, in any case, for at least 200 years. In 2016, multiple subtle depressions were identified on the rock cover along the toe and lower portions of the northeast side slope of the disposal cell. Due to concerns regarding potential impacts to disposal cell performance and erosion resistance, evaluations of the depressions and cell cover design and construction were initiated. The evaluations included reviews of the disposal cell as-built drawings and supporting design calculations for the rock cover components. Also, in 2017, a weather monitoring station was installed at the site to collect continuous site-specific meteorological data, and repeatable ground-based light imaging, detection, and ranging (lidar) topographical and aerial photogrammetry surveys were implemented to monitor for potential changes in the surface depression features. The evaluations also included visual inspections of the depressions, and in 2018, small-area manual excavations of the rock cover components (test pits) were performed to observe the conditions of the cover components, scan for radioactivity, and observe evidence of erosion on the surface of the radon barrier material. Voids and incisions were discovered within the radon barrier on the north and northeast side slopes of the disposal cell. Visual observations at test pits indicate that the bedding/filter material is highly segregated and may not be in conformance with the disposal cell engineering and construction design specifications. Post-construction development of a weak to strongly cemented material has also been observed immediately below the base of the bedding layer in test pits with observed radon barrier degradation. A series of radiological surveys have been performed at the site, and radiological readings have not exceeded natural background conditions in the vicinity of the site. Thus, the site remains protective of human health and the environment. Implementation of continuous radiological monitoring at the site will be initiated in fall 2018 through the deployment of radon cups and thermoluminescent dosimeters to obtain data that provides supporting evidence that the disposal cell remains protective of human health and the environment. Evaluations to determine the cause(s) of the depression features and associated radon barrier erosion are ongoing. Possible mechanisms of cover degradation identified thus far include segregated bedding material that would allow for higher precipitation runoff velocities, resulting in erosion of the radon barrier; post-construction cementation of radon barrier or aeolian material that could negatively affect the performance of the radon barrier; cation exchange leading to the development of cementation; and aeolian deposition affecting precipitation runoff. Moreover, geotechnical sampling and testing is planned to verify spatial cover conditions relative to design specifications. The resulting information will be used to identify possible causes for the surface depressions and associated radon barrier degradation, gain insight on potential long-term performance implications along the side slopes of the disposal cell, and identify potential corrective actions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of the number of control points has on isodose distributions in a dynamic multileaf collimator intensity-modulated radiation therapy delivery

Intensity-modulated radiation therapy (IMRT) is a powerful technique in planning the delivery of dose. The most common IMRT delivery requires the use of moving multileaf collimators (MLCs) to deliver the requested fluence pattern. A dynamic delivery IMRT field file will contain several control points that are defined MLC shapes at a marked fraction of the delivered monitor units. The size of this file and the fidelity of the deliverable fluence are proportional to the number of control points defined. This study investigates the effect of reducing the number of control points has on the resultant dose distribution quality in complex IMRT in efforts to reduce transfer times, loading times, check sum times and file storage. Analysis was performed with 6 head and neck patients on an Eclipse version 8.5 treatment planning system (Varian, Palo Alto, CA). To ensure the quality of all treatments, Eclipse defines a minimum of 64 and a maximum of 320 control points per subfield (Eclipse Algorithms Reference guide). All 6 patients' plans were calculated with fixed 64, 166, and 320 control points using the sliding window technique. In addition, each plan was calculated in variable mode (Normal mode) in which the planning system determined the required number of control points. Each of the 4 plans for each patient was renormalized to provide the same mean planning target volume (PTV) 70 dose. Dose values for critical and target structures were examined for each patient. When examining the minimum, maximum, and mean doses to all target structures, it was noted that the greatest reduction in target dose coverage caused by reduced number of control points was 0.5%, which occurred for the minimum dose to the PTV56 structure in one plan.' Dose analysis for critical structures showed no clinically significant increase in dose when compared with the 320 control point plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Visible, Durable, Enforceable Institutional Controls: Weldon Spring Site - A 10-Year Journey - 13190

The DOE Office of Legacy Management's (LM's) mission is to manage the DOE's post-closure responsibilities and ensure the future protection of human health and the environment. LM has control and custody of legacy land, structures, and facilities and is responsible for maintaining them at levels suitable for their long-term use. This includes all engineered and institutional controls (ICs) designed as another level of assurance to prevent exposure to residual contamination and waste. The development and management of ICs has been, and continues to be, a critical component to the success of LM surveillance and maintenance activities. Many major federal laws, Executive Orders, regulations, and various other drivers influence the establishment and use of ICs at LM sites. LM uses a wide range of ICs to appropriately limit access to, or uses of, land, facilities, and other real and personal properties; protect the environment; maintain the physical safety and security of DOE facilities; and prevent or limit inadvertent human and environmental exposure to residual contaminants and other hazards. The ICs at the Weldon Spring, Missouri, Site were developed in close coordination with federal and state regulators. An Explanation of Significant Differences (ESD) was issued in February 2005, which clarified the use restrictions necessary for the remedial actions specified in the Records of Decision for the separate operable units to remain protective over the long-term. The operable units included the Chemical Plant Operable Unit, the Chemical Plant Groundwater Operable Unit, and the Quarry Residuals Operable Unit. The ESD clarified specific requirements for each site area that needed use restrictions and established how DOE would implement, maintain, and monitor the specific requirements. DOE developed the Long-Term Surveillance and Maintenance Plan for the U.S. Department of Energy Weldon Spring, Missouri, Site (LTS and M Plan) that addressed the full scope of the site management activities necessary to ensure that the Weldon Spring Site remains protective over the long-term. The LTS and M Plan is revised periodically to ensure its applicability to changing site, regulatory, or procedural conditions. In addition to addressing such activities as long-term groundwater monitoring and disposal cell maintenance, the LTS and M Plan was developed and issued to ensure that the use restrictions identified in the ESD were properly imposed and maintained. The LTS and M Plan included a detailed IC Implementation Plan, which includes a process for evaluating and identifying specific IC mechanisms that best accomplish the objectives set out in the ESD. Consistent with EPA guidance on selecting ICs, various IC mechanisms were evaluated, including government controls, proprietary controls, enforcement tools, and informational devices. Where appropriate, redundant mechanisms were employed to increase the effectiveness of the ICs. Information in the IC Implementation Plan includes: (1) a discussion of current site conditions (reflecting post-remedial action conditions for the Chemical Plant and Quarry Areas and the risk-basis for why use restrictions are needed); (2) the objectives of, or performance expectations for, the use restrictions; (3) specific ICs already in place and additional mechanisms identified for implementation; (4) a schedule for implementing additional ICs; (5) procedures for maintaining the ICs and for conducting periodic inspections; and (6) general provisions for the implementing ICs for the site. The actual agreements and documentation of the various ICs are included in an appendix of the LTS and M Plan. These documents are also available via the internet from the authorizing agencies (County, Missouri Department of Natural Resources, EPA, etc.) The Weldon Spring Site personnel have been successful in finalizing each of the ICs that were established for the site. The planning, establishment, and implementation of the ICs was a long and detailed process with several lessons-learned that were identified along the way. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring of Occupational Exposures in Albania Using TLD-100 cards (2003-2007)

In our paper is described the monitoring of occupational staff that works in ionising radiation field of the diagnostic centres in Albania for 2003-2007, and is analysed and discussed the mean annual dose rate recorded for above-mentioned period. The monitoring was based in TLD-100 dosimetric cards and the control was performed all over the country on bimonthly basis covering main and important cities like: Tirana, Durresi, Shkodra, Fieri, Vlora, Korca etj. The Department of Human and Environment Protection, at the Centre of Applied Nuclear Physics, through the dosimetric service carried out the monitoring for around 350 radiation workers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computer controlled tooling for Space Shuttle external tank

Implementation of the thermal protection system on the external tank used with the Space Shuttle requires application of various materials over large areas, to well-defined tolerances. This paper describes a minicomputer-based system developed to control the process tooling used for this task. The process requirements and the resultant hardware/software system are discussed. The results to date and plans for future expansion are outlined.

Meyer, R. A.↗

Enhanced Stability of Li Metal Anodes by Synergetic Control of Nucleation and the Solid Electrolyte Interphase

Use of a protective coating on a lithium (Li) metal anode (LMA) is an effective approach to enhance its coulombic efficiency and cycling stability. Here we report a facile approach to produce uniform silver (Ag) nanoparticle-decorated LMAs for high-performance Li metal batteries (LMBs). This effective treatment can lead to well controlled nucleation and the formation of a stable solid electrolyte interphase (SEI). Ag nanoparticles embedded in the surface of Li anodes induced uniform Li plating/stripping morphologies with reduced overpotential. More importantly, cross-linked lithium fluoride (LiF) networks formed during Ag+ reduction enabled a highly stable SEI layer. Based on the Ag-LiF decorated anodes, LMBs with LiNi1/3Mn1/3Co1/3O2 cathode (~1.8 mAh cm-2) can retain >80% capacity over 500 cycles. The similar results were also obtained when the same approach was applied to the design of stable sodium (Na) anodes. These results indicate that synergetic control of the nucleation and SEI is an efficient approach to stabilize rechargeable metal batteries.

anode↗