Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear data evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Completion Report for Model Evaluation Well ER-5-5: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-5-5 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in July and August 2012 as part of a model evaluation well program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radiological data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to obtain data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test MILK SHAKE, conducted in Emplacement Hole U-5k in 1968, which were considered to be uncertain due to the unknown extent of a basalt lava-flow aquifer present in this area. Well ER-5-5 is expected to provide information to refine the Phase II Frenchman Flat hydrostratigraphic framework model, if necessary, as well as to support future groundwater flow and transport modeling. The 31.1-centimeter (cm) diameter hole was drilled to a total depth of 331.3 meters (m). The completion string, set at the depth of 317.2 m, consists of 16.8-cm stainless-steel casing hanging from 19.4-cm carbon-steel casing. The 16.8-cm stainless-steel casing has one slotted interval open to the basalt lava-flow aquifer and limited intervals of the overlying and underlying alluvial aquifer. A piezometer string was also installed in the annulus between the completion string and the borehole wall. The piezometer is composed of 7.3-cm stainless-steel tubing suspended from 6.0-cm carbon-steel tubing. The piezometer string was landed at 319.2 m, to monitor the basalt lava-flow aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, preliminary water quality measurements, and water-level measurements. The well penetrated 331.3 m of Quaternary–Tertiary alluvium, including an intercalated layer of saturated basalt lava rubble. No well development or hydrologic testing was conducted in this well immediately after completion; however, a preliminary water level was measured in the piezometer string at the depth of 283.4 m on September 25, 2012. No tritium above the minimum detection limit of the field instruments was detected in this hole. Future well development, sampling, and hydrologic testing planned for this well will provide more accurate hydrologic information for this site. The stratigraphy, general lithology, and water level were as expected, though the expected basalt lava-flow aquifer is basalt rubble and not the dense, fractured lava as modeled. The lack of tritium transport is likely due to the difference in hydraulic properties of the basalt lava-flow rubble encountered in the well, compared to those of the fractured aquifer used in the flow and transport models.

58 GEOSCIENCES↗

Interaction of loading pattern and nuclear data uncertainties in reactor core calculations

Along with best-estimate calculations for design and safety analysis, understanding uncertainties is important to determine appropriate design margins. In this framework, nuclear data uncertainties and their propagation to full core calculations are a critical issue. To deal with this task, different error propagation techniques, deterministic and stochastic are currently developed to evaluate the uncertainties in the output quantities. Among these is the sampling based uncertainty and sensitivity software XSUSA which is able to quantify the influence of nuclear data covariance on reactor core calculations. In the present work, this software is used to investigate systematically the uncertainties in the power distributions of two PWR core loadings specified in the OECD UAM-Benchmark suite. With help of a statistical sensitivity analysis, the main contributors to the uncertainty are determined. Using this information a method is studied with which loading patterns of reactor cores can be optimized with regard to minimizing power distribution uncertainties. It is shown that this technique is able to halve the calculation uncertainties of a MOX/UOX core configuration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updates to the n+ 63,65 Cu Angular Distributions [Slides]

The performance of the benchmark suite is very sensitive to changes in the angular distribution data. The quasi-differential measurements performed by Blain et al at RPI provide a valuable constraint. Furthermore, ENDF/B-VIII.0 disagrees with their measurements consistently at 300 keV (the transition between RRR and high energy). The next step is to conservatively adjust the Legendre coefficients near 300 keV, validating performance against both critical benchmarks and the RPI quasi-differential measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998–2014

This report presents an enhanced performance evaluation of motor-driven pumps at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The motor-driven pump failure modes considered for standby systems are failure to start, failure to run less than or equal to one hour, and failure to run more than one hour; for normally running systems, the failure modes considered are failure to start and failure to run. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified in pump run hours per reactor year. Statistically significant decreasing trends were identified for standby systems industry-wide frequency of start demands, and run hours per reactor year for runs of less than or equal to one hour.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Data Sheets A=32

Nuclear spectroscopic information for experimentally investigated nuclides of mass 32 (Ne, Na, Mg, Al, Si, P, S, Cl, Ar) has been evaluated. The principal sources of the Adopted Levels presented for nuclides close to the stability line are Endt's evaluations (1990En08, 1978En02). The data sets for reactions and decays, including all available gamma-ray data, are based mostly on the original literature. Except for the half-life of {sup 32}Ne decay, no other details about its decay characteristics are available. Structure data for {sup 32}Ne and {sup 32}Na are limited to only one excited state in each. The {sup 32}Mg nuclide is of central and prime relevance in the 'island of inversion' at or near N = 20 semi-closed shell. The lifetime of only one excited state in {sup 32}Mg is known. The spin-parity assignments of several levels in this nucleus are not quite firm. The structure of {sup 32}Ar is limited to only one known state at low energy and two resonances in the giant-dipole excitation region. The {sup 32}P, {sup 32}S and {sup 32}Cl remain the most extensively studied nuclei through various reaction channels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Criticality Analysis Capability of SuperMC with ICSBEP

SuperMC is a general purpose, intelligent and multifunctional, continuous energy Monte Carlo program for the design and safety evaluation of nuclear systems. It is designed to perform the comprehensive neutronics calculation, taking the radiation transport as the core and including the depletion, radiation source term/dose/biohazard, material activation and transmutation, etc. The latest version of SuperMC can perform the simulation of neutron, photon and coupled neutron and photon transport, and also equipped with the functions of automatic modeling and visualization. SuperMC has been verified by more than 2000 benchmark models and experiments including the handbook of International Criticality Safety Benchmark Evaluation Project (ICSBEP), the Shielding Integral Benchmark Archive Database (SINBAD), etc. The fusion reactor (ITER benchmark model, FDS Fusion Reactors), fast reactors (BN600, CLEAR-I), PWR reactors (HM, BEAVRS) and cases from the International Reactor Physics handbook Evaluation Program (IRPhEP) were employed for validating the comprehensive capability for reactor applications. In this paper, the validation of SuperMC based on the handbook of ICSBEP will be presented. ICSBEP, released by OECD/NEA, contains criticality safety benchmark specifications derived from experiments that were performed at various nuclear critical facilities around the world, which was widely used to verify neutronic codes and associated nuclear data libraries for criticality safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Criticality Safety Program (NA-ESH) [Slides]

This presentation provides an overview of the Nuclear Criticality Safety Program, including its history, mission, vision, organization, measurement and evaluation priorities for FY23, 5-year plan, and cross-cutting nuclear data work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dosimetric results on EURECA

Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLD's). Evaluation of these detectors yields data on absorbed dose and particle and LET spectra. Preliminary results of absorbed dose measurements in the EURECA dosimeter packages are reported and compared to results of the LDEF experiments. The highest dose rate measured on EURECA is 63.3 plus or minus 0.4 mGy d(exp -1) behind a shielding thickness of 0.09 g cm(exp -2) in front of the detector package.

Reitz, G.↗

Orthogonal potency analysis of mesenchymal stromal cell function during ex vivo expansion

Highlights: • MSC potencies for their different functions are not identically affected by age. • In vitro age can strongly predict MSC adipogenic and hematopoietic-supporting potencies. • MSC shape can also strongly predict for hematopoietic-supporting potency. Adult bone marrow mesenchymal stromal cells (MSCs) have cross-functional, intrinsic potency that is of therapeutic interest. Their ability to regenerate bone, fat, and cartilage, modulate the immune system, and nurture the growth and function of other bone marrow hematopoietic stem/progenitor cells have all been evaluated by transplant applications of MSCs. These applications require the isolation and expansion scaled cell production. To investigate biophysical properties of MSCs that can be feasibly utilized as predictors of bioactivity during biomanufacturing, we used a low-density seeding model to drive MSCs into proliferative stress and exhibit the hallmark characteristics of in vitro aging. A low-density seeding method was used to generate MSCs from passages 1–7 to simulate serial expansion of these cells to maximize yield from a single donor. MSCs were subjected to three bioactivity assays in parallel to ascertain whether patterns in MSC age, size, and shape were associated with the outcomes of the potency assays. MSC age was found to be a predictor of adipogenesis, while cell and nuclear shape was strongly associated to hematopoietic-supportive potency. Together, these data evaluate morphological changes associated with cell potency and highlight new strategies for purification or alternatives to assessing MSC quality.

60 APPLIED LIFE SCIENCES↗

IER 489: Critical Unresolved Region Integral Experiment (CURIE) CEDT Phase-2 Final Design

The final design for the CURIE integral benchmark experiment is presented in this report. Measurements will be performed on the Comet vertical assembly machine and include various critical configurations consisting of High Enriched Uranium (HEU) metal plates and Teflon moderator plates surrounded by a thick copper reflector. The various configurations with different Teflon plate thickness planned allow for complimentary measurements with differing nuclear data sensitivity in the Unresolved Resonance Region (URR). Similar to previously performed Zeus experiments, the proposed work will serve to validate vital nuclear data quantities and uncertainties and identify deficiencies in current radiation transport codes. Additionally, it will assess the applicability of optimization approaches to nuclear critical experiment design. The final experiment design is detailed in this report and includes design, optimization, uncertainty and continuous-energy nuclear data sensitivity analysis for the final experimental configurations that will provide the basis for a future benchmark evaluation intended for submission to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook [1]. This document discusses the method, approach, considerations and final design chosen with conclusions. It also includes cost and schedule. The basis and principles of this document come from the preliminary design report [2]. Section 2 discusses the content and potential impact; section 3 gives an overview of the nuclear data and unresolved resonance region; section 4 gives a summary of the work done during the preliminary design; section 5 discusses the machine learning method and principles used for final design; section 6 summaries the results from final design; section 7 provides conclusions and the range of configurations chosen to carry forward to experiment execution; and section 8 includes a summary of costs.

42 ENGINEERING↗

Benchmark Calculation for Surry Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 86

The experimental nuclear spectroscopic data for known nuclides of mass number 86 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc) have been evaluated and presented together with Adopted properties for levels and γ rays. New high-spin data are available for {sup 86}Se, {sup 86}Br, {sup 86}Kr, {sup 86}Sr, {sup 86}Y, {sup 86}Zr and {sup 86}Mo; and lifetime data for high-spin states in {sup 86}Y and {sup 86}Zr. No significant new data since the 2001 NDS for A=86 have been reported for {sup 86}Rb and {sup 86}Nb. No data are yet available for excited states in {sup 86}Ga and {sup 86}As. The decay scheme of radioactive {sup 86}Ge is unknown, while those for {sup 86}Ga, {sup 86}As, 47.4 min isomer of {sup 86}Y, {sup 86}Nb and {sup 86}Tc are deemed as incomplete. Isomerism in {sup 86}Nb remains unconfirmed. This work supersedes the data presented in the previous NDS evaluation of A=86 published by 2001Si43.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Speed and Memory Improvements to MCNP6 Delayed-Gamma Line Treatment

The delayed-gamma (DG) line-emission (line) sampling was first introduced into MCNPX in 2005. At the time, storage demands for problems with large numbers of DG lines was a major concern. In order to accommodate large amounts of line data while keeping the memory footprint of such a problem from exceeding memory limits, complicated logic was included to sift through various storage options. In mid-2015 concerns arose over the adequacy of the MCNP6 DG source option (inherited from MCNPX) with line sampling for modeling high-fidelity problems. One indication that there was a problem came when studying the MCNP6 produced DG spectra of U-238 and its progeny using high-fidelity spectroscopic tallies when compared to DG line amplitudes directly from ENDF/B-VII.1 emission data. Despite producing a correct integral number of gammas, the comparison to ENDF data showed a broadening in the energy lines and a reduction in the amplitude of more prominent lines. It was later found that the cause of this broadening was one of the memory-saving techniques used to store DG line data when problems required many DG lines. Specifically, the DG lines were integrated into fine energy bins for sampling. When a DG line was to be sampled, a random number would be used to choose which energy bin to sample based on emission probability. Once chosen, a second random number was used to perform nearest-line sampling in that bin. The integration of lines led to an oversampling of low-probability lines, especially when in close proximity to high-probability lines. This treatment also caused a similar issue with the time-dependent behavior of DG line emission which occurred when low-probability lines were sampled near high probability lines with the former decay constant being used. The effect on time-dependent gamma production was demonstrated in analytic benchmarks performed by Weldon et al.. To address these issues a new gamma line storage and sampling treatment was introduced in 2015. This new treatment, stores gamma emission data in a line-by-line CDF which is sampled directly, thereby resolving both the line-broadening issue, and the time-dependence issue as was demonstrated by Tutt el al.. In addition, the new DG sampling treatment was written to use dynamically dimensioned storage arrays as opposed to large fixed-dimensioned arrays, as in the former treatment, and also makes more efficient use of line data that is stored by reducing or eliminating repeated data. As a result, storage arrays are generated only for DG data relevant to the problem being executed. The result should be a reduction in both memory requirements and runtime. However, these reductions could not be realized until the logic for the old treatment could be removed. This paper provides an update on recent work which has focused on the removal of the old DG sampling logic and attempts to quantify the memory reduction and speed up of selected problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On a measurement approach to support evaluation of thermal scattering law data

Inelastic thermal neutron scattering in materials that act as neutron moderators, reflectors, and filters results in shaping the neutron spectrum at low energies. This phenomenon is described using differential scattering cross sections calculated from three components including the bound atom (i.e., nuclear) scattering cross section of the neutron, the ratio of the outgoing and incoming neutron energy, and the thermal scattering law (TSL), i.e., S(α,β), where α and β represent dimensionless momentum and energy exchange variables, respectively. To date, no TSL libraries are generated using measured data. However, valuable information may be derived from measurements and “targeted” experiments that can validate TSL data and the related inelastic scattering cross sections. As a demonstration, a suite of coordinated measurements and experiments is described that was designed and used to support the evaluation of the TSL for “nuclear” graphite. This experimental suite includes neutron powder diffraction (for structure analysis), positron annihilation (for nano porosity assessment), inelastic neutron scattering measurements using a chopper spectrometer, transmission experiments using neutrons with energy below the Bragg cutoff thereby accessing the total (inelastic) cross section, and a slowing-downtime experiment to observe the developing neutron spectrum in the material. We find that this experimental suite was key to understanding the difference in TSL between “nuclear” and “ideal” graphite and for the inclusion of “nuclear” graphite in the ENDF/B-VIII.0 nuclear data library release.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Corrective Action Investigation Plan for Corrective Action Unit 375: Area 30 Buggy Unit Craters, Nevada Test Site, Nevada

Corrective Action Unit (CAU) 375 is located in Areas 25 and 30 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 375 comprises the two corrective action sites (CASs) listed below: • 25-23-22, Contaminated Soils Site • 30-45-01, U-30a, b, c, d, e Craters Existing information on the nature and extent of potential contamination present at the CAU 375 CASs is insufficient to evaluate and recommend corrective action alternatives (CAAs). This document details an investigation plan that will provide for the gathering of sufficient information to evaluate and recommend CAAs. Corrective Action Site 25-23-22 is composed of the releases associated with nuclear rocket testing at Test Cell A (TCA). Test Cell A was used to test and develop nuclear rocket motors as part of the Nuclear Rocket Development Station from its construction in 1958 until 1966, when rocket testing began being conducted at Test Cell C. The rocket motors were built with an unshielded nuclear reactor that produced as much as 1,100 kilowatts (at full power) to heat liquid hydrogen to 4,000 degrees Fahrenheit, at which time the expanded gases were focused out a nozzle to produce thrust. The fuel rods in the reactor were not clad and were designed to release fission fragments to the atmosphere, but due to vibrations and loss of cooling during some operational tests, fuel fragments in excess of planned releases became entrained in the exhaust and spread in the immediate surrounding area. Cleanup efforts have been undertaken at times to collect the fuel rod fragments and other contamination. Previous environmental investigations in the TCA area have resulted in the creation of a number of use restrictions. The industrial area of TCA is encompassed by a fence and is currently posted as a radioactive material area. Corrective Action Site 30-45-01 (releases associated with the Buggy Plowshare test) is located in Area 30 on Chukar Mesa. It was a Plowshare test where five nuclear devices were buried 140 feet (ft) deep in a row at 150-ft intervals. These devices were detonated on March 12, 1968, to produce a trench 254 ft wide, 865 ft long, and 70 ft deep. The mesa where the test was conducted is surrounded on three sides by ravines, and the entire end of the mesa is fenced and posted as a contamination area. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend CAAs. Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on December 2, 2009, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 375.

54 ENVIRONMENTAL SCIENCES↗

PROVIDING PLANT DATA ANALYTICS THROUGH A SEAMLESS DIGITAL ENVIRONMENT

As technology continues to evolve and become more integrated into a worker’s daily routine in the Nuclear Power industry the need for easy access to data becomes a priority. Not only does the need for data increase but the amount of data collected increases. In most cases the data is collected and stored in various software applications, many of which are legacy systems, which do not offer any other option to access the data except through the application’s user interface. Furthermore the data gets grouped in “silos” according to work function and not necessarily by subject. Hence, in order to access all the information needed for a particular task or analysis one may have to access multiple applications to gather all the data needed. The industry and the research community have identified the need for a digital architecture and more importantly the need for a Seamless Digital Environment. An SDE provides a means to access multiple applications, gather the data points needed, conduct the analysis requested, and present the result to the user with minimal or no effort by the user. In addition, the nuclear utilities have identified the need for research focused on data analytics. The effort should develop and evaluate use cases for data mining and analytics for employing information from plant sensors and database for use in developing improved business analytics. Idaho National Laboratory is leading such effort, which is conducted in close collaboration with vendors, nuclear utilities, Institute of Nuclear Power Operations, and Electric Power Research Institute. The goal of the study is to research potential approaches to building an analytics solution for equipment reliability, on a small scale, focusing on either a single piece of equipment or a single system. The analytics solution will likely consist of a data integration layer, predictive and machine learning layer and the user interface layer that will display the output of the analysis in a straight forward, easy to consume manner. This paper will describe the study and the initial results.

47 OTHER INSTRUMENTATION↗