Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Impact of GMI All-Sky Radiance Assimilation in the NASA GEOS Forecast System

The assimilation of cloud- and precipitation-affected ("all-sky") radiances has become an important focus of development at most numerical weather prediction centers. Efforts at the Global Modeling and Assimilation Office (GMAO) have focused on all-sky assimilation of GPM Microwave Imager (GMI) radiances, which became operational in the GEOS real-time production system in July 2018. Implementation of the all-sky capability required several upgrades to the GEOS hybrid 4D-EnVar assimilation infrastructure including the addition of control variables for cloud liquid, cloud ice, rain and snow, enhancements to the radiative transfer model, new hybrid background and observational error models, and modified quality control and bias correction procedures. This talk describes the impact of GMI all-sky radiance assimilation on GEOS analyses and forecasts as determined from examination of various metrics including statistics of background departures and analysis increments, forecast skill scores, and forecast sensitivity observation impact (FSOI) calculations. It is shown that in addition to the hydrometeors themselves, the initial wind, temperature and pressure fields all undergo significant dynamic adjustment in response to the analyzed cloud and precipitation features. Assimilation of GMI radiances leads to improved forecasts of lower tropospheric wind, temperature and humidity, especially in the tropics. The largest forecast improvements occur during the first 48 hours, with diminishing impact thereafter. However, combining GMI all-sky assimilation with improvements to the GEOS model physics as in the recent implementation of the real-time production system, extends these forecast improvements well in to the medium range. FSOI results based on a 24-hr moist global energy norm show that GMI radiances provide nearly uniform beneficial impact throughout the tropics, with more mixed impacts in the subtropics. While the overall impact of GMI is smaller than that of other, much more numerous microwave and hyperspectral infrared radiance types, its impact is among the largest of all radiance types on a per-observation basis.

Gelaro, Ron↗

Cross‐Instrument Comparison of MapCam and OVIRS on OSIRIS‐REx

Two of the instruments onboard the OSIRIS-REx spacecraft, the MapCam color imager and the OVIRS visible and 20 infrared spectrometer, observed the surface of asteroid (101955) Bennu in partially overlapping wavelengths. 21 Significant scientific advances have been enabled by using data from these two instruments in tandem, but a robust 22 statistical understanding of their relationship is needed for future analyses to cross-compare their data as accurately 23 and sensitively as possible. Here we present a cross-instrument comparison of data acquired by MapCam and 24 OVIRS, including methods and results for all global and site-specific observation campaigns in which both 25 instruments were active. In our analysis, we consider both the absolute radiometric offset and the relative 26 (normalized) variation between the two instruments; we find that both depend strongly on the photometric and 27 instrumental conditions during the observation. The two instruments have a large absolute offset (>15%) due to their 28 independent radiometric calibrations. However, they are very consistent (relative offset as low as 1%) when each 29 instrument’s response is normalized at a single wavelength, particularly at low phase angles where shadows on 30 Bennu’s rough surface are minimized. We recommend using the global datasets acquired at 12:30 pm local solar 31 time for cross-comparisons; data acquired at higher phase angles have larger uncertainties.

D R Golish↗

Quantifying Pore Morphology in Spray-Formed Tantalum Using X-ray Micro-computed Tomography

In order to establish quantitative process–structure–property relationships in thermal spray coatings, a robust framework for defining (micro)structural characteristics is needed. Here, we present a quantitative characterization of the three-dimensional morphology of porosity in spray-formed tantalum samples based on high-resolution X-ray micro-computed tomography. Using synchrotron facilities, we acquired dozens of high-resolution scans, enabling a statistically meaningful comparison across multiple samples, different regions within samples, and spray processes. We quantify the spatial distribution, size, and topology of porous inclusions, with a significant focus on variability across samples and different spray processes (plasma and cold sprayed), as well as sensitivity to image segmentation and resolution. Based on a typical segmentation, we report porosities ranging from 0.9 to 1.7 pct for all samples tested, with significant sensitivity due to image segmentation resulting in estimates as low as 0.6 pct and as high as 4.8 pct. For the complex pore space morphology observed in these materials, we argue that a conventional analysis based on identifying individual pores is not well suited, and propose an alternative approach based on morphological metrics with a rich history in porous media literature, such as spatial correlations, local pore thickness, and scale-dependent sub-sampling. Spatial correlations indicate anisotropic splat structures, but only mildly anisotropic pores. Various measures of pore size show a wide distribution of sizes, ranging from sub-micron to 10-micron length scales. Scale-dependent variations in porosity suggest that representative volumes of several hundred microns are required for convergence of morphological metrics, with larger volumes for cold-spray materials. This work provides a robust quantitative basis for describing three-dimensional pore structure in thermal spray coatings.

36 MATERIALS SCIENCE↗

MALDI Orbitrap Mass Spectrometry Profiling of Dysregulated Sulfoglycosphingolipids in Renal Cell Carcinoma Tissues

Matrix-assisted laser desorption/ionization coupled with Orbitrap mass spectrometry (MALDI-Orbitrap-MS) is used for the clinical study of patients with renal cell carcinoma (RCC), as the most common type of kidney cancer. Significant changes in sulfoglycosphingolipid abundances between tumor and autologous normal kidney tissues are observed. First, sulfoglycosphingolipid species in studied RCC samples are identified using high mass accuracy full scan and tandem mass spectra. Subsequently, optimization, method validation, and statistical evaluation of MALDI-MS data for 158 tissues of 80 patients are discussed. More than 120 sulfoglycosphingolipids containing one to five hexosyl units are identified in human RCC samples based on the systematic study of their fragmentation behavior. Many of them are recorded here for the first time. Multivariate data analysis (MDA) methods, i.e., unsupervised principal component analysis (PCA) and supervised orthogonal partial least square discriminant analysis (OPLS-DA), are used for the visualization of differences between normal and tumor samples to reveal the most up- and downregulated lipids in tumor tissues. Obtained results are closely correlated with MALDI mass spectrometry imaging (MSI) and histologic staining. Important steps of the present MALDI-Orbitrap-MS approach are also discussed, such as the selection of best matrix, correct normalization, validation for semiquantitative study, and problems with possible isobaric interferences on closed masses in full scan mass spectra. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-D-16A-01: Medical Physics Workshop: Editorial Vision and Guidance On Writing and Reviewing Papers

On January 1, 2014, editorial leadership of Medical Physics passed from esteemed long-time Editor Bill Hendee to a collective editorial group composed of the three presenters listed above. In this presentation, we would like to outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. Vision for Medical Physics and current initiatives: Jeff Williamson, Editor-in-Chief We cannot improve on Dr. Hendee's succinct vision statement “to continue the Journal's tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be s the preeminent forum for electronic exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; or (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities we face are: are electronic-only and open access publishing; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. To address these issues over the next 3 years, we have reduced the size of our Editorial Board and focused its efforts on improving the Journal's impact through 4 working groups (WGs): WG-1: Review process quality and selectivity Creation of 120 member Board of Associate Editors to improve review uniformity by placing Ms. management in fewer hands New reviewer guidelines and templates Answer: “what is the scope of medical physics research?” Recursive taxonomy for tagging review expertise and article contents WG-2 Improving reader experience Redesigning http://MedPhys.org to host interactive features and gateway to electronic issue archive Experimentation with interactive features beginning with “Point/Counterpoint” Data mining and Journal quality evaluation Find out who are audiences are Identify characteristics of high impact articles Measure effectiveness of innovations Outreach to related communities Special issues presenting high-impact work in designated subcommunities Addressing the needs of new research constituencies: engineers, biophysicists, clinicians Guidelines and templates for reviewers and associate editors: Shiva Das, Therapy Physics Editor We will discuss the Med. Phys. review process and a new initiative to create review templates that attempts to address current shortcomings. Template design is informed by the literature on of the review process effectiveness and practices of other journals. Its goals are to provide authors more constructive criticism to improve the manuscript; quantifying perceived importance and potential impact; and providing structured sections that prompt the reviewer to addresses important technical and editorial elements. While the template is recommended to be used, reviewers could alternatively enter their comments in the older free-form style. The expectations of the template are that it will enable consistently thorough, high quality reviews that accurately separate acceptable vs. substandard submissions but continue our tradition of helping authors to enhance papers with high potential. Ultimately, the goal is to reduce variability and subjectivity in the peer-review process, in turn leading to articles with higher research and clinical impact. We will also discuss interesting perspectives from several journals on aspects of the peer-review process such as public input via comments, influence of author-suggested reviewers, and bias in reviewer selection. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics Ms. must include a clear and concise statement of the novelty and clinical and/or scientific importance of their work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; or first demonstration that an existing engineering solution solves a clinical problem. Authors must also include: sufficient background information and rationale; enough detail that the work can be reproduced by others; sufficient statistical analysis to refute or validate their hypothesis, how it compares to; is distinct from, and improves upon others' work; and the limitations of their study. When the authors receive critiques from the referees and associate editor, the authors should provide a detailed point-bypoint response to each comment. We now ask that the authors' rebuttal include the text of the original criticism, the authors' response, and the modified text along with the line numbers in the revised article. We also ask that the new text be highlighted in a different font color in the revised submission. These changes and others will be discussed. Their purpose is to facilitate the review process.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Remote measurement of in-plane diffusivity components in plates

A method of determining thermal diffusivity in thin plates is presented. The method, using infrared images of evolving thermal patterns previously injected with a laser, is noncontacting, one-sided, and remote. It does not require independent estimates of either the emissivity of the sample or the sample thickness. With a line-segment pattern for thermal input, it yields the inplane components of the diffusivity tensor in anisotropic materials and also the rate of heat loss to the environment of the plate. Two methods of data analysis are presented, one corresponding to a heating line of general cross section and the other considering a Gaussian cross section, thereby saving considerable computer time. Both methods produce a statistical evaluation of measurement quality as well as estimates of diffusivity and loss rate. Results are shown for plates of metals and graphite-epoxy composite materials. Principal components and orientation for the diffusivity tensor are obtained in the anisotropic graphite-epoxy sample.

Welch, Christopher S.↗

Tropical Cirrus Physical and Radiation Characteristics from the NASA Aircraft Observations in Toga/Coare

During the Toga/Coare experiment in the tropical west Pacific, a cloud radiation experiment involving measurement from the NASA ER-2 high altitude aircraft and DC-8 airborne laboratory was performed. Observations include multispectral visible/IR and microwave radiometric imaging, active lidar profiling and radiation flux measurements. On a number of missions coordinated flights were made for simultaneous cloud observations with the ER-2 remote sensing and DC-8 below cloud and in cloud measurements. Since the field experiment there has been systematic analysis of the observations. Intercomparison of retrieved measurements will be presented. These include the relation between visible bi-directional reflectivity and infrared emissivity of tropical cirrus. Upper troposphere microwave water vapor retrievals and cirrus optical parameters have been correlated. The relation observed short wave flux divergence to retrieved cloud thickness and type has been studied. Calculations and statistics for the short and long wave heating profiles of observed clouds have been derived. A summary of key results will be presented.

Spinhirne, James D.↗

Anomaly Detection for the Roman Space Telescope Wide Field Instrument’s Science Data Processing Pipeline

The Roman Space Telescope (RST) Wide Field Instrument (WFI) will be utilizing a preliminary Science Data Processing (SDP) pipeline during its Integration and Test, and to some extent during Operations, to track basic statistics and identify known features such as cosmic rays, snowballs as well as possible anomalies in raw detector data. In our detectors, these anomalies appear as jumps in the ramp of a readout and are classified as cosmic rays if they appear as a streak or snowballs if they’re more circular. The WFI employs an array of 18 H4RG-10 detectors that collect image samples. Each set of raw frames within a non-destructive exposure is packaged by the SDP pipeline into image cubes for each detector. Each cube is a time series of 4096 × 4096 accumulating pixel frames. The preliminary analysis pipeline is used to locate anomalies in these time-series accumulation frames and identify the type of anomaly, either natural phenomena or detector characteristic. To compare different methods, we’ve implemented both heuristic-based and data-driven methods to identify anomalies. For the heuristic-based approach, we identify snowballs and cosmic rays by the size and shape of outlier pixel clusters between consecutive frames. For data driven methods, we evaluated a Convolutional Neural Network (CNN) model, and more traditional methods like Principal Component Analysis (PCA). CNN is a supervised learning/classification method. Thus, we used a labeled dataset of anomalies to perform segmentation of the image and identify anomalies. We used previously identified cosmic rays and snowballs to measure the accuracy and efficiency of the mentioned approaches. In evaluating these methods, we aim to pick the best fit for the SDP pipeline’s anomaly detection in terms of both performance and runtime.

Paul Horton↗

Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance

Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a “redder” NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose){sup −β} with the component β ≈ 0.25, which violated the classical σ ∝ (dose){sup −0.5} power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. Conclusions: The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE ADVANCED CAMERA FOR SURVEYS GENERAL CATALOG: STRUCTURAL PARAMETERS FOR APPROXIMATELY HALF A MILLION GALAXIES

We present the Advanced Camera for Surveys General Catalog (ACS-GC), a photometric and morphological database using publicly available data obtained with the Advanced Camera for Surveys (ACS) instrument on the Hubble Space Telescope. The goal of the ACS-GC database is to provide a large statistical sample of galaxies with reliable structural and distance measurements to probe the evolution of galaxies over a wide range of look-back times. The ACS-GC includes approximately 470,000 astronomical sources (stars + galaxies) derived from the AEGIS, COSMOS, GEMS, and GOODS surveys. GALAPAGOS was used to construct photometric (SEXTRACTOR) and morphological (GALFIT) catalogs. The analysis assumes a single Sersic model for each object to derive quantitative structural parameters. We include publicly available redshifts from the DEEP2, COMBO-17, TKRS, PEARS, ACES, CFHTLS, and zCOSMOS surveys to supply redshifts (spectroscopic and photometric) for a considerable fraction ({approx}74%) of the imaging sample. The ACS-GC includes color postage stamps, GALFIT residual images, and photometry, structural parameters, and redshifts combined into a single catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-H-207A-03: The Universality of the Lognormal Behavior of [F-18]FLT PET SUV Measurements

Purpose: Log transforming [F-18]FDG PET standardized uptake values (SUVs) has been shown to lead to normal SUV distributions, which allows utilization of powerful parametric statistical models. This study identified the optimal transformation leading to normally distributed [F-18]FLT PET SUVs from solid tumors and offers an example of how normal distributions permits analysis of non-independent/correlated measurements. Methods: Forty patients with various metastatic diseases underwent up to six FLT PET/CT scans during treatment. Tumors were identified by nuclear medicine physician and manually segmented. Average uptake was extracted for each patient giving a global SUVmean (gSUVmean) for each scan. The Shapiro-Wilk test was used to test distribution normality. One parameter Box-Cox transformations were applied to each of the six gSUVmean distributions and the optimal transformation was found by selecting the parameter that maximized the Shapiro-Wilk test statistic. The relationship between gSUVmean and a serum biomarker (VEGF) collected at imaging timepoints was determined using a linear mixed effects model (LMEM), which accounted for correlated/non-independent measurements from the same individual. Results: Untransformed gSUVmean distributions were found to be significantly non-normal (p<0.05). The optimal transformation parameter had a value of 0.3 (95%CI: −0.4 to 1.6). Given the optimal parameter was close to zero (which corresponds to log transformation), the data were subsequently log transformed. All log transformed gSUVmean distributions were normally distributed (p>0.10 for all timepoints). Log transformed data were incorporated into the LMEM. VEGF serum levels significantly correlated with gSUVmean (p<0.001), revealing log-linear relationship between SUVs and underlying biology. Conclusion: Failure to account for correlated/non-independent measurements can lead to invalid conclusions and motivated transformation to normally distributed SUVs. The log transformation was found to be close to optimal and sufficient for obtaining normally distributed FLT PET SUVs. These transformations allow utilization of powerful LMEMs when analyzing quantitative imaging metrics.

60 APPLIED LIFE SCIENCES↗

SU-F-R-25: Automatic Identification of Suspicious Recurrent/residual Disease Regions After Prostatectomy

Purpose: To automatically identify and outline suspicious regions of recurrent or residual disease in the prostate bed using Dynamic Contrast Enhanced-MRI (DCE-MRI) in patients after prostatectomy. Methods: Twenty-two patients presenting for salvage radiotherapy and with identified Gross Tumor Volume (GTV) in the prostate bed were retrospectively analyzed. The MRI data consisted of Axial T2weighted-MRI (T2w) of the pelvis: resolution 1.25×1.25×2.5 mm; Field of View (FOV): 320×320 mm; slice thickness=2.5mm; 72 slices; and Dynamic Contrast Enhanced MRI (DCE-MRI)–12 series of T1w with identical spatial resolution to T2w and at 30–34s temporal resolution. Unsupervised pattern recognition was used to decompose the 4D DCE data as the product W.H of weights W of k patterns H. A well-perfused pattern Hwp was identified and the weight map Wwp associated to Hwp was used to delineate suspicious volumes. Threshold of Wwp set at mean(Wwp)+S*std(Wwp), S=1,1.5,2 and 2.5 defined four volumes labeled as DCE1.0 to DCE2.5. These volumes were displayed on T2w and, along with GTV, were correlated with the highest pre-treatment PSA values, and with pharmacokinetic analysis constants. Results: GTV was significantly correlated with DCE2.0(ρ= 0.60, p<0.003), and DCE 2.5 (ρ=0.58, p=0.004)). Significant correlation was found between highest pre-treatment PSA and GTV(ρ=0.42, p<0.049), DCE2.0(ρ= 0.52, p<0.012), and DCE 2.5 (ρ=0.67, p<<0.01)). Kruskal-Wallis analysis showed that Ktrans median value was statistically different between non-specific prostate bed tissue NSPBT and both GTV (p<<0.001) and DCE2.5 (p<<0.001), but while median Ve was statistically different between DCE2.5 and NSPBT (p=0.002), it was not statistically different between GTV and NSPBT (p=0.054), suggesting that automatic volumes capture more accurately the area of malignancy. Conclusion: Software developed for identification and visualization of suspicions regions in DCE-MRI from post-prostatectomy patients has been validated by PSA and pharmacokinetic constants analysis showing that it generates clinically relevant volumes.

60 APPLIED LIFE SCIENCES↗

Guide to Using Onionskin Analysis Code (U)

This document is a guide to using R-code written for the purpose of analyzing onionskin experiments. We expect the user to be very familiar with statistical methods and the R programming language. For more details about onionskin experiments and the statistical methods mentioned in this document see Storlie, Fugate, et al. (2013). Engineers at LANL experiment with detonators and high explosives to assess performance. The experimental unit, called an onionskin, is a hemisphere consisting of a detonator and a booster pellet surrounded by explosive material. When the detonator explodes, a streak camera mounted above the pole of the hemisphere records when the shock wave arrives at the surface. The output from the camera is a two-dimensional image that is transformed into a curve that shows the arrival time as a function of polar angle. The statistical challenge is to characterize a baseline population of arrival time curves and to compare the baseline curves to curves from a new, so-called, test series. The hope is that the new test series of curves is statistically similar to the baseline population.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Prospective Comparison of the Effects of Interfractional Variations on Proton Therapy and Intensity Modulated Radiation Therapy for Prostate Cancer

Purpose: To quantify and compare the impact of interfractional setup and anatomic variations on proton therapy (PT) and intensity modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Twenty patients with low-risk or intermediate-risk prostate cancer randomized to receive passive-scattering PT (n=10) and IMRT (n=10) were selected. For both modalities, clinical treatment plans included 50.4 Gy(RBE) to prostate and proximal seminal vesicles, and prostate-only boost to 79.2 Gy(RBE) in 1.8 Gy(RBE) per fraction. Implanted fiducials were used for prostate localization and endorectal balloons were used for immobilization. Patients in PT and IMRT arms received weekly computed tomography (CT) and cone beam CT (CBCT) scans, respectively. The planned dose was recalculated on each weekly image, scaled, and mapped onto the planning CT using deformable registration. The resulting accumulated dose distribution over the entire treatment course was compared with the planned dose using dose-volume histogram (DVH) and γ analysis. Results: The target conformity index remained acceptable after accumulation. The largest decrease in the average prostate D{sub 98} was 2.2 and 0.7 Gy for PT and IMRT, respectively. On average, the mean dose to bladder increased by 3.26 ± 7.51 Gy and 1.97 ± 6.84 Gy for PT and IMRT, respectively. These values were 0.74 ± 2.37 and 0.56 ± 1.90 for rectum. Differences between changes in DVH indices were not statistically significant between modalities. All volume indices remained within the protocol tolerances after accumulation. The average pass rate for the γ analysis, assuming tolerances of 3 mm and 3%, for clinical target volume, bladder, rectum, and whole patient for PT/IMRT were 100/100, 92.6/99, 99.2/100, and 97.2/99.4, respectively. Conclusion: The differences in target coverage and organs at risk dose deviations for PT and IMRT were not statistically significant under the guidelines of this protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective, Open-Label, Multicenter Phase 2 Trial of Neoadjuvant Therapy Using Full-Dose Gemcitabine and S-1 Concurrent with Radiation for Resectable Pancreatic Ductal Adenocarcinoma

Background: Neoadjuvant therapy reportedly shows only marginal clinical benefit in pancreatic ductal adenocarcinoma (PDAC), especially in resectable cases. However, with more effective regimens, neoadjuvant therapy may become a standard of care for resectable cases. A prospective, open-label, multicenter phases 1 and 2 trial of neoadjuvant therapy was conducted using full-dose gemcitabine and S-1 concurrently with 50.4 Gy of radiation therapy (GSRT) for resectable PDAC. This report describes the phase 2 results. Methods: The phase 2 part of this study enrolled 57 patients with cytologically or histologically proven PDAC deemed resectable based on imaging before neoadjuvant therapy. These patients received GSRT. After reevaluation by computed tomography scan, surgical exploration was performed, followed by adjuvant therapy. According to the prescribed protocol of the clinical trial, statistical analyses included 57 phase 2 patients and 6 phase 1 patients who received the same dosage as in phase 2. Results: This trial enrolled 63 patients (42 men and 21 women) with a median age of 70 years. Leukopenia or neutropenia of grade 3 or higher occurred for 79% of the patients, but no other severe adverse events were observed. Among the 63 patients, 54 underwent surgical resection. Intention-to-treat analysis of the 63 patients showed an excellent median survival time lasting as long as 55.3 months. The patients who completed neoadjuvant therapy, surgery, and adjuvant therapy had a 5-year survival rate of 56.6%. Conclusions: This regimen showed outstanding clinical efficacy with acceptable tolerability for patients with resectable PDAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating LES for Jet Aeroacoustics

Engineers charged with making jet aircraft quieter have long dreamed of being able to see exactly how turbulent eddies produce sound and this dream is now coming true with the advent of large eddy simulation (LES). Two obvious challenges remain: validating the LES codes at the resolution required to see the fluid-acoustic coupling, and the interpretation of the massive datasets that result in having dreams come true. This paper primarily addresses the former, the use of advanced experimental techniques such as particle image velocimetry (PIV) and Raman and Rayleigh scattering, to validate the computer codes and procedures used to create LES solutions. It also addresses the latter problem in discussing what are relevant measures critical for aeroacoustics that should be used in validating LES codes. These new diagnostic techniques deliver measurements and flow statistics of increasing sophistication and capability, but what of their accuracy? And what are the measures to be used in validation? This paper argues that the issue of accuracy be addressed by cross-facility and cross-disciplinary examination of modern datasets along with increased reporting of internal quality checks in PIV analysis. Further, it is argued that the appropriate validation metrics for aeroacoustic applications are increasingly complicated statistics that have been shown in aeroacoustic theory to be critical to flow-generated sound.

Bridges, James↗

Galaxy–galaxy lensing with the DES-CMASS catalogue: measurement and constraints on the galaxy-matter cross-correlation

ABSTRACT The DMASS sample is a photometric sample from the DES Year 1 data set designed to replicate the properties of the CMASS sample from BOSS, in support of a joint analysis of DES and BOSS beyond the small overlapping area. In this paper, we present the measurement of galaxy–galaxy lensing using the DMASS sample as gravitational lenses in the DES Y1 imaging data. We test a number of potential systematics that can bias the galaxy–galaxy lensing signal, including those from shear estimation, photometric redshifts, and observing conditions. After careful systematic tests, we obtain a highly significant detection of the galaxy–galaxy lensing signal, with total S/N = 25.7. With the measured signal, we assess the feasibility of using DMASS as gravitational lenses equivalent to CMASS, by estimating the galaxy-matter cross-correlation coefficient rcc. By jointly fitting the galaxy–galaxy lensing measurement with the galaxy clustering measurement from CMASS, we obtain $r_{\rm cc}=1.09^{+0.12}_{-0.11}$ for the scale cut of $4 \, h^{-1}{\rm \,\,Mpc}$ and $r_{\rm cc}=1.06^{+0.13}_{-0.12}$ for $12 \, h^{-1}{\rm \,\,Mpc}$ in fixed cosmology. By adding the angular galaxy clustering of DMASS, we obtain rcc = 1.06 ± 0.10 for the scale cut of $4 \, h^{-1}{\rm \,\,Mpc}$ and rcc = 1.03 ± 0.11 for $12 \, h^{-1}{\rm \,\,Mpc}$. The resulting values of rcc indicate that the lensing signal of DMASS is statistically consistent with the one that would have been measured if CMASS had populated the DES region within the given statistical uncertainty. The measurement of galaxy–galaxy lensing presented in this paper will serve as part of the data vector for the forthcoming cosmology analysis in preparation.

79 ASTRONOMY AND ASTROPHYSICS↗