Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parametric Operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

Assessing Tactical Scheduling Options for Time-Based Surface Metering

This paper presents a parametric analysis of the most recent tactical scheduler design for NASA’s Airspace Technology Demonstration 2 (ATD-2) sub-project, committed to demonstrating time-based surface metering at Charlotte Douglas International Airport (CLT). The tactical scheduler design is implemented in a fast-time simulation model of CLT using NASA’s Surface Operations Simulator and Scheduler. The tactical scheduler is supported by three basic functions: trajectory prediction, runway scheduling, and advisory generation. A key parameter of the advisory generation function is the taxi time delay buffer used when calculating target gate pushback times from runway schedule. Multiple simulations that varied the amount of taxi time delay buffer were analyzed to determine the effect on tactical scheduler performance. The results show an improvement in tactical scheduler performance when the buffer is made sufficiently large to release departures from their gates early enough to maintain scheduler predicted runway throughput.

Zelinski, Shannon↗

Systems and methods for screening particle source manufacturing and development test data

A computing system obtains test data for a particle source. The test data was generated by the particle source when the particle source was caused to emit particles. The test data comprises a first set of measurements of a first type and a second set of measurements of a second type. The computing system applies a data agnostic predictive model to the test data. The data agnostic predictive model is generated without a parametric analysis of variables of the first type and variables of the second type. The data agnostic predictive model outputs, based upon the test data, a value that is indicative of whether or not the test data is abnormal. Based upon the value, the computing system outputs an indication that the particle source was operating sub-optimally when emitting the particles.

Multari, Rosalie A.↗

Parametric Cost Model for Ground and Space Telescopes

Parametric cost models can be used by designers and project managers to compare cost between major architectural cost drivers and allow high-level design trades; enable cost-benefit analysis for technology development investment; and, provide a basis for estimating total project cost between related concepts. The NASA Marshall Space Flight Center has developed a 5-parameter first-article optical telescope assembly cost model OTA$ (FY17) = $20M x 30(S/G)x D(1.7)x λ(-0.5)x T(-0.25)x e(-0.028) (Y-1960)Where S/G = 1 for space and 0 for ground telescopes, D = diameter, λ= diffraction limited wavelength, T = operating temperature and Y = year of development. The model explains 92% (Adjusted R2) of the cost variation in a database of 47 total ground and space telescope assemblies (OTA). The MSFC model estimates the most likely cost for only the OTA. Where an OTA is defined as the subsystem which collects electromagnetic radiation and focuses it (focal) or concentrates it (afocal) into the science instruments. An OTA consists of the primary mirror, secondary mirror, auxiliary optics and support structure (such as optical bench or truss structure, primary support structure, secondary support structure or spiders, straylight baffles, mechanisms for adjusting the optical components, electronics or power systems for operating these mechanisms, etc.). Finally, duplication only reduces cost for the manufacture of identical systems(i.e. multiple aperture sparse arrays or interferometers). And, while duplication does reduce the cost of manufacturing the mirrors of segmented primary mirror, this cost savings does not appear to manifest itself in the final primary mirror assembly(presumably because the structure for a segmented mirror is more complicated than for a monolithic mirror).

Space Telescope Cost Model, Parametric Cost Model↗

Development of a Multivariable Parametric Cost Analysis for Space-Based Telescopes

Over the past 400 years, the telescope has proven to be a valuable tool in helping humankind understand the Universe around us. The images and data produced by telescopes have revolutionized planetary, solar, stellar, and galactic astronomy and have inspired a wide range of people, from the child who dreams about the images seen on NASA websites to the most highly trained scientist. Like all scientific endeavors, astronomical research must operate within the constraints imposed by budget limitations. Hence the importance of understanding cost: to find the balance between the dreams of scientists and the restrictions of the available budget. By logically analyzing the data we have collected for over thirty different telescopes from more than 200 different sources, statistical methods, such as plotting regressions and residuals, can be used to determine what drives the cost of telescopes to build and use a cost model for space-based telescopes. Previous cost models have focused their attention on ground-based telescopes due to limited data for space telescopes and the larger number and longer history of ground-based astronomy. Due to the increased availability of cost data from recent space-telescope construction, we have been able to produce and begin testing a comprehensive cost model for space telescopes, with guidance from the cost models for ground-based telescopes. By separating the variables that effect cost such as diameter, mass, wavelength, density, data rate, and number of instruments, we advance the goal to better understand the cost drivers of space telescopes.. The use of sophisticated mathematical techniques to improve the accuracy of cost models has the potential to help society make informed decisions about proposed scientific projects. An improved knowledge of cost will allow scientists to get the maximum value returned for the money given and create a harmony between the visions of scientists and the reality of a budget.

Dollinger, Courtnay↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Study of Solid Amine Sorbents for the Capture of Carbon Dioxide

Solid amine sorbents were prepared using mixtures of linear and branched primary, secondary, and tertiary amines. These amines were immobilized within polystyrene (PS)-, silicon dioxide (SiO 2 )-, or polymethylmethacrylate (PMMA)-based substrates at various weight ratios. Testing was conducted in various reactor systems, where the reactive water required for the capture of carbon dioxide (CO 2 ) was tracked during the adsorption/desorption cycles by mass spectrometer gas analysis. The water management for these sorbents was quantified and used to assess the technical feasibility of the operating conditions for the capture of CO 2 from simulated flue gas streams. In addition, the heats of reaction and performance capture loading capacities of these sorbents were also determined by differential scanning calorimetry (DSC) and thermogravimetric analyses (TGAs), respectively, in both dry and humidified CO 2 gas streams. The regenerable solid amine sorbents investigated in this study exhibit acceptable CO 2 -capture loading capacities of 2.5-3.5 mol of CO 2 /kg of sorbent by TGA and a laboratory-scale fixed-bed reactor. These sorbents were stable over the adsorption/desorption temperature range of 25-105° C for 10-cyclic tests. According to the DSC analysis, the heat of reaction generated by these sorbents was in the range of 400-600 Btu/lb. CO 2 , which will require a reactor with heat management capabilities.

01 COAL, LIGNITE, AND PEAT↗

Comparison of box-wing and conventional aircraft mission performance using multidisciplinary analysis and optimization

Box-wing aircraft designs have the potential to achieve significant reductions in fuel consumption. Closed non-planar wing designs have been shown to reduce induced drag and the statically indeterminate wing structure can lead to reduced wing weight. In addition, the streamwise separation of the two main wings can provide the moments necessary for static stability and control, eliminating the weight and aerodynamic drag of a horizontal tail. Proper assessment of the disciplinary interactions in box-wing designs is essential to determine any realistic performance benefits arising from the use of such a configuration. This study analyzes both box-wing and conventional aircraft designed for representative regional-jet missions. A preliminary parametric investigation shows a lift-to-drag ratio advantage for box-wing designs, while a more detailed multidisciplinary study indicates that the requirement to carry the mission fuel in the wings leads to an increase of between 5% and 1% in total fuel burn compared to conventional designs. Furthermore, the multidisciplinary study identified operating conditions where the box-wing can have superior performance to conventional aircraft despite the fuel volume constraint.

42 ENGINEERING↗

Note: A kinematic shaker system for high amplitude, low frequency vibration testing

This note describes a shaker system capable of high peak-velocity, large amplitude, low frequency, near-sinusoidal excitation that has been constructed and employed in experiments on the inhibition of Rayleigh-Bénard convection using acceleration modulation. The production of high peak-velocity vibration is of interest in parametric excitation problems of this type and reaches beyond the capabilities of standard electromagnetic shakers. The shaker system described employs a kinematic linkage to two counter-rotating flywheels, driven by a variable-speed electrical motor, producing peak-to-peak displacements of 15.24 cm to a platform mounted on two guide rails. In operation, this shaker has been demonstrated to produce peak speeds of up to 3.7 m/s without failure.

Swaminathan, Anand↗

Flux-pumped impedance-engineered broadband Josephson parametric amplifier

Broadband quantum-limited amplifiers play a critical role in the single-shot readout of superconducting qubits, but a popular implementation, the traveling wave parametric amplifier, involves a complex design and fabrication process. Here, we present a simple design for a Josephson parametric amplifier, using a lumped element resonator comprising a superconducting quantum interference device whose useful bandwidth is enhanced with an on-chip impedance-matching circuit. Additionally, we demonstrate a flux-coupling geometry that maximizes the coupling to the Josepson loop and minimizes spurious excitation of the amplifier resonant circuit. The amplifier, which operates in a flux-pumped mode, is demonstrated with a power gain of more than 20dB over a bandwidth of about 300MHz, where approximate noise measurements indicate quantum-limited pehrformance. A procedure is given for optimizing the bandwidth for this kind of amplifier, using a linearized circuit simulation while minimizing non-linearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scoping study of lower hybrid current drive for CFETR

The paper assesses the applicability of lower hybrid current drive (LHCD) for two potential operating scenarios for the China Fusion Engineering Test Reactor (CFETR): the “hybrid” scenario in which some of the plasma current is sustained by the Ohmic transformer, and the fully non-inductive “steady state” scenario. Here, the πScope workflow engine was used to set up a large number of ray tracing/Fokker-Planck simulations (> 10 4 ) with parametric scans in the antenna poloidal position and launched parallel refractive index (n || ) for both the hybrid and steady state scenarios. Modeling predicts efficient off-axis current drive (1.3 MA for 20 MW launched power) with a peak near ρ of 0.6-0.65 for waves launched from the high field side (HFS). Waves launched from the low field side (LFS) damp at larger radius (ρ > 0.73) with similar efficiency to HFS launch. Stability analysis of the CFETR scenarios favors current drive profiles peaked near the mid-radius, suggesting that HFS launch is preferable due to the current drive location. The effect of wave scattering from density blobs in the edge/scrape-off-layer region was assessed through rotation of the perpendicular wavenumber at the ray origin. Simulations show that this effect can be quite large both in efficiency and damping location, however by adjusting the launched n|| much of the unperturbed performance can be recovered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Performance of a Spiral-Artery, Liquid-Trap-Diode Heat Pipe

A series of parametric investigations are described which determine the effect of various fluid charges on the performance of a 0.635-cm-diam spiral-artery, liquid-trap diode in both the forward and reverse modes. Specific parameters such as forward- and reverse-mode conductances, shutdown times and energies, and recovery to forward-model operation, are evaluated for ethane as a working fluid in the temperature range 170 K to 220 K. Results indicate that the heat pipe will not reliably start up in the forward mode. However, startup can be initiated when preceded by a diode reversal. Also included are data which show the susceptibility of the diode to fluid charge and tilt. The optimum fluid charge was found to be 2.67 g and transport capability at this charge was in excess of 1200 W-cm at 200 K. The diode in the reverse mode exhibited a rapid shutdown (within 9 min) with a shutdown energy of 1150 J (0.32 Wh).

Williams, R. J.↗

Radiation effect on rocket engine performance

Critical problem areas involving the effect of radiation on the combustion of bipropellants are addressed by formulating a universal scaling law in combination with a radiation-enhanced vaporization combustion model. Numerical algorithms are developed and data pertaining to the Variable Thrust Engine (VTE) and the Space Shuttle Main Engine (SSME) are used to conduct parametric sensitivity studies to predict the principal intercoupling effects of radiation. The analysis reveals that low-enthalpy engines, such as the VTE, are vulnerable to a substantial performance setback due to radiative loss, whereas the performance of high-enthalpy engines such as the SSME are hardly affected over a broad range of engine operation. Combustion enhancement by radiative heating of the propellant has a significant impact on propellants with high absorptivity.

Chiu, Huei-Huang↗

Parametric Design Studies on a Direct Liquid Feed Fuel Cell

Parametric design studies were carried out on a direct methanol liquid feed fuel cell employing 1 M MeOH fuel, air and oxygen as oxidant in a 2 inch x 2 inch cell employing polymeric electrolyte membranes. Measurements include voltage-current output parameters, methanol crossover rate, and impedance as a function of several design and operational variables. Design variables are described.

Fuel Cell Advanced Research Projects Agency↗

Degradation of ESR in Polymer Tantalum Capacitors During High Temperature Storage

Replacement of MnO2 cathodes with conductive polymers in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. Due to degradation processes in conductive polymer materials, the existing quality assurance testing that has been developed for MnO2 capacitors is not sufficient to guarantee long-term stability of CPTCs. Insertion of CPTCs in hi-rel systems requires development of models that can predict degradation of the parts at operating conditions. In this work, variations of AC characteristics (capacitance, DF and ESR) in different types of capacitors from three manufacturers have been monitored during storage at temperatures from 100ºC to 175ºC for periods of up to 15,000 hours. Results show that the most sensitive to degradation parameter is ESR. Distributions of times to parametric failure during storage have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of degradation and prediction of times to failure at use temperatures. Mechanisms of degradation and the effect of packaging are discussed.

equivalent series resistance (ESR)↗

Preliminary Study of Burnup Characteristics for a Simplified Small Pebble Bed Reactor

Simplification of the pebble bed reactor by removing the unloading device from the system was peformed. For this reactor design, a suitable fuel-loading scheme is the Peu a Peu (little by little) fueling scheme. In the Peu a Peu modus, there is no unloading device; as such, the fuels are never discharged and remain at the bottom of the core during reactor operation. This means that the burnup cycle and reactivity is controlled by the addition of fuel. The objectives of the the present study were to find a means of carrying out the exact calculations needed to analyze the Peu a Peu fuel-loading scheme and to optimize the fuel composition, and fuel-loading scheme to achieve better burnup characteristics. The Monte Carlo method is used to perform calculations with high accuracy. Before the calculation of the whole core, the analysis for the infinite geometry was performed. The power generated per mass consumed for each combination of the uranium enrichment and packing fraction was analyzed from the parametric survey. By using the optimal value obtained, a whole-core calculation for the small 20 MWth reactor was performed and the criticality and burnup of this design was analyzed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High temperature high velocity direct power extraction using an open-cycle oxy-combustion system

The implementation of oxy-fuel technology in fossil-fuel power plants may contribute to increased system efficiencies and a reduction of pollutant emissions. One technology that has potential to utilize the temperature of undiluted oxy-combustion flames is open-cycle magnetohydrodynamic (MHD) power generators. These systems can be configured as a topping cycle and provide high enthalpy, electrically conductive flows for direct conversion of electricity. This report presents the design and modeling strategies of a MHD combustor operating at temperatures exceeding 3000 K. Throughout the study, computational fluid dynamics (CFD) models were extensively used as a design and optimization tool. A lab-scale 60 kWth model was designed, manufactured and tested as part of this project. A fully-coupled numerical method was developed in ANSYS FLUENT to characterize the heat transfer in the system. This study revealed that nozzle heat transfer may be predicted through a 40% reduction of the semi-empirical Bartz correlation. Experimental results showed good agreement with the numerical evaluation, with the combustor exhibiting a favorable performance when tested during extended time periods. A transient numerical method was employed to analyze fuel injector geometries for the 60-kW combustor. The ANSYS FLUENT study revealed that counter-swirl inlets achieve a uniform pressure and velocity ratio when the ports of the injector length to diameter ratio (L/D) is 4. An angle of 115 degrees was found to increase distribution efficiency. The findings show that this oxy-combustion concept is capable of providing a high-enthalpy environment for seeding, in order to render the flow to be conductive. Based on previous findings, temperatures in the range of 2800-3000 K may enable magnetohydrodynamic power extraction. The heat loss fraction in this oxy-combustion system, based on CFD and analytical calculations, at optimal operating conditions, was estimated to be less than 10 percent. Furthermore, the heat transfer design removed approximately 7 MW/m2. The results observed in the lab-scale system were employed to develop a 1-MW scaled prototype. Scaling methods were based on critical design criteria found in similar systems, aimed at replicating combustion flow fields and reducing possible instabilities. A numerical simulation of the combustor wall was developed for a combined thermal steady model and static structural model. This combined model was developed predict combined stress parameters within the wall during testing conditions. Both models were developed within ANSYS FEA software package. The relative accuracy presented as well major performance parameters are discussed to assess the design's validity and ensure safety. The scaled prototype was manufactured through selective laser melting (SLM)-based additive manufacturing to reduce lead times and increase geometrical complexity. Additional CFD models were developed to optimize coolant manifold system parameters and perform a parametric study on channel geometry. An investigation on coolant manifold geometry demonstrated improvements in channel flow distribution when enlarging manifold lengths and increasing the number of tubes feeding into the flow. A three-dimensional model based on a single channel was developed to capture the effect of variable properties and thermal stratification. All cases in the simulation exhibited higher wall temperatures and lower convective coefficients than those determined through 1-D analytical equations. This implies that pressure and velocity safety factors must be implemented during system operation. Overall, the findings made in this investigation are thought to be of value to researchers and industrial practitioners when designing oxy-fuel direct power extraction systems operating at temperatures exceeding 3000 K. In addition to this, the implementation of the developed technology at pilot and commercial scales could result in a significant improvement in the efficiencies of heritage and next-generation power cycles.

03 NATURAL GAS↗