Effluent sampling of Titan 3 C vehicle exhaust

Downwind in situ ground-level measurements of the exhaust from a Titan 3 C launch vehicle were made during a normal launch. The measurement activity was conducted as part of an overall program to obtain field data for comparison with the multilayer dispersion model currently being used to predict the behavior of rocket vehicle exhaust clouds. All measurements were confined to land, ranging from the launch pad to approximately 2 kilometers downwind from the pad. Measurement systems included detectors for hydrogen chloride (HCl), carbon dioxide (CO2), and particulates (Al2O3). Airborne and ground-based optical systems were employed to monitor exhaust cloud rise, growth, and movement. These measurement systems, located along the ground track (45 deg azimuth from the launch pad) of the exhaust cloud, showed no effluents attributable to the launch. Some hydrogen chloride and aluminum oxide were detected in the surface wind direction (15 deg azimuth) from the pad. Comparisons with the model were made in three areas: (1) assumption of cloud geometry at stabilization; (2) prediction of cloud stabilization altitude; and (3) prediction of the path of cloud travel. In addition, the importance of elemental analyses of the particulate samples is illustrated.

Gregory, G. L.↗

Macroscopic observables experimentally linked to microscopic processes in the explosive fracture and fragmentation of metals

The response of a metal element to explosive loading depends on a broad spectrum of explosive and metal properties, macroscopic geometry plays a crucial role in defining the localized loading history and the resulting gradients of interest, while microscopic effects and defects are generally believed responsible for damage nucleation. Certain experiments reduce the complexity by producing conditions that are uniform in some sense, allowing dynamic measurement of variables that can be correlated with corresponding microscopic effects observed in recovery experiments. Spherical expansion of thin shells, that eventually fragment, and steady wave loading of flat plates are two such experiments. Proton radiography, x-radiography, laser velocimetry, imaging IR, and visible light photography all have produced dynamic measurements in 4340 steel, copper, uranium alloys, tantalum, and titanium. Correlation of the macroscopic measurements with microscopy on recovered samples has been done with a statistical approach.

36 MATERIALS SCIENCE↗

Enhanced reaction rates in NDP analysis with neutron scattering

Neutron depth profiling (NDP) makes accessible quantitative information on a few isotopic concentration profiles ranging from the surface into the sample a few micrometers. Because the candidate analytes for NDP are few, there is little interference encountered. Furthermore, neutrons have no charge so mixed chemical states in the sample are of no direct concern. There are a few nuclides that exhibit large probabilities for neutron scattering. The effect of neutron scattering on NDP measurements has not previously been evaluated as a basis for either enhancing the reaction rates or as a source of measurement error. Hydrogen is a common element exhibiting large neutron scattering probability found in or around sample volumes being analyzed by NDP. A systematic study was conducted to determine the degree of signal change when neutron scattering occurs during analysis. The relative signal perturbation was evaluated for materials of varied neutron scattering probability, concentration, total mass, and geometry. Signal enhancements up to 50% are observed when the hydrogen density is high and in close proximity to the region of analysis with neutron beams of sub thermal energies. Greater signal enhancements for the same neutron number density are reported for thermal neutron beams. Even adhesive tape used to position the sample produces a measureable signal enhancement. Because of the shallow volume, negligible distortion of the NDP measured profile shape is encountered from neutron scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Multiphase lattice Boltzmann simulations for porous media applications

Over the last two decades, lattice Boltzmann methods have become an increasingly popular tool to compute the flow in complex geometries such as porous media. In addition to single phase simulations allowing, for example, a precise quantification of the permeability of a porous sample, a number of extensions to the lattice Boltzmann method are available which allow to study multiphase and multicomponent flows on a pore scale level. In this work, we give an extensive overview on a number of these diffuse interface models and discuss their advantages and disadvantages. Furthermore, we shortly report on multiphase flows containing solid particles, as well as implementation details and optimization issues.

42 ENGINEERING↗

Characterization of faulted dislocation loops and cavities in ion irradiated alloy 800H

Alloy 800H is a high nickel austenitic stainless steel with good high temperature mechanical properties which is considered for use in current and advanced nuclear reactor designs. The irradiation response of 800H was examined by characterizing samples that had been bulk ion irradiated at the Michigan Ion Beam Laboratory with 5 MeV Fe 2+ ions to 1, 10, and 20 dpa at 440 °C. Transmission electron microscopy was used to measure the size and density of both {111} faulted dislocation loops and cavities as functions of depth from the irradiated surface. The faulted loop density increased with dose from 1 dpa up to 10 dpa where it saturated and remained approximately the same until 20 dpa. The faulted loop average diameter decreased between 1 dpa and 10 dpa and again remained approximately constant from 10 dpa to 20 dpa. Cavities were observed after irradiation doses of 10 and 20 dpa, but not after 1 dpa. The average diameter of cavities increased with dose from 10 to 20 dpa, with a corresponding small decrease in density. Cavity denuded zones were observed near the irradiated surface and near the ion implantation peak. To further understand the microstructural evolution of this alloy, FIB lift-out samples from material irradiated in bulk to 1 and 10 dpa were re-irradiated in-situ in their thin-foil geometry with 1 MeV Kr 2+ ions at 440 °C at the Intermediate Voltage Electron Microscope. We observed that the cavities formed during bulk irradiation shrank under thin-foil irradiation in-situ while dislocation loops were observed to grow and incorporate into the dislocation network. The thin-foil geometry used for in-situ irradiation is believed to cause the cavities to shrink.

36 MATERIALS SCIENCE↗

The MIREDO Facility in Novi Sad

The MIREDO (Muon Induced Rare Event Dynamic Observatory) spectrometer system will be mainly devoted for the study of cosmic muon induced nuclear reactions. The system will be developed around the 100% nominal efficiency ultra low-background HPGe spectrometer. Our previous detection system enabled only the detection of secondary muon induced events mostly from the interaction of cosmic muons with the shielding materials. The improved geometry of the MIREDO scintillation detection system will enable the direct measurement of the cross section of the muon induced reactions with the sample material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision measurement of magnetic penetration depth in superconducting films

We report that the magnetic penetration depth (λ) in thin superconducting films is usually measured by the mutual inductance technique. The accuracy of this method has been limited by uncertainties in the geometry of the solenoids and in the film position and thickness, by parasitic coupling between the coils, etc. Here, we present several improvements in the apparatus and the method. To ensure the precise thickness of the superconducting layer, we engineer the films at atomic level using atomic-layer-by-layer molecular beam epitaxy. In this way, we also eliminate secondary-phase precipitates, grain boundaries, and pinholes that are common with other deposition methods and that artificially increase the field transmission and thus the apparent λ. For better reproducibility, the thermal stability of our closed-cycle cryocooler used to control the temperature of the mutual inductance measurement has been significantly improved by inserting a custom-built thermal conductivity damper. Next, to minimize the uncertainties in the geometry, we fused a pair of small yet precisely wound coils into a single sapphire block machined to a high precision. Lastly, the sample is spring-loaded to exactly the same position with respect to the solenoids. Altogether, we can measure the absolute value of λ with the accuracy better than ±1%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant torque differential magnetometry with high frequency quartz oscillators

Sensitive magnetometry has been a powerful probe for investigating quantum materials. Extreme conditions, such as sub-kelvin cryogenic temperatures and ultrahigh magnetic fields, demand further durability for sensitive magnetometry. However, significant mechanical vibrations and rapid magnetic field changes give enormous challenges to conventional magnetometry. Here, this article presents a possible solution to this problem by developing a new magnetometry technique using high-frequency quartz oscillators. The technique takes advantage of the symmetry and geometry of mechanical vibration configurations of standard commercially available MHz quartz oscillators, and the setup keeps the high quality factor resonance with the sample mounted on the oscillator. We further demonstrate the sensitivity of the technique using bismuth single crystals and a Fe 0.25 TaS 2 ferromagnetic material. Quantum oscillations are observed in the magnetometry response below 1 T, and the detected oscillation frequency is shown to come from the electron pockets of the bismuth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DUST DESTRUCTION RATES AND LIFETIMES IN THE MAGELLANIC CLOUDS

The dust budget in galaxies depends on the rate at which dust grains are created in different stellar sources and destroyed by interstellar shocks. Because of their extensive wavelength coverage, proximity, and nearly face-on geometry, the Magellanic Clouds (MCs) provide a unique opportunity to study these processes in great detail. In this paper, we use the complete sample of supernova remnants (SNRs) in the MCs to calculate the lifetimes and destruction efficiencies of silicate and carbon dust. We find dust lifetimes of 22 ± 13 Myr (30 ± 17 Myr) for silicate (carbon) grains in the LMC, and 54 ± 32 Myr (72 ± 43 Myr) for silicate (carbon) grains in the SMC. The corresponding dust destruction rates are 2.3 × 10{sup –2} M {sub ☉} yr{sup –1} (5.9 × 10{sup –3} M {sub ☉} yr{sup –1}) and 3.0 × 10{sup –3} M {sub ☉} yr{sup –1} (5.6 × 10{sup –4} M {sub ☉} yr{sup –1}) for silicate (carbon) grains in the LMC and SMC, respectively. The significantly shorter lifetimes in the MCs, as compared to the Milky Way, are explained as the combined effect of their lower total dust mass and preferentially higher dust-to-gas (D2G) mass ratios in the vicinity of the SNRs. We find that the maximum dust injection rates by asymptotic giant branch stars and core collapse supernovae are an order of magnitude lower than the dust destruction rates by the SNRs, suggesting that most of the dust may be reconstituted in dense molecular clouds. We also discuss the dependence of the dust destruction rate on the local D2G mass ratio, ambient gas density, and metallicity, as well as the application of our results to other galaxies and dust evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

Local atomic structure of thin and ultrathin films via rapid high-energy X-ray total scattering at grazing incidence

Atomic pair distribution function (PDF) analysis is the most powerful technique to study the structure of condensed matter on the length scale from short- to long-range order. Today, the PDF approach is an integral part of research on amorphous, nanocrystalline and disordered materials from bulk to nanoparticle size. Thin films, however, demand specific experimental strategies for enhanced surface sensitivity and sophisticated data treatment to obtain high-quality PDF data. The approach described here is based on the surface high-energy X-ray diffraction technique applying photon energies above 60 keV at grazing incidence. In this way, reliable PDFs were extracted from films of thicknesses down to a few nanometres. Compared with recently published reports on thin-film PDF analysis from both transmission and grazing-incidence geometries, this work brought the minimum detectable film thickness down by about a factor of ten. Depending on the scattering power of the sample, the data acquisition on such ultrathin films can be completed within fractions of a second. Hence, the rapid-acquisition grazing-incidence PDF method is a major advancement in thin-film technology that opens unprecedented possibilities for in situ and operando PDF studies in complex sample environments. By uncovering how the structure of a layered material on a substrate evolves and transforms in terms of local and average ordering, this technique offers new opportunities for understanding processes such as nucleation, growth, morphology evolution, crystallization and the related kinetics on the atomic level and in real time.

36 MATERIALS SCIENCE↗

Establishing a Pure Sample of Side-Piercing Through-Going Cosmic-Ray Muons for LArTPC Calibration in MicroBooNE

Measuring detector properties and performing calibrations of a near-surface Liquid Argon Time Projection Chamber (LArTPC) require large samples of well-reconstructed tracks. Cosmic-ray muon tracks are an ideal calibration source for a surface TPC for these purposes, because they cover the detector volume roughly uniformly and enter the detector volume at a high rate. In order to calibrate the TPC’s position response, the reconstructed track for the 3D trajectory of each cosmic-ray muon must be available. Because of the slow electron drift velocity, reconstructed track information along the drift-coordinate is offset with respect to the true energy deposition location. This offset can be corrected only if the time at which the track enters the detector volume (t 0 ) is also reconstructed. In this note we present a method developed for reconstructing track t 0 for the subset of cosmic-ray tracks which hit either the TPC anode-plane or cathode-plane and are through-going. Over 97% of the t 0 -tagged tracks have their t 0 correctly reconstructed in both simuation in cosmic-ray data while maintaining yield values of 0.9 tracks per 4.8 ms exposure for cathode-piercing tracks and 1.7 tracks per 4.8 ms exposure for anode-piercing tracks in simulation. Coverage maps for an off-beam cosmicray data sample of t 0 -tagged tracks produced with this method show that t 0 -tagged track coverage is as expected given cosmic track geometries in the TPC, acceptance effects, and cut sensitivities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

TACT1, a computer program for the transient thermal analysis of a cooled turbine blade or vane equipped with a coolant insert. 1. Users manual

A computer program to calculate transient and steady state temperatures, pressures, and coolant flows in a cooled, axial flow turbine blade or vane with an impingement insert is described. Coolant side heat transfer coefficients are calculated internally in the program, with the user specifying either impingement or convection heat transfer at each internal flow station. Spent impingement air flows in a chordwise direction and is discharged through the trailing edge and through film cooling holes. The ability of the program to handle film cooling is limited by the internal flow model. Sample problems, with tables of input and output, are included in the report. Input to the program includes a description of the blade geometry, coolant supply conditions, outside thermal boundary conditions, and wheel speed. The blade wall can have two layers of different materials, such as a ceramic thermal barrier coating over a metallic substrate. Program output includes the temperature at each node, the coolant pressures and flow rates, and the inside heat-transfer coefficients.

Gaugler, R. E.↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

Wade, Lawrence A.↗

Growth of detector-grade CZT by Traveling Heater Method (THM): An advancement

In this present work we report the growth of Cd{sub 0.9}Zn{sub 0.1}Te doped with In by a modified THM technique. It has been demonstrated that by controlling the microscopically flat growth interface, the size distribution and concentration can be drastically reduced in the as-grown ingots. This results in as-grown detector-grade CZT by the THM technique. The three-dimensional size distribution and concentrations of Te inclusions/precipitations were studied. The size distributions of the Te precipitations/inclusions were observed to be below the 10-{micro}m range with the total concentration less than 10{sup 5} cm{sup -3}. The relatively low value of Te inclusions/precipitations results in excellent charge transport properties of our as-grown samples. The ({mu}{tau}){sub e} values for different as-grown samples varied between 6-20 x 10{sup -3} cm{sup 2}/V. The as-grown samples also showed fairly good detector response with resolution of {approx}1.5%, 2.7% and about 3.8% at 662 keV for quasi-hemispherical geometry for detector volumes of 0.18 cm{sup 3}, 1 cm{sup 3} and 4.2 cm{sup 3}, respectively.

99 GENERAL AND MISCELLANEOUS↗