Search NASA⌕ Search

SEARCH · Search NASA

Results for “data analysis methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman effect, structural and dielectric properties of sol-gel synthesized polycrystalline GaFe{sub 1-x}Zr{sub x}O{sub 3} (0≤x≤0.15)

Polycrystalline ceramic samples of Zirconium (Zr)-doped GaFeO{sub 3} (GaFe{sub 1-x}Zr{sub x}O{sub 3}) were studied using powder X-ray diffraction, complex impedance spectroscopy and Raman spectroscopic measurements to understand the effect of Zr doping on the structural and dielectric properties. The samples with varying Zr content were prepared by Sol-Gel method. X-ray data analysis confirmed the formation of single phase material without formation of any secondary phases and all are crystallized in Pc2{sub 1}n orthorhombic symmetry. Rietveld refinement of the X-ray data suggested an increase in the lattice constants due to size effect and decreases on x = 0.15 due to the effect of change in interplanner spacing. Impedance studies on the samples showed that the dielectric constant increases while loss tangent decrease as the Zr content increases. Raman scattering on GaFe{sub 1-x}Zr{sub x}O{sub 3} (x = 0, 0.05, 0.10, & 0.15) used to understand the composition dependence on phonon modes at room temperature. On Zr doping, Raman modes frequencies shifts to lower energies consistent with the X-ray data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate [Comparison of implosion core shape observations, 10 ps dilation X-ray imager vs 100 ps gated microchannel plate]

The dilation x-ray imager (DIXI) is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10× improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method to improve the robustness of the DIXI data analysis. Furthermore, we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P 0 , P 2 and P 4 Legendre modes, and their temporal evolution/swings).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

AN OBSERVATIONAL DETERMINATION OF THE PROTON TO ELECTRON MASS RATIO IN THE EARLY UNIVERSE

In an effort to resolve the discrepancy between two measurements of the fundamental constant mu, the proton to electron mass ratio, at early times in the universe we reanalyze the same data used in the earlier studies. Our analysis of the molecular hydrogen absorption lines in archival Very Large Telescope/Ultraviolet and Visible Echelle Spectrometer (UVES) spectra of the damped Lyman alpha systems in the quasi-stellar objects Q0347-383 and Q0405-443 yields a combined measurement of a DELTAmu/mu value of (-7 +- 8) x 10{sup -6}, consistent with no change in the value of mu over a time span of 11.5 Gyr. Here, we define DELTAmu as (mu {sub z} - mu{sub 0}) where mu {sub z} is the value of mu at a redshift of z and mu{sub 0} is the present-day value. Our null result is consistent with the recent measurements of King et al., DELTAmu/mu = (2.6 +- 3.0) x 10{sup -6}, and inconsistent with the positive detection of a change in mu by Reinhold et al. Both of the previous studies and this study are based on the same data but with differing analysis methods. Improvements in the wavelength calibration over the UVES pipeline calibration is a key element in both of the null results. This leads to the conclusion that the fundamental constant mu is unchanged to an accuracy of 10{sup -5} over the last 80% of the age of the universe, well into the matter dominated epoch. This limit provides constraints on models of dark energy that invoke rolling scalar fields and also limits the parameter space of supersymmetric or string theory models of physics. New instruments, both planned and under construction, will provide opportunities to greatly improve the accuracy of these measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding the shift-invariant data: applications for band-excitation scanning probe microscopy *

A shift-invariant variational autoencoder (shift-VAE) is developed as an unsupervised method for the analysis of spectral data in the presence of shifts along the parameter axis, disentangling the physically-relevant shifts from other latent variables. Using synthetic data sets, we show that the shift-VAE latent variables closely match the ground truth parameters. The shift VAE is extended towards the analysis of band-excitation piezoresponse force microscopy data, disentangling the resonance frequency shifts from the peak shape parameters in a model-free unsupervised manner. The extensions of this approach towards denoising of data and model-free dimensionality reduction in imaging and spectroscopic data are further demonstrated. This approach is universal and can also be extended to analysis of x-ray diffraction, photoluminescence, Raman spectra, and other data sets.

36 MATERIALS SCIENCE↗

Uncertainty-quantified phenomenological optical potentials for single-nucleon scattering

Optical-model potentials (OMPs) continue to play a key role in nuclear reaction calculations. However, the uncertainty of phenomenological OMPs in widespread use—inherent to any parametric model trained on data—has not been fully characterized, and its impact on downstream users of OMPs remains unclear. Here we assign well-calibrated uncertainties for two representative global OMPs, those of Koning-Delaroche and Chapel Hill '89, using Markov-chain Monte Carlo for parameter inference. By comparing the canonical versions of these OMPs against the experimental data originally used to constrain them, we show how a lack of outlier rejection and a systematic underestimation of experimental uncertainties contributes to bias of, and overconfidence in, best-fit parameter values. Our updated, uncertainty-quantified versions of these OMPs address these issues and yield complete covariance information for potential parameters. Scattering predictions generated from our ensembles show improved performance both against the original training corpora of experimental data and against a new “test” corpus comprising many of the experimental single-nucleon scattering data collected over the last twenty years. Finally, we apply our uncertainty-quantified OMPs to two case studies of application-relevant cross sections. We conclude that, for many common applications of OMPs, including OMP uncertainty should become standard practice. Furthermore, to facilitate their immediate use, digital versions of our updated OMPs and related tools for forward uncertainty propagation are included as Supplemental Material.

150 ≤ A ≤ 189↗

Search for the decay B s 0 → π 0 π 0 at Belle

We report the results of the first search for the decay B$^{0}_{s}$ → π 0 ⁢π 0 using 121.4 fb -1 of data collected at the Y⁡(5⁢S) resonance with the Belle detector at the KEKB asymmetric-energy e + ⁢e - collider. We observe no signal and set a 90% confidence level upper limit of 7.7 ×10 -6 on the B$^{0}_{s}$ → π 0 π 0 decay branching fraction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Depth of maximum of air-shower profiles at the Pierre Auger Observatory. I. Measurements at energies above $10^{17.8}$ eV

We report a study of the distributions of the depth of maximum, X max , of extensive air-shower profiles with energies above 10 17.8 eV as observed with the fluorescence telescopes of the Pierre Auger Observatory. The analysis method for selecting a data sample with minimal sampling bias is described in detail as well as the experimental cross-checks and systematic uncertainties. Furthermore, we discuss the detector acceptance and the resolution of the X max measurement and provide parametrizations thereof as a function of energy. Finally, the energy dependence of the mean and standard deviation of the X max distributions are compared to air-shower simulations for different nuclear primaries and interpreted in terms of the mean and variance of the logarithmic mass distribution at the top of the atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for the Lepton Flavor Violating Decays B + → K + τ ± ℓ ∓ ( ℓ = e , μ ) at Belle

We present a search for the lepton flavor violating decays B + → K + ⁢$\tau$ ±⁢ ℓ ∓ , with ℓ = (e,μ), using the full data sample of 772×10 6 B$\overline{B}$ pairs recorded by the Belle detector at the KEKB asymmetric-energy e + ⁢e - collider. We use events in which one B meson is fully reconstructed in a hadronic decay mode. We find no evidence for B ± → K ±⁢ $\tau$⁢ℓ decays and set upper limits on their branching fractions at the 90% confidence level in the (1 - 3) × 10 -5 range. The obtained limits are the world’s best results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An innovative acoustic sensor for first in-pile fission gas release determination - REMORA 3 experiment

A fuel rod has been instrumented with a new design of an acoustic resonator used to measure in a non destructive way the internal rod plenum gas mixture composition. This ultrasonic sensor has demonstrated its ability to operate in pile during REMORA 3 irradiation experiment carried out in the OSIRIS Material Testing Reactor (CEA Saclay, France). Due to very severe experimental conditions such as temperature rising up to 150 deg.C and especially, high thermal fluence level up to 3.5 10{sup 19} n.cm{sup 2}, the initial sensor gas speed of sound efficiency measurement was strongly reduced due to the irradiation effects on the piezo-ceramic properties. Nevertheless, by adding a differential signal processing method to the initial data analysis procedure validated before irradiation, the gas resonance peaks were successfully extracted from the output signal. From these data, the molar fractions variations of helium and fission gas were measured from an adapted Virial state equation. Thus, with this sensor, the kinetics of gas release inside fuel rods could be deduced from the in-pile measurements and specific calculations. These data will also give information about nuclear reaction effect on piezo-ceramics sensor under high neutron and gamma flux. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of unfolding methods using RooFitUnfold

In this study we describe RooFitUnfold, an extension of the RooFit statistical software package to treat unfolding problems, and which includes most of the unfolding methods that commonly used in particle physics. The package provides a common interface to these algorithms as well as common uniform methods to evaluate their performance in terms of bias, variance and coverage. In this paper we exploit this common interface of RooFitUnfold to compare the performance of unfolding with the Richardson–Lucy, Iterative Dynamically Stabilized, Tikhonov, Gaussian Process, bin-by-bin and inversion methods on several example problems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing the Sample Selection for Supernova Cosmology

Type Ia supernovae (SNe Ia) are used as distance indicators to infer the cosmological parameters that specify the expansion history of the universe. Parameter inference depends on the criteria by which the analysis SN sample is selected. Only for the simplest selection criteria and population models can the likelihood be calculated analytically, otherwise it needs to be determined numerically, a process that inherently has error. Numerical errors in the likelihood lead to errors in parameter inference. This article presents toy examples where the distance modulus is inferred given a set of SNe at a single redshift. Parameter estimators and their uncertainties are calculated using Monte Carlo techniques. The relationship between the number of Monte Carlo realizations and numerical errors is presented. The procedure can be applied to more realistic models and used to determine the computational and data management requirements of the transient analysis pipeline.

79 ASTRONOMY AND ASTROPHYSICS↗

Visualizing Solution Structure at Solid-Liquid Interfaces using Three-Dimensional Fast Force Mapping

Amongst the challenges for a variety of research fields are the visualization of solid-liquid interfaces and understanding how they are affected by the solution conditions such as ion concentrations, pH, ligands, and trace additives, as well as the underlying crystallography and chemistry. Here, in this context, three-dimensional fast force mapping (3D FFM) has emerged as a promising tool for investigating solution structure at interfaces. This capability is based on atomic force microscopy (AFM) and allows the direct visualization of interfacial regions in three spatial dimensions with sub-nanometer resolution. Here we provide a detailed description of the experimental protocol for acquiring 3D FFM data. The main considerations for optimizing the operating parameters depending on the sample and application are discussed. Moreover, the basic methods for data processing and analysis are discussed, including the transformation of the measured instrument observables into tip-sample force maps that can be linked to the local solution structure. Finally, we shed light on some of the outstanding questions related to 3D FFM data interpretation and how this technique can become a central tool in the repertoire of surface science.

Nakouzi, Elias↗

Characterizing and Improving the Data Reduction Pipeline for the Keck OSIRIS Integral Field Spectrograph

OSIRIS is a near-infrared (1.0–2.4 μm) integral field spectrograph operating behind the adaptive optics system at Keck Observatory and one of the first lenslet-based integral field spectrographs. Since its commissioning in 2005, it has been a productive instrument, producing nearly half the laser guide star adaptive optics papers on Keck. The complexity of its raw data format necessitated a custom data reduction pipeline (DRP) delivered with the instrument in order to iteratively assign flux in overlapping spectra to the proper spatial and spectral locations in a data cube. Other than bug fixes and updates required for hardware upgrades, the bulk of the DRP has not been updated since initial instrument commissioning. We report on the first major comprehensive characterization of the DRP using on-sky and calibration data. We also detail improvements to the DRP, including characterization of the flux assignment algorithm, exploration of spatial rippling in the reduced data cubes, and improvements to several calibration files, including the rectification matrix, bad-pixel mask, and wavelength solution. We present lessons learned from over a decade of OSIRIS data reduction that are relevant to the next generation of integral field spectrograph hardware and data reduction software design.

79 ASTRONOMY AND ASTROPHYSICS↗