Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Simulations of Firn Processes Over the Greenland and Antarctic Ice Sheets: 1980-2021

Conversion of altimetry-derived ice-sheet volume change to mass requires an understanding of the evolution of the combined ice and air content within the firn column. In the absence of suitable techniques to observe the changes to the firn column across the entirety of an ice sheet, the firn column processes are typically modeled. Here, we present new simulations of firn processes over the Greenland and Antarctic ice sheets (GrIS and AIS) using the Community Firn Model and atmospheric reanalysis variables for more than four decades. A data set of more than 250 measured depth–density profiles from both ice sheets provides the basis of the calibration of the dry-snow densification scheme. The resulting scheme results in a reduction in the rate of densification, relative to a commonly used semi-empirical model, through a decreased dependence on the accumulation rate, a proxy for overburden stress. The 1980–2020 modeled firn column runoff, when combined with atmospheric variables from MERRA-2, generates realistic mean integrated surface mass balance values for the Greenland (+390 Gt yr(exp −1)) and Antarctic (+2612 Gt yr(exp −1)) ice sheets when compared to published model-ensemble means. We find that seasonal volume changes associated with firn air content are on average approximately 2.5 times larger than those associated with mass fluxes from surface processes for the AIS and 1.5 times larger for the GrIS; however, when averaged over multiple years, ice and air-volume fluctuations within the firn column are of comparable magnitudes. Between 1996 and 2019, the Greenland Ice Sheet lost nearly 5% of its firn air content, indicating a reduction in the total meltwater retention capability. Nearly all (94 %) of the meltwater produced over the Antarctic Ice Sheet is retained within the firn column through infiltration and refreezing.

Greenland↗

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd [1] and associated criteria (KnGLL > 0.05) can be accurately used to predict zones of breakdown in the flow, and associated errors for surface quantities. Furthermore, when studying reacting flow, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown in minimal (see Fig. 1). Finally, we studied the impact of the grid refinement on the surface quantities in DSMC.

DSMC↗

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd and associated criterion (KnGLL > 0.05) seems conservative in predicting zones of breakdown in the flow, and associated errors for surface quantities. Updated criteria of KnGLL = 2.0 and 0.5 appear to be more appropriate for surface and flow quantities, respectively. Furthermore, when studying reacting flows, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown is minimal.

DSMC↗

In-Depth Mass Spectrometry-Based Single-Cell and Nanoscale Proteomics

Leukemic stem cells are highly dynamic and heterogeneous. Analysis of leukemic stem cells at the single cell level should provide a wealth of insights that would not be possible using bulk measurements. Mass spectrometry (MS)-based proteomic workflows can quantify hundreds or thousands of proteins from a biological sample and has proven invaluable for biomedical research, but samples comprising large numbers of cells are typically required due to limited sensitivity. Recent developments in sample processing, chromatographic separations and MS instrumentation are now extending in-depth proteome profiling to single mammalian cells. We describe specific techniques that increase the sensitivity of single-cell proteomics by orders of magnitude, enabling the promise of single cell proteomics to become a reality. We anticipate such techniques could significantly advance our understanding of leukemic stem cells.

Liang, Yiran↗

Standardizing A Method to Recreate the Density Profile of the Lunar Surface at Depth

As humanity prepares to return to the moon, it becomes ever more important to understand the geotechnical properties of the body we are visiting. However, with only a small number of samples and few missions that took geotechnical measurements, lunar simulants are essential for developing working technologies to use on the lunar surface. Understanding density related properties can allow us to calculate the shear strength and bearing capacity, which is vital for surface trafficability and building permanent structures. However, testbeds do not exist at a depth that would allow us to be able to accurately test certain equipment and loads in these geotechnical conditions. The goal of this project is to be able to recreate the density profile of the lunar surface at depth using piston compaction, and to evaluate success with geotechnical measurements.

C G Locke↗

Aerosol Optical Properties Measured Onboard the Ronald H. Brown During ACE Asia as a Function of Aerosol Chemical Composition and Source Region

During the ACE Asia intensive field campaign conducted in the spring of 2001 aerosol properties were measured onboard the R/V Ronald H. Brown to study the effects of the Asian aerosol on atmospheric chemistry and climate in downwind regions. Aerosol properties measured in the marine boundary layer included chemical composition; number size distribution; and light scattering, hemispheric backscattering, and absorption coefficients. In addition, optical depth and vertical profiles of aerosol 180 deg backscatter were measured. Aerosol within the ACE Asia study region was found to be a complex mixture resulting from marine, pollution, volcanic, and dust sources. Presented here as a function of air mass source region are the mass fractions of the dominant aerosol chemical components, the fraction of the scattering measured at the surface due to each component, mass scattering efficiencies of the individual components, aerosol scattering and absorption coefficients, single scattering albedo, Angstrom exponents, optical depth, and vertical profiles of aerosol extinction. All results except aerosol optical depth and the vertical profiles of aerosol extinction are reported at a relative humidity of 55 +/- 5%. An over-determined data set was collected so that measured and calculated aerosol properties could be compared, internal consistency in the data set could be assessed, and sources of uncertainty could be identified. By taking into account non-sphericity of the dust aerosol, calculated and measured aerosol mass and scattering coefficients agreed within overall experimental uncertainties. Differences between measured and calculated aerosol absorption coefficients were not within reasonable uncertainty limits, however, and may indicate the inability of Mie theory and the assumption of internally mixed homogeneous spheres to predict absorption by the ACE Asia aerosol. Mass scattering efficiencies of non-sea salt sulfate aerosol, sea salt, submicron particulate organic matter, and dust found for the ACE Asia aerosol are comparable to values estimated for ACE 1, Aerosols99, and INDOEX. Unique to the ACE Asia aerosol was the large mass fractions of dust, the dominance of dust in controlling the aerosol optical properties, and the interaction of dust with soot aerosol.

Quinn, P. K.↗

Airborne Lidar Measurements of Aerosol Optical Properties During SAFARI-2000

The Cloud Physics Lidar (CPL) operated onboard the NASA ER-2 high altitude aircraft during the SAFARI-2000 field campaign. The CPL provided high spatial resolution measurements of aerosol optical properties at both 1064 nm and 532 nm. We present here results of planetary boundary layer (PBL) aerosol optical depth analysis and profiles of aerosol extinction. Variation of optical depth and extinction are examined as a function of regional location. The wide-scale aerosol mapping obtained by the CPL is a unique data set that will aid in future studies of aerosol transport. Comparisons between the airborne CPL and ground-based MicroPulse Lidar Network (MPL-Net) sites are shown to have good agreement.

McGill, M. J.↗

SU-D-207-07: Implementation of Full/half Bowtie Filter Model in a Commercial Treatment Planning System for Kilovoltage X-Ray Imaging Dose Estimation

Purpose: To implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) x-ray imaging dose of Varian On-Board Imager (OBI) cone beam CT (CBCT) system. Methods: Full/half bowtie filters of Varian OBI were created as compensator models in Pinnacle TPS (version 9.6) using Matlab software (version 2011a). The profiles of both bowtie filters were acquired from the manufacturer, imported into the Matlab system and hard coded in binary file format. A Pinnacle script was written to import each bowtie filter data into a Pinnacle treatment plan as a compensator. A kV x-ray beam model without including the compensator model was commissioned per each bowtie filter setting based on percent depth dose and lateral profile data acquired from Monte Carlo simulations. To validate the bowtie filter models, a rectangular water phantom was generated in the planning system and an anterior/posterior beam with each bowtie filter was created. Using the Pinnacle script, each bowtie filter compensator was added to the treatment plan. Lateral profile at the depth of 3cm and percent depth dose were measured using an ion chamber and compared with the data extracted from the treatment plans. Results: The kV x-ray beams for both full and half bowtie filter have been modeled in a commercial TPS. The difference of lateral and depth dose profiles between dose calculations and ion chamber measurements were within 6%. Conclusion: Both full/half bowtie filter models provide reasonable results in kV x-ray dose calculations in the water phantom. This study demonstrates the possibility of using a model-based treatment planning system to calculate the kV imaging dose for both full and half bowtie filter modes. Further study is to be performed to evaluate the models in clinical situations.

60 APPLIED LIFE SCIENCES↗

Temperature and electrical conductivity of the lunar interior from magnetic transient measurements in the geomagnetic tail

Magnetometers were deployed at four Apollo sites on the moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments were used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients in the geomagnetic tail field, were analyzed to calculate an electrical conductivity profile for the moon: the conductivity increases rapidly with depth from 10 to the minus 9 power mhos/meter at the lunar surface to .0001 mhos/meter at 200 km depth, then less rapidly to .02 mhos/meter at 1000 km depth. A temperature profile is calculated from conductivity: temperature rises rapidly with depth to 1100 K at 200 km depth, then less rapidly to 1800 K at 1000 km depth. Velocities and thicknesses of the earth's magnetopause and bow shock are estimated from simultaneous magnetometer measurements. Average speeds are determined to be about 50 km/sec for the magnetopause and 70 km/sec for the bow shock, although there are large variations in the measurements for any particular boundary crossing.

Dyal, P.↗

SU-E-T-607: Performance Quantification of the Nine Detectors Used for Dosimetry Measurements in Advanced Radiation Therapy Treatments

Purpose: The purpose of this study was to quantify performance of the nine detectors used for dosimetry measurements in advanced radiation therapy treatments. Methods: The 6 MV beam was utilized for measurements of the field sizes with the lack of lateral charge particle equilibrium. For dose fidelity aspect, energy dependence was studied by measuring PDD and profiles at different depths. The volume effect and its influence on the measured dose profiles have been observed by measuring detector’s response function. Output factor measurements with respect to change in energy spectrum have been performed and collected data has been analyzed. The linearity of the measurements with the dose delivered has been evaluated and relevant comparisons were done. Results: The measured values of the output factors with respect to change in energy spectrum indicated presence of the energy dependence. The detectors with active volume size ≤ 0.3 mm3 maximum deviation from the mean is 5.6% for the field size 0.5 x 0.5 cm2 while detectors with active volume size > 0.3 mm3 have maximum deviation from the mean 7.1%. Linearity with dose at highest dose rate examined for diode detectors showed maximum deviation of 4% while ion chambers showed maximum deviation of 2.2%. Dose profiles showed energy dependence at shallow depths (surface to dmax) influenced by low energy particles with 12 % maximum deviation from the mean for 5 mm2 field size. In relation to Monte Carlo calculation, the detector’s response function σ values were between (0.42±0.25) mm and (1.2±0.25) mm. Conclusion: All the detectors are appropriate for the dosimetry measurements in advanced radiation therapy treatments. The choice of the detectors has to be determined by the application and the scope of the measurements in respect to energy dependence and ability to accurately resolve dose profiles as well as to it’s intrinsic characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Luminescence dosimetry for evaluation of the external exposure in Metlino, upper Techa River valley, Southern Urals, Russia: Analysis of new results

Luminescence dosimetry was applied in the former settlement of Metlino, Southern Urals, Russia as part of a full-scale study to validate the Techa River Dosimetry System (TRDS) 2016 for the upper Techa River region. The village, which was evacuated in 1956, was located 7 km downstream of the release point of liquid radioactive waste by the Mayak plutonium facility. Several brick samples were taken from north-eastern and south-eastern walls of the granary, facing the former Techa river shoreline and floodplain. Samples were all taken at the same height and measured at different depths into the brick. For the majority of brick samples, good Optically Stimulated Luminescence properties of the quartz grains were observed. In some cases, however, strong levels of sensitization and/or signal recuperation were encountered which necessitated adjustment in the measurement protocols. Anthropogenic doses in bricks varied from 1.5 to 6.6 Gy and the horizontal profiles along both walls showed significant variation, which is explained on a qualitative basis. Further, a dose depth profile is observed for selected samples, which is different from the dose depth profile measured and simulated for samples from the north-western wall of the granary in previous studies. This is qualitatively explained by the differences in source configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-162: Characterization of a New Oblong Cone for Use with the Intraoperative Mobetron Unit

Purpose: To evaluate the dosimetric characteristics of a new flat 7 cm x 12 cm oblong cone for intraoperative radiation therapy (IORT) procedures. Methods: Percent depth dose (PDD) curves and profile measurements at dose depths of D100, D90, D80, D50, and D30 were measured using a parallel-plate ion chamber and a 3-D water tank Blue phantom II (iba) for the three energies (6, 9, and 12 MeV) available with the new generation Mobetron 2000. In addition, PDD curves and profiles were made with Gafchromic EBT3 films in solid water phantom. H&D curves were created for each energy for absolute calibration. The films were analyzed using the RIT image analysis software and then compared with the ion chamber results. Output values were obtained by normalizing the dose/MU at D100 at the clinical axis of the oblong cone by the dose/MU at D100 for the flat 10cm cylindrical standard cone using ion chamber measurements. Results: Ion chamber results show that the PDDs from the flat oblong cone, at the clinical axis, match with the PDDs for its “cylindrical brother” 7cm flat cone. These PDDs are comparable with those from the 10cm standard cone. The D100 coincides for all three energies. The cone output factors for the oblong cone are 1.07 for all energies. Ion chamber profiles measurements and film analysis show that the use of flat oblong cone with the 6 and 9 MeV energies Result in horns of approximately 12% and 8%, respectively. Conversely, 12 MeV profiles show loss of flatness near the field edge. Conclusion: The potential advantage of the oblong cones is the elimination of the well-known difficulties of electron field matching, both dosimetrically and in clinical setup.

60 APPLIED LIFE SCIENCES↗

SU-E-T-597: Parameterization of the Photon Beam Dosimetry for a Commercial Linear Accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modelled data, (3) a linear accelerator’s (linac) beam characteristics quality assurance process, and (4) establishing a standard data set for data comparison, etcetera. Parameterization of the photon beam dosimetry creates a portable data set that is easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon percentage depth doses(PDD), profiles, and total scatter output factors(Scp). Methods: Scp, PDDs and profiles for different field sizes (from 2×2 to 40×40cm{sup 2}), depths and energies were measured in a linac using a three-dimensional water tank. All data were smoothed and profile data were also centered, symmetrized and geometrically scaled. The Scp and PDD data were analyzed using exponential functions. For modelling of open and wedge field profiles, each side was divided into three regions described by exponential, sigmoid and Gaussian equations. The model’s equations were chosen based on the physical principles described by these dosimetric quantities. The equations’ parameters were determined using a least square optimization method with the minimal amount of measured data necessary. The model’s accuracy was then evaluated via the calculation of absolute differences and distance–to–agreement analysis in low gradient and high gradient regions, respectively. Results: All differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 mm and 0.5 mm, respectively. Differences in the low gradient regions were 0.20 ± 0.20% and 0.50 ± 0.35% for PDDs and profiles, respectively. For Scp data, all differences were less than 0.5%. Conclusion: This novel analytical model with minimum measurement requirements proved to accurately calculate PDDs, profiles, and Scp for different field sizes, depths and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-281: Monte Carlo Investigation of Sources of Dosimetric Discrepancies with 2D Arrays

Purpose: Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA). Understanding the limitations and use of dosimeters to measure these dose distributions is critical to safe IMRT implementation. In this work, we used Monte Carlo simulations to investigate the possible sources of discrepancy between our measurement with 2D array system and our dose calculation using our treatment planning system (TPS). Material and Methods: MCBEAM and MCSIM Monte Carlo codes were used for treatment head simulation and phantom dose calculation. Accurate modeling of a 6MV beam from Varian trilogy machine was verified by comparing simulated and measured percentage depth doses and profiles. Dose distribution inside the 2D array was calculated using Monte Carlo simulations and our TPS. Then Cross profiles for different field sizes were compared with actual measurements for zero and 90° gantry angle setup. Through the analysis and comparison, we tried to determine the differences and quantify a possible angular calibration factor. Results: Minimum discrepancies was seen in the comparison between the simulated and the measured profiles for the zero gantry angles at all studied field sizes (4×4cm{sup 2}, 10×10cm{sup 2}, 15×15cm{sup 2}, and 20×20cm{sup 2}). Discrepancies between our measurements and calculations increased dramatically for the cross beam profiles at the 90° gantry angle. This could ascribe mainly to the different attenuation caused by the layer of electronics at the base behind the ion chambers in the 2D array. The degree of attenuation will vary depending on the angle of beam incidence. Correction factors were implemented to correct the errors. Conclusion: Monte Carlo modeling of the 2D arrays and the derivation of angular dependence correction factors will allow for improved accuracy of the device for IMRT QA.

60 APPLIED LIFE SCIENCES↗

Testing hadronic-model predictions of depth of maximum of air-shower profiles and ground-particle signals using hybrid data of the Pierre Auger Observatory

We test the predictions of hadronic interaction models regarding the depth of maximum of air-shower profiles, X max , and ground-particle signals in water-Cherenkov detectors at 1000 m from the shower core, S ( 1000 ) , using the data from the fluorescence and surface detectors of the Pierre Auger Observatory. The test consists of fitting the measured two-dimensional ( S ( 1000 ) , X max ) distributions using templates for simulated air showers produced with hadronic interaction models pos-, et--04, 2.3d and leaving the scales of predicted X max and the signals from hadronic component at ground as free-fit parameters. The method relies on the assumption that the mass composition remains the same at all zenith angles, while the longitudinal shower development and attenuation of ground signal depend on the mass composition in a correlated way. The analysis was applied to 2239 events detected by both the fluorescence and surface detectors of the Pierre Auger Observatory with energies between 10 18.5 eV to 10 19.0 eV and zenith angles below 60°. We found, that within the assumptions of the method, the best description of the data is achieved if the predictions of the hadronic interaction models are shifted to deeper X max values and larger hadronic signals at all zenith angles. Given the magnitude of the shifts and the data sample size, the statistical significance of the improvement of data description using the modifications considered in the paper is larger than 5 σ even for any linear combination of experimental systematic uncertainties. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-213-02: Characterization of the Effect of a New Commercial Transmission Detector On Radiotherapy Beams

Purpose: To evaluate the influence of a new commercial transmission detector on radiotherapy beams of various energies. Methods: A transmission detector designed for online treatment monitoring was characterized on a TrueBeam STx linear accelerator with 6MV, 6FFF, 10MV, and 10FFF beams. Measurements of beam characteristics including percentage depth doses (PDDs), inplane and crossplane off-axis profiles at different depths, transmission factors, and skin dose were acquired at field sizes of 3×3cm, 5×5m, 10×10cm, and 20×20cm at 100cm and 80cm source-to-surface distance (SSD). All measurements were taken with and without the transmission detector in the path of the beam. A CC04 chamber was used for all profile and transmission factor measurements. Skin dose was assessed at 100cm, 90cm, and 80cm SSD and using a variety of detectors (Roos and Markus parallel-plate chambers, and OSLD). Results: The PDDs showed small differences between the unperturbed and perturbed beams for both 100cm and 80cm SSD (≤4mm dmax difference and <1.2% average profile difference). The differences were larger for the flattened beams and at larger field sizes. The off-axis profiles showed similar trends. The penumbras looked similar with and without the transmission detector. Comparisons in the central 80% of the profile showed a maximum average (maximum) profile difference between all field sizes of 0.756% (1.535%) and 0.739% (3.682%) for 100cm and 80cm SSD, respectively. The average measured skin dose at 100cm (80cm) SSD for 10×10cm field size was <4% (<35%) dose increase for all energies. For 20×20cm field size, this value increased to <10% (≤45%). Conclusion: The transmission detector has minimal effect on the clinically relevant radiotherapy beams for IMRT and VMAT (field sizes 10×10cm and less). For larger field sizes, some perturbations are observable which would need to be assessed for clinical impact. The authors of this publication has research support from IBA Dosimetry.

60 APPLIED LIFE SCIENCES↗

Corrosion and Mechanical Performance of Grade 92 Ferritic-Martensitic Steel After Exposure to Supercritical Carbon Dioxide

Grade 92 ferritic-martensitic steel is a candidate alloy for medium temperature (< 550 °C) components for the supercritical carbon dioxide (s-CO 2 ) Brayton cycle. 1000 hours exposures were performed on base and welded material in s-CO 2 at temperatures of 450 °C or 550 °C and compared to samples aged in Ar at 550 °C. Both s-CO 2 exposures resulted in a duplex oxide growth and carburization, with 450 °C exhibiting carburization in a power law diffusion profile up to a depth of 200-250 µm, while 550 °C showed a linear profile up to a depth of 100 µm. The different profiles indicate much slower precipitation and coarsening of carbides at the lower temperature, allowing carbon to diffuse deeper into the material. However, 450 °C produced improved mechanical properties while 550 °C produced deteriorated properties. This was due to the higher density of carbon near the metal–oxide interface which leads to significant carbide coarsening and, subsequently, crack initiation and early failure. Finally, additional exposure at 450 °C is predicted to increase deposited carbon, but further study would be needed to understand if and when carburization will produce a negative mechanical effect.

36 MATERIALS SCIENCE↗