Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Integration of Multilevel Superconducting Buried Wiring Layers with Transition-Edge Sensor Detectors for Large Scale Arrays

Lynx, one of the four mission concepts under consideration for the next Astrophysics DecadalReview, will include a microcalorimeter array consisting of more than 100,000 pixels in a compact arrangement with absorber pitch as small as 25 microns. In order to realize the desired array scale, fine-pitch multi-level superconducting wiring with high yield, compatible with rapid expansion of our hydra absorber designs, is essential. We have demonstrated a method of integrating transition edge sensor (TES) microcalorimeters with suitable multilevel buried wiring, fabricated at MIT Lincoln Laboratory using advanced tools dedicated to superconducting circuit fabrication. The TES Mo/Au bilayer is deposited on a high-quality oxide surface created by chemical-mechanical polishing, allowing tight specifications on the TES superconducting transition and link conductivity to be achieved even though the process order has been inverted. The TESs contact the top-level niobium wiring through vias etched through silicon dioxide down to the topmost wiring layer. The article discusses the overall fabrication process, as wellas the behavior of sensors with different via designs, proximity structures, and lateral sizes. An initial iteration of the integrated fabrication process indicates that microcalorimeters fabricated in this way should meet mission specifications using a Mo/Au bilayer with a reasonable critical temperature below 100 mK.

Detector↗

Direct-Write Printed Current Sensor for Load Monitoring Applications

We report on a flexible current sensor development employing direct-write printing and additive manufacturing techniques. The integrated current sensor unit incorporates sensing, data processing & storage, and in-field calibration capabilities. A combination of direct-write printing technique and low-temperature curable metallic ink is used to print Ag wires around a 12.5-μm -thick permalloy film. The overall thickness of the polyimide substrate and permalloy sheet remains well-below 500 μm enabling wrap-around sensor functionality. Fused deposition modeling (FDM) additive manufacturing is used to build custom parts for sensor mounting, encapsulation, and an in-field calibration unit using heat and chemical-resistant thermoplastic which responds well to mechanical stress. In the present configuration, the integrated current sensor unit can be powered through USB or 4 AAA batteries to allow data collection and sensor calibration in the field. The flexible current sensor employing a continuous sheet of the permalloy exhibited a well-behaved signal output response at peak current levels exceeding 15A and in the applied ac frequency range of 60 Hz–10 kHz. Overall, the combination of direct-write printing, thin permalloy material, and additive manufacturing technique shows promise for the development of a reconfigurable low-cost current sensor that can be deployed in large numbers at locations of interest to avail the cost and energy-saving opportunities in industrial/commercial and residential applications.

Yu, Yongchao↗

Real-time Erosion-Corrosion Detection in Waste Transfer Pipelines using Guided Wave Ultrasonic Sensors - 18368

A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the United States Department of Energy Hanford Site Tank Farm to examine structural parameters of the waste transfer systems in order to develop erosion/corrosion rates for relevant system components. The FFS information is acquired from opportunistic evaluations of pipelines that have been removed from service. The objective is to deliver more realistic estimates to the remaining useful life of the components and incorporate those estimates into future design/testing plans across the DOE complex. To aid to this objective, previous efforts at Hanford included the installation of sensors on some of the POR 104 components, to provide real time pipe wall thickness measurements. Due to certain limitations, alternative approaches for remote permanently mounted pipe wall ultrasonic thickness measurement systems have been investigated by FIU. Present research work is a supportive effort by FIU-ARC for DOE and WRPS, which investigates the option for remote-permanently mount guided wave ultrasonic transducer (UT) systems for HLW pipe wall thickness measurements. Specific applications include straight sections, elbows and other fittings used in jumper pits, evaporators, and valve boxes. The proposed method will provide information that will assist engineers with understanding the failure potential of HLW transfer components due to corrosion and erosion. This information can assist in determining if and when lines need to be removed, saving time and resources on the unneeded excavation of transfer lines. This information will also assist engineers with designing new transfer systems by establishing more detailed/accurate guidelines governing the life expectancy of the transfer system and its components. In the previous work, FIU has investigated the use of various ultrasonic systems that are either commercially available or used previously at Hanford and selected the most promising systems for further evaluation. The down-selected system is the guided wave UT sensor system from Permasense which is a UK based manufacturer. It is an integrated wireless sensor network system which used a patented technology for the acoustic wave propagation and has proven applications in the oil and gas industries. Scope of the present research includes the initial verification and validation of the Permasense Guided Wave sensor system as a potential erosion/corrosion detection system for carbon steel pipelines under static conditions. In future, the real-time erosion/corrosion detection will be investigated by measuring the thinning of the pipe sections by circulating simulants and continuous monitoring. This is achieved by passing abrasive and caustic solutions through an in-house designed pipe loop system. Results obtained provide realistic wear rates on 2 inch and 3 inch carbon steel pipes with straight sections and elbows using the Permasense UT sensor system. Thus, the present research delivers solutions for sensor evaluations, conducts bench scale testing followed by data acquisition and analysis for corrosion and erosion assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continuous Calibration Improvement in Solar Reflective Bands: Landsat 5 Through Landsat 8

Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements have been made in the OLI instrument relative to prior Landsat instruments: pushbroom imaging which provides substantially improved Signal-to-Noise Ratio (SNR), spectral bandpasses refinement to avoid atmospheric absorption features, 12 bit data resolution to provide a larger dynamic range that limits the saturation level, a set of well-designed onboard calibrators to monitor the stability of the sensor. Some of these changes such as refinements in spectral bandpasses compared to earlier Landsats and well-designed on-board calibrator have a direct impact on the improved radiometric calibration performance of the instrument from both the stability of the response and the ability to track the changes. The on-board calibrator lamps and diffusers indicate that the instrument drift is generally less than 0.1% per year across the bands. The refined bandpasses of the OLI indicate that temporal uncertainty of better than 0.5% is possible when the instrument is trended over vicarious targets such as Pseudo Invariant Calibration Sites (PICS), a level of precision that was never achieved with the earlier Landsat instruments. The stability measurements indicated by on-board calibrators and PICS agree much better compared to the earlier Landsats, which is very encouraging and bodes well for the future Landsat missions too.

Nischal Mishra↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Evaluation of atmospheric trace constituent sensors operating from remote space and airborne platforms

A laboratory gas analysis system was developed specifically to make trace level measurements of carbon monoxide. To assure that the data collected with this system are correctly aligned with other established methods for making these measurements, an intercalibration study was conducted. The calibration gas was analyzed by the various participating laboratories and found to contain 1.28 ppm CO. Samples were collected at 25 deg, 35 deg, and 45 deg N for profile data to study the variation in concentrations of CO and CH4 as a function of altitude and latitude in continental air over the eastern seaboard of the United States. The experiment was repeated several months later to determine if there were seasonally dependent variations in the CO and CH4 concentrations.

Condon, E.↗

Ground level reflectance measurement techniques - An evaluation with emphasis on the importance of spectral calibration

The bandpasses, overflight conditions, and sensor geometry that will provide optimum target discrimination in remote-sensing studies can be determined only from spectral reflectance measurements made for various sun-target-sensor geometries, supplemented by model calculations which can be checked against field data. The accurate measurement of ground reflectance properties is critical to the design of future sensors and to the determination of imaging conditions. The current investigation has the objective to review typical methods of measuring spectral reflectance, to point out some of the problems inherent to reflectance measuring techniques, and to present a method of checking measurement accuracy.

Duggin, M. J.↗

An occultation satellite system for determining pressure levels in the atmosphere

A two-satellite microwave occultation system is described that will fix, as an absolute function of altitude, the pressure-temperature profile generated by a passive infrared sounder. The 300 mb pressure level is determined to within 24 m rms, assuming the temperture errors produced by the infrared sensor are not greater than 2 K rms. Error caused by water vapor in the radio path is corrected by climatological adjustments. A ground test of the proposed system is described. A microwave signal propagating between two mountain tops was found to be subject to periods of intense fading. Computer analysis of the raypath between the transmitting and receiving stations indicates that multipath and defocusing were responsible for this fading. It is unlikely that an operational pressure-reference-level system will be subject to the deep fades observed in the ground test, because the phenomena are associated with lower altitudes than the closest approach altitude of an occultation-system raypath.

Morrison, A. R.↗

GPM Ground Validation at NASA Wallops Precipitation Research Facility

The Wallops Precipitation Research Facility (WPRF) at NASA Goddard Space Flight Center, Wallops Island, VA has been established as a semi-permanent super-site for the Global Precipitation Measurement (GPM) Ground Validation (GV) program. WPRF is home to research quality precipitation instruments, including NASA’s S-band dual-polarimetric radar (NPOL), and a network of profiling radars, disdrometers, and rain gauges. This study investigates the statistical agreement of the GPM Core Observatory Dual Frequency Precipitation Radar (DPR), combined DPR-GPM Microwave Imager (GMI) and GMI Level II precipitation retrievals compared to WPRF ground observations from a six-year collection of satellite overpasses. Multi-sensor observations are integrated using the System for Integrating Multiplatform Data to Build the Atmospheric Column (SIMBA) software package. SIMBA ensures measurements recorded in a variety of formats are synthesized into a common reference frame for ease in comparison and analysis. Given that instantaneous satellite measurements are observed above ground level, this study investigates the possibility of a time lag between satellite and surface mass-weighted mean diameter (D(sub m)), reflectivity (Z), and precipitation rate (R) observations. Results indicate that time lags vary up to 30 minutes after overpass time but are not consistent between cases. In addition, GPM Core D(sub m) retrievals are within Level I mission science requirements as compared to WPRF ground observations. Results also indicate GPM algorithms overestimate light rain (< 1.0 mm hr(exp -1)). Two very different stratiform rain vertical profiles show differing results when compared to ground reference data. A key finding of this study indicates multi-sensor DPR/GMI combined algorithms outperform single sensor DPR algorithm.

Charanjit S Pabla↗

Universal Sensor and Actuator Requirements

The previous chapters have focused on the requirements for sensors and actuators for "More Intelligent Gas Turbine Engines" from the perspective of performance and operating environment. Even if a technology is available, which meets these performance requirements, there are still various hurdles to be overcome for the technology to transition into a real engine. Such requirements relate to TRL (Technology Readiness Level), durability, reliability, volume, weight, cost, etc. This chapter provides an overview of such universal requirements which any sensor or actuator technology will have to meet before it can be implemented on a product. The objective here is to help educate the researchers or technology developers on the extensive process that the technology has to go through beyond just meeting performance requirements. The hope is that such knowledge will help the technology developers as well as decision makers to prevent wasteful investment in developing solutions to performance requirements, which have no potential to meet the "universal" requirements. These "universal" requirements can be divided into 2 broad areas: 1) Technology value proposition; and 2) Technology maturation. These requirements are briefly discussed in the following.

Taylor Rosenfeld↗

The need for non- or minimally-invasive biomonitoring strategies and the development of pharmacokinetic/pharmacodynamic models for quantification

Advancements in Exposure Science involving the development and deployment of biomarkers of exposure and biological response are anticipated to significantly (and positively) influence health outcomes associated with occupational, environmental and clinical exposure to chemicals/drugs. To achieve this vision, innovative strategies are needed to develop multiplex sensor platforms capable of quantifying individual and mixed exposures (i.e. systemic dose) by measuring biomarkers of dose and biological response in readily obtainable (non-invasive) biofluids. Secondly, the use of saliva (alternative to blood) for biomonitoring coupled with the ability to rapidly analyze multiple samples in real-time offers an innovative opportunity to revolutionize biomonitoring assessments. In this regard, the timing and number of samples taken for biomonitoring will not be limited as is currently the case. In addition, real-time analysis will facilitate identification of work practices or conditions that are contributing to increased exposures and will make possible a more rapid and successful intervention strategy. The initial development and application of computational models for evaluation of saliva/blood analyte concentration at anticipated exposure levels represents an important opportunity to establish the limits of quantification and robustness of multiplex sensor systems by exploiting a unique computational modeling framework. The use of these pharmacokinetic models will also enable prediction of an exposure dose based on the saliva/blood measurement. This novel strategy will result in a more accurate prediction of exposures and, once validated, can be employed to assess dosimetry to a broad range of chemicals in support of biomonitoring and epidemiology studies.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental active and passive dosimetry systems for the NASA Skylab program

Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

Schneider, M. F.↗

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗

Intercomparison of preliminary Earth Radiation Budget Satellite (ERBS) flux estimates and geostationary satellite multi-spectral 'VAS' radiance measurements

Results are reported from a preliminary study to evaluate the level of correlation and, if possible, establish relationships between the spectral radiances sensed by the GOES 6 satellite VISSR Atmospheric Sounder (VAS) and the ERBS longwave sensor. A data set for February 7, 1985 was selected which was scanned with both sensors flying over the region of the Gulf of Mexico. Techniques applied to enhance the equivalence of the data are delineated. Regression equations were applied to assess the levels of correlations for each subsatellite point compared.

Herman, L. D.↗

The development of a high sensitivity neutron displacement damage sensor

Here, the capability to characterize the neutron energy spectrum and fluence received by a test object is crucial to under-standing the damage effects observed in electronic components. For nuclear research reactors and high energy density physics fa-cilities this can pose exceptional challenges, especially with low level neutron fluences. An ASTM test method for characterizing neutron environments utilizes the 2N2222A transistor as a 1-MeV equivalent neutron fluence sensor and is applicable for environ-ments with 1 x 10 12 - 1 x 10 14 1-MeV(Si)-Eqv.-n/cm 2 . In this work we seek to extend the range of this test method to lower fluence environments utilizing the 2N1486 transistor. Here, the 2N1486 is shown to be an effective neutron displacement damage sensor as low as 1 x 10 10 1-MeV(Si)-Eqv.-n/cm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studying phonon coherence with a quantum sensor

Nanomechanical oscillators offer numerous advantages for quantum technologies. Their integration with superconducting qubits shows promise for hardware-efficient quantum error-correction protocols involving superpositions of mechanical coherent states. Limitations of this approach include mechanical decoherence processes, particularly two-level system (TLS) defects, which have been widely studied using classical fields and detectors. In this manuscript, we use a superconducting qubit as a quantum sensor to perform phonon number-resolved measurements on a piezoelectrically coupled phononic crystal cavity. This enables a high-resolution study of mechanical dissipation and dephasing in coherent states of variable size ($\overline{n}$ ≃ 1 – 10 phonons). We observe nonexponential relaxation and state size-dependent reduction of the dephasing rate, which we attribute to TLS. Using a numerical model, we reproduce the dissipation signatures (and to a lesser extent, the dephasing signatures) via emission into a small ensemble (N = 5) of rapidly dephasing TLS. Our findings comprise a detailed examination of TLS-induced phonon decoherence in the quantum regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, development, and testing of a lightweight optical sensor cover system

This paper discusses aspects of the design, development, and testing of the sensor cover on the Clementine (DSPSE) spacecraft. Particular attention is given to defining the typically ambiguous issue of cleanliness. To characterize performance with respect to these requirements, a simple and effective method for testing prototype seals was developed. This testing was useful for comparing various types of seals as well as for providing information about achievable cleanliness levels. The results were invaluable input for defining a realistic final cleanliness requirement that satisfied everyone from mechanisms to sensor engineers. Balancing torque margins (reliability) versus cost and/or weight of the system can be significantly influenced by the choice of seal type. Several seal types are discussed in terms of both cleanliness and ease of implementation. These design issues influence the actuator selection and structural integrity of the door. The cover system designed and fabricated as described above was thoroughly tested both on a component level and on the Clementine system level. Testing included characterization, vibration, pyro-shock, life, and thermal/vacuum. The extensive testing identified problems early enough that they could be resolved prior to integration and launch.

Hurley, Mike↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature: Supporting Data

This dataset was used to assess the potential of a Soil Deformation and Temperature Monitoring System developed and presented in the article named "Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature" and published in Sensors. There are 21 comma-delimited data files (.csv). 14 files contain current measurements performed in a lab setting, enabling the electrical evaluation of the sensor probe. These files are generated by the Keithley DMM6500 multimeter, and list the measured supply current (first column) as a function of time (3rd column). Another set of 6 files is also acquired in lab experiments, but contain soil temperature an deformation measurements, enabling an assessment of the developed device's accuracy. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 5 seconds. Another .csv file contains field data in a similar format (time, temperature, acceleration) collected at the Teller road (mile 27) site near Nome, Alaska with one probe. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗