Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

CalTestBed - Lucent Optics (CRADA Final Report)

The CRADA partner was developing a window film aimed at improving the control of the solar radiation that arrives at a building’s windows, ultimately reducing cooling loads and improving the distribution of daylight. The efforts under this CRADA were aimed at better understanding the performance of one or more prototypes of this film, with the aim of helping to narrow down the film design parameters to values more likely to achieve better performance. The technical means of achieving this project’s goals used LBNL’s world-class test facilities and expertise. These technical means included: (a) measurements of the bidirectional scattering distribution function (BSDF) of film samples, and (b) full-scale measurement of the energy (HVAC, lighting) and comfort (visual, thermal) impacts of at least one film prototype, for two solar angle “seasons” (“high” and “low” solar angle).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Focal Fisheries Requirements for Floating Offshore Wind Co-Design in the Gulf of Maine and the Mid-Atlantic Bight

Floating offshore wind is an emerging renewable energy technology in U.S. waters and globally. Floating offshore wind technology is more complex than fixed-bottom installations, requiring platforms, moorings, and power cables that take up a larger footprint, both in the water column and along the seafloor. This complexity affects opportunities for compatibility between floating offshore wind and other ocean users, particularly fishermen, whose fishing gear also takes up space in the water column and along the seafloor. This report describes the results of semi-structured interviews with key fishing informants from two focal fisheries: (1) Gulf of Maine lobster (fixed gear) and (2) Mid-Atlantic Bight pelagic longline and recreational tuna (mobile gear). A total of six fishermen were interviewed: four from the Gulf of Maine and two from the Mid-Atlantic Bight. The interviews were designed to elicit information and opinions on the co-design of marine space for particular fishing gear and floating offshore wind infrastructure. Here, we provide an overview of participant fishing experience, the spatial requirements of specific gear types, self-reported comfort levels in different fishing scenarios, and concerns about accessing and operating within floating offshore wind arrays. This summary of fishermen s concerns around floating offshore wind infrastructure can guide future co-existence conversations.

17 WIND ENERGY↗

National Energy Education Development Project (NEED Project) (CRADA Final Report)

The U.S. Department of Energy Building Technologies Office (BTO) funds student competitions that introduce students to careers in the building sciences and increase public awareness around high-performance buildings to support the goal of developing, demonstrating, and accelerating the adoption of cost-effective technologies, techniques, tools, and services that enable high-performing, energy-efficient and demand-flexible residential and commercial buildings in both the new and existing buildings markets. The U.S. Department of Energy Solar Decathlon® (DOE/SD) is a flagship, high-visibility international competition started in 2002 that advances the goals of BTO by introducing students to building science careers; educating students and the public about the latest technologies and materials in high-performance buildings; encouraging student-led projects and research centered around building science; and demonstrating to the public the comfort and savings of homes that combine energy-efficient construction, home systems, appliances and innovative design with onsite renewable energy production. SD is a collegiate competition, comprising 10 contests, that challenges student teams to design and build highly efficient and innovative buildings powered by renewable energy. The winners will be those teams that best blend architectural and engineering excellence with innovation, market potential, building efficiency, and smart energy production. Solar Decathlon is comprised of two Challenges – Design Challenge (annual) and Build Challenge (biennial). The National Renewable Energy Laboratory (NREL) provides competition management for Solar Decathlon. NREL and Participant establish this CRADA to enable the success of the overall Solar Decathlon program by managing sponsorship funds and creating a K12 education program. Participant is to act as an Education Partner to Solar Decathlon, which includes: 1) accepting and dispersing sponsorship funds for DOE/SD; and 2) providing K12 education program to support Solar Decathlon Competition Events in April each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitary Thermal Energy Management for Propulsion Range Augmentation (UTEMPRA) (CRADA Final Report)

NREL will work with Delphi to develop technology that integrates the thermal management of electric drive vehicle sub-systems into a unified thermal system that reduces auxiliary loads and increases vehicle range. The ultimate goal is to create a cost-effective system which improves climate control efficiency through heat pump operation and waste heat recovery, while maintaining occupant thermal comfort and meeting powertrain thermal requirements. The technology will also aim to reduce the number of independent cooling systems required in electric drive vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE↗

Virtual Reality for Shoot/No-Shoot Decision Training in Law Enforcement: A Literature Review and Research Agenda

Virtual reality (VR) can materially improve “shoot / no-shoot” (SNS) training by giving officers realistic, repeatable practice making high-stakes decisions under pressure. Traditional tools—live-fire ranges and video simulators—build basics, but they cannot adapt to each officer in real time or fully mirror the complexity of the field. VR closes that gap by creating immersive scenarios that are safer, more flexible, easier to scale across units, and able to capture objective performance data. SNS decisions are not just about marksmanship; they rely on perception, judgment, memory, and the ability to hold fire when a threat is uncertain. Effective training therefore needs realism, decision complexity, and branching outcomes that reflect the true consequences of choices. These elements strengthen recognition of hostile intent while reducing false positives and building the self-control required in ambiguous situations. VR brings specific advantages: dynamic environments, full-body interaction, and the ability to measure performance with precision—enabling targeted feedback and better transfer of learning to the street. At the same time, responsible deployment must address scenario quality (credible environments and behaviors), lawful decision models, and user wellbeing (appropriate stress levels, comfort, and safety). Sandia’s VIPER Lab is positioned to lead this work. The team combines human-performance science, AI/ML, and VR/AR development with a deep equipment bench (e.g., omnidirectional treadmill, eye-tracking, haptics, multiple HMDs). This ecosystem supports building and validating next-generation SNS training that is immersive, measurable, and trustworthy. Bottom line: Investment in VR-enabled SNS training that blends evidence-based design with careful validation and legal safeguards is expected to pay off in safer, more consistent decision-making and improved community trust, delivered through training that is practical to deploy at scale.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolving Issues Regarding Disposal of Safeguarded Nuclear Materials: Concepts for Near Surface and Intermediate Depth Disposal sites

This document presents two case studies on nuclear waste disposal to explore the safeguards challenges and potential solutions present under each scenario. Both involve the disposal of nuclear materials, either for waste containing safeguarded nuclear materials or waste where safeguards on the nuclear materials have been previously terminated. The first case study is that of a low-level waste (LLW) repository that is situated near the surface. This facility will accept safeguarded nuclear materials for disposal. Examples of this type of activity are rare, but the potential for more facilities of this type is very possible as States become more comfortable with considering safeguards measures in perpetuity on deep geological repositories. The second study extends this to the case of terminated wastes at an intermediate depth disposal site. In this case, the reasons why terminated nuclear materials could be found in these disposal facilities and how obligations under the Comprehensive Safeguards Agreement (CSA) and Additional Protocol (AP) are met when the disposed waste items are intermediate level waste (ILW) or high-level waste (HLW).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Laboratory Investigations of Aerosol-Cloud Interactions in an Entraining, Turbulent Environment (Final Technical Report)

The effects that aerosol particles have on clouds in Earth’s atmosphere and the role that clouds play in determining the fate of aerosol particles play a crucial role in determining the human experience on this planet. These interwoven interactions can determine whether it rains or snows, is comfortable, hot or cold, or whether the cloud you gaze at in the sky looks like a tiger or a lump of porridge. How clouds mix with the air surrounding them, a process known as entrainment, further affects these processes. We conducted laboratory experiments of aerosol-cloud interactions in a setting in which we can measure the effects of entrainment – the first laboratory experiments since the pioneering work of Latham and Reed in 1977. We measured the effects of entrainment on aerosol-cloud interactions in the Pi Chamber and also used a state-of-the-art large eddy simulation (LES) to investigate processes in fine detail.

54 ENVIRONMENTAL SCIENCES↗

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Akiachak Energy Efficiency Retrofit Project (Final Technical Report)

The Akiachak Native Community (ANC), a federally recognized Yup'ik Tribe, undertook this energy efficiency initiative to enhance energy performance in key community buildings, including the Tribal IRA Office, Laundry, Police Station, Clinic, and Daycare. Through energy audits and upgrades, the project focused on high-impact improvements like air sealing, LED lighting, and programmable thermostats, primarily in the Tribal Office due to funding constraints. The initiative aims to reduce energy waste, lower heating and electricity costs, and improve facility comfort and longevity. The project aims to generate long-term savings for further improvements by decreasing reliance on imported fuel oil. This initiative aligns with the Tribe's vision for responsible energy use, addressing the challenges of high fuel prices in a remote community, and serves as a model for similar efforts in Akiachak and other Alaska Native villages pursuing energy self-reliance.