Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Out-of-field Dose for Scanned and Scattered Proton Beams

The dose delivered outside of the primary field to non-target tissues is of concern in all types of radiotherapy. For a given radiation type, this dose is dependent upon the delivery technique. Proton beams may be spread laterally to cover the target volume using scattering foils or magnetic scanning. Although scattered beams always use apertures or multi-leaf collimators to limit the radiation to normal tissues, scanning beams may or may not use them. A direct comparison of out-of-field dose for different proton delivery techniques has been thwarted because no institution had, as of April 2008, used multiple delivery techniques and comparisons have had to make extrapolations from measurements or calculations made using different field sizes, ranges, modulations, collimator-to-skin distances, and collimator materials. In this study, the Monte Carlo program MCNPX was used to simulate the dose deposited outside of the primary field for scattered/collimated (STC), scanned/collimated (SNC), and scanned/uncollimated (SNU) beams that have the same field size and penetration depth within a simulated patient. The out-of-field doses ranged from 10{sup -2} to 10{sup -7} of the prescribed dose. The ratio of STC to SNU dose varied from 2 to 420 depending upon the depth and distance off-axis while the SNC to SNU dose varied from 1.2 to 140. As the out-of-field doses are very small for all beam delivery techniques, decisions regarding which technique is appropriate for a given patient or facility should be based upon the magnitude of the out-of-field dose per unit prescribed dose and other issues rather than the ratio of doses for the different beam delivery techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parameters

Purpose: To individually benchmark the incident electron parameters in a Monte Carlo model of an Elekta linear accelerator operating at 6 and 15 MV. The main objective is to establish a simplified but still precise benchmarking procedure that allows accurate dose calculations of advanced treatment techniques. Methods: The EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc are used for photon beam simulations and dose calculations, respectively. A 5 x 5 cm{sup 2} field is used to determine both the incident electron energy and the electron radial intensity. First, the electron energy is adjusted to match the calculated depth dose to the measured one. Second, the electron radial intensity is adjusted to make the calculated dose profile in the penumbrae region match the penumbrae measured by GafChromic EBT film. Finally, the mean angular spread of the incident electron beam is determined by matching calculated and measured cross-field profiles of large fields. The beam parameters are verified for various field sizes and shapes. Results: The penumbrae measurements revealed a non-circular electron radial intensity distribution for the 6 MV beam, while a circular electron radial intensity distribution could best describe the 15 MV beam. These electron radial intensity distributions, given as the standard deviation of a Gaussian distribution, were found to be 0.25 mm (in-plane) and 1.0 mm (cross-plane) for the 6 MV beam and 0.5 mm (both in-plane and cross-plane) for the 15 MV beam. Introducing a small mean angular spread of the incident electron beam has a considerable impact on the lateral dose profiles of large fields. The mean angular spread was found to be 0.7 deg. and 0.5 deg. for the 6 and 15 MV beams, respectively. Conclusions: The incident electron beam parameters in a Monte Carlo model of a linear accelerator could be precisely and independently determined by the benchmarking procedure proposed. As the dose distribution in the penumbra region is insensitive to moderate changes in electron energy and angular spread, accurate penumbra measurements is feasible for benchmarking the electron radial intensity distribution. This parameter is particularly important for accurate dosimetry of mlc-shaped fields and small fields.

43 PARTICLE ACCELERATORS↗

Passive Safety Features Evaluation of KIPT Neutron Source Facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine and its commissioning process is underway. It will be used to conduct basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The facility has an electron accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100 MeV electrons. Tungsten or natural uranium is the target material for generating neutrons driving the subcritical assembly. The subcritical assembly is composed of WWR-M2 - Russian fuel assemblies with U-235 enrichment of 19.7 wt%, surrounded by beryllium reflector assembles and graphite blocks. The subcritical assembly is seated in a water tank, which is a part of the primary cooling loop. During normal operation, the water coolant operates at room temperature and the total facility power is ~300 KW. The passive safety features of the facility are discussed in in this study. Monte Carlo computer code MCNPX was utilized in the analyses with ENDF/B-VII.0 nuclear data libraries. Negative reactivity temperature feedback was consistently observed, which is important for the facility safety performance. Due to the design of WWR-M2 fuel assemblies, slight water temperature increase and the corresponding water density decrease produce large reactivity drop, which offset the reactivity gain by mistakenly loading an additional fuel assembly. The increase of fuel temperature also causes sufficiently large reactivity decrease. This enhances the facility safety performance because fuel temperature increase provides prompt negative reactivity feedback. The reactivity variation due to an empty fuel position filled by water during the fuel loading process is examined. Also, the loading mistakes of removing beryllium reflector assemblies and replacing them with dummy assemblies were analyzed. In all these circumstances, the reactivity change results do not cause any safety concerns.

43 PARTICLE ACCELERATORS↗

Recent progress on the APOLLO3 calculation scheme for the FLUOLE2 experiment

Studies of the neutron fluence on reactor pressure vessel and the correlated reactor lifetime issues require very good knowledge of the neutron source distribution in the reactor core and especially in the peripheral region. The FLUOLE2 experiment offers an appropriate starting configuration to investigate the possibility of using the APOLLO3 deterministic code with a two-step calculation scheme. It enables us to calculate a pin-by-pin neutron source distribution in the core, then to carry out the neutron propagation from the core to neutron detectors. In this paper, we focus on a calculation scheme dedicated to the determination of core neutron source distribution using APOLLO3 with the SHEM281 energy mesh, a Method of Characteristics (MOC) to solve the transport equation for the lattice computation step and a 20-groups 3D computation using the MINARET SN solver of APOLLO3. Reactivity and pin-by-pin reaction rate results have been analyzed. Results obtained with both lattice and core computations show a good agreement with those produced through a reference calculation using the TRIPOLI-4 Monte Carlo transport code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimetry in an IMRT phantom designed for a remote monitoring program

An accurate delivery of prescribed dose is essential to ensure the most successful outcome from advanced radiation treatments such as intensity modulated radiation therapy (IMRT). An anthropomorphic phantom was designed and constructed to conduct a remote-audit program for IMRT treatments. The accuracy of the dosimetry in the phantom was assessed by comparing the results obtained from different detectors with those from Monte Carlo calculations. The developed phantom has a shape of a cylinder with one target and three organs at risk (OARs) inside the unit. The target and OARs were shaped similar to those of nasopharyngeal cancer patients, and manufactured for their identification during computed tomography imaging. The phantom was designed with thermoluminescent dosimeter (TLD) holders that were inserted inside the target and the OARs for the measurements of absolute dose. In addition, the phantom allowed measurements with ionization chambers placed at the TLD locations. As a result, an inter-comparison between the two types of dosimeters was possible. For the measurement of the relative dose distribution across the target and OARs, two film slots were orthogonally placed near the center of the phantom, which also enabled the insertion of inhomogeneities near the target. Measurements with TLDs, provided by Korea Food and Drug Administration and Radiological Physics Center, and measurements with an ionization chamber (IC) were performed in four cases. The first case was one anterior field of 6 MV x rays delivered to the phantom; the second case used the same anterior field, but with inhomogeneities inserted into the phantom. The third case was three fields of 6 MV beams at an equi-gantry angle for the homogeneous phantom, and the fourth case was IMRT delivery to the phantom without inhomogeneities. For each case, measurements with both TLDs and IC were performed. For cases 1-3, theoretical predictions were obtained by using the Monte Carlo (MC) codes (BEAMnrc and DOSXYZnrc6.0). The TLD measurements were larger than the IC readings by 2.2% (1.3-2.5%), 2.2% (1.2-2.9%), and 2.1% (0-3.3%) on average for case 1, case 2 and case 3, respectively. The average deviation between TLDs and MC results was 0.97% (-0.13-2.07%) for the first case, 1.27% (0.34-2.18%) for the second case, and 1.13% (0.31-1.94%) for the third case. The IC reading was less than the MC results; the average deviations were -1.2% (-2.44--0.43%), -0.96% (-1.74--0.54%) and -0.94% (-1.53-0.27%) for the first, second, and third cases, respectively. For the IMRT case, the average deviation between IC readings and TLD measurements was 0.5% (-7.0-3.9%). In conclusion, the TLD measurements in the developed phantom agreed with IC and MC results with less than 3% of an average difference. The developed phantom with TLD dosimeters should be useful for remote monitoring of IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adapting CLUTCH methodology to multigroup TSUNAMI-3D for eigenvalue sensitivity calculations

The sensitivity of the eigenvalue to uncertainties in nuclear data and its evaluation are important for nuclear criticality safety. TSUNAMI-3D sequences within the SCALE code system offer several options to the user community for calculating eigenvalue sensitivity coefficients with multigroup (MG) and continuous energy (CE) 3D transport capabilities. TSUNAMI-3D sequences implement the adjoint-based perturbation theory with MG KENO code, the Contributon Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance CHaracterization (CLUTCH) method with CE KENO code, and the Iterated Fission Probability (IFP) method with CE KENO and Shift codes. Each method has benefits and limitations depending on the problem that is run. The work presented here aims to adapt the CLUTCH method, which enables the Contributon method's mesh-free, memory-efficient approach for calculating adjoint-weighted tallies for sensitivity calculations, to the MG TSUNAMI-3D sequence. This application would eliminate the explicit adjoint KENO calculation, as well as the memory-consuming mesh flux moment tallies required by the conventional MG TSUNAMI-3D. Smaller memory footprints in the CLUTCH methodology and relatively shorter runtimes in MG KENO transport can make MG TSUNAMI-3D a viable method for some complex problems. Moreover, this adaptation allows MG sensitivity calculations with Shift, ORNL's next-generation high-performance Monte Carlo transport code, which currently does not offer any sensitivity capabilities with MG particle transport simulations. Initial implementation of the new MG TSUNAMI-3D sequence and its preliminary results with a selected critical benchmark experiment in the Verified, Archived Library of Inputs and Data (VALID) are presented in this study.

KENO↗

Modeling the flux of high energy negative ions during reactive magnetron sputtering

The negative ion flux during reactive sputtering from planar and rotating cylindrical magnetrons has been studied. Energy resolved mass spectrometry was used to measure the energy and mass distribution of the negative ions. Also the angular distribution of the high energy ions was characterized for planar as well as for rotating cylindrical magnetrons. Besides these measurements, a binary collision Monte Carlo simulation code, SiMTRA, was adapted in order to simulate the energy, mass, and angular distribution of the high energy negative ions. All simulated distributions, for both planar and rotating cylindrical magnetrons, were in excellent correspondence with the experimental observations. Also a model for the amount of high energy negative O{sup -} ions was proposed. Indeed, the logarithm of the amount of high energy negative O{sup -} ions is shown to be related to the secondary electron emission yield of the oxide target, and these two parameters are known to be related to the work function. The SiMTRA simulations, in combination with knowledge of the work function or secondary electron emission yield of the target, allow modeling the flux of high energy negative ions during reactive magnetron sputtering.

36 MATERIALS SCIENCE↗

RETENTION OF STELLAR-MASS BLACK HOLES IN GLOBULAR CLUSTERS

Globular clusters should be born with significant numbers of stellar-mass black holes (BHs). It has been thought for two decades that very few of these BHs could be retained through the cluster lifetime. With masses {approx}10 M{sub Sun }, BHs are {approx}20 times more massive than an average cluster star. They segregate into the cluster core, where they may eventually decouple from the remainder of the cluster. The small-N core then evaporates on a short timescale. This is the so-called Spitzer instability. Here we present the results of a full dynamical simulation of a globular cluster containing many stellar-mass BHs with a realistic mass spectrum. Our Monte Carlo simulation code includes detailed treatments of all relevant stellar evolution and dynamical processes. Our main finding is that old globular clusters could still contain many BHs at present. In our simulation, we find no evidence for the Spitzer instability. Instead, most of the BHs remain well mixed with the rest of the cluster, with only the innermost few tens of BHs segregating significantly. Over the 12 Gyr evolution, fewer than half of the BHs are dynamically ejected through strong binary interactions in the cluster core. The presence of BHs leads to long-term heating of the cluster, ultimately producing a core radius on the high end of the distribution for Milky Way globular clusters (and those of other galaxies). A crude extrapolation from our model suggests that the BH-BH merger rate from globular clusters could be comparable to the rate in the field.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrino signals from solar neutralino annihilations in anomaly mediated supersymmetry breaking model

The lightest neutralino, as the dark matter candidate, can be gravitationally captured by the Sun. In this paper, we studied the high energy neutrino signals from solar neutralino annihilations in the core of the Sun in the anomaly mediated supersymmetry breaking (AMSB) model. Based on the event-by-event Monte Carlo simulation code WimpSim, we studied the detailed energy and angular spectrum of the final muons at large neutrino telescope IceCube. More precisely, we simulated the processes since the production of neutrino via neutralino annihilation in the core of the Sun, neutrino propagation from the Sun to the Earth, as well as the converting processes from neutrino to muon. Our results showed that in the AMSB model it is possible to observe the energetic muons at IceCube, provided that the lightest neutralino has a relatively large Higgsino component, as a rule of thumb N{sub 13}{sup 2}+N{sub 14}{sup 2}>4%, or equivalently, {sigma}{sub SD}>10{sup -5} pb. Especially, for our favorable parameters the signal annual events can reach 102, and the statistical significance can reach more than 20. We pointed out that the energy spectrum of muons may be used to distinguish among the AMSB model and other supersymmetry breaking scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNM neutron detection using a time-gated synthetic aperture hybrid approach

This work focuses on using forward and adjoint transport in a hybrid application of 3-D deterministic (PENTRAN) and Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or 'channels, ' contain a unique set of moderators with 4 atm He-3 detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real time neutron spectroscopy for detecting special nuclear materials in moving vehicles. The initial design, detector response coupling, confirmation of initial design functionality using adjoint transport calculations, and realistic simulation using PENTRAN and MCNP5 are presented. Future work will include optimization and application to realistic scenarios and additional sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-step neutronics calculations with Shift and Griffin for advanced reactor systems

This research develops the initial coupling of the Shift Monte Carlo (MC) code and the Griffin reactor physics code for reactor analysis of non–light-water reactor systems. The novelty of this work is twofold. It is the first application of Shift to produce the multigroup cross sections needed for Griffin as applied to a non–light-water reactor system; and, the first investigation and analysis of characteristics of the Empire microreactor benchmark that should be considered for steady state and transient reactor physics calculations. This application uses the previously developed two-step neutronics analysis workflow to demonstrate this initial coupling. Here, we outline the two-step neutronics analysis workflow in which the Shift MC code is used to generate the multigroup cross sections and fluxes needed by the Griffin deterministic solver. Details on how these multigroup cross sections are generated using MC tallies are given, as well as the practicalities and limitations of the two-step neutronics workflow. The Empire microreactor benchmark was used to investigate and validate this coupling. Results using this benchmark show good agreement between Griffin calculations using Serpent-generated cross sections and Shift-generated cross sections. Analysis of the characteristics of this Empire benchmark show larger eigenvalue differences between heterogeneous and pin–homogenized solutions compared to those of traditional light-water reactor (LWR) designs, thus requiring super homogenization factor corrections for accurate eigenvalue and power distribution predictions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extracted current saturation in negative ion sources

The extraction of negatively charged particles from a negative ion source is one of the crucial issues in the development of the neutral beam injector system for future experimental reactor ITER. Full 3D electrostatic particle-in-cell Monte Carlo collision code - ONIX [S. Mochalskyy et al., Nucl. Fusion 50, 105011 (2010)] - is used to simulate the hydrogen plasma behaviour and the extracted particle features in the vicinity of the plasma grid, both sides of the aperture. It is found that the contribution to the extracted negative ion current of ions born in the volume is small compared with that of ions created at the plasma grid walls. The parametric study with respect to the rate of negative ions released from the walls shows an optimum rate. Beyond this optimum, a double layer builds-up by the negative ion charge density close to the grid aperture surface reducing thus extraction probability, and therefore the extracted current. The effect of the extraction potential and magnetic field magnitudes on the extraction is also discussed. Results are in good agreement with available experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron-Hole Pairs Created by Photons and Intrinsic Properties in Detector Materials

A Monte Carlo (MC) code has been developed to simulate the interaction of gamma-rays with semiconductors and scintillators, and the subsequent energy partitioning of fast electrons. The results provide insights on the processes involved in the electron-hole pair yield and intrinsic variance through simulations of full electron energy cascades. The MC code has been applied to simulate the production of electron-hole pairs and to evaluate intrinsic resolution in a number of semiconductors. In addition, the MC code is also able to consider the spatial distribution of electron-hole pairs induced by photons and electrons in detector materials, and has been employed to obtain details of the spatial distribution of electron-hole pairs in Ge, as a benchmark case. The preliminary results show that the distribution of electron-hole pairs exhibit some important features; (a) the density of electron-hole pairs along the main electron track is very high and (b) most electron-hole pairs produced by interband transitions are distributed at the periphery of the cascade volume. The spatial distribution and density of thermalized electron-hole pairs along the primary and secondary tracks are important for large scale simulations of electron-hole pair transport.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP4-15: Feasibility Study of Tumor Monitoring Technique Using Prompt Gamma Rays During Antiproton Therapy

Purpose: The purpose of this study is to suggest a tumor monitoring technique using prompt gamma rays emitted during the reaction between an antiproton and a boron particle, and to verify the increase of the therapeutic effectiveness of the antiproton boron fusion therapy using Monte Carlo simulation code. Methods: We acquired the percentage depth dose of the antiproton beam from a water phantom with and without three boron uptake regions (region A, B, and C) using F6 tally of MCNPX. The tomographic image was reconstructed using prompt gamma ray events from the reaction between the antiproton and boron during the treatment from 32 projections (reconstruction algorithm: MLEM). For the image reconstruction, we were performed using a 80 × 80 pixel matrix with a pixel size of 5 mm. The energy window was set as a 10 % energy window. Results: The prompt gamma ray peak for imaging was observed at 719 keV in the energy spectrum using the F8 tally fuction (energy deposition tally) of the MCNPX code. The tomographic image shows that the boron uptake regions were successfully identified from the simulation results. In terms of the receiver operating characteristic curve analysis, the area under the curve values were 0.647 (region A), 0.679 (region B), and 0.632 (region C). The SNR values increased as the tumor diameter increased. The CNR indicated the relative signal intensity within different regions. The CNR values also increased as the different of BURs diamter increased. Conclusion: We confirmed the feasibility of tumor monitoring during the antiproton therapy as well as the superior therapeutic effect of the antiproton boron fusion therapy. This result can be beneficial for the development of a more accurate particle therapy.

60 APPLIED LIFE SCIENCES↗

Positron Annihilation Spectroscopy Of High Performance Polymer Films Under CO{sub 2} Pressure

Positron annihilation Lifetime and Doppler broadening measurements are reported for six polymer films as a function of carbon dioxide (CO{sub 2}) absolute pressure ranging from 0 to 45 psi. Since the polymer films were thin and did not absorb all positrons, corrections were made in the lifetime analysis for the absorption of positrons in the positron source and sample holder using the Monte Carlo transport code MCNP. The studied polymers are found to behave differently from each other. Some polymers form positronium and others, such as the polyimide structures, do not. For those polymers that form positronium an interpretation in terms of free volume is possible; for those that don't form positronium, further work is needed to determine how best to describe the behavior in terms of the bulk positron annihilation parameters. A few of the studied polymers exhibit changes in positron lifetime and intensity under CO{sub 2} pressure which may be described by the Henry or Langmuir sorption models, while the positron response of other polymers is rather insensitive to the CO{sub 2} pressure. The results demonstrate the usefulness of positron annihilation spectroscopy in investigating the sorption of CO{sub 2} into various polymers at pressures up to about 3 atm (45psi).

74 ATOMIC AND MOLECULAR PHYSICS↗

SYNCHROTRON EMISSION FROM VERY HIGH ENERGY GAMMA-RAY-INDUCED PAIR CASCADES IN ACTIVE GALACTIC NUCLEUS ENVIRONMENTS

The discovery of very high energy (VHE; E > 100 GeV) {gamma}-ray emission from intermediate- and low-frequency-peaked blazars suggests that {gamma}{gamma} absorption and pair cascading might occur in these objects. In previous papers, we investigated the Compton emission from VHE {gamma}-ray-induced pair cascades, deflected by moderate magnetic fields, in a largely model-independent way, and demonstrated that this emission can explain the Fermi fluxes and spectra of the radio galaxies Cen A and NGC 1275. In this paper, we describe a generalization of our Monte Carlo cascade code to include the angle-dependent synchrotron output from the cascades, allowing for the application to situations with non-negligible magnetic fields, leading to potentially observable synchrotron signatures, but still not dominating the radiative energy loss of cascade particles. We confirm that the synchrotron radiation from the cascades in NGC 1275 and Cen A is negligible for the parameters used in our previous works. We demonstrate that the magnetic field cannot be determined from a fit of the cascade emission to the {gamma}-ray spectrum alone, and the degeneracy can only be lifted if the synchrotron emission from the cascades is observed as well. We illustrate this fact with the example of NGC 1275. We point out that the cascade synchrotron emission may produce spectral features in the same energy range in which the big blue bump is observed in the spectral energy distributions of several blazars, and may make a non-negligible contribution to this feature. We illustrate this idea with the example of 3C 279.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical analysis of the production profile of H{sup 0} atoms and subsequent H{sup -} ions in large negative ion sources

The production and transport processes of H{sup 0} atoms are numerically simulated using a three-dimensional Monte Carlo transport code. The code is applied to the large JAEA 10 ampere negative ion source under the Cs-seeded condition to obtain a spatial distribution of surface-produced H{sup -} ions. In this analysis, the amount of H{sup 0} atoms produced through dissociation processes of H{sub 2} molecules is calculated from the electron temperature and density obtained by Langmuir probe measurements. The high-energy tail of electrons, which greatly affects H{sup 0} atom production, is taken into account by fitting a single-probe characteristic as a two-temperature Maxwellian distribution. In the H{sup 0} atom transport process, the energy relaxation of the H{sup 0} atoms, which affects the surface H{sup -} ion production rate, is taken into account. The result indicates that the surface H{sup -} ion production is enhanced near the high-electron-temperature region where H{sup 0} atom production is localized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗