Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Second Line of Defense Secondary Scrrening Data Collection Spreadsheet

The Second Line of Defense Program is currently examining the effectiveness of secondary screening. As part of that effort, gathering information regarding current secondary-screening practices is necessary. To facilitate the collection of information, we propose using the attached data spreadsheet as a tool to be distributed to the operators responsible for conducting secondary screening (typically officers of the customs authority in a partner country). The intention is to provide the operators with a simple and uniform tool to record and report information that will be useful to the program in evaluating secondary-screening practices. The information collected on the datasheet, as proposed, is a reference number (case number, CAS OS record number, etc.) and date, the reason for the decision to carry out a secondary screening, the instrument(s) used, the length of time data were collected, the outcome (release, tertiary inspection, etc.), and the reachback resource(s) used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stockpile Stewardship and Nuclear Testing: A Technical Assessment

Since 1992, the United States has retained confidence in its nuclear weapon stockpile without performing any tests that produce nuclear yield. Instead, it has invested in a stockpile stewardship program (SSP) based on the same approach that was validated through fifty years of experience during the nuclear testing era. As the test moratorium continues and new information becomes available, it is both necessary and appropriate to periodically revisit the question of whether or not nuclear testing should resume. In a recent article by Dr. Mark Schneider, he asserts that the United States should return to nuclear testing to address the issues that negatively affect our country’s nuclear deterrent. A serious, technically informed evaluation of the most significant of the issues Dr. Schneider has raised is provided in this paper. The conclusion of this evaluation is that the strategy of a well-funded SSP coupled with rigorous assessments to identify if there is a specific need for a nuclear test is sound and cost-effective approach. Any decision otherwise needs to take into careful consideration all the classified SSP successes and data pertaining to the particular issues in question.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Resurgence of a Nation’s Radiation Science Driven by Its Nuclear Industry Needs

This article describes the radiation facilities and associated sample preparation, management, and analysis equipment currently in place at the Dalton Cumbrian Facility, a facility which opened in 2011 to support the UK’s nuclear industry. Examples of measurements performed using these facilities are presented to illustrate their versatility and the breadth of research they make possible. Results are presented from research which furthers our understanding of radiation damage to polymeric materials, radiolytic yield of gaseous products in situations relevant to nuclear materials, radiation chemistry in light water reactor cooling systems, material chemistry relevant to immobilization of nuclear waste, and radiation-induced corrosion of fuel cladding elements. Applications of radiation chemistry relevant to health care are also described. Research concerning the mechanisms of radioprotection by dietary carotenoids is reported. An ongoing open-labware project to develop a suite of modular sample handling components suited to radiation research is described, as is the development of a new neutron source able to provide directional beams of neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

State of practice and emerging application of analytical techniques of nuclear forensic analysis: highlights from the 4th Collaborative Materials Exercise of the Nuclear Forensics International Technical Working Group (ITWG)

Founded in 1996 upon the initiative of the “Group of 8” governments (G8), the Nuclear Forensics International Technical Working Group (ITWG) is an ad hoc organization of official nuclear forensics practitioners (scientists, law enforcement, and regulators) that can be called upon to provide technical assistance to the global community in the event of a seizure of nuclear or radiological materials. The ITWG is supported by and is affiliated with roughly 40 countries and international partner organizations including the International Atomic Energy Agency (IAEA), EURATOM, INTERPOL, EUROPOL, and the United Nations Interregional Crime and Justice Research Institute (UNICRI). Besides providing a network of nuclear forensics laboratories that are able to assist law enforcement during a nuclear smuggling event, the ITWG is also committed to the advancement of the science of nuclear forensic analysis, largely through participation in periodic table top and Collaborative Materials Exercises (CMXs). Exercise scenarios use “real world” samples with realistic forensics investigation time constraints and reporting requirements. These exercises are designed to promote best practices in the field and test, evaluate, and improve new technical capabilities, methods and techniques in order to advance the science of nuclear forensics. The ITWG recently completed its fourth CMX in the 20 year history of the organization. This was also the largest materials exercise to date, with participating laboratories from 16 countries or organizations. Three samples of low enriched uranium were shipped to these laboratories as part of an illicit trafficking scenario, for which each laboratory was asked to conduct nuclear forensic analyses in support of a fictitious criminal investigation. An objective review of the State Of Practice and Art of international nuclear forensic analysis based upon the outcome of this most recent exercise is provided.

ITWG CMX-4↗

A neutron-gamma pulse shape discrimination method based on pure and mixed sources

We present a novel trainable approach to distinguish neutrons from gammas using a particle detector. Traditionally, Pulse Shape Discrimination (PSD) methods for this problem utilize an ad-hoc computation of tail signal energy to perform the detection. Our first contribution is a rigorous analysis of the performance of this existing approach on gold standard Time of Flight (TOF) data. While this approach performs well for high energy pulses, its accuracy drops dramatically as the pulse energy decreases. Our second contribution is a novel data driven classifier that is trained from two readily available sources: one that emits gamma particles (Cs-137), and another that emits a mixture of gamma and neutron particles (Cf-252). We test our approach using TOF experiments and show a marked improvement in accuracy over the traditional method for low false positive rates and low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compatibility Of U 3 Si 2 Fuel With Zr, FeCrAl and SiC/SiC Based Cladding

U 3 Si 2 fuel with FeCrAl or SiC/SiC composite cladding is being considered as an advanced concept and accident tolerant fuel (ATF) system for light water reactors. Understanding their chemical compatibility under operational and accident conditions is fundamental to predicting behavior and fuel qualification. In the present work, experimental determination of interactions and thermodynamic and first principle calculation methods were employed to assess U 3 Si 2 compatibility with novel cladding of FeCrAl-alloys and SiC composites, and were contrasted with compatibility with Zircaloy-4. Diffusion-couple experiments were performed to simulate fuelcladding conditions and the samples were subjected to characterization by scanning electron microscopy and x-ray diffraction. Thermodynamic calculations, based in part on newly determined thermodynamic properties, were used to predict the equilibrium state of the studied systems and to interpret experimental results. First principles calculations using density functional theory were employed to obtain incorporation energies for carbon, iron and uranium in U 3 Si 2 , α- Fe, and SiC structures. Together, the experimental and modeling results have allowed evaluation of the nature of interactions in the fuel-cladding systems.

36 MATERIALS SCIENCE↗

Nuclear Physics Exascale Requirements Review: An Office of Science Review sponsored jointly by Advanced Scientific Computing Research and Nuclear Physics, June 15 - 17, 2016, Gaithersburg, Maryland

Imagine being able to predict — with unprecedented accuracy and precision — the structure of the proton and neutron, and the forces between them, directly from the dynamics of quarks and gluons, and then using this information in calculations of the structure and reactions of atomic nuclei and of the properties of dense neutron stars (NSs). Also imagine discovering new and exotic states of matter, and new laws of nature, by being able to collect more experimental data than we dream possible today, analyzing it in real time to feed back into an experiment, and curating the data with full tracking capabilities and with fully distributed data mining capabilities. Making this vision a reality would improve basic scientific understanding, enabling us to precisely calculate, for example, the spectrum of gravity waves emitted during NS coalescence, and would have important societal applications in nuclear energy research, stockpile stewardship, and other areas. This review presents the components and characteristics of the exascale computing ecosystems necessary to realize this vision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Science in Flux: NASA's Nuclear Program at Plum Brook Station 1955-2005

Science in Flux traces the history of one of the most powerful nuclear test reactors in the United States and the only nuclear facility ever built by NASA. In the late 1950's NASA constructed Plum Brook Station on a vast tract of undeveloped land near Sandusky, Ohio. Once fully operational in 1963, it supported basic research for NASA's nuclear rocket program (NERVA). Plum Brook represents a significant, if largely forgotten, story of nuclear research, political change, and the professional culture of the scientists and engineers who devoted their lives to construct and operate the facility. In 1973, after only a decade of research, the government shut Plum Brook down before many of its experiments could be completed. Even the valiant attempt to redefine the reactor as an environmental analysis tool failed, and the facility went silent. The reactors lay in costly, but quiet standby for nearly a quarter-century before the Nuclear Regulatory Commission decided to decommission the reactors and clean up the site. The history of Plum Brook reveals the perils and potentials of that nuclear technology. As NASA, Congress, and space enthusiasts all begin looking once again at the nuclear option for sending humans to Mars, the echoes of Plum Brook's past will resonate with current policy and space initiatives.

Bowles, Mark D.↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Effects of Packaging SrI2(Eu) Scintillator Crystals

Recent renewed emphasis placed on gamma-ray detectors for national security purposes has motivated 13 researchers to identify and develop new scintillator materials capable of high energy resolution and 14 growable to large sizes. We have discovered that SrI2(Eu) has many desirable properties for gamma-ray 15 detection and spectroscopy, including high light yield of ~90,000 photons/MeV and excellent light yield 16 proportionality. Furthermore, we have demonstrated growth of crack-free 2 diameter boules. We 17 have measured <2.7% FWHM at 662 keV with small detectors (<1 cm3) in direct contact with a 18 photomultiplier tube, and ~3% resolution at 662 keV is obtained for 1 in3 crystals. Due to the 19 hygroscopic nature of SrI2(Eu), proper packaging is required for field use. This work describes a 20 systematic study performed to determine the key factors in the packaging process to optimize 21 performance. These factors include proper polishing of the surface, the geometry of the crystal, 22 reflector materials and windows. A technique based on use of a collimated Cs-137 source was developed 23 to examine light collection uniformity. Employing this technique, we found that when the crystal is 24 packaged properly, the variance in the pulse height at 662 keV from events near the bottom of the 25 crystal compared to those near the top of the crystal could be reduced to <1%. This paper describes the 26 design and engineering of our detector package in order to improve energy resolution of 1 in3-scale 27 SrI2(Eu) crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the first full size ATLAS ITk strip sensor for the endcap region

The ATLAS collaboration is designing the all-silicon Inner Tracker (ITk) that will operate in the HL-LHC replacing the current design. The silicon microstrip sensors for the barrel and the endcap regions in the ITk are fabricated in 6 inch, p-type, float-zone wafers, where large-area strip sensor designs are laid out together with a number of miniature sensors. The radiation tolerance and specific system issues like the need for slim edge of 450 μm have been tested with square shaped sensors intended for the barrel part of the tracker. This work presents the design of the first full size silicon microstrip sensor for the endcap region with a slim edge of 450 μm. The strip endcaps will consist of several wheels with two layers of silicon strip sensors each. The strips have to lie along the azimuthal direction, apart from a small stereo angle rotation (20 mrad on each side, giving 40 mrad total) for measuring the second coordinate of tracks. This stereo angle is built into the strip layout of the sensor and, in order to avoid orphan strips, the sensor edges are inclined by the stereo angle. On top of this, the top and bottom edges are designed as arcs to have equal length strips. Together with the design of this new Stereo Annulus sensor, we will report on the initial measurements of the leakage current as a function of bias voltage, after dicing, and the depletion voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A signal packet router for the upgrade of the Muon spectrometer at the ATLAS experiment

Here, we present the design, characterization, and production of a signal packet router for the upgrade of the ATLAS forward muon detector. The router serves as a packet switch in one of the primary trigger paths. It handles up to 12 serial inputs at 4.8 Gbps/input from on-detector electronics and outputs four 4.8 Gbps to the trigger processing circuits. In the 12-to-4 packet switching process, the input streams are decoded and synchronized to a common clock domain for data packets forwarding and NULL packets suppression. Challenges in the design include operations of multi-giga hertz serial links with low and constant latency (<100 ns) for packet routing, as well as mitigation of radiation-induced effects in the harsh radiation environment over 10 years of detector operation. The Router design has been fully characterized and demonstrated to meet all specifications. In total 256 Routers were installed in the detector. Its design concept can be used in other similar applications, particularly in a radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance improvements of wavelength-shifting-fiber neutron detectors using high-resolution positioning algorithms

On the basis of FluoroBancroft linear-algebraic method [S.B. Andersson, Opt. Exp. 16, 18714 (2008)] three highly-resolved positioning methods were proposed for wavelength-shifting fiber (WLSF) neutron detectors. Using a Gaussian or exponential-decay light-response function (LRF), the non-linear relation of photon-number profiles vs. x-pixels was linearized and neutron positions were determined. The proposed algorithms give an average 0.03-0.08 pixel position error, much smaller than that (0.29 pixel) from a traditional maximum photon algorithm (MPA). The new algorithms result in better detector uniformity, less position misassignment (ghosting), better spatial resolution, and an equivalent or better instrument resolution in powder diffraction than the MPA. Moreover, these characters will facilitate broader applications of WLSF detectors at time-of-flight neutron powder diffraction beamlines, including single-crystal diffraction and texture analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗