Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Reporter-Spin-Assisted T 1 Relaxometry

A single-spin quantum sensor can quantitatively detect and image fluctuating electromagnetic fields via their effect on the sensor spin’s relaxation time, thus revealing important information about the target solid-state or molecular structures. However, the sensitivity and spatial resolution of spin relaxometry are often limited by the distance between the sensor and target. Here, we propose an alternative approach that leverages an auxiliary reporter spin in conjunction with a single-spin sensor, a diamond nitrogen-vacancy (N-V) center. We show that this approach can realize a 100-fold measurement sensitivity improvement for realistic working conditions and we experimentally verify the proposed method using a single shallow N-V center. Our work opens up a broad path of inquiry into a range of possible spin systems that can serve as relaxation sensors without the need for optical initialization and readout capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum nanophotonic interface for tin-vacancy centers in thin-film diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an excellent solid state qubit with optically-addressable transitions and a long electron spin coherence time at elevated (∼1.7 K). However, implementing scalable quantum nodes with high-fidelity optical readout of the electron spin state requires efficient photon emission and collection from the system. Here, in this manuscript, we report a quantum photonic interface for SnV−centers based on one-dimensional photonic crystal cavities fabricated in diamond thin films. Furthermore, we provide a rigorous description of the spontaneous emission dynamics of our system, taking into account individual contributions from both the C and D transitions of the emitter. This allows for determination of Purcell factors per transition and, by extension, the C/D branching ratio SnV− zero phonon line. We observe quality factors up to ~6000 across this sample, and measure up to a 12-fold lifetime reduction, which translates into a Purcell factor of 𝐹 𝐶 =26.2±1.5 for a targeted C transition. By considering the cavity mode polarization alignment with the C and D transition dipole moments, we validate the C/D branching ratio to be 𝜂 BR =0.75±0.01, in line with previous theoretical and experimental findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The LUCID-2 Luminometer

The LUCID-2 detector is the main online and offline luminosity monitor of the ATLAS experiment. It provides 104 different luminosity measurements from different algorithms for each of the thousands of LHC bunches. The new detector is using the quartz windows of 10 mm diameter photomultipliers and optical quartz fibers as the Cherenkov medium. A main challenge for a luminometer is to keep the efficiency constant during years of data-taking. LUCID-2 is using an innovative calibration system based on radioactive Bi-207 sources deposited on the quartz window of the readout photomultipliers.

47 OTHER INSTRUMENTATION↗

Optically selective, acoustically resonant gas detecting transducer

A gas analyzer is disclosed which responds to the resonant absorption or emission spectrum of a specific gas by producing an acoustic resonance in a chamber containing a sample of that gas, and which measures the amount of that emission or absorption by measuring the strength of that acoustic resonance, e.g., the maximum periodic pressure, velocity or density achieved. In the preferred embodiment, a light beam is modulated periodically at the acoustical resonance frequency of a closed chamber which contains an optically dense sample of the gas of interest. Periodic heating of the absorbing gas by the light beam causes a cyclic expansion, movement, and pressure within the gas. An amplitude is reached where the increased losses were the cyclic radiation energy received. A transducing system is inclined for converting the pressure variations of the resonant gas into electronic readout signals.

Dimeff, J.↗

Physics and design of advanced IR bolometers and photoconductors

The state-of-the-art in photoconductors and bolometers is reviewed, centering on the materials development and concepts of extrinsic Si and Ge devices. It is suggested that in the field of 2-D detector arrays the hybrid circuits containing a photoconductor or a photodiode array, bonded with In solder to a switched MOS readout device with up to 60 x 60 elements, will produce superior performance. Other systems discussed include charge-coupled devices, developed for visible-light imaging and adapted to IR imaging, and charge-injection devices, a monolithic combination of a standard photoconductor and a metal-insulator-semiconductor capacitor. Finally, it is pointed out that a nonequilibrium theory of bolometer noise demonstrates the possibility of reducing the traditionally accepted noise limits by 60 percent for Johnson noise and 30 percent for the noise from phonons in the thermal link of the bolometer.

Haller, E. E.↗

Test of IR arrays on the Kuiper Airborne Observatory

NASA's Kuiper Airborne Observatory, which is a C-141 transport aircraft equipped with a 90-cm, all-reflective altazimuth telescope, has been engaged in the Kuiper Infrared Technology Experiment. Attention is presently given to the Experiment's flight series for state-of-the-art two-dimensional, 500-element arrays that use either blocked impurity band or bulk silicon devices. The switched FET readout scheme used on the three arrays flown thus far yields exceptionally low crosstalk. System sensitivities are found to be sufficient for the detection of both pointlike and extended sources; several of each type have been used in staring and scanning experiments.

Russell, R. W.↗

Three-Dimensional Magnetic-Bubble Memory System

Proposed magnetic-bubble memory system includes stack of two-dimensional memory modules. Design enables overall storage density of system to be greater than prior magnetic-bubble memories. Provides nonvolatile storage, with readout access times in millisecond range. Has partly parallel input/output configuration supporting high-performance computing. Also relatively invulnerable to damage by ionizing radiation. Binary data, as represented by direction of magnetization of magnetic bubbles, reads out via Faraday effect.

Katti, Romney R.↗

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Synchronous High-frequency Distributed Readout For Edge Processing At The Fermilab Main Injector And Recycler

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more systematic study of the machine and improved displays of routine operation. However, current projects are demanding more data and at a faster rate from this aging hardware. One such project, Real-time Edge AI for Distributed Systems (READS), requires the high-frequency, low-latency collection of synchronized BLM readings from around the approximately two-mile accelerator complex. Significant work has been done to develop new hardware to monitor the VME backplane and broadcast BLM measurements over Ethernet, while not disrupting the existing operations critical functions of the BLM system. This paper will detail the design, implementation, and testing of this parallel data pathway.

43 PARTICLE ACCELERATORS↗

Dual and Multi-Spectral Band SLS Infrared Camera Systems

Based on the recent success of our strained-layer superlattice (SLS)-based infrared (IR) camera that performed Earth imaging from the International Space Station (ISS) in 2019 we have built, what we consider, to be the next generation multi-band SLS imaging system. The Compact Thermal Imager (CTI) was installed on the Robotic Refueling Mission 3 (RRM3) and attached to the exterior of the ISS. From this location we were able to capture 15 million images of a multitude of fires around the globe in 2019. This unexpected trove of data initiated quite a bit of scientific interest to further utilize this imaging capability but would include features to more precisely monitor terrestrial fires and other surface phenomena. To this end, we developed a technique to install specific bandpass filters directly onto the SLS detector hybrid assembly. Utilizing this technique we have built a CTI-2 camera system with two filters, 4 and 11µm, and have made a second detector assembly with six filter bands from 4-12µm. This second system will also be used to supplement Landsat remote imaging monitoring approximate land surface temperatures, monitor evapotranspiration, sea ice and glacier dynamics. The CTI-2 camera is based on a 1,024x1,024 (1kx1k) format SLS detector hybridized to a FLIR ISC0404 readout integrated circuit (ROIC). The six band SLS focal plane array is based on the 640x512 FLIR ISC 9803 ROIC. This camera system is based on the Landsat 8 and 9 Thermal IR Sensors (TIRS) instrument and one of its purposes is to perform ground truthing for the Landsat 8/9 data at higher spectral resolution. Both Landsat TIRS instruments are dual band thermal IR sensors centered on 11 and 12µm (each with about a 1µm bandpass). Both of our SLS systems utilize a Ricor K548 cryocooler. To streamline costs and development time we used commercial optics and both commercial and custom NASA electronic components. A primary feature of these camera systems is the incorporation of specific filters to collect fire data at ~3.9µm and thermal data at ~11µm. The CTI-2 instrument is designed for 37 m /pixel spatial resolution from 410km orbit (ISS orbit). In this paper, we will present the design and performance of the focal plane, optics, electronics and mechanical structure of the dual‑band CTI-2 and the focal plane performance of the six‑band focal plane.

Murzy Jhabvala↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

WE-AB-BRB-08: Progress Towards a 2D OSL Dosimetry System Using Al2O3:C Films

Purpose: To develop a 2D dosimetry system based on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C films for medical applications. Methods: A 2D laser scanning OSL reader was built for readout of newly developed Al2O3:C films (Landauer Inc.). An image reconstruction algorithm was developed to correct for inherent effects introduced by reader design and detector properties. The system was tested using irradiations with photon and carbon ion beams. A calibration was obtained using a 6 MV photon beam from clinical accelerator and the dose measurement precision was tested using a range of doses and different dose distributions (flat field and wedge field). The dynamic range and performance of the system in the presence of large dose gradients was also tested using 430 MeV/u {sup 12}C single and multiple pencil beams. All irradiations were performed with Gafchromic EBT3 film for comparison. Results: Preliminary results demonstrate a near-linear OSL dose response to photon fields and the ability to measure dose in dose distributions such as flat field and wedge field. Tests using {sup 12}C pencil beam demonstrate ability to measure doses over four orders of magnitude. The dose profiles measured by the OSL film generally agreed well with that measured by the EBT3 film. The OSL image signal-to-noise ratio obtained in the current conditions require further improvement. On the other hand, EBT3 films had large uncertainties in the low dose region due to film-to-film or intra-film variation in the background. Conclusion: A 2D OSL dosimetry system was developed and initial tests have demonstrated a wide dynamic range as well as good agreement between the delivered and measured doses. The low background, wide dynamic range and wide range of linearity in dose response observed for the Al{sub 2}O{sub 3}:C OSL film can be beneficial for dosimetry in radiation therapy applications, especially for small field dosimetry. This work has been funded by Landauer Inc. Dr. Eduardo G. Yukihara also would like to thank the Alexander von Humboldt Foundation for his support at the DKFZ.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-05: Preliminary Results On a 2D Dosimetry System Based On the Optically Stimulated Luminescence of Al2O3

Purpose: To develop a precise 2D dose mapping technique based on the optically stimulated luminescence (OSL) from Al{sub 2}O{sub 3} films for medical applications. Methods: A 2D laser scanning reader was developed using fast F{sup +}-center (lifetime of <7 ns) and slow F-center (lifetime of 35 ms) OSL emission from newly developed Al{sub 2}O{sub 3} films (Landauer Inc.). An algorithm was developed to correct images for both material and system properties. Since greater contribution of the F??-center emission in the recorded signal increases the readout efficiency and robustness of image corrections, Al{sub 2}O{sub 3}:C,Mg film samples are being investigated in addition to Al{sub 2}O{sub 3}:C samples. Preliminary investigations include exposure of the films to a 6 MV photon beam at 10 cm depth in solid water phantom with an SSD of 100 cm, using a 10 cm × 10 cm flat field or a 4 cm × 4 cm field with a 60° wedge filter. Kodak EDR2 radiographic film and EBT2 Gafchromic film were also exposed for comparison. Results: The results indicate that the algorithm is able to correct images and calculate 2D dose. For the wedge field irradiation, the calculated dose at the center of the field was 0.9 Gy for Al{sub 2}O{sub 3}:C and 0.87 Gy for Al{sub 2}O{sub 3}:C,Mg, whereas, the delivered dose was 0.95 Gy. A good qualitative agreement of the dose profiles was obtained between the OSL films and EDR2 and EBT2 films. Laboratory tests using a beta source suggest that a large dynamic range (10{sup −2}−10{sup 2} Gy) can be achieved using this technique. Conclusion: A 2D dosimetry system and an in-house image correction algorithm were developed for 2D film dosimetry in medical applications. The system is in the preliminary stage of development, but the data demonstrates the feasibility of this approach. This work was supported by Landauer, Inc.

36 MATERIALS SCIENCE↗

Earth System Digital Twins (ESDT) Technology for NASA Earth Science

For NASA's Advanced Information Systems Technology (AIST) Program, an Earth System Digital Twin (ESDT) is defined as an interactive and integrated multidomain, multiscale, digital replica of the state and temporal evolution of Earth systems. It dynamically integrates: relevant Earth system models and simulations; other relevant models (e.g., related to the world's infrastructure); continuous and timely (including near real time and direct readout) observations (e.g., space, air, ground, over/underwater, Internet of Things (IoT), socioeconomic); long-time records; as well as analytics and artificial intelligence tools. Effective ESDTs enable users to run hypothetical scenarios to improve the understanding, prediction of and mitigation/response to Earth system processes, natural phenomena and human activities as well as their many interactions. An ESDT is a type of integrated information system that, for example, enables continuous assessment of impact from naturally occurring and/or human activities on physical and natural environments. AIST ESDT strategic goals are to: 1. Develop information system frameworks to provide continuous and accurate representations of systems as they change over time; 2. Mirror various Earth Science systems and utilize the combination of Data Analytics, Artificial Intelligence, Digital Thread, and state-of-the-art models to help predict the Earth’s response to various phenomena; 3. Provide the tools to conduct "what if" investigations that can result in actionable predictions. The AIST ESDT thrust is developing capabilities toward the development of future digital twins of the Earth or of subcomponents of the Earth. This will enable the development of an overarching framework that will integrate New Observing Strategies (NOS) to enable new observation measurements, i.e., multi-source, coordinated, dynamic and responsive to needs and requests defined by Analytic Collaborative Frameworks (ACF) that enable agile science investigations fusing and analyzing very large amounts of diverse data. NOS and ACF capabilities along with open access to various science, infrastructure and human data, interconnected modeling, data assimilation, simulations, surrogate modeling, high-performance computing and advanced visualization, will define a powerful framework that could be utilized for local, regional or global and/or thematic digital twins. This presentation will describe a general overview of the AIST ESDT vision including prior work done in the areas of NOS and ACF as well as current and upcoming ESDT projects.

Jacqueline Le Moigne↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Tailoring a low-molecular weight protein tyrosine phosphatase into an efficient reporting protein

Fusion reporter methods are important tools for biology and biotechnology. An ideal reporter protein in a fusion system should have little effects on its fusion partner and provide an easy and accurate readout. Therefore, a small monomeric protein with high activity for detection assays often has advantages as a reporter protein. For this purpose, we have tailored the human B-form low-molecular-weight phosphotyrosyl phosphatase (HPTP-B) to increase its general applicability as a potent reporter protein. With the aim to eliminate interference from cysteine residues in the native HPTP-B, combined with a systematic survey of N- and C-terminal truncated variants, a series of cysteine to serine mutations were introduced, which allowed isolation of an engineered soluble protein with suitable biophysical properties. When we deleted both the first six residues and the last two residues, we still obtained a soluble mutant protein with correct folding and similar activity with wild-type protein. This mutant with two cysteine to serine mutations, HPTP-B{sup N{sub {Delta}}6-C{sub {Delta}}2-C90S-C109S}, has good potential as an optimal reporter.

60 APPLIED LIFE SCIENCES↗

Telecom-Luminescent and Room Temperature Coherent Tetrathiafulvalene-Based Qubits in Spin-Rich Solids

One of the main challenges facing quantum information science (QIS) is the development of robust qubits that can be op-erated under ambient conditions. Current state-of-the-art anionic nitrogen vacancy center (NV–) defect qubits are robust enough to be operated at room temperature but lack scalability and tunability. These are areas where molecular qubits excel, although they typically suffer from poor air stability and fast decoherence at elevated temperatures and in magneti-cally noisy environments. Organic-based systems offer advantages to this end, although examples retaining room tem-perature coherence are still rare. Furthermore, most organic-based systems lack optical transitions similar to NV– centers that could allow for optical initialization and readout. Here we report two new organic-based qubit candidates that demonstrate room temperature coherence in nuclear and electron spin-rich environments. These qubits luminesce far into the near-infrared (NIR, 700-1700 nm) and telecom (~1260-1625 nm) regions, ideal for biological sensing and com-munications applications, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗