Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Consistency-Enhanced Evolution for Variable Selection Can Identify Key Chemical Information from Spectroscopic Data

In the last few decades, spectroscopic techniques such as near-infrared (NIR) spectroscopy have gained wide applications in several industries, such as the pharmaceutical, agricultural, oil, and gas industries. As a result, various soft sensors have been developed to predict sample properties from spectroscopic readings. Because the spectroscopic readings at different wavelengths, especially at the adjacent wavelengths, are highly correlated, it has been shown that variable selection could significantly improve a soft sensor’s prediction performance while reducing the model complexity. To improve the prediction performance, most variable selection methods focus on identifying the variables (i.e., wavelengths or wavelength segments) that are strongly correlated with the dependent variable. Although many successful applications have been reported, these variable selection methods do have their limitations. Specifically, the selected wavelengths sometimes show little connection to the chemical bounds or functional groups presenting in the sample. In addition, the selected variables can be quite sensitive to the choice of the training samples. In this work, we address these limitations from a different perspective: if a variable selection algorithm can identify the truly relevant input variables, it should consistently identify the same subset of variables regardless of the choice of the training samples. Therefore, we propose a variable selection method that aims to improve the consistency of variable selection resulting from different training samples. Furthermore, the new algorithm is termed consistency-enhanced evolution for variable selection (CEEVS). To demonstrate the performance and robustness of CEEVS, we compare the proposed method with three representative variable selection methods using five published NIR data sets. These case studies clearly demonstrate that by improving the variable selection consistency, we can not only achieve improved prediction performance, but also identify key chemical information from spectroscopic data.

42 ENGINEERING↗

Image Guided Planning for Prostate Carcinomas With Incorporation of Anti-3-[18F]FACBC (Fluciclovine) Positron Emission Tomography: Workflow and Initial Findings From a Randomized Trial

Purpose: {sup 18}F-Fluciclovine (anti-1-amino-3-[{sup 18}F]fluorocyclobutane-1-carboxylic acid) is a novel positron emission tomography (PET)/computed tomography (CT) radiotracer that has demonstrated utility for detection of prostate cancer. Our goal is to report the initial results from a randomized controlled trial of the integration of {sup 18}F-fluciclovine PET-CT into treatment planning for defining prostate bed and lymph node target volumes. Methods and Materials: We report our initial findings from a cohort of 41 patients, of the first enrolled on a randomized controlled trial, who were randomized to the {sup 18}F-fluciclovine arm. All patients underwent {sup 18}F-fluciclovine PET-CT for the detection of metabolic abnormalities and high-resolution CT for treatment planning. The 2 datasets were registered first by use of a rigid registration. If soft tissue displacement was observable, the rigid registration was improved with a deformable registration. Each {sup 18}F-fluciclovine abnormality was segmented as a percentage of the maximum standard uptake value (SUV) within a small region of interest around the lesion. The percentage best describing the SUV falloff was integrated in planning by expanding standard target volumes with the PET abnormality. Results: In 21 of 55 abnormalities, a deformable registration was needed to map the {sup 18}F-fluciclovine activity into the simulation CT. The most selected percentage was 50% of maximum SUV, although values ranging from 15% to 70% were used for specific patients, illustrating the need for a per-patient selection of a threshold SUV value. The inclusion of {sup 18}F-fluciclovine changed the planning volumes for 46 abnormalities (83%) of the total 55, with 28 (51%) located in the lymph nodes, 11 (20%) in the prostate bed, 10 (18%) in the prostate, and 6 (11%) in the seminal vesicles. Only 9 PET abnormalities were fully contained in the standard target volumes based on the CT-based segmentations and did not necessitate expansion. Conclusions: The use of {sup 18}F-fluciclovine in postprostatectomy radiation therapy planning was feasible and led to augmentation of the target volumes in the majority (30 of 41) of the patients studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precursor Analysis Report: Remote Access Attack on Oldsmar Water Treatment Facility 2021

The Remote Access Attack on Oldsmar Water Treatment Facility 2021 Precursor Analysis Report leverages publicly available information about the Oldsmar cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 5 February 2021, an adversary gained unauthorized remote access to Bruce T. Haddock Water Treatment Plant in Oldsmar, Florida, which provides treated water to 15,000 customers. The adversary accessed the facility’s Supervisory Control and Data Acquisition (SCADA) workstation and human machine interface (HMI) to change the chemical concentration of sodium hydroxide, commonly referred to as lye and used to regulate acidity levels, from 100 parts per million (PPM) to 11,100 PPM. The chemical was raised to lethal levels that if ingested could lead to serious soft tissue damage, burns, or even death. The facility, however, had redundancies and alarms in place to alert personnel of dangerous chemical levels, and facility officials stated it would have taken 24 to 36 hours for the chemical changes to affect the water supply. Researchers and analysts identified six unique techniques utilized during the attack with a total of 23 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Four of the identified techniques used during the Oldsmar cyber attack were precursors to the triggering event. Analysis identified 21 observables associated with these precursor techniques, 20 of which were assessed to have an increased likelihood of being perceived in the minutes preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

Covalency of M–N Bonds in Isomorphous Lanthanide and Actinide 5-(2-Pyridyl)-1H-tetrazolate Complexes

Experimental and computational analyses of [M(pdtz) 3 (H 2 O) 3 ]·3.5H 2 O (M 3+ = Pu 3+ −Cm 3+ , La 3+ −Nd 3+ , and Sm 3+ −Ho 3+ , pdtz− = 5-(2-pyridyl)-1H-tetrazolate) were conducted to understand potential differences in bonding between lanthanide and actinide complexes with a N-donor ligand. Structural analyses show that the An−N bond distances in the Pu 3+ , Am 3+ , and Cm 3+ complexes are within error of one another. Whereas in the lanthanide series, there is a nearly linear decrease in the Ln−N bond lengths from La 3+ to Ho 3+ (excluding Pm 3+ ). The An−N bond lengths are ∼0.015 Å shorter than their similarly-sized lanthanide analogs, in agreement with computational results that suggest greater covalent character in these bonds versus those with lanthanides. QTAIM analysis indicates that the An−N orbital mixing remains essentially unchanged from Pu 3+ to Cm 3+ , consistent with the nearly identical An−N bond lengths. However, upon deconvolution of the NLMOs into orbital compositions, the metal orbital contributions to An−N bonding decreases slightly overall wherein the 6d involvement remains constant, 7s involvement slightly increases, and 5f participation decreases. The molecular orbital energy diagram indicates that energy degeneracy between the 5f metal and 2p ligand orbitals increases from Pu 3+ to Cm 3+ and counteracts the contraction of the 5f orbtials. Together with prior reports of decreasing energy degeneracy between 5f and 3p orbitals from Np 3+ to Cf 3+ , these observations provide guidance on understanding how chemical bonding evolves in the actinide series.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

14 Steps to Creating Value in Cost and Schedule Resources for Nuclear Waste Management - 20188

While Waste Management budgets are shrinking, DOE required cost and schedule controls are becoming increasingly stringent. At the same time, there is a scarcity of adept, qualified, and competent projects controls staff who both understand nuclear waste management and are capable of addressing today's cost and schedule challenges. In response, we have developed a systematic approach to training and mentoring project controls staff. The approach is based on the observations and lessons learned on projects, both successful and unsuccessful, over the past 20 years. During that time, we evaluated staff development and used that experience to design a program that progresses the maturity, knowledge and experience of the individual. The program is based on the unique needs of cost and schedule specialists while incorporating the best leadership and managerial applications. The system is not limited to developing individual software skills, which is a primary focus of many project controls training programs. Instead, our system develops an individual's soft and hard skill sets. The system develops the user's skill, talent, attitude, and drive to do the best job possible. It focuses on all aspects of becoming a more productive technical team while accepting responsibility for individual growth. It also enhances the project controls team by setting up checks and balances that everyone is aware of and participates in. The system is based on 14 steps of increasing complexity in knowledge and application. The system clarifies roles, responsibilities and expectations. It helps eliminate uncertainty and reduces stress on staff and managers. It contains everyday routine actions and is simple to implement. It allows the development of a consistent rhythm to staff growth and development. Mastering the steps will allow the user to achieve excellence in cost and schedule control. The 14 steps are: 1 - Key Performance Objectives, 2 - Check Lists, 3 - Desktop Guides, 4 - System Description, 5 - Procedures, 6 - Software and On the Job Training (OTJ), 7 - Traceability Checks, 8 - Surveillances, 9 - 32 Criteria, 10 - The Contract, 11 - Customer/Government Guidance, 12 - Training and Mentoring Others, 13 - Master your weekly and daily schedules, 14 - Improving your interpersonal skills. Application and mastery of this system will produce better cost and schedule control results. Your project controls staff will write better reports, analyze data better, make better use of their time, and be more valuable to decision makers. If followed rigorously, our system will produce a great project controls team, which is invaluable to the success of each project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

TAS: 89 0227: TAS Recovery Act - Optimization and Control of Electric Power Systems: ARRA

The name SuperOPF is used to refer several projects, problem formulations and soft-ware tools intended to extend, improve and re-define some of the standard methods of optimizing electric power systems. Our work included applying primal-dual interior point methods to standard AC optimal power flow problems of large size, as well as extensions of this problem to include co-optimization of multiple scenarios. The original SuperOPF problem formulation was based on co-optimizing a base scenario along with multiple post-contingency scenarios, where all AC power flow models and constraints are enforced for each, to find optimal energy contracts, endogenously determined locational reserves and appropriate nodal energy prices for a single period optimal power flow problem with uncertainty. This led to example non-linear programming problems on the order of 1 million constraints and half a million variables. The second generation SuperOPF formulation extends this by adding multiple periods and multiple base scenarios per period. It also incorporates additional variables and constraints to model load following reserves, ramping costs, and storage resources. A third generation of the multi-period SuperOPF, adds both integer variables and a receding horizon framework in which the problem type is more challenging (mixed integer), the size is even larger, and it must be solved more frequently, pushing the limits of currently available algorithms and solvers. The consideration of transient stability constraints in optimal power flow (OPF) problems has become increasingly important in modern power systems. Transient stability constrained OPF (TSCOPF) is a nonlinear optimization problem subject to a set of algebraic and differential equations. Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability in OPF. To handle the dynamics in TSCOPF, the set of differential equations can be approximated or converted into equivalent algebraic equations before they are included in an OPF formulation. In Chapter 4, a rigorous evaluation of using a predefined and fixed threshold for rotor angles as a mean to determine transient stability of the system is developed. TSCOPF can be modeled as a large-scale nonlinear programming problem including the constraints of differential-algebraic equations (DAE). Solving a TSCOPF problem can be challenging due to (i) the differential-equation constraints in an optimization problem, (ii) the lack of a true analytical expression for transient stability constraint in OPF. Unfortunately, even the current best TSCOPF solvers still suffer from the curse of dimensionality and unacceptable computational time, especially for large-scale power systems with multiple contingencies. In chapter 5, thse issues will be addressed and a new method to incorporate the transient stability constraints will be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of macroscopic surface defects on dynamic damage: An experimental and numerical study

This study examines the impact of macroscopic surface defects on the dynamic ductile damage behavior of polycrystalline metals using plate-impact experiments. Defects of various shapes (flat, round, and point) were manufactured on the free or impact surfaces of annealed copper specimens. The experiments were diagnosed with photon Doppler velocimetry measurements and soft recovery techniques. The experimental results revealed that defect shape and location significantly affect velocity–time profiles and void distribution. In order to understand the dynamics of shock propagation and corresponding ductile damage evolution within the target specimens, the impact experiments were modeled with a calibrated Tepla model, a dynamic ductile damage model for polycrystalline metals [Nguyen et al., Int. J. Solids Struct. 329, 113833 (2026)]. Overall, our resulting simulated velocity showed good agreement with measured velocity, and our simulated porosity distributions qualitatively matched experimental data. Based on our simulation results, defects on the free surface were found to distort rarefaction waves and therefore the corresponding spall planes. On the other hand, defects on the impact surface generated a delayed shock when the flyer plate and the defected target area were in contact, leading to distortion of the spall plane. The distortion of the spall plane resulted in a non-uniform distribution of voids within the defected specimens. Lastly, we examined the role of local work hardening due to the defect manufacturing process on the velocity and porosity distribution, using Tepla simulations with a simplified representation of local hardening. This investigation highlights the importance of defect geometry, location, and local hardening associated with defect generation in dynamic ductile damage processes.

36 MATERIALS SCIENCE↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

Mechanical and Structural Behavior of Granular Material Packed Beds for Space Life Support System Applications

Long-term human mission to space, such as living in International Space Station (ISS), Lunar, and Martian bases, and travel to Mars, must m ake use of Advanced Life Support Systems (ALSS) to generate and recycle critical life supporting elements like oxygen and water. Oxygen Gen eration Assembly (OGA) and Water Processor Assembly (WPA), critical c omponents of ALSS, make use of series of granular material packed beds for generation and recycling of oxygen and water. Several granular m aterials can be used for generation, recycling, processing and recovery of oxygen and water. For example, they may include soft bed media, e.g. ion exchange resins for oxygen generation assembly and hard bed media such as, activated alumina, magchem (Magnesium oxide) and activa ted carbon to remove organic species like ethanol, methanol, and urea from wastewater in Water recovery/processing assembly. These beds are generally packed using a plate-spring mechanism to provide sufficien t compaction to the bed media throughout the course of operation. This paper presents results from an experimental study of a full-scale, 3 8.1 cm (15 inches) long and 3.7 cm (1.44 inches) diameter. activated alumina bed enclosed in a cylinder determining its force-displacement behavior, friction mobilizing force, and axial normal stress distribu tion under various axially applied loads and at different levels of packing. It is observed that force-displacement behavior is non-linear for low compaction level and becomes linear with increase in compaction of the bed media. Axial normal stress distribution along the length of the bed media decreased non-linearly with increase in depth from the loading end of the granular media. This paper also presents experimental results on the amount of particulates generated corresponding to various compaction levels. Particulates generated from each of the tests were measured using standard US sieves. It was found that the p articulates and the overall displacement of the bed media increased with decrease in initial compaction of the bed media. This effect could be attributed to the greater tendency for inter-particle sliding/rub bing due to smaller internal friction angles, as seen from the shear tests, at lesser initial compacted levels. Upon unloading, it was obse rved that there was no change in displacement (especially rebounding) in the bed media. This effect could be attributed to the fact that th e porous activated alumina particles fracture/break upon increase in applied load (during loading phase) and occupy void spaces in between the material grains; thereby leading to settling of the media. The lo ad-displacement curve becomes more linear with increase in initial compaction of the bed media. It is concluded that compaction considerabl y affects the load-displacement behavior of the bed media. A series of tests were also conducted on the packed bed media to determine the f orce required to mobilize the friction between the bed media and the housing cylinder. The results from these tests showed the existence of significant friction between the bed media and the encasing stainles s steel cylinder. Further, it was found that friction effects were more pronounced for media with higher initial compaction. Internal frict ion of the granular media was measured using direct shear apparatus. It was observed that the internal friction increased with increase in initial compaction of the bed media. In this study, a computational m odel (CM) is also developed using finite element software ANSYS to verify experimental results obtained for the distribution of the axial n ormal stress and axial displacement along the length of the full-scal e activated alumina bed media. In the computational model, the granular material is considered to have appropriate failure and frictional c ontact exists between the wall and the granular media. It is observed that the model predicts results closely with the experimental method. The compational results show that the axial normal stress distribution along the length of the activated alumina media decreases non-linea rly from the loading end and is negligible beyond a certain depth. Th is can be attributed to the existence of friction between the walls and the media and that the friction takes up most of the applied load.

Malla, Ramesh B.↗

SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH). The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the contouring uncertainty on V100 and D90 fortunately, has a conservative effect of underestimating the prostate coverage.

60 APPLIED LIFE SCIENCES↗

Preoperative Pazopanib in High-Risk Soft Tissue Sarcoma: Phase II Window-of Opportunity Study of the German Interdisciplinary Sarcoma Group (NOPASS/GISG-04)

Background: Preoperative devascularization might improve local control and thus the outcome of patients with soft tissue sarcoma (STS). The multikinase inhibitor pazopanib has antiangiogenic effects and is approved for treating metastatic STS. We conducted a trial of preoperative pazopanib therapy in high-risk STS. Methods: This single-arm, phase II trial included patients with resectable, non-metastatic, treatment-naïve, high-risk STS. Patients received pazopanib 800 mg daily while waiting for surgery (21-day ‘window of opportunity’). The primary endpoint was metabolic response rate (MRR; proportion of patients with ≥ 50% reduction of mean standardized uptake value [SUV{sub mean}] in post- vs. pretreatment fluorodeoxyglucose–positron emission tomography/computed tomography [FDG-PET-CT]). Planned sample size was 35 patients (type I error, 5%; type II error, 20%). A translational substudy explored associations between response and concentration of circulating angiogenic factors. Results: Futility analysis was performed after 21 patients (11 female, mean age 67 years; liposarcoma n = 15); 17/21 patients were evaluable for the primary endpoint. The MRR was 1/17 (5.9%, 95% confidence interval < 0.01–0.29). Mean change in SUV{sub mean} of post- versus pretreatment PET was a 6% decrease (range 65% decrease to 34% increase); 7/21 (33.3%) patients had 12 grade 3/4 toxicities, and 19/21 (95.2%) patients were resected (all R0). One (4.8%) patient suffered a grade 4 postoperative complication (anastomotic leakage). Circulating endothelial progenitor cells, soluble vascular endothelial growth factor, and angiopoietin-2 concentrations showed no relevant changes during treatment. Conclusions: Although this study showed that preoperative pazopanib is not effective for unselected high-risk STS patients, relevant treatment effects were observed in a single patient. Future research needs to better define subgroups potentially benefiting from preoperative pazopanib treatment. ClinicalTrials.gov identifier: NCT01543802.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-06: Kernel Based Dosimetry for 90Y Microsphere Liver Therapy Using 90Y Bremsstrahlung SPECT/CT

Purpose: 90Y microsphere therapy in liver presents a situation where beta transport is dominant and the tissue is relatively homogenous. We compare voxel-based absorbed doses from a 90Y kernel to Monte Carlo (MC) using quantitative 90Y bremsstrahlung SPECT/CT as source distribution. Methods: Liver, normal liver, and tumors were delineated by an interventional radiologist using contrast-enhanced CT registered with 90Y SPECT/CT scans for 14 therapies. Right lung was segmented via region growing. The kernel was generated with 1.04 g/cc soft tissue for 4.8 mm voxel matching the SPECT. MC simulation materials included air, lung, soft tissue, and bone with varying densities. We report percent difference between kernel and MC (%Δ(K,MC)) for mean absorbed dose, D70, and V20Gy in total liver, normal liver, tumors, and right lung. We also report %Δ(K,MC) for heterogeneity metrics: coefficient of variation (COV) and D10/D90. The impact of spatial resolution (0, 10, 20 mm FWHM) and lung shunt fraction (LSF) (1,5,10,20%) on the accuracy of MC and kernel doses near the liver-lung interface was modeled in 1D. We report the distance from the interface where errors become <10% of unblurred MC as d10(side of interface, dose calculation, FWHM blurring, LSF). Results: The %Δ(K,MC) for mean, D70, and V20Gy in tumor and liver was <7% while right lung differences varied from 60–90%. The %Δ(K,MC) for COV was <4.8% for tumor and liver and <54% for the right lung. The %Δ(K,MC) for D10/D90 was <5% for 22/23 tumors. d10(liver,MC,10,1–20) awere <9mm and d10(liver,MC,20,1–20) awere <15mm; both agreed within 3mm to the kernel. d10(lung,MC,10,20), d10(lung,MC,10,1), d10(lung,MC,20,20), and d10(lung,MC,20,1) awere 6, 25, 15, and 34mm, respectively. Kernel calculations on blurred distributions in lung had errors > 10%. Conclusions: Liver and tumor voxel doses with 90Y kernel and MC agree within 7%. Large differences exist between the two methods in right lung. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-07: Evaluation of a Grid-Based Boltzmann Solver for Nuclear Medicine Voxel-Based Dose Calculations

Purpose: Grid-based Boltzmann solvers (GBBS) have been successfully implemented in radiation oncology clinics as dose calculations for e×ternal photon beams and 192Ir sealed-source brachytherapy. We report on the evaluation of a GBBS for nuclear medicine vo×el-based absorbed doses. Methods: Vo×el-S-values were calculated for monoenergetic betas and photons (1, 0.1, 0.01 MeV), 90Y, and 131I for 3 mm vo×el sizes using Monte Carlo (DOS×YZnrc) and GBBS (Attila 8.1-beta5, Transpire). The source distribution was uniform throughout a single vo×el. The material was an infinite 1.04 g/cc soft tissue slab. To e×plore convergence properties of the GBBS 3 tetrahedral meshes, 3 energy group structures, 3 different square Chebyschev-Legendre quadrature set orders (Sn), and 4×2013;7 spherical harmonic e×pansion terms (Pn) were investigated for a total of 168 discretizations per source. The mesh, energy group, and quadrature sets are 8×, 3×, and 16×, respectively, finer than the corresponding coarse discretization. GBBS cross sections were generated with full electronphoton-coupling using the vendors e×tended CEP×S code. For accuracy, percent differences (%Δ) in source vo×el absorbed doses between MC and GBBS are reported for the coarsest and finest discretization. For convergence, ratios of the two finest discretization solutions are reported along each variable. Results: For 1 MeV, 0.1 MeV, 0.01 MeV, Y90, and I-131 beta sources the %Δ in the source vo×el for (coarsest,finest) discretization were (+2.0,−6.4), (−8.0, −7.5), (−13.8, −13.4), (+0.9,−5.5), and (− 10.1,−9.0) respectively. The corresponding %Δ for photons were (+33.7,−7.1), (−9.4, −9.8), (−17.4, −15.2), and (−1.7,−7.7), respectively. For betas, the convergence ratio of mesh, energy, Sn, and Pn ranged from 0.991–1.000. For gammas, the convergence ratio of mesh, Sn, and Pn ranged from 0.998–1.003 while the ratio for energy ranged from 0.964–1.001. Conclusions: GBBS is promising for nuclear medicine vo×el-based dose calculations. Ongoing work includes evaluating GBBS in bone, lung, and realistic clinical PET/SPECT-based activity distributions. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

07 ISOTOPE AND RADIATION SOURCES↗

MO-G-BRF-02: Enhancement of Texture-Based Metastasis Prediction Models Via the Optimization of PET/MRI Acquisition Protocols

Purpose: We have previously identified a prediction model of lung metastases at diagnosis of soft-tissue sarcomas (STS) that is composed of two textural features extracted from FDG-PET and T1-weighted (T1w) MRI scans. The goal of this study is to evaluate whether the optimization in FDGPET and MRI acquisition parameters would enhance the prediction performance of texture-based models. Methods: Ten FDG-PET and T1w- MRI digitized tumor models were generated from imaging data of STS patients who underwent pre-treatment clinical scans between 2005 and 2011. Five of ten patients eventually developed lung metastases. Numerically simulated MR images were produced using echo times (TE) of 2 and 4 times the nominal clinical parameter (TEc), and repetition times (TR) of 0.5, 0.67, 1.5 and 2 times the nominal clinical parameter (TRc) found in the DICOM headers (TEc range: 9–13 ms, TRc range: 410-667 ms). PET 2D images were simulated using Monte-Carlo and were reconstructed using an ordered-subsets expectation maximization (OSEM) algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. For all possible combinations of PET and MRI acquisition parameters, the prediction model was constructed using logistic regression with new coefficients, and its associated prediction performance for lung metastases was evaluated using the area under the ROC curve (AUC). Results: The prediction performance over all simulations yielded AUCs ranging from 0.7 to 1. Notably, TR values below or equal to TRc and higher PET post-reconstruction filter widths yielded higher prediction performance. The best results were obtained with a combination of 4*TEc, TRc, 30 OSEM iterations and 2mm filter width. Conclusion: This work indicates that texture-based metastasis prediction models could be improved using optimized choices of FDG-PET and MRI acquisition protocols. This principle could be generalized to other texture-based models.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗