Minimizing Error Potential Using Computer Applications - 18498

Many Savannah River Site (SRS) liquid waste facility operations depend upon repetitive engineering calculations and operator actions. Although these calculations and actions are formalized in technical reports and paper procedures, they can still be vulnerable to data entry errors, calculation errors, equipment alignment errors, and occasional changes caused by different people performing these activities. Savannah River Remediation (SRR) is using computer automation to reduce these error precursors by standardizing repetitive calculations and by performing plant alignment checks for repetitive operation processes. Data entry can be automated, calculation methodologies can be standardized, and computers can check to see that predefined plant conditions exist before equipment operation. In addition to improving quality, the time required for these activities to generate technical reports, to perform independent reviews, and to perform equipment alignment checks can be significantly reduced. In the case of operator-performed calculations, error precursors involve distractions that can occur over a multi-page paper procedure, confusing displays and controls from equipment, mathematical errors, complacency, and unfamiliarity with the procedure among many others. Repetitive engineering calculations suffer from similar error precursors and are often compounded by high workloads, lack of proficiency, lack of standard methodology, mental shortcuts, and biases. Web-based computer applications can eliminate many of these precursors through standardization. Calculation methods are fixed, inputs are fixed, and computer checks can highlight potentially wrong inputs and outputs. Automated calculations are performed almost instantaneously once input is provided. Operators and engineers can spend more time focusing on the results than on the process to achieve the results. Similarly, when operators use repetitive procedures involving equipment manipulation, the same error precursors apply. Automated operation sequences and equipment checks can be programmed into the distributed control system to provide standard operating processes that reduce and eliminate error precursors. This paper describes how SRR incorporates Human Performance Improvement (HPI) principles when automating calculations and operation processes. Computer applications will be reviewed in detail, highlighting the software development life-cycle that includes requirements gathering, prototyping, design, development, testing, and implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spontaneous Cyclogenesis without Radiative and Surface-Flux Feedbacks

Tropical cyclones (TCs) are among the most intense and feared storms in the world. What physical processes lead to cyclogenesis remains the most mysterious aspect of TC physics. Here, we study spontaneous TC genesis in rotating radiative–convective equilibrium using cloud-resolving simulations over an f plane with constant sea surface temperature. Previous studies proposed that spontaneous TC genesis requires either radiative or surface-flux feedbacks. To test this hypothesis, we perform mechanism-denial experiments, in which we switch off both feedback processes in numerical simulations. We find that TCs can self-emerge even without radiative and surface-flux feedbacks. Although these feedbacks accelerate the genesis and impact the size of the TCs, TCs in the experiments without them can reach similar intensities as those in the control experiment. We show that TC genesis is associated with an increase in the available potential energy (APE) and that convective heating dominates the APE production. Overall, our result suggests that spontaneous TC genesis may result from a cooperative interaction between convection and circulation and that radiative and surface-flux feedbacks accelerate the process. Furthermore, we find that increasing the planetary rotation favors spontaneous TC genesis.

54 ENVIRONMENTAL SCIENCES↗

A mechanical reduced order model for elastomeric 3D printed architectures

Direct ink writing of silicone elastomers enables printing with precise control of porosity and mechanical properties of ordered cellular solids, suitable for shock absorption and stress mitigation applications. With the ability to manipulate structure and feedstock stiffness, the design space becomes challenging to parse to obtain a solution producing a desired mechanical response. We derive an analytical design approach for a specific architecture. Results from finite element simulations and quasi-static mechanical tests of two different parallel strand architectures were analyzed to understand the structure-property relationships under uniaxial compression. Combining effective stiffness-density scaling with least squares optimization of the stress responses yielded general response curves parameterized by resin modulus and strand spacing. An analytical expression of these curves serves as a reduced order model, which, when optimized, provides a rapid design capability for filament-based 3D printed structures. Finally, as a demonstration, the optimal design of a face-centered tetragonal architecture is computed that satisfies prescribed minimum and maximum load constraints.

36 MATERIALS SCIENCE↗

Circuit QED Pulse Control Interface

The Circuit Quantum Electrodynamics (Circuit QED) Pulse Control Interface provides a robust platform for designing and testing control signals in transmon-cavity systems. Utilizing a PyQt5-based drag-and-drop GUI, this tool facilitates the implementation of two key protocols: Selective Number-dependent Arbitrary Phase (SNAP)-Displacement and Echoed Conditional Displacement (ECD). It offers real-time pulse visualization and supports CSV exports and imports for integrating custom signals, thereby enhancing circuit QED experimental workflows. Simulations performed using QuTiP confirm the high fidelity of quantum state preparations and the effectiveness of the implemented controls. Future developments will focus on interfacing the tool with hardware and enhancing signal generation accuracy.

Lin, Yuqing↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Reinforcement Learning-MPC Approach for Distribution System Critical Load Restoration

This paper proposes a hybrid control approach for distribution system critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while MPC models grid operations incorporating RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. We formulate the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The RL algorithm is trained offline using a historical forecast of renewable generation and load demand. The method is tested using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery. Case studies demonstrated that the proposed method outperforms other policies with static operating reserves.

distribution system↗

Shaker-structure interaction modeling and analysis for nonlinear force appropriation testing

Nonlinear force appropriation is an extension of its linear counterpart where sinusoidal excitation is applied to a structure with a modal shaker and phase quadrature is achieved between the excitation and response. While a standard practice in modal testing, modal shaker excitation has the potential to alter the dynamics of the structure under test. Previous studies have been conducted to address several concerns, but this work specifically focuses on a shaker-structure interaction phenomenon which arises during the force appropriation testing of a nonlinear structure. Under pure-tone sinusoidal forcing, a nonlinear structure may respond not only at the fundamental harmonic but also potentially at sub- or superharmonics, or it can even produce aperiodic and chaotic motion in certain cases. Shaker-structure interaction occurs when the response physically pushes back against the shaker attachment, producing non-fundamental harmonic content in the force measured by the load cell, even for pure tone voltage input to the shaker. This work develops a model to replicate these physics and investigates their influence on the response of a nonlinear normal mode of the structure. Experimental evidence is first provided that demonstrates the generation of harmonic content in the measured load cell force during a force appropriation test. This interaction is replicated by developing an electromechanical model of a modal shaker attached to a nonlinear, three-mass dynamical system. Several simulated experiments are conducted both with and without the shaker model in order to identify which effects are specifically due to the presence of the shaker. Finally, the results of these simulations are then compared to the undamped nonlinear normal modes of the structure under test to evaluate the influence of shaker-structure interaction on the identified system’s dynamics.

42 ENGINEERING↗

Network-Aware and Welfare-Maximizing Dynamic Pricing for Energy Sharing: Preprint

The proliferation of behind-the-meter (BTM) distributed energy resources (DER) within the electrical distribution network presents significant supply and demand flexibilities, but also introduces operational challenges such as voltage spikes and reverse power flows. In response, this paper proposes a network-aware dynamic pricing framework tailored for energy-sharing coalitions that aggregate small, but ubiquitous, BTM DER downstream of a distribution system operator's (DSO) revenue meter that adopts a generic net energy metering (NEM) tariff. By formulating a Stackelberg game between the energy-sharing market leader and its prosumers, we show that the dynamic pricing policy induces the prosumers toward a network-safe operation and decentrally maximizes the energysharing social welfare. The dynamic pricing mechanism involves a combination of a locational ex-ante dynamic price and an ex-post allocation, both of which are functions of the energy sharing's BTM DER. The ex-post allocation is proportionate to the price differential between the DSO NEM price and the energy sharing locational price. Simulation results using real DER data and the IEEE 13-bus test systems illustrate the dynamic nature of network-aware pricing at each bus, and its impact on voltage.

energy communities↗

Progress on Optimizing Wind Farms and Rotor Designs Using Adjoints

Modern wind plants are increasingly tasked with multiple performance objectives. In addition to designing plants that maximize power output and minimize the levelized cost of energy (LCOE), the design and operation of wind plants is increasingly influenced by challenges regarding grid integration of variable generation renewables. This places a growing emphasis on making wind plants more controllable and predictable. WindSE is a Reynolds-averaged Navier-Stokes (RANS) model designed around analytical gradient and adjoint methods, with the ability to capture terrain-induced effects, as shown in Figure 1. The recent addition of an unsteady solver with an actuator line method (ALM) and ongoing work to enable massively parallel optimizations gives it a unique niche to explore coupled plant-level controls and design problems. This code is an open source python package built on the FEniCS framework that utilizes fast, parallel PETSc solvers to model fluid flow throughout wind-farm scale domains. Two recent studies performed using WindSE demonstrate the capability to optimize under a wide variety of flow conditions and objective functions. In the first, we present an optimization focused on modifying the layout of a wind farm with a fixed number of turbines for maximum total power output [1]. This study highlights the ability to quickly perform simulations using the steady Navier-Stokes solver combined with rotors represented as actuator disks while also stressing the importance of capturing terrain-induced effects. Gradient-based optimization using the RANS equations is viable due to the inclusion of efficiently computed adjoint derivatives. We interpret the physical results of the optimal layout and also discuss the computational cost of scaling to larger problems. In the second study, we present the capabilities of the unsteady Navier-Stokes solver, where rotor-blade profiles represented by actuator lines are optimized to enhance wake steering effects and overall power production [2]. We quantify the wind plant performance gains obtained from this type of simultaneous control co-design optimization as compared to optimizing the blade design and yaw independently. Figure 2 shows the differences between a baseline two-turbine system and an optimized system where we fine-tune the blade chord profile. Results and challenges from each study are quickly summarized and used to motivate the current development efforts within WindSE. Current and future work is focused on enabling higher-resolution studies with more degrees of freedom through parallelization of both the simulation and optimization algorithms. We present benchmarking results to show that WindSE performs well in both weak- and strong-scaling tests and further demonstrate that the optimizer obtains the same convergence rates in both shared- and distributed-memory environments. Using larger wind farms, we can study deep-array effects within an optimization context, allowing the use of objective functions that have been previously unstudied. As an example, we present ongoing work on a blockage metric which characterizes the loss of available kinetic energy due to wake effects from multiple upstream turbines.

adjoint optimization↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Development of a High-Pressure Fuel Injection System for Use with Propane-DME

Paper details the design approach and performance of a high-pressure common rail fuel injection system used with Propane-DME mixtures targeting high injection pressures on a light duty 2.2L inline-4 compression ignition engine. The study estimates the bulk modulus of elasticity based on the hardware geometry and operating pressures to assess the compressibility of Propane and DME across a range of pressures typical of the LD engine application. The compressibility factor ranges from 500 to 3000 bar, significantly lower than the theoretical values for the conditions tested. The high-pressure pump performance is optimized via the implementation of an inlet metering valve operated on a crank-angle open/close sequence to control pressure at the common rail. The application of a model-based controller and the use of high-speed sampling of rail pressure indicate that pressure at the rail can be attained with the pump metering valve, and without use of the pressure relieve valve present in the rail. Results show a significant reduction on pumping work parasitics and of fuel heating, on the order of 40°C, at typical working conditions with the proposed approach. Injector rates of injection with Propane-DME are very similar to those of Diesel. Paper compares bench data of rates of injection versus simulation predictions across operating pressures of 200 to 1000bar and from injection commands spanning 0.20 to 2.0ms. Furthermore, the accuracy of the model predictions are attributed in part by to the updated fuel compressibility modulus descriptions attained during the testing.

42 ENGINEERING↗

Online Parameter Estimation Methods for Adaptive Cruise Control Systems

Modeling Adaptive Cruise Control (ACC) vehicles enables the understanding of the impact of these vehicles on traffic flow. In this work, two online methods are used to provide real time system identification of ACC enabled vehicles. The first technique is a recursive least squares (RLS) approach, while the second method solves a nonlinear joint state and parameter estimation problem via particle filtering (PF). We provide a parameter identifiability analysis for both methods to analytically show that the model parameters are not identifiable using equilibrium driving. The accuracy and computational runtime of the online methods are compared to a commonly used offline simulation-based optimization (i.e., batch optimization) approach. The methods are tested on synthetic data as well as on empirical data collected directly from a 2019 model year ACC vehicle using data from sensors that are part of the stock ACC system. The online methods are scalable and provide comparable accuracy to the batch method. RLS runs in real time and is two orders of magnitude faster than the batch method for modest sized (e.g., 15 min) datasets. The particle filter also runs in real- time, and is also suitable in streaming applications in which the datasets can grow arbitrarily large.

33 ADVANCED PROPULSION SYSTEMS↗

Deformation mechanisms of ultra-thin Al layers in Al/SiC nanolaminates as a function of thickness and temperature

The mechanical properties of Al/SiC nanolaminates with layer thicknesses between 10 and 100 nm were studied by nanoindentation in the temperature range 25 to 100 °C. The strength of the Al layers as a function of the layer thickness and temperature was obtained from the hardness of the nanolaminates by an inverse methodology based on the numerical simulation of the nanoindentation tests by means of the finite element method. The room temperature yield stress of the Al layers showed a large ‘the thinner, the stronger’ effect, which depended not only on the layer thickness but also on the microstructure, which changed with the Al layer thickness. The yield stress of the Al layers at ambient temperature was compatible with a deformation mechanism controlled by the interaction of dislocations with grain boundaries for the thicker layers (>50 nm), while confined layer slip appeared to be dominant for layers below 50 nm. There was a dramatic reduction in the Al yield stress with temperature, which increased as the Al layer thickness decreased, and led to an inverse size effect at 100 °C. In conclusion, this behavior was compatible with plastic deformation mechanisms controlled by grain boundary and interface diffusion at 100 °C, which limit the strength of the ultra-thin Al layers.

36 MATERIALS SCIENCE↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Universal Design Curves for Elastomeric Direct Ink-Writing Architectures

Direct ink writing of silicone elastomers enables printing with precise control of porosity and mechan- ical properties of ordered cellular solids, suitable for shock absorption and stress mitigation applications. With the ability to manipulate structure and feedstock stiffness, the design space becomes challenging to parse to obtain a solution producing a desired mechanical response. Here we derive an analytical design approach for a specific architecture. Results from finite element simulations and quasi-static mechanical tests of two different parallel strand architectures were analyzed to understand the structure-property relationships under compressive strain. Combining effective stiffness-density scaling with least squares optimization of the stress responses yielded general response curves parameterized by resin modulus and strand spacing. An analytical expression of these curves serves as a reduced order model, which, when optimized, provides a rapid design capability for filament-based 3D printed structures. As a demonstration, the optimal design of a face-centered tetragonal architecture is computed that satisfies prescribed minimum and maximum load constraints.

36 MATERIALS SCIENCE↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗