Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Velocity variations of an equatorial plume throughout a Jovian year

Analysis of features in the Equatorial Zone of Jupiter has shown that the equatorial plume reported by Pioneer 10 has existed for an 11-yr interval. During this interval, the plume has shown an acceleration which can be interpreted as a constant component of 3 hundred-millionths m/sec-squared and a sinusoidal component which anticorrelates with the planetocentric declination of the sun and has an amplitude of -0.96 m/sec per degree change of planetocentric declination. The sinusoidal component has been interpreted in terms of solar heating. Throughout this interval of time, the Equatorial Zone has appeared abnormally dark and has contained many dark projections along the northern edge. When the plume approaches to within 25 to 30 deg of these features, they are deflected in the direction of motion of the plume and then dissipate or become obscured as the plume passes. After passage of the plume, normal features are again observed.

Reese, E.↗

Potentialities of lunar laser range - Differencing for measuring the earth's orientation

An investigation of range differences for their capabilities in determining the orientation of the earth in an earth-moon reference system is presented. Each pair of two coobserving stations forms an observational unit which is preferably located along a meridian or parallel; for a time interval from the instant of the first simultaneous observation of the most eastern line to the last observation of the most western line, a variance analysis shows that the pole position and the earth rotation can be computed independently of errors in the adopted lunar ephemeris. It is concluded that if the stations are within 10 to 15 deg in north-south or east-west direction the standard deviations of the parameters do not increase significantly.

Leick, A.↗

Voids in the Ly-alpha forest

The general issue of using the Ly-alpha absorbers in quasar spectra as tracers of the large-scale matter distribution is discussed, emphasizing complications due to evolutionary effects and line blending. Then, a novel method of statistical analysis of the line data appropriate for studying large-scale structure is described. This method circumvents the problem of line blending by truncating the interval distribution at the low end. It also explicitly takes z-dependent effects into account. As an example, the method is applied to an 18-quasar spectrum sample of 417 lines.

Duncan, Robert C.↗

An April 1991 outburst from 4U0115+63 observed by BATSE

4U0115+63 is a recurrent transient X-ray pulsar in a moderately eccentric orbit with a Be star companion, V635 Cas. Many outbursts from this system have been reported over the past twenty years; yet despite the apparent relation between optical outbursts from the companion star and subsequent X-ray transient events, the physical mechanism for the mass transfer in the system remains unclear. In this paper, we present the preliminary results of analysis of observations made using BATSE during the 1991 April outburst from this system. This outburst does not fit the pattern of three year recurrence intervals previously suggested by Whitlock, Roussel-Dupre and Priedhorsky (1989). The orbital elements of the system have been updated and do not support the claim of Tamura et al., (1992) that apsidal motion was detected in this system based on the 1990 Ginga outburst.

Cominsky, Lynn↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

PSR J0007+7303 in the CTA1I Supenova Remnant: New Gamma-Ray Results from Two Years of Fermi Large Area Telescope Observations

One of the main results of the Fermi Gamma-Ray Space Telescope is the discovery of -ray selected pulsars. The high magnetic field pulsar, PSR J0007+7303 in CTA1, was the first ever to be discovered through its -ray pulsations. Based on analysis of two years of Large Area Telescope (LAT) survey data, we report on the discovery of -ray emission in the off-pulse phase interval at the 6 level. The emission appears to be extended at the 2 level with a disk of extension 0.6. level. The flux from this emission in the energy range E 100 MeV is F 100 = (1.73 0.40stat 0.18sys) 108photonscm2 s1 and is best fitted by a power law with a photon index of = 2.54 0.14stat 0.05sys. The pulsed -ray flux in the same energy range is F 100 = (3.95 0.07stat 0.30sys) 107photonscm2 s1 and is best fitted by an exponentially cutoff power-law spectrum with a photon index of = 1.41 0.23stat 0.03sys and a cutoff energy Ec = 4.04 0.20stat 0.67sysGeV. We find no flux variability either at the 2009 May glitch or in the long-term behavior. We model the -ray light curve with two high-altitude emission models, the outer gap and slot gap, and find that the preferred model depends strongly on the assumed origin of the off-pulse emission. Both models favor a large angle between the magnetic axis and observer line of sight, consistent with the nondetection of radio emission being a geometrical effect. Finally, we discuss how the LAT results bear on the understanding of the cooling of this neutron star.

Abdo, A.↗

Observation of Bernstein Waves Excited by Newborn Interstellar Pickup Ions in the Solar Wind

A recent examination of 1.9 s magnetic field data recorded by the Voyager 2 spacecraft in transit to Jupiter revealed several instances of strongly aliased spectra suggestive of unresolved high-frequency magnetic fluctuations at 4.4 AU. A closer examination of these intervals using the highest resolution data available revealed one clear instance of wave activity at spacecraft frame frequencies from 0.2 to 1 Hz. Using various analysis techniques, we have characterized these fluctuations as Bernstein mode waves excited by newborn interstellar pickup ions. We can find no other interpretation or source consistent with the observations, but this interpretation is not without questions. In this paper, we report a detailed analysis of the waves, including their frequency and polarization, that supports our interpretation.

magnetic fields↗

A FRAMEWORK TO DEVELOP FLAW ACCEPTANCE CRITERIA FOR STRUCTURAL INTEGRITY ASSESSMENT OF MULTIPURPOSE CANISTERS FOR EXTENDED STORAGE OF USED NUCLEAR FUEL

A multipurpose canister (MPC) made of austenitic stainless steel is loaded with used nuclear fuel assemblies and is part of the transfer cask system to move the fuel from the spent fuel pool to prepare for storage, and is part of the storage cask system for on-site dry storage. This weld-sealed canister is also expected to be part of the transportation package following storage. The canister may be subject to service-induced degradation especially if exposed to aggressive environments during possible very long-term storage period if the permanent repository is yet to be identified and readied. Stress corrosion cracking may be initiated on the canister surface in the welds or in the heat affected zone because the construction of MPC does not require heat treatment for stress relief. An acceptance criteria methodology is being developed for flaw disposition should the crack-like defects be detected by periodic Inservice Inspection. The external loading cases include thermal accident scenarios and cask drop conditions with the contribution from the welding residual stresses. The determination of acceptable flaw size is based on the procedure to evaluate flaw stability provided by American Petroleum Institute (API) 579 Fitness-for-Service (Second Edition). The material mechanical and fracture properties for base and weld metals and the stress analysis results are obtained from the open literature such as NUREG-1864. Subcritical crack growth from stress corrosion cracking (SCC), and its impact on inspection intervals and acceptance criteria, is not addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regional Lung Density Changes After Radiation Therapy for Tumors in and Around Thorax

Purpose: To study the temporal nature of regional lung density changes and to assess whether the dose-dependent nature of these changes is associated with patient- and treatment-associated factors. Methods and Materials: Between 1991 and 2004, 118 patients with interpretable pre- and post-radiation therapy (RT) chest computed tomography (CT) scans were evaluated. Changes in regional lung density were related to regional dose to define a dose-response curve (DRC) for RT-induced lung injury using three-dimensional planning tools and image fusion. Multiple post-RT follow-up CT scans were evaluated by fitting linear-quadratic models of density changes on dose with time as the covariate. Various patient- and treatment-related factors were examined as well. Results: There was a dose-dependent increase in regional lung density at nearly all post-RT follow-up intervals. The population volume-weighted changes evolved over the initial 6-month period after RT and reached a plateau thereafter (p < 0.001). On univariate analysis, patient age greater than 65 years (p = 0.003) and/or the use of pre-RT surgery (p < 0.001) were associated with significantly greater changes in CT density at both 6 and 12 months after RT, but the magnitude of this effect was modest. Conclusions: There appears to be a temporal nature for the dose-dependent increases in lung density. Nondosimetric clinical factors tend to have no, or a modest, impact on these changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compilation and Analysis of 20 and 30 GHz Rain Fade Events at the ACTS NASA Ground Station: Statistics and Model Assessment

The purpose of the propagation studies within the ACTS Project Office is to acquire 20 and 30 GHz rain fade statistics using the ACTS beacon links received at the NGS (NASA Ground Station) in Cleveland. Other than the raw, statistically unprocessed rain fade events that occur in real time, relevant rain fade statistics derived from such events are the cumulative rain fade statistics as well as fade duration statistics (beyond given fade thresholds) over monthly and yearly time intervals. Concurrent with the data logging exercise, monthly maximum rainfall levels recorded at the US Weather Service at Hopkins Airport are appended to the database to facilitate comparison of observed fade statistics with those predicted by the ACTS Rain Attenuation Model. Also, the raw fade data will be in a format, complete with documentation, for use by other investigators who require realistic fade event evolution in time for simulation purposes or further analysis for comparisons with other rain fade prediction models, etc. The raw time series data from the 20 and 30 GHz beacon signals is purged of non relevant data intervals where no rain fading has occurred. All other data intervals which contain rain fade events are archived with the accompanying time stamps. The definition of just what constitutes a rain fade event will be discussed later. The archived data serves two purposes. First, all rain fade event data is recombined into a contiguous data series every month and every year; this will represent an uninterrupted record of the actual (i.e., not statistically processed) temporal evolution of rain fade at 20 and 30 GHz at the location of the NGS. The second purpose of the data in such a format is to enable a statistical analysis of prevailing propagation parameters such as cumulative distributions of attenuation on a monthly and yearly basis as well as fade duration probabilities below given fade thresholds, also on a monthly and yearly basis. In addition, various subsidiary statistics such as attenuation rate probabilities are derived. The purged raw rain fade data as well as the results of the analyzed data will be made available for use by parties in the private sector upon their request. The process which will be followed in this dissemination is outlined in this paper.

Manning, Robert M.↗

The Percent of Positive Biopsy Cores Improves Prediction of Prostate Cancer-Specific Death in Patients Treated With Dose-Escalated Radiotherapy

Purpose: To examine the prognostic utility of the percentage of positive cores (PPC) at the time of prostate biopsy for patients treated with dose-escalated external beam radiation therapy. Methods and Materials: We performed a retrospective analysis of patients treated at University of Michigan Medical Center to at least 75 Gy. Patients were stratified according to PPC by quartile, and freedom from biochemical failure (nadir + 2 ng/mL), freedom from metastasis (FFM), cause-specific survival (CSS), and overall survival (OS) were assessed by log-rank test. Receiver operator characteristic (ROC) curve analysis was used to determine the optimal cut point for PPC stratification. Finally, Cox proportional hazards multivariate regression was used to assess the impact of PPC on clinical outcome when adjusting for National Comprehensive Cancer Network (NCCN) risk group and androgen deprivation therapy. Results: PPC information was available for 651 patients. Increasing-risk features including T stage, prostate-specific antigen, Gleason score, and NCCN risk group were all directly correlated with increasing PPC. On log-rank evaluation, all clinical endpoints, except for OS, were associated with PPC by quartile, with worse clinical outcomes as PPC increased, with the greatest impact seen in the highest quartile (>66.7% of cores positive). ROC curve analysis confirmed that a cut point using two-thirds positive cores was most closely associated with CSS (p = 0.002; area under ROC curve, 0.71). On univariate analysis, stratifying patients according to PPC less than or equal to 66.7% vs. PPC greater than 66.7% was prognostic for freedom from biochemical failure (p = 0.0001), FFM (p = 0.0002), and CSS (p = 0.0003) and marginally prognostic for OS (p = 0.055). On multivariate analysis, after adjustment for NCCN risk group and androgen deprivation therapy use, PPC greater than 66.7% increased the risk for biochemical failure (p = 0.0001; hazard ratio [HR], 2.1 [95% confidence interval (CI), 1.4-3.0]) and FFM (p = 0.05; HR, 1.7 [95% CI, 1.1-2.9]) and marginally increased the risk for CSS (p = 0.057; HR, 2.1 [95% CI, 1.0-4.6]). Conclusion: PPC at the time of biopsy adds prognostic value for clinically meaningful endpoints for patients treated with dose-escalated radiation therapy. This was particularly true for NCCN-defined intermediate- and high-risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency

Based on the mode-coupling method, numerical analysis is presented to demonstrate the influence of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency. Results show that the interval between the band-gaps of the competing mode and the desired working mode is narrowed by use of positive-taper ripples, but is expanded if negative-taper ripples are employed, and the influence of the negative-taper ripples is obviously more advantageous than the positive-taper ripples; the band-gap overlap of modes can be efficiently separated by use of negative-taper ripples. The residual side-lobes of the frequency response in a coaxial Bragg structure with ripple taper also can be effectively suppressed by employing the windowing-function technique. These peculiarities provide potential advantage in constructing a coaxial Bragg cavity with high quality factor for single higher-order-mode operation of a high-power free-electron maser in the terahertz frequency range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utah FORGE 2439: A Multi-Component Approach to Characterizing In-Situ Stress

Core-based in-situ stress estimation, Triaxial Ultrasonic Velocity (labTUV) data, and Deformation Rate Analysis (DRA) data for Utah FORGE well 16A(78)-32 using triaxial ultrasonic velocity and deformation rate analysis. Report documenting a multi-component approach to characterizing in-situ stress at the U.S. DOE FORGE EGS site: laboratory, modeling and field measurement. Core-based methods for in-situ stress estimation were applied using samples from 5 intervals within the Utah FORGE 16A(78)-32 well. At three of these locations, Triaxial Ultrasonic Velocity (labTUV) tests were performed, resulting in experimentally-determined relationships between wave velocities and stresses. Non-monotonic increase in the velocity-stress relationships are inferred provide evidence of stress history and are therefore used to estimate in-situ stress magnitudes. Additionally, Deformation Rate Analysis (DRA) tests were run on core plugs from various orientations at each of the 5 sampling locations. These, too, provide evidence of stress history based on stress-strain behavior. A novel Weight of Evidence (WoE) method was developed as a means of synthesizing in-situ stress evidence from these two types of tests. Results indicate the minimum horizontal stress gradient ranges from 0.58 psi/ft to 0.69 psi/ft, with 4 of the 5 values between 0.66 psi/ft and 0.69 psi/ft. The vertical stress gradient ranges from 1.05 psi/ft to 1.12 psi/ft, with 4 of the 5 zones given results between 1.09 psi/ft and 1.12 psi/ft. The maximum horizontal stress gradient ranges from 0.98 psi/ft to 1.34 psi/ft, with 4 of the 5 zones falling between 0.98 psi/ft and 1.24 psi/ft. The stress regime thus appears to be on the edge between normal faulting and strike-slip faulting, potentially flipping back and forth between the two regimes due to variability of rock properties, structures such as faults, and/or thermal anomalies.

15 GEOTHERMAL ENERGY↗

Lack of a Dose-Effect Relationship for Pulmonary Function Changes After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: To evaluate the influence of tumor size, prescription dose, and dose to the lungs on posttreatment pulmonary function test (PFT) changes after stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC). Methods and Materials: The analysis is based on 191 patients treated at 5 international institutions: inclusion criteria were availability of pre- and post-SBRT PFTs and dose-volume histograms of the lung and planning target volume (PTV); patients treated with more than 1 SBRT course were excluded. Correlation between early (1-6 months, median 3 months) and late (7-24 months, median 12 months) PFT changes and tumor size, planning target volume (PTV) dose, and lung doses was assessed using linear regression analysis, receiver operating characteristics analysis, and Lyman's normal tissue complication probability model. The PTV doses were converted to biologically effective doses and lung doses to 2 Gy equivalent doses before correlation analyses. Results: Up to 6 months after SBRT, forced expiratory volume in 1 second and carbon monoxide diffusion capacity changed by −1.4% (95% confidence interval [CI], −3.4% to 0) and −7.6% (95% CI, −10.2% to −3.4%) compared with pretreatment values, respectively. A modest decrease in PFTs was observed 7-24 months after SBRT, with changes of −8.1% (95% CI, −13.3% to −5.3%) and −12.4% (95% CI, −15.5% to −6.9%), respectively. Using linear regression analysis, receiver operating characteristic analysis, and normal tissue complication probability modeling, all evaluated parameters of tumor size, PTV dose, mean lung dose, and absolute and relative volumes of the lung exposed to minimum doses of 5-70 Gy were not correlated with early and late PFT changes. Subgroup analysis based on pre-SBRT PFTs (greater or equal and less than median) did not identify any dose-effect relationship. Conclusions: This study failed to demonstrate a significant dose-effect relationship for changes of pulmonary function after SBRT for early-stage non-small cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE BOSS EMISSION-LINE LENS SURVEY. II. INVESTIGATING MASS-DENSITY PROFILE EVOLUTION IN THE SLACS+BELLS STRONG GRAVITATIONAL LENS SAMPLE

We present an analysis of the evolution of the central mass-density profile of massive elliptical galaxies from the SLACS and BELLS strong gravitational lens samples over the redshift interval z Almost-Equal-To 0.1-0.6, based on the combination of strong-lensing aperture mass and stellar velocity-dispersion constraints. We find a significant trend toward steeper mass profiles (parameterized by the power-law density model with {rho}{proportional_to}r {sup -{gamma}}) at later cosmic times, with magnitude d < {gamma} > /dz = -0.60 {+-} 0.15. We show that the combined lens-galaxy sample is consistent with a non-evolving distribution of stellar velocity dispersions. Considering possible additional dependence of <{gamma} > on lens-galaxy stellar mass, effective radius, and Sersic index, we find marginal evidence for shallower mass profiles at higher masses and larger sizes, but with a significance that is subdominant to the redshift dependence. Using the results of published Monte Carlo simulations of spectroscopic lens surveys, we verify that our mass-profile evolution result cannot be explained by lensing selection biases as a function of redshift. Interpreted as a true evolutionary signal, our result suggests that major dry mergers involving off-axis trajectories play a significant role in the evolution of the average mass-density structure of massive early-type galaxies over the past 6 Gyr. We also consider an alternative non-evolutionary hypothesis based on variations in the strong-lensing measurement aperture with redshift, which would imply the detection of an 'inflection zone' marking the transition between the baryon-dominated and dark-matter halo-dominated regions of the lens galaxies. Further observations of the combined SLACS+BELLS sample can constrain this picture more precisely, and enable a more detailed investigation of the multivariate dependences of galaxy mass structure across cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface analysis insight note: Synthetic line shapes, integration regions and relative sensitivity factors

Here, methods for estimating photoemission intensity from X-ray photoelectron spectroscopy data are examined. The role played by “synthetic” bell-shaped curves, integration intervals, background curves, and the use of relative sensitivity factors (RSFs) in reporting percentage atomic concentration for a sample is presented. In particular, photoemission lines with differing energy distributions obtained from the NaCl sample surface are used to demonstrate how a comparison of photoemission intensities is dependent on the line shapes, background curves, and appropriate use of RSFs.

42 ENGINEERING↗