Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

pnnl-predictive-phenomics/csc052-gem

Genome-Scale Metabolic Model Continuous Validation with Memote for CarbStor Community Member Bacillus These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity.

Torres, Victor E.↗

pnnl-predictive-phenomics/csc031-gem

Genome-Scale Metabolic Model of CarbStor Community member Microbacterium (csc031) Continuous Validation with Memote These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity

McNaughton, Andrew [@PNNL]↗

pnnl-predictive-phenomics/csc009-gem

Genome-Scale Metabolic Model of CarbStore Community member Curtobacterium (csc009) Continuous Validation with Memote These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity

Lin, Tesia↗

pnnl-predictive-phenomics/csc040-gem

Genome-Scale Metabolic Model Continuous Validation with Memote for CarbStor Community Member Rhodococcus These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity.

McNaughton, Andrew [@PNNL]↗

pnnl-predictive-phenomics/csc043-gem

Genome-Scale Metabolic Model Continuous Validation with Memote for CarbStor Community Member Paenibacillus These repositories contain the continuous validation environment for an organism-specific genome-scale metabolic model (GEM) using Memote. Memote is a software tool that provides a suite of tests to ensure the quality and consistency of metabolic models. By integrating Memote into a continuous integration (CI) workflow, we can automatically validate updates to the GEM, ensuring that model modifications improve or maintain the model's integrity.

Zucker, Jeremy [Pacific Northwest National Laborat↗

Data and Tools for Energy Planning and Analysis

The National Renewable Energy Laboratory (NREL) creates widely used data and tools to facilitate energy system planning and analysis. These software tools have been developed for complex research problems and perfected over real-world applications and laboratory validations. Some tools are award winners, others are open-source data explorers, and all are rigorously designed to empower decision-makers with accurate and accessible information. This software selection shows how NREL resources can help stakeholders achieve a clean, just, and resilient energy transformation.

data↗

A Revised Validation Process for Ice Accretion Codes

A research project is underway at NASA Glenn to produce computer software that can accurately predict ice growth under any meteorological conditions for any aircraft surface. This report will present results from the latest LEWICE release, version 3.5. This program differs from previous releases in its ability to model mixed phase and ice crystal conditions such as those encountered inside an engine. It also has expanded capability to use structured grids and a new capability to use results from unstructured grid flow solvers. A quantitative comparison of the results against a database of ice shapes that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has also been performed. This paper will extend the comparison of ice shapes between LEWICE 3.5 and experimental data from a previous paper. Comparisons of lift and drag are made between experimentally collected data from experimentally obtained ice shapes and simulated (CFD) data on simulated (LEWICE) ice shapes. Comparisons are also made between experimentally collected and simulated performance data on select experimental ice shapes to ensure the CFD solver, FUN3D, is valid within the flight regime. The results show that the predicted results are within the accuracy limits of the experimental data for the majority of cases.

turbulent heat flux↗

Software for Generating Strip Maps from SAR Data

Jurassicprok is a computer program that generates strip-map digital elevation models and other data products from raw data acquired by an airborne synthetic-aperture radar (SAR) system. This software can process data from a variety of airborne SAR systems but is designed especially for the GeoSAR system, which is a dual-frequency (P- and X-band), single-pass interferometric SAR system for measuring elevation both at the bare ground surface and top of the vegetation canopy. Jurassicprok is a modified version of software developed previously for airborne-interferometric- SAR applications. The modifications were made to accommodate P-band interferometric processing, remove approximations that are not generally valid, and reduce processor-induced mapping errors to the centimeter level. Major additions and other improvements over the prior software include the following: a) A new, highly efficient multi-stage-modified wave-domain processing algorithm for accurately motion compensating ultra-wideband data; b) Adaptive regridding algorithms based on estimated noise and actual measured topography to reduce noise while maintaining spatial resolution; c) Exact expressions for height determination from interferogram data; d) Fully calibrated volumetric correlation data based on rigorous removal of geometric and signal-to-noise decorrelation terms; e) Strip range-Doppler image output in user-specified Doppler coordinates; f) An improved phase-unwrapping and absolute-phase-determination algorithm; g) A more flexible user interface with many additional processing options; h) Increased interferogram filtering options; and i) Ability to use disk space instead of random- access memory for some processing steps.

Hensley, Scott↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Canister Corrosion Detection

The software titled "nccd" is used for running residual neural networks (ResNets) on images of nuclear canisters. The software provides only the code for the implementation (based on the fastai library), but it does not share the image data. The compute code allows the use of residual nets (and more generally of other deep learning models) for classifying images from nuclear canisters as corroded. or intact. An image is considered to be corroded if it contains pitting or stress corrosion cracks. The code trains ResNets on image tiles extracted from original images from nuclear canisters, and then implements a classification rule, which can be applied to a validation set to decide if each original image is corroded or intact. The software automates the process of using images taken from nuclear canisters to detect corrosion. It provides also scope for future research directions on the basis of the existing research and code.

Papamarkou, Theodore↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Flight Evaluation of the Traffic Aware Planner on the NASA HU-25A Guardian Aircraft

NASA’s Traffic Aware Planner (TAP) software is a research-prototype decision support tool that provides pilots with time- and fuel-saving route recommendations that optimize their current trajectory. The software runs on a first-of-a-kind system architecture onboard three aircraft in revenue service conducting operational evaluations with a major domestic airline. Therefore, significant NASA-internal testing is required prior to releasing the software to the partner airline. This paper describes a flight test plan that exercises the functionality of the TAP software in a representative operational environment, describes the system architecture developed and implemented for the NASA Langley HU-25A Guardian aircraft to support the test objectives, presents outcomes of the flight test campaign, and discusses use cases that demonstrate the value of flight testing for this activity.Research into flight path optimization of transport aircraft conducted by the National Aeronautics and SpaceAdministration (NASA) has produced an operational concept known as Traffic Aware Strategic Aircrew Requests(TASAR) [1, 2]. This near-term concept [3] provides the aircrew with a flight deck decision support tool known asthe Traffic Aware Planner (TAP). The TAP software leverages a growing number of information sources on the flightdeck to make time- and fuel-saving route optimization recommendations to the aircrew while en route. The aircrewcan then use the suggestions provided by the tool to make route change requests with a greater likelihood of acceptanceby air traffic control (ATC). Since TASAR is a concept intended for the current operational environment, it isintentionally designed to have no safety-critical impact or require any changes to current Federal AviationAdministration (FAA) rules and procedures [4, 5].The research prototype TAP system [6–8], explained further in Section III.C, continually incorporates up-to-dateaircraft state data from onboard avionics, as well as the latest position of surrounding traffic, the most recent windforecast, and the most recent convective weather forecast, in order to calculate candidate trajectory modifications thatimprove upon the current active route. These trajectories account for user-selectable objective functions [3] of reducedfuel burn, reduced flight time, or an airline-derived combination of factors known as trip cost. Previous analyses andsimulations have estimated substantial savings for airlines employing this technique within the U.S. National AirspaceSystem (NAS) [9–11]. Operational evaluations with Alaska Airlines seek to validate these projected benefits usingmeasured data while simultaneously providing benefits to the airline [12, 13].The TAP software has undergone a number of human-in-the-loop simulations [14] and flight test activities[15–17] in order to validate the operational concept, evaluate human factors considerations (e.g., workload, usability,distraction, etc.), and to assess the ability of the software to function in a representative operational environment (e.g.,connected to live avionics data, using in-flight internet connectivity, etc.). However, these simulations and flight testcampaigns did not account for the hardware architecture implemented on the three aircraft for Alaska Airlines’operational evaluations of the TAP software. Therefore, a need was identified to thoroughly test the functionality ofthe software in a similar hardware architecture to that of the partner airline’s aircraft. Information regarding testapparatus and environments used to evaluate TAP prior to testing on the HU-25A can be found in reference [18].A campaign of flight trials on a NASA aircraft, the HU-25A Guardian, was conducted to ensure that the researchprototype TAP system functions well in a configuration similar to the Alaska Airlines aircraft prior to deployment.This airborne, networked environment enables an assessment of the operational factors unique to the flight environment. Additionally, this activity evaluated the effectiveness and benefit of new TAP functionality andoperation in a relevant flight environment while allowing the rapid prototyping of new concepts and features.This paper is organized as follows: Section II discusses the details of the flight test plan, flight profiles, and theduties of personnel involved with conducting flight operations. Section III describes the test platform, avionicsequipage, and system architecture. Section IV presents a discussion of results, and Section V contains concludingremarks.

Underwood, Matthew C.↗

On the mirror instability in the presence of electron temperature anisotropy

Computation of the mirror instability growth rate in an ion-electron bi-Maxwellian plasma is revisited, starting from the low-frequency kinetic theory. The role of the electron finite Larmor radius (FLR) effects on the instability quenching is shown to possibly be dominant, even near threshold where the smallest unstable scales significantly exceed the electron gyroscale. Validation of the results by comparison with predictions of the fully kinetic whamp software is also presented. The influence of the electron temperatures on the ion FLR effects very near threshold, where the electron kinetic effects are negligible, is also pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of square-root filtering for spacecraft attitude control

Suitable digital algorithms are developed and tested for providing on-board precision attitude estimation and pointing control for potential use in the Landsat-D spacecraft. These algorithms provide pointing accuracy of better than 0.01 deg. To obtain necessary precision with efficient software, a six state-variable square-root Kalman filter combines two star tracker measurements to update attitude estimates obtained from processing three gyro outputs. The validity of the estimation and control algorithms are established, and the sensitivity of their performance to various error sources and software parameters are investigated by detailed digital simulation. Spacecraft computer memory, cycle time, and accuracy requirements are estimated.

Sorensen, J. A.↗

Applying Formal Methods and Object-Oriented Design to Existing Flight Software

This paper describes a project appling formal methods to a portion of the shuttle on-orbit digital autopilot (DAP). Three objectives of the project were to: demonstrate the use of formal methods on a shuttle application, facilitate the incorporation and validation of new requirements for the system, and verify the safety-critical properties to be exhibited by the software.

Software Failures↗

The first measurements of soft x-ray flux from ignition scale Hohlraums at the National Ignition Facility using DANTE (invited)

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an {approx}20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30{+-}10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of {approx}2x10{sup 15} W/cm{sup 2} for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1x10{sup 14} W/cm{sup 2} over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to {+-}5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30{+-}10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and tuning of the CMS full simulation

The CMS simulation, based on the Geant4 toolkit, has been operational within the new CMS software framework for more than four years. The description of the detector, including the forward regions, has been completed. A detailed investigation of detector positioning and material budget is underway using collision data. Detailed modelling of detector noise has been performed and validated with the collision data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-209-06: Improving X-Ray Imaging with Computer Vision and Augmented Reality

Purpose: To determine the feasibility of using a computer vision algorithm and augmented reality interface to reduce repeat rates and improve consistency of image quality and patient exposure in general radiography. Methods: A prototype device, designed for use with commercially available hardware (Microsoft Kinect 2.0) capable of depth sensing and high resolution/frame rate video, was mounted to the x-ray tube housing as part of a Philips DigitalDiagnost digital radiography room. Depth data and video was streamed to a Windows 10 PC. Proprietary software created an augmented reality interface where overlays displayed selectable information projected over real-time video of the patient. The information displayed prior to and during x-ray acquisition included: recognition and position of ordered body part, position of image receptor, thickness of anatomy, location of AEC cells, collimated x-ray field, degree of patient motion and suggested x-ray technique. Pre-clinical data was collected in a volunteer study to validate patient thickness measurements and x-ray images were not acquired. Results: Proprietary software correctly identified ordered body part, measured patient motion, and calculated thickness of anatomy. Pre-clinical data demonstrated accuracy and precision of body part thickness measurement when compared with other methods (e.g. laser measurement tool). Thickness measurements provided the basis for developing a database of thickness-based technique charts that can be automatically displayed to the technologist. Conclusion: The utilization of computer vision and commercial hardware to create an augmented reality view of the patient and imaging equipment has the potential to drastically improve the quality and safety of x-ray imaging by reducing repeats and optimizing technique based on patient thickness. Society of Pediatric Radiology Pilot Grant; Washington University Bear Cub Fund.

60 APPLIED LIFE SCIENCES↗