Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMBUSTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Concentric catalytic combustor

A catalytic combustor (28) includes a tubular pressure boundary element (90) having a longitudinal flow axis (e.g., 56) separating a first portion (94) of a first fluid flow (e.g., 24) from a second portion (95) of the first fluid flow. The pressure boundary element includes a wall (96) having a plurality of separate longitudinally oriented flow paths (98) annularly disposed within the wall and conducting respective portions (100, 101) of a second fluid flow (e.g., 26) therethrough. A catalytic material (32) is disposed on a surface (e.g., 102, 103) of the pressure boundary element exposed to at least one of the first and second portions of the first fluid flow.

42 ENGINEERING↗

Temporally resolved planar measurements of transient phenomena in a partially pre-mixed swirl flame in a gas turbine model combustor

This paper presents observations and analysis of the time-dependent behavior of a 10 kW partially pre-mixed, swirl-stabilized methane-air flame exhibiting self-excited thermo-acoustic oscillations. This analysis is based on a series of measurements wherein particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) of the OH radical were performed simultaneously at 5 kHz repetition rate over durations of 0.8 s. Chemiluminescence imaging of the OH{sup *} radical was performed separately, also at 5 kHz over 0.8 s acquisition runs. These measurements were of sufficient sampling frequency and duration to extract usable spatial and temporal frequency information on the medium to large-scale flow-field and heat-release characteristics of the flame. This analysis is used to more fully characterize the interaction between the self-excited thermo-acoustic oscillations and the dominant flow-field structure of this flame, a precessing vortex core (PVC) present in the inner recirculation zone. Interpretation of individual measurement sequences yielded insight into various physical phenomena and the underlying mechanisms driving flame dynamics. It is observed for this flame that location of the reaction zone tracks large-scale fluctuations in axial velocity and also conforms to the passage of large-scale vortical structures through the flow-field. Local extinction of the reaction zone in regions of persistently high principal compressive strain is observed. Such extinctions, however, are seen to be self healing and thus do not induce blowout. Indications of auto-ignition in regions of unburned gas near the exit are also observed. Probable auto-ignition events are frequently observed coincident with the centers of large-scale vortical structures, suggesting the phenomenon is linked to the enhanced mixing and longer residence times associated with fluid at the core of the PVC as it moves through the flame. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of mesh resolution on large eddy simulation of reacting flows in complex geometry combustors

The power of current parallel computers is becoming sufficient to apply large eddy simulation (LES) tools to reacting flows not only in academic configurations but also in real gas turbine chambers. The most limiting factor in performing LES of real systems is the mesh size, which directly controls the overall cost of the simulation, so that the effects of mesh resolution on LES results become a key issue. In the present work, an unstructured compressible LES solver is used to compute the reacting flow in a domain corresponding to a sector of a realistic helicopter chamber. Three grids ranging from 1.2 to 44 million elements are used for LES and results are compared in terms of mean and fluctuating fields as well as of pressure spectra. Results show that the mean temperature, reaction rate, and velocity fields are almost insensitive to the grid size. The RMS field of the resolved velocity is also reasonably independent of the mesh, while the RMS fields of temperature exhibit more sensitivity to the grid, as expected from the fact that most of the combustion process proceeds at small scales. The acoustic field exhibits a limited sensitivity to the mesh, suggesting that LES is adapted to the computation of combustion instabilities in complex systems. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optical method of measuring the temperature in a fluidised bed combustor

The paper analyses the dynamic aspects of the temperature field in a fluidised bed of solids particles (e.g., sand) in which a gaseous fuel is being burned. Such a hot bed emits electromagnetic radiation within the visible range and this can be recorded using a digital video camera. This fact has been used to develop a method for measuring the bed's temperature in the line of sight, through the quartz sides of the reactor. A solid probe is only used for calibration. Video recordings were obtained covering different regions of the bed over three wavelength bands, red, green and blue. In the course of an experiment, the mean temperature of the bed, measured with thermocouples, was raised from ambient to 1300 K, at a rate of {proportional_to} 1 K/s. The data collected were used for calibration, with the brightness of individual pixels converted to a temperature scale. The calibration can then be used to investigate the dynamic temperature distribution within the field of view, in individual elements of the bed. This can also help the study of heat transfer in the bed, its distribution and dissipation. Using this method, it is possible to make direct observations of the intermittent combustion of gaseous fuels in a bubbling fluidised bed. The results provide direct proof that the temperature gradients observed within such beds are associated with exothermic processes within fast moving bubbles. The method could be adapted to studying, e.g., the combustion of solid fuels. (author)

42 ENGINEERING↗

Controlling pollutant emissions in a high-pressure combustor with fuel-diluent blending

This paper investigates the formation of nitric oxide (NO) and carbon monoxide (CO) emissions as a function of nitrogen (N 2 ) or carbon dioxide (CO 2 ) diluent content, added to a premixed reacting jet in crossflow. Here, reaction characteristics of a rich methane-air jet injected into a lean vitiated crossflow were analyzed at an elevated pressure of 5 atm. The jet was pre-heated and enriched with 0%, 15%, 30%, and 50% mass fraction to quantify the effect on pollutant emissions. Simulated results of the full chemistry Star-CCM+CFD model were verified with data taken in the experimental high-pressure combustion facility, which provides pressure, temperature and velocity profiles, as well as line-of-sight chemiluminescence and exit emission measurements. The analysis revealed the significant influence of the diluent to delay axial combustion; this mixing delay increased the axial flame lift-off and controlled any thermal ignition limitations. Increasing the diluent content increased the timescale for the flame to stabilize, which allowed for greater entrainment of crossflow oxidizer into the axial jet stream, and led to decreased pollutant emissions. Hence, crossflow entrainment is a critical driving force at high diluent content. Local nitric oxide (NO) emission formation in the axial stage was predicted numerically, showing the correlation between diluent addition, axial heat release, and the formation of nitric oxide pollution. The high diluent levels leaned out the jet mixture and delayed axial combustion, while reducing prompt and thermal NOx by mitigating flame hotspots and minimizing the timescale that the products remain at high temperatures.

03 NATURAL GAS↗

Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

This paper presents results from tests in a flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include combustion efficiency from gaseous emission measurements, 2D planar laser-based imaging as well as basic flow visualization of the flame. Four inlet test conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics Project and Environmentally Responsible Aviation Program. One inlet condition was a pilot-only test point. The other three inlet conditions incorporated fuel staging via a split between the pilot and main circuits of either 10%/90% or 20%/80%. For each engine power condition, three fuel mixes were used: 100% JP-8; 100% alternative; and a blend of the two, containing 75% alternative. Results for the inlet cases that have fuel split between pilot and main, indicate that fuel from the pilot appears to be evaporated by the time it reaches the dome exit. Main circuit liquid evaporates within a downstream distance equal to annulus height, no matter the fuel. Some fuel fluorescence images for a 10%/90% fuel staging case show a distinct difference between JP-8 and bio-derived fuel. OH PLIF results indicate that OH forms in a region more centrally-located for the JP-8 case downstream of the pilot, in its central recirculation region (CRZ). For the bio-derived Hydrotreated Renewable Jet (HRJ) fuel, however, we do not see much OH in the CRZ. The OH image structure near the dome exit is similar for the two fuels, but farther downstream the OH in the CRZ is much more apparent for the JP-8 than for the alternate fuel. For all conditions, there was no discernable difference between fuel types in combustion efficiency or emissions.

gas turbine combustors↗

A Comparison of Three Second-generation Swirl-Venturi Lean Direct Injection Combustor Concepts

Three variations of a low emissions aircraft gas turbine engine combustion concept were developed and tested. The concept is a second generation swirl-venturi lean direct injection (SV-LDI) concept. LDI is a lean-burn combustion concept in which the fuel is injected directly into the flame zone. All three variations were based on the baseline 9- point SV-LDI configuration reported previously. The three second generation SV-LDI variations are called the 5-recess configuration, the flat dome configuration, and the 9- recess configuration. These three configurations were tested in a NASA Glenn Research Center medium pressure flametube. All three second generation variations had better low power operability than the baseline 9-point configuration. All three configurations had low NO(sub x) emissions, with the 5-recess configuration generally having slightly lower NO(x) than the flat dome or 9-recess configurations. Due to the limitations of the flametube that prevented testing at pressures above 20 atm, correlation equations were developed for the at dome and 9-recess configurations so that the landing-takeoff NO(sub x) emissions could be estimated. The flat dome and 9-recess landing-takeoff NO(x) emissions are estimated to be 81-88% below the CAEP/6 standards, exceeding the project goal of 75% reduction.

combustor↗

Alternative Bio-Derived JP-8 Class Fuel and JP-8 Fuel: Flame Tube Combustor Test Results Compared using a GE TAPS Injector Configuration

This paper presents results from tests in a NASA Glenn Research Center (GRC) flame tube facility, where a bio-derived alternate fuel was compared with JP-8 for emissions and general combustion performance. A research version of General Electric Aviation (GE) TAPS injector was used for the tests. Results include 2D, planar laser-based imaging as well as basic flow visualization of the flame. Four conditions were selected that simulate various engine power conditions relevant to NASA Fundamental Aeronautics Supersonics and Environmentally Responsible Aviation Projects were tested.

optical diagnostics↗

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Two different configurations of a 7-point lean direct injector array were investigated. Chemiluminescence images of C2* or CH* were collected during combustion tests for insight on flame structure for the two configurations. Several inlet conditions were tested by varying the equivalence ratio or reference velocity. For the center right-hand 60 degree and outer right-hand 52 degree outers, the chemiluminescence emanating from the central pilot appeared well isolated from the outers. At the same time, a hollow region below the pilot showed little fluctuation of chemiluminescence where a central recirculation zone was present during the non-reacting tests. The central left-hand 60 degree and outer right-hand 52 degree configuration displayed a narrower structure from the pilot compared to the flatter pilot observed in the other configuration. Additionally, the right-handed outer swirlers may be responsible for the asymmetry observed with the chemiluminescence images. Both configurations showed less variation in chemiluminescence intensity as the reference velocity was increased. This was likely due to better atomization and vaporization associated with higher fuel and air flow rates.

lean direct injection↗

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

This paper reports results for a 7-point lean direct injector (LDI) array for a particular configuration. The LDI configuration in this study used a 60 degrees center pilot swirler and 52.5 degrees on the six outer swirlers. Chemiluminescence images of C2 and CH were collected at a frame rate of 25 Hz using an intensified CCD camera. Narrow bandwidth filters were coupled with the CCD camera in order to spectrally isolate C2 and CH signals. C2 was captured at 515 nm, and the CH signal was acquired at 430 nm. Six inlet conditions were considered in this study, all with the same inlet pressure, 75 psia, and same inlet temperature, 800 degcrees Fahrenheit. These conditions aimed to observe the effect of equivalence ratio, fuel staging, and reference velocity on C2 and CH emissions. Based on the chemiluminescence images, the changes in the inlet conditions was evident in both the pilot and outers. Additionally, the pilot (center injector element) appeared well isolated from the six outer elements under all test conditions.

lean direct injection↗

Deep Neural Network Based Unsteady Flamelet Progress Variable Approach in a Supersonic Combustor

Higher dimensional flamelet manifolds are essential in capturing the coupled effects of pressure gradients and unsteady chemical kinetics observed in supersonic combustion applications. Previous studies have validated the feasibility of using deep neural networks as an alternative to computation-ally intensive multidimensional flamelet table storage and lookup. This approach has demonstrated a significant reduction in memory footprint and enabled the use of larger dimensional tabulated manifolds for supersonic combustion in canonical problems. In this study, the Unsteady Flamelet Progress Variable (UFPV)-ANN model implemented in the VULCAN-CFD code is validated by the Burrows-Kurkov supersonic mixing/combustion configuration. The well characterized experimental problem consists of hydrogen injection into a supersonic vitiated crossflow that results in a lifted flame structure. The initial model consists of a 4-dimensional table where the independent variables Z, C, Xst, P are tabulated using an unsteady flamelet code with boundary conditions corresponding to the vitiated air conditions. The results show the development of a lifted flame structure and over-all acceptable agreement with finite-rate chemistry (FRC) simulation and the experimental data. Moreover, direct mapping between the independent variables and the flamelet table is replaced by a deep neural network for significant memory reduction. The results indicate that the UFPV-ANN approach can retrieve the same solution as the memory intensive lookup table approach.

Flamelet↗

TIME-VARYING FLAME IONIZATION SENSING APPLIED TO NATURAL GAS AND PROPANE BLENDS IN A PRESSURIZED LEAN PREMIXED (LPM) COMBUSTOR

In-situ monitoring of combustion phenomena is a critical need for optimal operation and control of advanced gas turbine combustion systems. The concept described in this paper is based on naturally occurring flame ionization processes that accompany the combustion of hydrocarbon fuels. Previous work has shown that flame ionization techniques may be applied to detect flashback, lean blowout, and some aspects of thermo-acoustic combustion instabilities. Previous work has focused on application of DC electric fields. By application of time-varying electric fields, significant improvements to sensor capabilities have been observed. These data have been collected in a lean premixed combustion test rig operating at 0.51-0.76 MPa (5-7.5 atm) with air preheated to 588 K (600°F). Five percent of the total fuel flow is injected through the centerbody tip as a diffusion pilot. The fuel composition is varied independently by blending approximately 5% (volume) propane with the pipeline natural gas. The reference velocity through the premixing annulus is kept constant for all conditions at a nominal value of 70 m/s. The fuel-air equivalence ratio is varied independently from 0.46 – 0.58. Relative to the DC field version, the time-varying combustion control and diagnostic sensor (TV-CCADS) shows a significant improvement in the correlation between the measured flame ionization current and local fuel-air equivalence ratio. In testing with different fuel compositions, the triangle wave data show the most distinct change in flame ionization current in response to an increase in propane content. Continued development of this sensor technology will improve the capability to control advanced gas turbine combustion systems, and help address issues associated with variations in fuel supplies.

03 NATURAL GAS↗