Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Silicon solar cell efficiency: Practice and promise

The maximum efficiency of silicon solar cells was calculated and yielded a value near 18%. Additionally, the performance of these high efficiency cells in a synchronous orbit radiation field was calculated and it is suggested that these cells would be superior to present silicon cells. The performance of conventional cells was analyzed and several areas in which performance gains may be achieved are discussed. These areas include improvements in diffused region profile, in reduction of excess forward currents in cells made from low resistivity material, and in the theory for describing complex solar cell structures.

Brandhorst, H. W., Jr.↗

A high temperature Rankine binary cycle for ground and space solar engine applications

A Rankine cycle covering the range of plasma temperatures possible from a solar radiation boiler is studied. The working fluid is potassium. A binary cycle with potassium as the topping cycle fluid and a conventional steam cycle as the bottoming cycle for earth-based applications is analyzed. Operation in conjunction with a wave energy exchanger is considered.

Hertzberg, A.↗

The role of convective model choice in calculating the climate impact of doubling CO2

The role of the parameterization of vertical convection in calculating the climate impact of doubling CO2 is assessed using both one-dimensional radiative-convective vertical models and in the latitude-dependent Hadley-baroclinic model of Lindzen and Farrell (1980). Both the conventional 6.5 K/km and the moist-adiabat adjustments are compared with a physically-based, cumulus-type parameterization. The model with parameterized cumulus convection has much less sensitivity than the 6.5 K/km adjustment model at low latitudes, a result that can be to some extent imitiated by the moist-adiabat adjustment model. However, when averaged over the globe, the use of the cumulus-type parameterization in a climate model reduces sensitivity only approximately 34% relative to models using 6.5 K/km convective adjustment. Interestingly, the use of the cumulus-type parameterization appears to eliminate the possibility of a runaway greenhouse.

Lindzen, R. S.↗

Preliminary evaluation of a liquid belt radiator for space applications

The liquid belt radiator (LBR) is discussed. The LBR system operates either in the sensible heat mode or in the latent heat mode. Parametric analysis shows that the LBR may reduce the mass of heat pipe radiators by 70 to 90% when the LBR surface has a total emissivity in excess of 0.3. It is indicated that the diffusion pump oils easily meet this criteria with emissivities greater than 0.8. Measurements on gallium indicate that its emissivity is probably in excess of 0.3 in the solid state when small amounts of impurities are on the surface. The point design exhibits a characteristic mass of 3.1 kg/kW of power dissipation, a mass per unit prime radiating area of approximately 0.9 kg/sq ms and a total package volume of approximately 2.50 cubic m. This compares favorably with conventional technologies which have weights on the order of 4 kg/sq m.

Teagan, W. P.↗

Some phenomena in space plasmas attributed to wave-particle interactions

Three different wave-particle interaction processes are investigated: (1) the pickup of newborn ions by the solar wind, (2) the cyclotron maser mechanism, and (3) a special wave-particle interaction process which generalizes the conventional concept of the wave-particle interaction process. It is demonstrated on the basis of these three cases that wave-particle interactions can play an indispendable role in certain physical phenomena associated with space plasmas, whose nature is such as to preclude conventional hydrodynamic characterization. Wave-particle interactions can also generate such anomalous transport processes as spatial diffusion, anomalous heating, absorptions of radiation, etc., which also have significant consequence in space plasmas.

Wu, Ching-Sheng↗

Interpretation of snow-climate feedback as produced by 17 general circulation models

Snow feedback is expected to amplify global warming caused by increasing concentrations of atmospheric greenhouse gases. The conventional explanation is that a warmer earth will have less snow cover, resulting in a darker planet that absorbs more solar radiation. An intercomparison of 17 general circulation models, for which perturbations of sea surface temperature were used as a surrogate climate change, suggests that this explanation is overly simplistic. The results instead indicate that additional amplification or moderation may be caused both by cloud interactions and longwave radiation. One measure of this net effect of snow feedback was found to differ markedly among the 17 climate models, ranging from weak negative feedback in some models to strong positive feedback in others.

Cess, R. D.↗

EMI Shields made from intercalated graphite composites

Electromagnetic interference (EMI) shielding typically makes up about twenty percent of the mass of a spacecraft power system. Graphite fiber/polymer composites have significantly lower densities and higher strengths than aluminum, the present material of choice for EMI shields, but they lack the electrical conductivity that enables acceptable shielding effectiveness. Bromine intercalated pitch-based graphite/epoxy composites have conductivities fifty times higher than conventional structural graphite fibers. Calculations are presented which indicate that EMI shields made from such composites can have sufficient shielding at less than 20% of the mass of conventional aluminum shields. EMI shields provide many functions other than EMI shielding including physical protection, thermal management, and shielding from ionizing radiation. Intercalated graphite composites perform well in these areas also. Mechanically, they have much higher specific strength and modulus than aluminum. They also have shorter half thicknesses for x-rays and gamma radiation than aluminum. Thermally, they distribute infra-red radiation by absorbing and re-radiating it rather than concentrating it by reflection as aluminum does. The prospects for intercalated graphite fiber/polymer composites for EMI shielding are encouraging.

Gaier, James R.↗

Parameterizing Grid-Averaged Longwave Fluxes for Inhomogeneous Marine Boundary Layer Clouds

This paper examines the relative impacts on grid-averaged longwave flux transmittance (emittance) for Marine Boundary Layer (MBL) cloud fields arising from horizontal variability of optical depth tau and cloud sides, First, using fields of Landsat-inferred tau and a Monte Carlo photon transport algorithm, it is demonstrated that mean all-sky transmittances for 3D variable MBL clouds can be computed accurately by the conventional method of linearly weighting clear and cloudy transmittances by their respective sky fractions. Then, the approximations of decoupling cloud and radiative properties and assuming independent columns are shown to be adequate for computation of mean flux transmittance. Since real clouds have nonzero geometric thicknesses, cloud fractions A'(sub c) presented to isotropic beams usually exceed the more familiar vertically projected cloud fractions A(sub c). It is shown, however, that when A(sub c)less than or equal to 0.9, biases for all-sky transmittance stemming from use of A(sub c) as opposed to A'(sub c) are roughly 2-5 times smaller than, and opposite in sign to, biases due to neglect of horizontal variability of tau. By neglecting variable tau, all-sky transmittances are underestimated often by more than 0.1 for A(sub c) near 0.75 and this translates into relative errors that can exceed 40% (corresponding errors for all-sky emittance are about 20% for most values of A(sub c). Thus, priority should be given to development of General Circulation Model (GCM) parameterizations that account for the effects of horizontal variations in unresolved tau, effects of cloud sides are of secondary importance. On this note, an efficient stochastic model for computing grid-averaged cloudy-sky flux transmittances is furnished that assumes that distributions of tau, for regions comparable in size to GCM grid cells, can be described adequately by gamma distribution functions. While the plane-parallel, homogeneous model underestimates cloud transmittance by about an order of magnitude when 3D variable cloud transmittances are less than or equal to 0.2 and by approx. 20% to 100% otherwise, the stochastic model reduces these biases often by more than 80%.

Barker, Howard W.↗

Tritium removal and separation technology developments

Recent increased interest from regulators and the public has led more organizations to consider the environmental impact and safety considerations of tritium handling. Examples include the significance of the tritium isotope separation system on ITER licensing, remediation of ground water from power utilities and government facilities and concerns of high tritium concentrations within operational CANDU reactors. GE Healthcare, formerly Amersham pic, has been producing tritium-labelled chemicals since the late 1940's. GE's manufacturing site located near Cardiff, UK has installed a tritium waste treatment and enrichment facility to radically reduce tritium discharges to the environment. This facility employs a continuous processing plant that recovers tritium from a complex mixture of tritiated organic and aqueous waste compounds. Two isotope separation techniques are used to achieve a final pure tritium product, which is used in the manufacturing of labelled compounds. Building upon this experience, together with Special Separations Applications Inc. (SSAI), GE has developed a large-scale diffusion-based isotope separation process as an alternative to conventional cryogenic distillation. Having a tritium inventory an order of magnitude lower than conventional cryogenic distillation, this process is attractive for heavy water detritiation, applicable to single and multi-unit CANDU reactors and research reactors as well as fusion applications. Additionally, the new process has advantages of being cryogen-free, less complex, simple to operate and having improved conventional and radiological safety. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Compact Superconducting RF Accelerators for Water Treatment

Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:

Vennekate, John↗

Nonisocentric Treatment Strategy for Breast Radiation Therapy: A Proof of Concept Study

Purpose: To propose a nonisocentric treatment strategy as a special form of station parameter optimized radiation therapy, to improve sparing of critical structures while preserving target coverage in breast radiation therapy. Methods and Materials: To minimize the volume of exposed lung and heart in breast irradiation, we propose a novel nonisocentric treatment scheme by strategically placing nonconverging beams with multiple isocenters. As its name suggests, the central axes of these beams do not intersect at a single isocenter as in conventional breast treatment planning. Rather, the isocenter locations and beam directions are carefully selected, in that each beam is only responsible for a certain subvolume of the target, so as to minimize the volume of irradiated normal tissue. When put together, the beams will provide an adequate coverage of the target and expose only a minimal amount of normal tissue to radiation. We apply the nonisocentric planning technique to 2 previously treated clinical cases (breast and chest wall). Results: The proposed nonisocentric technique substantially improved sparing of the ipsilateral lung. Compared with conventional isocentric plans using 2 tangential beams, the mean lung dose was reduced by 38% and 50% using the proposed technique, and the volume of the ipsilateral lung receiving ≥20 Gy was reduced by a factor of approximately 2 and 3 for the breast and chest wall cases, respectively. The improvement in lung sparing is even greater compared with volumetric modulated arc therapy. Conclusions: A nonisocentric implementation of station parameter optimized radiation therapy has been proposed for breast radiation therapy. The new treatment scheme overcomes the limitations of existing approaches and affords a useful tool for conformal breast radiation therapy, especially in cases with extreme chest wall curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertical gradient freeze growth of detector grade CdZnTeSe single crystals

Here, we report the growth of detector grade Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) single crystals, a recently discovered quaternary semiconductor for room temperature radiation detection, by a vertical gradient freeze (VGF) method. VGF is a comparatively low-temperature growth method and avoids relative motion between the heater and the ampoule containing the precursor materials which minimizes any thermal drift or temperature fluctuations. As a result, CZTS single crystals with superior charge transport properties has been obtained. Growth of detector-grade CZTS single crystals using VGF method has not been reported yet. X-ray spectroscopy based elemental analysis showed that the grown crystals demonstrated the desired stoichiometry required for high resolution radiation detection. Planar detectors fabricated by deposition of gold contacts (~0.07 cm 2 ) demonstrated high bulk resistivity ~10 10 Ω-cm and a very low leakage current density of 2.8 × 10 –8 A/cm 2 at a bias of 100 V when measured at room temperature. The detectors showed excellent radiation response with 100 % charge collection efficiency when exposed to 5486 keV alpha particles. The electron mobility-lifetime (μτ) product was measured to be 3 × 10 –3 cm 2 /V using a single polarity Hecht analysis which is at par with the recently reported values measured in CZTS grown using conventional Bridgman or travelling heater method. The electron mobility has been calculated to be 964 cm 2 V –1 s –1 using a time-of-flight (TOF) method, a substantial improvement over that obtained from conventionally grown CZTS single crystals.

36 MATERIALS SCIENCE↗

Low temperature process for diode termination of fully depleted high resistivity silicon radiation detectors that can be used for shallow entrance windows and thinned sensors

Fabrication of vertical diodes for radiation sensing using a low temperature microwave anneal is provided. This kind of anneal allows the back side processing to be performed after the front side processing is done without damaging the front side structures. This enables a simplified fabrication of thinned detectors compared to a conventional silicon on insulator process. Another feature that this technology enables is a thin entrance window for a detector that also serves as the doped diode termination. Such thin entrance windows are especially suitable for detection of low energy radiation.

Kenney, Christopher J.↗

European MSc Programs in Nuclear Sciences - To meet the Need of Stakeholders

A stakeholder needs assessment, carried out under the EU-EURAC and EU-ENEN II projects, clearly showed that, at the European level, there are a significant and constant need for post-graduates with skills in radiochemistry, radioecology, radiation dosimetry and environmental modelling and a smaller, but still important, demand for radiobiologists and bio-modellers. Most of these needs are from government organizations. If only the nuclear industry is considered, then the largest demand is for radiochemists and radiation protection dosimetrists. Given this spectrum of need and existing capacity in the areas of radiobiology it was concluded that the needs identified would be most efficiently met by three new degree programs: European MSc Radiation Protection European MSc Analytical Radiochemistry European MSc Radioecology. All three master programs would be developed using the framework provided by the Bologna Convention and the lecturing could be shared among specialist Scientists within a network of collaborating universities. Therefore, educational plans have been developed for the above MSc degrees. These plans envisage each degree comprising three modules that are common to all the degrees (3x10 ECTS credits), three specialist modules (3x10 ECTS credits) and a research project (1x60 ECTS credits). The courses should be aimed, not only to fill the identified European postgraduate education gap in radiological sciences, but also to provide a modular structure that is easily accessed by stakeholders for CPD training. It is anticipated that the European Masters will meet the academic training requirements of qualified 'experts', as defined by the European Commission and the IAEA. At the Norwegian University of Life Sciences (UMB) a pilot MSc in Radioecology has successfully been initiated in collaboration with UK and France.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of pelletron accelerator facility to study radiation effects on semiconductor devices

In this paper we present the comprehensive results on the effects of different radiation on the electrical characteristics of different semiconductor devices like Si BJT, n-channel MOSFETs, 50 GHz and 200 GHz silicon-germanium heterojunction bipolar transistor (SiGe HBTs). The total dose effects of different radiation are compared in the same total dose ranging from 100 krad to 100 Mrad. We show that the irradiation time needed to reach very high total dose can be reduced by using Pelletron accelerator facilities instead of conventional irradiation facilities.

36 MATERIALS SCIENCE↗

Hard x-ray nanofocusing using total-reflection zone plates

A total-reflection zone plate (TRZP), which is a reflective grating that generates a line focus of hard X-rays, was developed. Newly designed TRZPs, introducing a laminar grating concept, were fabricated with various zone parameters. The focusing performances with regard to the beam size and the diffraction efficiency were evaluated using synchrotron radiation X-rays of 10 keV energy. Although the beam sizes measured are insufficient in comparison with the ideal value, the maximum diffraction efficiency, measured at 20%, exceeds the limitations of conventional TRZPs based on a binary grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biological Treatment Planning for Tumor Therapy with Carbon Ions

Treatment planning for carbon ion therapy requires careful consideration and quantification of the biological effect of heavy ions. Since the radiation damage invoked by swift heavy particles considerably differs from that of photons, the relative biological effectiveness (RBE) must be taken into account to determine the relevant biologically equivalent dose. The RBE depends on many different parameters, such as the dose level, the ion species and energy as well as the biological endpoint. Currently, the Local Effect Model (LEM) developed at GSI is the only model that is used for treatment planning which takes these dependences into account. Here, we introduce the main ideas of the LEM and present its recent developments, which result in a better model accuracy when compared to experimental data. Further, we present the implementation of the LEM into the treatment planning software and discuss the potential advantages of carbon ions compared to conventional and proton irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiative interactions in multi-dimensional chemically reacting flows using Monte Carlo simulations

The Monte Carlo method (MCM) is applied to analyze radiative heat transfer in nongray gases. The nongray model employed is based on the statistical narrow band model with an exponential-tailed inverse intensity distribution. The amount and transfer of the emitted radiative energy in a finite volume element within a medium are considered in an exact manner. The spectral correlation between transmittances of two different segments of the same path in a medium makes the statistical relationship different from the conventional relationship, which only provides the non-correlated results for nongray methods is discussed. Validation of the Monte Carlo formulations is conducted by comparing results of this method of other solutions. In order to further establish the validity of the MCM, a relatively simple problem of radiative interactions in laminar parallel plate flows is considered. One-dimensional correlated Monte Carlo formulations are applied to investigate radiative heat transfer. The nongray Monte Carlo solutions are also obtained for the same problem and they also essentially match the available analytical solutions. the exact correlated and non-correlated Monte Carlo formulations are very complicated for multi-dimensional systems. However, by introducing the assumption of an infinitesimal volume element, the approximate correlated and non-correlated formulations are obtained which are much simpler than the exact formulations. Consideration of different problems and comparison of different solutions reveal that the approximate and exact correlated solutions agree very well, and so do the approximate and exact non-correlated solutions. However, the two non-correlated solutions have no physical meaning because they significantly differ from the correlated solutions. An accurate prediction of radiative heat transfer in any nongray and multi-dimensional system is possible by using the approximate correlated formulations. Radiative interactions are investigated in chemically reacting compressible flows of premixed hydrogen and air in an expanding nozzle. The governing equations are based on the fully elliptic Navier-Stokes equations. Chemical reaction mechanisms were described by a finite rate chemistry model. The correlated Monte Carlo method developed earlier was employed to simulate multi-dimensional radiative heat transfer. Results obtained demonstrate that radiative effects on the flowfield are minimal but radiative effects on the wall heat transfer are significant. Extensive parametric studies are conducted to investigate the effects of equivalence ratio, wall temperature, inlet flow temperature, and nozzle size on the radiative and conductive wall fluxes.

Liu, Jiwen↗