Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Problem areas in the use of the firefly luciferase assay for bacterial detection

By purifying the firefly luciferase extract and adding all necessary chemicals but ATP in excess, an assay for ATP was performed by measuring the amount of light produced when a sample containing soluble ATP is added to the luciferase reaction mixture. Instrumentation, applications, and basic characteristics of the luciferase assay are presented. Effect of the growth medium and length of time grown in this medium on ATP per viable E. coli values is shown in graphic form, along with an ATP concentration curve showing relative light units versus ATP injected. Reagent functions and concentration methods are explored. Efforts to develop a fast automatable system to detect the presence of bacteria in biological fluids, especially urine, resulted in the optimization of procedures for use with different types of samples.

Picciolo, G. L.↗

Formation of metallic and metallic-glass hollow spheres and their solidification characteristics

Various metals and metallic glass systems have bene processed into hollow spheres with sizes ranging from 3 mm to 440 microns in diameter. The technique for the formation of the large hollow spheres, in general, is based on the fluid-dynamic instability of a hollow annular jet. A refined technique has also been developed for microshell formation, in which discrete bubbles are injected into the stream of the molten material and individually 'flushed' out at a frequency related to the Rayleigh jet instability. The surfaces of those spheres of all sizes exhibit a range of contrasting solidification behaviors and characteristics. Metal shells of varying materials, sizes, aspect ratios, sphericity and concentricity have many useful and novel applications.

Lee, M. C.↗

Analytical and experimental investigations of the oblique detonation wave engine concept

Wave combustors, which include the Oblique Detonation Wave Engine (ODWE), are attractive propulsion concepts for hypersonic flight. These engines utilize oblique shock or detonation waves to rapidly mix, ignite, and combust the air-fuel mixture in thin zones in the combustion chamber. Benefits of these combustion systems include shorter and lighter engines which will require less cooling and can provide thrust at higher Mach numbers than conventional scramjets. The wave combustor's ability to operate at lower combustor inlet pressures may allow the vehicle to operate at lower dynamic pressures which could lessen the heating loads on the airframe. The research program at NASA-Ames includes analytical studies of the ODWE combustor using CFD codes which fully couple finite rate chemistry with fluid dynamics. In addition, experimental proof-of-concept studies are being carried out in an arc heated hypersonic wind tunnel. Several fuel injection designs were studied analytically and experimentally. In-stream strut fuel injectors were chosen to provide good mixing with minimal stagnation pressure losses. Measurements of flow field properties behind the oblique wave are compared to analytical predictions.

Menees, Gene P.↗

Review of the PDWA Concept for Combustion Enhancement in a Supersonic Air-Breathing Combustor Environment

This paper reviews the design of the Pulsed Detonation Wave Augmentor (PDWA) concept and the preliminary computational fluid dynamics studies that supported it. The PDWA relies on the rapid generation of detonation waves in a small tube, which are then injected into the supersonic stream of the main combustor. The blast waves thus generated are used to stimulate the mixing and combustion inside the main combustor. The mixing enhancement relies on various forms of the baroclinic interaction, where misaligned pressure and density gradients combine to produce vortical flow. By using unsteady shock waves, the concept also uses the Richtmyer-Meshkov effect to further increase the rate of mixing. By carefully designing the respective configurations of the combustor and the detonation tubes, one can also increase the penetration of the fuel into the supersonic air stream. The unsteady shocks produce lower stagnation pressure losses than steady shocks. Combustion enhancement can also be obtained through the transient shock-heating of the fuel-air interface, and the lowering of the ignition delay in these regions. The numerical simulations identify these processes, and show which configurations give the best results. Engineering considerations are also presented, and discuss the feasibility of the concept. Of primary importance are the enhancements in performance, the design simplicity, the minimization of the power, cost, and weight, and the methods to achieve very rapid cycling.

Canbier, Jean-Luc↗

Hydrogen/Air Fuel Nozzle Emissions Experiments

The use of hydrogen combustion for aircraft gas turbine engines provides significant opportunities to reduce harmful exhaust emissions. Hydrogen has many advantages (no CO2 production, high reaction rates, high heating value, and future availability), along with some disadvantages (high current cost of production and storage, high volume per BTU, and an unknown safety profile when in wide use). One of the primary reasons for switching to hydrogen is the elimination of CO2 emissions. Also, with hydrogen, design challenges such as fuel coking in the fuel nozzle and particulate emissions are no longer an issue. However, because it takes place at high temperatures, hydrogen-air combustion can still produce significant levels of NOx emissions. Much of the current research into conventional hydrocarbon-fueled aircraft gas turbine combustors is focused on NOx reduction methods. The Zero CO2 Emission Technology (ZCET) hydrogen combustion project will focus on meeting the Office of Aerospace Technology goal 2 within pillar one for Global Civil Aviation reducing the emissions of future aircraft by a factor of 3 within 10 years and by a factor of 5 within 25 years. Recent advances in hydrocarbon-based gas turbine combustion components have expanded the horizons for fuel nozzle development. Both new fluid designs and manufacturing technologies have led to the development of fuel nozzles that significantly reduce aircraft emissions. The goal of the ZCET program is to mesh the current technology of Lean Direct Injection and rocket injectors to provide quick mixing, low emissions, and high-performance fuel nozzle designs. An experimental program is planned to investigate the fuel nozzle concepts in a flametube test rig. Currently, a hydrogen system is being installed in cell 23 at NASA Glenn Research Center's Research Combustion Laboratory. Testing will be conducted on a variety of fuel nozzle concepts up to combustion pressures of 350 psia and inlet air temperatures of 1200 F. Computational fluid dynamics calculations, with the Glenn developed National Combustor Code, are being performed to optimize the fuel nozzle designs.

Smith, Timothy D.↗

An experimental and numerical study of wellbore leakage mitigation using pH-triggered polymer gelant

The potential leakage of hydrocarbon fluids or carbon dioxide from subsurface formations is a primary concern in wellbore integrity, oil and gas production, and CO 2 storage. Leaky wells with fractured cement or debonded microannuli are common sources of subsurface fluid leakage. The hydrocarbon fluid or CO 2 can migrate through such pathways to shallower formations and ultimately to surface. Cement fractures may have apertures on the order of microns, which are difficult to seal with typical workover techniques. A material that provides low viscosity during the injection but much higher viscosity after injection, with a minimum pressure gradient to yield flow at the target zone, is a potentially effective approach to seal the leakage pathways through cement fractures. pH-triggered polymers are such a material: aqueous solutions with low viscosity at low pH, containing pH-sensitive microgels which viscosify upon neutralization to become highly swollen gels with substantial yield stress that can block fluid flow. For the wellbore leakage application, the large alkalinity of wellbore cement provides the required neutralization. Our coreflood and rheological experiments show that pH-triggered polymer sealants such as polyacrylic acid polymer provide a robust seal if the process is properly designed; however, its long-term applicability depends on the dynamic geochemical environment of the wellbore. The process comprises three stages: (1) injection of a chelating agent as the preflush to ensure a favorable environment for the polymer gel, (2) injection of polymer solution, and (3) shut-in for the polymer gelation. A systematic study was done to understand the conditions under which the polymer gel remains stable and effectively seals the leakage pathways. A numerical model, based on polymer rheological properties and governing mechanisms observed in the laboratory experiments, was developed to simulate the reactive flow and transport of pH-triggered polymers in narrow fractures. Comparison with experiments shows a generally good agreement, despite the relative simplicity of the model. The numerical model was used to investigate further the underlying mechanisms of the process. The results can be used to design effectively the remediation process for a known fracture aperture size of the target zone.

42 ENGINEERING↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

15 GEOTHERMAL ENERGY↗

Modeling of Supersonic Film Cooling on the J-2X Nozzle Extension

Supersonic film cooling (SSFC) of nozzles has been used in several liquid rocket engine designs, and is being applied to the nozzle extension (NE) of the J-2X upper stage engine currently under development. Turbine exhaust gas (TEG) is injected tangentially from a manifold along the NE, and provides a thermal barrier from the core nozzle flow for the NE. As the TEG stream mixes with the nozzle flow, the effectiveness of the thermal barrier is reduced. This paper documents computational fluid dynamics (CFD) analysis work performed by NASA Marshall Space Flight Center (MSFC) to model the flow of the TEG through the manifold, into the nozzle, and the subsequent mixing of the TEG stream with the core flow. The geometry and grid of the TEG manifold, structural support ribs, and the NE wall will be shown, and the CFD boundary conditions described. The Loci-CHEM CFD code used in this work will also be briefly described. A unique approach to modeling the combined TEG manifold/thrust chamber assembly (TCA) was employed, as it was not practical to model the entire 360 circumferential range in one simulation. Prior CFD validation work modeling Calspan SSFC experiments in the early 1990s, documented in a previous AIAA paper, will also be briefly discussed. The fluid dynamics of the TEG flow through the manifold, into and between the structural support ribs, and into the nozzlette that feeds the TCA will be described. Significant swirl and non-uniformities are present, which along with the wakes from the ribs, act to degrade the film cooling effectiveness compared to idealized injection of TEG gas. The effect of these flow characteristics on the adiabatic wall temperature profile on the NE will be discussed.

Ruf, Joseph H.↗

Hybrid simulation of whistler excitation by electron beams in two-dimensional non-periodic domains

We present a two-dimensional hybrid fluid-PIC scheme for the simulation of whistler wave excitation by relativistic electron beams. This scheme includes a number of features which are novel to simulations of this type, including non-periodic boundary conditions and fresh particle injection. Results from our model suggest that non-periodicity of the simulation domain results in the development of fundamentally different wave characteristics than are observed in periodic domains.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Modified Meshgraphnets for Subsurface Prediction during CO2 Sequestration

In the face of the increasingly dire consequences of anthropogenic climate change, capturing and storing carbon dioxide is paramount. However, several impediments exist to the safe and effective subsurface storage of CO2, such as cost of transport, identification of suitable sites for subsurface storage, and assessment of long-term risk from storage in subsurface aquifers. Accurate subsurface modeling is necessary to ensure that CO2 storage is both safe and effective. Still, such modeling has traditionally required either substantial time and computational power (numerical simulation) or a substantial amount of pre-existing data for training (machine learning models). Additionally, these models lack flexibility in dealing with both changes in discretization of the input data and generalizability beyond the data on which they are trained. In order to address these issues, this research applies graph neural networks (GNNs) to predict subsurface saturation and pressure during CO₂ injection in a model of the Illinois Basin-Decatur Project (IBDP). GNNs provide a flexible, intuitive method for representing and manipulating complex unstructured data, which is often found in many practical domain problems such as fluid flow and subsurface characterization. These unstructured grids are easily represented in GNNs by representing spatially-localized features such as permeability, porosity, saturation, and pressure as nodes in a graph and relationships between these properties as edges connecting these nodes. This research applies a specific GNN model called MeshGraphNets (MGN) to model the change in CO2 saturation and pressure over a 50-month time period (36 months of injection, 14 months post-injection). The MGN model leverages a message passing process that allows the network to learn both the spatial and temporal dynamics of this system simultaneously. Additionally, training on a limited dataset (64 realizations, 20 time points each) resulted in a high degree of accuracy in saturation prediction both within the same timeframe as the training (20 months, 0.039 average RMSE) and when projecting out to the end of injection (36 months, 0.053 average RMSE). Temporal predictions such as those generated by MGNs and other similar models are prone to accumulated error over time; in order to address this, a multi-step rollout (MSR) training process was applied to calculate training loss. This method mimics the forward prediction during inference by “rolling out” multiple time points in a single training step using the previous prediction as input to the MGN model. By calculating the loss several time steps forward from the current prediction, the model is forced to find a more stable state over time. Application of MSR to the MGN model resulted in an average 15% reduction in inference error over time during forward prediction. This study showcases the immense potential of GNNs as a game-changing methodology for predicting pressure and saturation evolution in CCS projects, ultimately paving the way for more sustainable and effective carbon storage solutions. Presentation prepared for the 2024 AiChE Annual Meeting, October 27 to November 1 2024, San Diego, CA.

Holcomb, Paul↗

Behavior of Tidally Triggered Earthquakes Depends on Fluid Conditions

Seismicity at The Geysers geothermal field and in Oklahoma is heavily influenced by industrial activities related to energy production, though the mechanism in which earthquakes are induced or triggered is different. At The Geysers, much of the seismicity is linked to thermoelastic stresses caused by injecting cold water into hot rocks, whereas in Oklahoma, the seismicity is linked to a reduction of confining stress on faults due to increasing pore pressure resulting from wastewater injections. Here, in this study, we show that these contrasting conditions are also evident in tidally triggered earthquakes. At The Geysers, earthquakes preferentially occur during maximum extensional stress, which does not occur at the same time as maximum shear stress on optimally oriented faults in the regional stress field. In Oklahoma, earthquakes preferentially occur during maximum shear stress on optimally oriented faults rather than maximum extensional stress. The magnitude of tidal extensional stress is naturally much greater than tidal shear stress. However, in a fluid-saturated environment, pore pressure responds to changes in volume, which can counteract or reduce the effect of the applied stress. The difference in behavior at these two sites is indicative of the level of coupling between applied stress and pore pressure, corresponding to unsaturated conditions at The Geysers and high pore pressure in Oklahoma.

58 GEOSCIENCES↗

Gas injection to inhibit migration during an in situ heat treatment process

Methods of treating a subsurface formation are described herein. Methods for treating a subsurface treatment area in a formation may include introducing a fluid into the formation from a plurality of wells offset from a treatment area of an in situ heat treatment process to inhibit outward migration of formation fluid from the in situ heat treatment process.

Kuhlman, Myron Ira↗

Stability study of aqueous foams under high-temperature and high-pressure conditions relevant to Enhanced Geothermal Systems (EGS)

In Enhanced Geothermal System (EGS) hydraulic fracturing is carried out by injecting cold water into deep Hot Dry Rocks (HDR) under carefully controlled conditions to create new or reopen existing fractures. Water-based fracturing fluids demonstrate some challenges including immense quantity of water usage, water sensitivity of the formations, water blocking, and lack of proppant carrying capacity and transportation. Thus, an alternative is to use foam-based fracturing fluid which offers potential advantage over conventional water-based fracturing fluid such as minimum water usage, reduced wellbore damage, high proppant carrying capacity, and less environmental damage. However, foams are complex mixture of gaseous phase and liquid phase which are thermodynamically unstable at downhole conditions, and their stability can decrease over time due to liquid drainage, bubble coarsening, and coalescence. This paper shows laboratory experiments executed to study foam stability at high temperature (200°C) and high pressure (6.9MPa) conditions which simulates the geothermal environment. Foam stability was characterized by half-life of foam, which is defined as the time taken by the foam to decreases by 50% of its original height due to drainage. In this paper, two types of gaseous phases, nitrogen (N 2 ) and carbon dioxide (CO 2 ) were investigated. Also, based on successful practice of foam-based fracturing fluid in oil and gas industries, four surfactants, including Alpha olefin sulfonate (AOS), Sodium dodecyl sulfonate (SDS), Tergitol™ (NP – 40), and Cetyltrimethylammonium chloride (CTAC) at optimum concentration of 1wt.% were tested for best stability performance. In addition, different stabilizing agents including guar gum, bentonite clay, crosslinker, silicon dioxide nanoparticles (SiO 2 ), graphene oxide (GO) were also studied. Experimental results showed that N 2 foams were more stable than CO 2 foams. It was observed that foam half-life decreased with the increase in temperature. Among all the surfactants, AOS foams showed the most promising thermal stability at high temperatures. Moreover, with the addition of stabilizing agents, foam's half-life was enhanced. Stabilizing agents such as crosslinker and GO dispersion showed the most stable foams with half-life recorded at 20min and 17min, respectively, at 200°C and 6.9MPa. Finally, pressure also showed a positive effect on foam stability; with increased pressure, foam half-life was increased. Based on the experimental data, analytical models for the effect of temperature and pressure were developed, considering foam degradation is a first-order kinetic reaction that linearly depends on the foam drainage mechanism. The effect of temperature on foam half-life was studied as an exponential decay model. In this model, foam half-life is a function of drainage rate constant (D A ) and activation energy (E a ) of the foam system. The effect of pressure on foam half-life was found to obey a power-law model where an increase in pressure showed an increase in foam half-life. Furthermore, a linear relation was studied for the effect of pressure on foam activation energy and drainage rate. Then the combined effects of temperature and pressure were studied, which yielded an analytical model to predict the foam stabilities in terms of half-life for different foam compositions. In conclusion, this research indicates that with an appropriate selection of surfactants and stabilizing agents, it is possible to obtain stable foams, which could replace conventional water fracturing fluid under EGS conditions.

15 GEOTHERMAL ENERGY↗

Predict-first experiments and modeling of perturbative cold pulses in the DIII-D tokamak

Cold pulses are presented in Ohmic DIII-D tokamak plasmas via injection of impurities with a laser blow-off system, revealing for the first time in this machine a quick increase in core electron temperature shortly after the edge cold-pulse injection at low collisionality. The experimental results are consistent with predict-first simulations of heat transport enabled by the Trapped Gyro-Landau-Fluid transport model. Measurements of electron density evolution during the cold-pulse propagation are enabled by a high time resolution density profile reflectometer. The density evolution reveals the quick propagation of a pulse from edge to core, which is a mechanism to transiently increase core temperature in low-collisionality plasmas. Local transport simulations with measured density evolution demonstrate that the core temperature response can indeed be explained by the stabilization of Trapped Electron Mode turbulence at low collisionality, hence providing confidence that local transport modeling is enough to explain cold-pulse propagation and associated phenomenology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas density structure of supersonic flows impinged on by thin blades for laser-plasma accelerator targets

Density transition injection is an effective technique for controllably loading electrons into a trapped phase for laser plasma accelerators. One common technique to achieve the required fluid structure is to impinge a thin blade on the plume of a supersonic nozzle. Density transitions induced in this way are often assumed to be bow shocks and therefore sharp, but simulations and fluorescence measurements presented in this work show that in many cases of interest, the density transition accessible to a laser propagating transverse to the shock is an intercepting shock, and therefore, shock thickness and density vary with pressure, laser height, and blade position. The fluid dynamics of a supersonic nozzle impinged on by a thin, flat object are explored through simulations and relevant features are verified via planar laser-induced fluorescence measurements. Overall, the implications of the results for tuning electron beam injectors in laser plasma accelerators are discussed.

42 ENGINEERING↗