Search NASA⌕ Search

DOE OSTI · 3375159

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Abstract

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jian, Guoqing, Sarathi, Ramesh S., Burghardt, Jeffrey A., Petty, Susan, Garrison, Geoffrey, Gupta, Varun, Johnson, Timothy C., Huang, Lianjie, Liu, Jian, Cladouhos, Trenton, Appriou, Delphine, Martin, Paul F., White, Mark D., Pease, Leonard F., Zeng, Chao, Li, Zihao, Fernandez, Carlos A.. 2023-03-23. CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report). https://doi.org/10.2172/3375159

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗