Three-Dimensional Permeability of Thick-Section Glass Fabric Reinforced Polymer Composite by Vacuum-Assisted Resin Infusion Molding

Abstract Determination of permeability of thick-section glass fabric preforms with fabric layers of different architectures is critical for manufacturing large, thick composite structures with complex geometry, such as wind turbine blades. The thick-section reinforcement permeability is inherently three-dimensional and needs to be obtained for accurate composite processing modeling and analysis. Numerical simulation of the liquid stage of vacuum-assisted resin infusion molding (VARIM) is important to advance the composite manufacturing process and reduce processing-induced defects. In this research, the 3D permeability of thick-section E-glass fabric reinforcement preforms is determined, and the results are validated by a comparison between flow front progressions from experiments and from numerical simulations using ansys fluent software. The orientation of the principal permeability axes were unknown prior to experiments. The approach used in this research differs from those in literature in that the through-thickness permeability is determined as a function of flow front positions along the principal axes and the in-plane permeabilities and is not dependent on the inlet radius. The approach was tested on reinforcements with fabric architectures which vary through-the-thickness direction, such as those in a spar cap of a wind turbine blade. The computational simulations of the flow-front progression through-the-thickness were consistent with experimental observations.

Engineering↗

High-Fidelity Simulation Study of the Unsteady Flow Effects on High-Pressure Turbine Blade Performance

Abstract Unsteadiness, in the form of both broadband background disturbances and discrete coherent wakes, can have a strong effect on the performance of turbomachinery blades. The influence of the incoming flow has received much interest as it inevitably affects the blade boundary layers and develops as it passes through the machine. In the present work, we investigate the effect of unsteady flow on high-pressure turbines (HPTs), using high-fidelity datasets produced by wall resolved large-eddy simulation of an HPT stage. The effects of incident wakes from an upstream stator, compounded by the presence of freestream turbulence, on the downstream rotor are investigated. Based on analyzing cases with different turbulence intensities and length scales prescribed at the inlet, we show that changing the freestream turbulence characteristics has a direct effect on the unsteady behavior of the stator wakes. As a result, the performance of the rotor is also significantly affected. By detailing the influence of the wake–turbulence interaction, we aim to distinguish driving forces on rotor performance, be it changes in the incident wakes or direct influence from the freestream turbulence. Furthermore, the aerothermal behaviors of the rotor blades have been extensively investigated, showing that the blade boundary layers on the suction and pressure sides respond differently to external disturbances. The insights gained can provide designers with guidelines in understanding the unsteady flow effects of a given flow state, and how the unsteadiness present, either broadband or deterministic, will affect the performance of downstream blades.

Engineering↗

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tree-Based Ensemble Learning Models for Wall Temperature Predictions in Post-Critical Heat Flux Flow Regimes at Subcooled and Low-Quality Conditions

Accurately predicting post-critical heat flux (CHF) heat transfer is an important but challenging task in water-cooled reactor design and safety analysis. Although numerous heat transfer correlations have been developed to predict post-CHF heat transfer, these correlations are only applicable to relatively narrow ranges of flow conditions due to the complex physical nature of the post-CHF heat transfer regimes. In this paper, a large quantity of experimental data is collected and summarized from the literature for steady-state subcooled and low-quality film boiling regimes with water as the working fluid in vertical tubular test sections. In addition, a low-quality water film boiling (LWFB) database is consolidated with a total of 22,813 experimental data points, which cover a wide flow range of the system pressure from 0.1 to 9.0 MPa, mass flux from 25 to 2750 kg/m 2 s, and inlet subcooling from 1 to 70 °C. Two machine learning (ML) models, based on random forest (RF) and gradient boosted decision tree (GBDT), are trained and validated to predict wall temperatures in post-CHF flow regimes. The trained ML models demonstrate significantly improved accuracies compared to conventional empirical correlations. To further evaluate the performance of these two ML models from a statistical perspective, three criteria are investigated and three metrics are calculated to quantitatively assess the accuracy of these two ML models. For the full LWFB database, the root-mean-square errors between the measured and predicted wall temperatures by the GBDT and RF models are 5.7% and 6.2%, respectively, confirming the accuracy of the two ML models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of Correlations on the Thermal Performance Modeling of Parabolic Trough Collectors

The influence of correlations on the thermal performance modeling of parabolic trough collectors was analyzed in this work. A versatile model for a parabolic trough collector was developed that allows one- and two-dimensional analysis and enables the use of correlations to calculate thermophysical properties and convection heat transfer coefficients. The model also allows the use of constant values for properties and/or coefficients obtained from the evaluation correlations at a specific temperature. The effect of each correlation was evaluated independently, and the results were compared with a reference case that considered a two-dimensional approach and used all the correlations. For the analyzed cases, the correlation for the absorber emittance has the strongest impact on the collector efficiency, leading to a lower error when used. Based on the results, a one-dimensional model approach considering a correlation for the absorber emittance leads to efficiency errors below 3% for collector lengths of up to 243.6 m. Compared with the reference case, a one-dimensional approach using all correlations for a collector with a length of 500 m, and operating with an inlet temperature of 773 K, can result in errors around 9%. However, using constant values for properties and heat transfer coefficients could lead to errors of up to 50%. Multiple thermal models for parabolic trough collectors proposed in the literature rely on a one-dimensional approach, estimated values for the heat transfer coefficients, and constant thermophysical properties. The errors associated with those approaches are analyzed and quantified in this work as a function of the collector length and operation temperature.

absorber emittance↗

Manufacturing and Hydro Testing of a 10 MWe sCO2 Axial Turbine

Abstract Supercritical CO2 (sCO2) power cycles designed for thermodynamic efficiencies above 50% push component designs into pressure and temperature combinations that approach the limits of American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASME Piping Design Codes with Turbine inlet conditions near 250 bar and 715 °C. These design conditions which limit available materials to high nickel alloys are compounded by the high fluid densities of sCO2 at these conditions which result in very compact machinery at the 10 MWe class which are currently being developed for the DOE supercritical transformational electric power (STEP) program. Design of the STEP Turbine is complete with integrated lessons learned from a previous 1 MWth subscale demonstration of a high temperature 10 MWe Turbine designed under the DOE SunShot Program. Fabrication of the STEP Turbine is nearing completion with all housings and pressure containing components in hand. This paper provides a detailed look at design intentions and limitations for the pressurized sections of the main pressure casing and the fabrication of key turbine components. Additional discussion is provided regarding postfabrication inspection and acceptance of the casing for use after issues with casing welds were identified late in the fabrication process.

Engineering↗

Design and Cooling Performance of Additively Manufactured Ceramic Turbine Vanes

Ceramic materials are of significant interest in aviation and power generation gas turbine engines due to their low density and ability to withstand high temperatures. Increased cycle thermal efficiency and higher specific power output is possible by incorporating ceramic components that enable high turbine inlet temperatures and lower required cooling airflow levels. However, ceramics can be difficult and costly to form into the complex shapes used in gas turbine components, often requiring specialized multi-step processes. Furthermore, ceramic components in the hottest areas of a gas turbine, such as vanes or blade shroud seals, will still likely require cooling which is challenging to implement in conventional ceramic manufacturing approaches. Therefore, this study presents a multidisciplinary approach that investigates the design, fabrication, and overall cooling effectiveness evaluation of additively manufactured (AM), polymer derived ceramic (PDC) turbine vanes. A thermo-mechanically optimized vane design was generated, ceramic additive manufacturing of the complex cooling configuration was developed, and quantification of the increase in overall cooling effectiveness was performed in a 1X scale, high-speed facility using infrared thermography. This study produced a PDC AM process, capable of printing complex internal cooling schemes in 1X scale turbine vanes. Furthermore, it was found that the optimized vane more than doubled the overall cooling effectiveness observed in the baseline design, which reasonably agreed with thermomechanical optimization model predictions. Additionally, the optimized ceramic vane outperformed an identical metal vane, in terms of area averaged cooling effectiveness, suggesting that the ceramic vane could operate at reduced coolant flowrates to achieve comparable levels of cooling performance.

Reynolds number↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

An Experimental Investigation of Sintered Particle Effect on Heat Transfer Performance in an “Annular Flow” Evaporation Tube

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid and thin film evaporation, they can result in capillary evaporation and further enhance the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 µm sintered copper particles was added to the inner wall of a copper tube, aiming to form an “annular flow” and enhance the heat transfer characteristics by taking advantage of thin film and capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90 deg to 90 deg to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. In conclusion, results show that an “annular flow” formed by a thin layer of sintered particles can promote thin film and capillary evaporation and, therefore, boost the evaporation heat transfer coefficient.

42 ENGINEERING↗

System Design of a 2.0 MWth Sodium/Molten Salt Pilot System

Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. Although slightly higher limits may be possible with molten salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, HTF technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative to molten salts, such as with alkali metal systems. This investigation explores the development of a 2.0 MWth sodium receiver system that employs a sodium receiver as the HTF, as well as with a ternary chloride (20%NaCl/40%MgCl/40%KCl by mol wt.%) salt as a thermal energy storage (TES) medium to facilitate a 6-hr. storage duration. A sodium-to-salt heat exchanger model as well as a salt-to-sCO2 primary heat exchanger model are employed and evaluated in this investigation. A thermodynamic system design model was developed using Engineering Equation Solver (EES) where state properties were calculated at inlets and outlets along both hot and cold legs of the pilot-scale plant. This investigation assesses receiver performance as well as system efficiency studies for the pump and system operational ranges. Results found that high efficiency sodium receivers were found to have higher heat transfer coefficients and required far less spreading of incident flux. The system performance model results suggest that for a pump speed of 2400 RPM, respective hot and cold pump TDH values were determined to be 260.1–307 ft. and 260.1–307 ft for pump flow rates of 90–120 GPM.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Accumulator Sizing for the Hybrid Hydraulic Electric Architecture (HHEA) Using Dynamic Programming

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) is an approach to electrifying and improving that does not require very large electric machines. The majority power is provided hydraulically via a set of common pressure rails while small electric machines are used to modulate that power to meet exact demand. Each common pressure rail has an accumulator, which keeps the pressure of each rail near constant as long as the volume in the accumulator does not change much. A main pump adds or removes fluid from each accumulator as needed to reduce volume changes in the accumulators. It is the operation of this main pump which is investigated here. In previous analysis it was assumed that the size of the accumulators was large enough to account for any difference in fluid volume without significantly changing the pressure. In this paper, the required accumulator sizes are studied using a dynamic programming approach. At each time step the inlet and outlet of the main pump could be connected to any of the common pressure rails. These decisions for the main pump were optimized to minimize the required accumulator size. Case studies are conducted using drive cycles from a 22-ton excavator, a 20-ton wheel loader and a 5-ton excavator. The machines could be operated with total accumulator sizes of less than 20, 10, and 5 liters respectively. Required accumulator size was found to vary with pump flow rate, the frequency at which the pump/motor was able to change operating conditions, the tolerance level of pressure deviation and the accumulator’s polytropic index.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Response Surfaces for Key Controlled Variables in a Hybrid Solid Oxide Fuel Cell/Gas Turbine System

Hybrid generation systems have been extensively modeled as a first step toward the development of automatic controls for the system. In most cases, it is impossible to validate mathematical models against real hardware because only a handful of hardware systems exist in the world. Data taken from the existing hardware has demonstrated significant nonlinearity, complex coupling between controlled variables, and sometimes non-intuitive behavior. This work exploits the capability of the HyPer hardware test bed at the National Energy Technology Laboratory (NETL) to generate data from a real recuperated gas turbine coupled with hardware simulations of a fuel cell cathode and appropriate ancillary equipment. Prior work has characterized the system only over a limited range of its operating envelope, due to the inability to manipulate multiple control inputs simultaneously. The work presented here fills the gaps using data from a 34 factorial experiment to generate quasi-continuous response surfaces describing the operating state space of the HyPer system. Polynomial correlation functions have been fitted to the data with excellent agreement. Relationships between the control inputs and critical state variables such as cathode mass flow, cathode temperature, turbine inlet and exhaust temperatures and other key system parameters are presented.

30 DIRECT ENERGY CONVERSION↗

Characterization of a Solid Oxide Fuel Cell Gas Turbine Hybrid System Based on a Factorial Design of Experiments Using Hardware Simulation

A full factorial experimental design and a replicated fractional factorial design were carried out using the Hybrid Performance (HyPer) project facility installed at the National Energy Technology Laboratory (NETL), U.S. Department of Energy to simulate gasifer/fuel cell/turbine hybrid power systems. The HyPer facility uses hardware in the loop (HIL) technology that couples a modified recuperated gas turbine cycle with hardware driven by a solid oxide fuel cell model. A 34 full factorial design (FFD) was selected to study the effects of four factors: cold-air, hot-air, bleed-air bypass valves, and the electric load on different parameters such as cathode and turbine inlet temperatures, pressure and mass flow. The results obtained, compared with former results where the experiments were made using one-factor-at-a-time (OFAT), show that no strong interactions between the factors are present in the different parameters of the system. This work also presents a fractional factorial design (ffd) 34-2 in order to analyze replication of the experiments. In addition, a new envelope is described based on the results of the design of experiments (DoE), compared with OFAT experiments, and analyzed in an off-design integrated fuel cell/gas turbine framework. This paper describes the methodology, strategy, and results of these experiments that bring new knowledge concerning the operating state space for this kind of power generation system.

30 DIRECT ENERGY CONVERSION↗

Predicting EBC Temperature Limits for Industrial Gas Turbines

Higher turbine inlet temperatures may require the use of ceramic matrix composites (CMC) such as SiC/SIC, which require environmental barrier coatings (EBCs) to protect them against the detrimental effect of water vapor. Here, the goal of this project is to determine the maximum bond coating temperature for EBCs for land-based turbines, where the minimum coating lifetime is 25,000 h. If the temperature exceeds the 1414°C melting point of the Si bond coating, then coatings without a bond coating also need to be evaluated. Thus, current Yb 2 Si 2 O 7 EBCs with a Si bond coating and next-generation EBCs without a Si bond coating are being evaluated in laboratory testing using 1-h cycles in air+90%H 2 O. For this initial work, coatings were deposited on CVD SiC coupons. Reaction kinetics at 1250°, 1300° and 1350°C have been evaluated by measuring the thickness of the thermally grown silica scale after 100–500 h exposures. For comparison, scale growth rates for uncoated SiC and Si specimens in dry and wet environments were included as minimum and maximum values, respectively. Based on a critical scale thickness failure criteria, estimated maximum temperatures were calculated for both EBC systems using this initial data.

42 ENGINEERING↗

Development of a 300 MWe Utility Scale Oxy-Fuel sCO2 Turbine

A 300 MWe direct-fired supercritical carbon dioxide (sCO2) oxy-fuel turbine is being developed that will burn natural gas-fired, coal syngas and even hydrogen mixtures capable of 1,150ºC turbine inlet temperature at 300 bar. This design will significantly improve the state-of-the-art for thermal efficiency and results in a high-pressure stream of CO2 with 98%+ carbon capture, making the power plant near emission-free and more efficient than Natural Gas Combined Cycle (NGCC) plants with carbon capture. This power plant will be capable of burning coal through gasification and cleanup of the synthesis gas (syngas). sCO2 power cycles are a transformational technology for the energy industry, providing higher efficiency heat source energy conversion for conventional and alternative energy sources. This novel cycle significantly reduces capital costs because of smaller equipment footprints, design modularity, and allows for rapid cyclic load and source following to balance solar and wind energy power swings. Oxy-fuel sCO2 cycles take these advantages even further, utilizing higher firing temperatures, improved efficiency, and simpler carbon capture strategies. This turbine will require cooled turbine nozzles and blades as well as advanced thermal management systems to accommodate these high temperatures. The cooled blade heat transfer correlations required new test programs at higher Reynolds number than air-breathing gas turbines for impingement, serpentine, and pin-fin regions. Novel blade optimization was performed to maximize aerodynamic efficiency, while minimizing cooling flows. A turbine layout was generated utilizing individual combustor cans with cooled liners feeding into a 6-stage axial flow turbine with cooled stator nozzles and turbine blades. The case design and thermal management preliminary design will be described.

Moore, Jeffrey↗

Design and Cooling Performance of Additively Manufactured Ceramic Turbine Vanes

Ceramic materials are of significant interest in aviation and power generation gas turbine engines due to their low density and ability to withstand high temperatures. Increased cycle thermal efficiency and higher specific power output is possible by incorporating ceramic components that enable high turbine inlet temperatures and lower required cooling airflow levels. However, ceramics can be difficult and costly to form into the complex shapes used in gas turbine components, often requiring specialized multi-step processes. Furthermore, ceramic components in the hottest areas of a gas turbine, such as vanes or blade shroud seals, will still likely require cooling which is challenging to implement in conventional ceramic manufacturing approaches. Therefore, this study presents a multidisciplinary approach that investigates the design, fabrication and overall cooling effectiveness evaluation of additively manufactured (AM), polymer derived ceramic (PDC) turbine vanes. A thermo-mechanically optimized vane design was generated, ceramic additive manufacturing of the complex cooling configuration was developed, and quantification of the increase in overall cooling effectiveness was performed in a 1X scale, high-speed facility using infrared thermography. This study produced a PDC AM process, capable of printing complex internal cooling schemes in 1X scale turbine vanes. It was found that the optimized vane more than doubled the overall cooling effectiveness observed in the baseline design, which reasonably agreed with thermomechanical optimization model predictions. Additionally, the optimized ceramic vane outperformed an identical metal vane, in terms of area averaged cooling effectiveness, suggesting that the ceramic vane could operate at reduced coolant flow rates to achieve comparable levels of cooling performance.

Fox, Andrew↗

Partially cracked ammonia mixture combustion in gas turbine combustors

Ammonia is gaining popularity for single fuel use in existing gas turbines, as it is carbonless, has higher hydrogen content per unit volume than liquid hydrogen, and facilitates easy storage and handling. However, the low flame speed of ammonia makes it prone to flame blow off and remains the chief concern for its use in power generation. Following previous studies that have shown improved combustion performance by partially cracking the fuel, in this computational study, efficacy of partially cracked ammonia as a replacement fuel for natural gas is evaluated. A high-pressure optically accessible combustor operated at ~10 bar pressure with non-vitiated heated air was used as the test platform. This combustor was equipped with a novel multifuel multi-tube micromixing injector (M3 injector). High resolution simulations of the flow fields both in the injector as well as the combustor were performed to understand the fuel mixing in the injector and in the inlet region of the combustor. These modeling results showed that the injector was highly effective for achieving mixture homogeneity at the entrance of the combustor for ammonia and natural gas injection, whereas, for hydrogen an earlier injection facilitating longer residence time would be beneficial. Also, these simulations show that while harnessing waste heat the ideal fuel dissociation fraction is between 0.4 and 0.55 for optimal operation.

Ammonia↗