Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Lasers for Medicine Final Report CRADA No. TC-0436-93

This project is intended to advance the US position in laser diae~osis and treatment of disease in three thrust areas. A first laser system will advance the US position in photodynamic therapy whereby dyes are introduced into selected tissue and laser treatment with wavelena@ matching the dyes’ absorption band allows treatment of only the desired tissue. This effort will focus on the development and application of diode arrays delivering up to 10 watts at wavelengths of 657 nm, 675 nm and 695 nm with fiber optic delivery systems. This system would replace existing cumbersome systems with a compact diode array system. A second laser system is intended to advance the US position in the medical use of lasers in dermatology to remove port wine stains. The project will involve the development of a new all solid-state laser system to deliver light at 585 nm for the d~ect removal of port wine stains in human skin. This solid-state system would replace the currently used dye laser system with a compact, more efficient, less costly, environmentally benign solid-state laser system. Additionally this new laser system will offer new flexibility in the pulse format allowing treatment on a wider range of patients. A third laser system is targeted to develop a diode-pumped TrnYAG laser system operating at 1.9 pm to drill small holes in animal eggs with the goal of improving fertility. This system would replace the current excimer system at 308 nm, which has undesirable mutagenic problems

42 ENGINEERING↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and evaluation of the conceptual design for a liquid radiological waste system in an advanced hybrid control room

As the current fleet of nuclear power plants are maintaining outdated or obsolete equipment it is common practice to replace worn-out equipment on an as-needed basis resulting in a series of like-for-like replacements of components on the control boards addressing an immediate need to replace equipment. Such upgrades rarely represent an encompassing or systematic vision for control room modernization and do not add the additional benefit of enhanced support for operators in the control room, which tend to overlook the opportunity to reduce operations and maintenance costs through enhanced efficiency. The purpose of the research is to provide guidance on how to realize these opportunities by designing control room human-system interfaces with advanced capabilities in mind. Further, the research seeks to ensure that control room modernizations are undertaken with a sound understanding of the impacts to human operators and are designed based on state-of-the art human factors principles. This report describes the conceptual design of the liquid radiological waste system and several research activities conducted to inform the design philosophy. The report also provides recommended updates to the original design philosophy (published by the researchers in 2018) based on the findings.

99 GENERAL AND MISCELLANEOUS↗

Durability of Corrosion Protection Coatings for Aluminum

The objectives of this work are to (1) Develop a detailed understanding of the performance characteristics of current chromate conversion coatings utilized in the stockpile, (2) Develop a detailed understanding of the performance characteristics of non-chromate conversion coatings proposed to replace their chromate containing counterparts, (3) Provide an informed assessment of the aforementioned coatings and a recommended course of action for the replacement of chromate containing coatings, and (4) establish subject matter expertise in the area of replacement coatings to provide as a resource to the systems organization. These tasks will be accomplished by performing a battery of traditional corrosion performance tests (in accordance with the relevant MIL specifications governing chemical conversion coatings), combined with more detailed analytical evaluation of the materials. Coatings will be evaluated in the as-received and artificially aged condition. Four different coating systems were evaluated on four different aluminum alloys in FY16. The focus this year was to continue populating the test matrix initiated in previous years, evaluating key coatings in the as received and thermally stressed condition, as compared to the baseline chromate conversion coating (Bonderite (formerly Alodine) 1200S). The non-chromate conversion coatings included Bonderite T 5900, Chemeon TCP-HF, Luster-On Aluminescent, and MacDermid-Enthone Iridite NCP. A second effort that was completed this year was to address a bottleneck that existed for the electrical evaluation of the coatings, assessing their conformance with the MIL specification. An electromechanical test system was assembled and automated, eliminating the need to rely on an already heavily utilized mechanical test system and operator in Materials Mechanics and Tribology.

36 MATERIALS SCIENCE↗

BOM: The Next Generation of High Performance Explosives

The EPA has declared phase-out of Trinitrotoluene (TNT) a priority due to toxicity concerns. LANL and the Army Research Laboratory created a melt-castable next generation high performance explosive to replace TNT. They invented bis(1,2,4-oxadiazole)bis(methylene) dinitrate, or BOM, a higher-performing, safer replacement, which is 50% more energetic than TNT. BOM is less toxic to produce and use than TNT. Unlike competitors, BOM requires no performance-enhancing additives. BOM could replace TNT in a variety of civilian and military applications. BOM has been synthesized at the multi-kilogram scale.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Case Study: Integrate Nuclear Water Desalination - Regional Potable Water in Arizona

The present study analyzes the economic viability of an Integrated Energy System (IES) that couples a Reverse Osmosis (RO) water desalination facility with a Nuclear Power Plant (NPP). The case study is conducted in collaboration with Arizona Public Service (APS), the operating owner of the Palo Verde Generating Station (PVGS) NPP. Cooling water for the reactor steam cycle is derived from treated effluent from municipal wastewater treatment plants. APS has established a long-term water resources program to effect a substantial reduction in plant cooling costs through advanced treatment and cooling technologies, and through the use of alternative water sources to replace the increasingly expensive effluent. One possible option is to replace some amount of the annual volume of effluent with brackish groundwater from a local regional aquifer. Although much less expensive than the municipal effluent, the quantity of brackish groundwater that could be used for plant cooling is limited as a result of the salinity and its impact on plant operation. Consequently, supplemental treatment could be required such that a greater amount of brackish groundwater could be used to reduce the demand on effluent. A study was conducted in 2018 by Idaho National Laboratory (INL) to investigate the economics of a PVGS onsite RO desalination plant that would reduce the salinity of a municipal effluent and brackish water blend to an acceptable level. One of the main findings of that study was that the overall economics of water desalination can be greatly improved if, in addition to cooling water for PVGS, potable water could also be produced and sold for profit. In fact, the study concluded that only producing cooling water for PVGS via RO desalination is not economically viable. The present report investigates the economic impact of a large, regional RO desalination plant that could provide potable water for the region, considering the conclusions from the 2018 scoping study. The study looks in particular at the water-market situation for the developing municipalities in the west valley of Phoenix. In addition to providing potable water for the municipalities, the existing infrastructure that conveys effluent to the Palo Verde plant and onsite water treatment facilities could be used to manage the RO concentrate. The processed concentrate could lead to a cost reduction in plant cooling by replacing some amount of effluent. The analysis reported here considers two cases (for various scenarios). First, the Base Case considers that neither the regional nor the onsite RO is built. The 2018 INL study showed that some brackish water can be blended with the municipal effluent water without having to build the onsite RO. That correspond to the maximum economically profitable option. The Base Case is where APS pumps the maximum volume of less-expensive brackish water (limited by water chemistry in the circulating water system), i.e. the case for which cooling water acquisition and treatment cost are lowest (without RO). Second, the proposed RO Case includes two RO plants, one onsite at PVGS and another larger, regional RO plant close to the brackish water wells. The regional RO produces potable water that is sold to the regional municipalities, while the PVGS onsite RO treats (part of) the regional ROs' concentrate and brackish water blend. The desalinated water from the PVGS RO is used in the circulating water system at PVGS. The analysis evaluates the difference in economics, using the Net Present Value (NPV) and Internal Rate of Return (IRR), between the cases. By comparing the two cases, in addition to evaluating the economics of the regional RO, we can also assess the impact of the regional RO on PVGS operational costs and, consequently, APS economics. The study shows that there exist combinations of regional RO and PVGS RO sizes for which the total blowdown and water chemistry limits at PVGS (including regional RO concentrate treatment at PVGS) are satisfied. However, such combinations only exist if no additional brackish water is directly mixed in the tertiary water system at PVGS. This leads to higher Levelized Costs of Potable Water (LCOPW) compared to cases where additional brackish water is injected (but violate the physical constraints). Additional studies are suggested to investigate the benefit of additional brackish water injection (lowers cooling water cost) versus the cost of lifting the physical constraints, e.g. building additional evaporation ponds. Staying in the case of no additional brackish water and satisfying the existing PVGS constraints, the lowest LCOPW (~0.5 $/m 3 ) can be achieved with a size of the regional RO of ~1.4e7 m 3 /yr (11000 AF/yr) capacity, which leads to ~8.63e6 m 3 /yr (7000 AF/yr) of potable water while no onsite RO at PVGS is built. Considering the vii residential water demand model developed for the Phoenix west valley, the NPV for this regional RO would be ~$100 million if all municipalities in the vicinity participate from the beginning of the project.

97 MATHEMATICS AND COMPUTING↗

History of Ethanol Fuel Adoption in the United States: Policy, Economics, and Logistics

Ethanol has the achieved the greatest market share of all the alternative transportation fuels that have been researched, developed, and deployed in the US. There are multiple lessons to be learned from the history of ethanol adoption that can be applied to future fuels and products. Ethanol has replaced portions of gasoline in three main blend levels, with corresponding vehicles, equipment, benefits, and policies. The first is E10, which has replaced nearly all pure gasoline (E0) sold in the United States today (U.S. Energy Information Administration 2015). This was brought about through generations of policies that were motivated by multiple factors related to engine performance, energy security, health, air quality, and climate protection. Ethanol's high octane has been a consistent driver of the fuel because this enables higher performance engines. Early policies (1973-1979) were largely motivated by the desire to reduce dependence on petroleum sourced from members of the Organization of the Petroleum Exporting Countries, or OPEC. Fuel policy in the 1980s was largely in pursuit of promoting octane number enhancers that could replace lead. Criteria pollutant reduction was the overarching goal of actions taken from 1990 to 2005. From 2005 to the present, fuel policy has been largely motivated by energy security and climate protection goals. These policies were usually technology-agnostic and promoted multiple fuels and additives during each period. However, ethanol is the only fuel identified that is cost effective with qualities that enabled it to prosper in the policy environments of all four of these periods.The second market for ethanol is via 85% ethanol (E85). This fuel has the advantage of a greater concentration of ethanol but the disadvantage of not being compatible with regular gasoline vehicles. Instead, it can only be used in flexible-fuel vehicle (FFVs), which can use every blend level from E0 to E85. Therefore, much of the effort to increase E85 consumption has been aimed at incentivizing automakers to manufacture FFVs, drivers to purchase FFVs, and fueling stations to equip themselves to sell E85.The third, and newest, market through which ethanol is consumed is 15% ethanol (E15), which builds upon the E10 market to increase ethanol consumption by common gasoline vehicles. Efforts to create the E15 market consisted largely of testing vehicles and refueling equipment for compatibility, creating waivers to allow the use of E15, placing requirements on E15 retailers, and incentivizing retailers to equip themselves to purchase E15.

09 BIOMASS FUELS↗

A Cost-Effective Upgrade Path for the Fermilab Accelerator Complex

The Fermilab Proton Improvement Plan II, or PIP-II, would enable the world's most intense high-energy neutrino beam and would help scientists search for rare particle physics processes. The PIP-II goal is to deliver 1.2 MW of proton beam power from the Fermilab Main Injector, over the energy range 60 - 120 GeV, at the start of operation of the LBNF/DUNE program. PIP-II provides a variety of upgrade paths to higher beam power from the Main Injector, as demanded by the neutrino science program and as recommended by the 2014 P5 report. Delivering more than 2 MW to the LBNF target in the future will require a replacement of the existing Booster. This report outlines a cost-effective Booster replacement option and an upgrade path for the Fermilab Accelerator Complex to attain 2.4-MW beam power on the LBNF target, as well as to retain the capability to provide 8-GeV proton beams to the existing Fermilab Muon Campus via the existing Recycler ring. Its cost-effectiveness is achieved by: (1) using a small-diameter metallic vacuum chamber in the Booster replacement and (2) reusing the existing Recycler ring. Reusing the Recycler ring may be of particular advantage since it is presently employed to deliver 8-GeV beams to the Muon Campus experiments. The present concept also retains such a capability.

43 PARTICLE ACCELERATORS↗

LANL Meteorological Program: 2020 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates four mesa-top meteorology towers: Technical Area (TA) 06, TA-49, TA-53, and TA-54. An additional tower is located in Mortandad Canyon (TA-5 MDCN), and a rain gauge at North Community (NCOM). A description of the meteorology monitoring network is found in Dewart and Boggs (2014). Mesa-top towers are instrumented at 1.2 meters (m), 11.5 m, 23 m, and 46 m. In addition, TA-06 is instrumented at 92 m. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected every 15 minutes. Range checking is done on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by meteorologists to identify bad data not identified by range checking. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement as required. Data completeness is determined by the number of total 15-minute records available versus the total number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, containing bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Investigating Benefits and Challenges of Converting Retiring Coal Plants into Nuclear Plants

A coal-to-nuclear (C2N) transition means siting a nuclear reactor at the site of a recently retired coal power plant. Three overarching questions from the C2N transition guide this research: where in the United States are retired coal facilities located and what factors make a site feasible for transition; what factors of technology, cost, and project timeline drive investor economics over such a decision; and how will C2N impact local communities? The study team evaluated the siting characteristics of recently retired plants and those operating coal-fired power plant sites run by a utility or an independent power producer utilizing publicly available data to screen U.S. coal power plant sites to nuclear-feasible locations. After screening all retired coal sites to a set of 157 potential candidates and screening operating sites to a set of 237 candidates, the study team estimates that 80% of retired and operating coal power plant sites that were evaluated have the basic characteristics needed to be considered amenable to host an advanced nuclear reactor. For the recently retired plant sites evaluated, this represents a capacity potential of 64.8 GWe to be backfit at 125 sites. For the operating plant sites evaluated, this represents a capacity potential of 198.5 GWe to be backfit at 190 sites. This report evaluates a case study for the detailed impacts and potential outcomes from a C2N transition. Based on the nuclear technology choices and sizes evaluated to replace a large coal plant of 1,200 MWe generation capacity at the case study site, nuclear overnight costs of capital could decrease by 15% to 35% when compared to a greenfield construction project, through the reuse of infrastructure from the coal facility. Nuclear replacement designs can have a lower capacity size because nuclear power plants run at higher capacity factors than coal power plants. In the case study replacing coal capacity with 924 GWe of nuclear capacity, the study team found regional economic activity could increase by as much as $\$275 million$ and add 650 new, permanent jobs to the region of analysis. The evaluated site choice in the report is hypothetical for analysis purposes only and based on available data and documented assumptions. Consequently, the findings only inform at a general level. A community, investor, or other interested stakeholder can use these results to set up a detailed, in-depth analysis for a specific application of interest, such as evaluating a C2N transition of a specific coal power plant and a specific nuclear technology design. The report was subjected to independent peer reviews by experts in systems engineering and regional economic modeling to evaluate analysis and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗

Stochastic Price Generation for Evaluating Wholesale Electricity Market Bidding Strategies

This work presents a novel method for generating electricity price scenarios from statistical properties of past electricity prices using a hybrid statistical and reduced-form stochastic model. Previous work in applying stochastic differential equations (SDE) to model electricity prices has focused on daily average prices. To extend stochastic price generation methods to hourly or sub-hourly pricing, we address several weaknesses in the state-of-the-art: (1) we replace the mean-reversion component of the SDE with an ARIMA process that is better able to characterize the daily and weekly trends; (2) we extend the price-spike, or jump process to account for conditional probabilities of price spikes occurring in consecutive time steps by replacing the traditional Poisson process for modeling jumps with a generalized point process model inspired by brain neuron models; and (3) we replace the traditional method of estimating spike intensity with empirical variance with a Markov process based on observed price spike intensity transitions. The method is demonstrated with electricity prices from the US ERCOT market and a use-case example is provided for bidding an energy storage unit into the day-ahead and real-time energy markets of ERCOT using stochastic optimization methods. Results show that the the synthetic price model out performs a (naive) persistence forecast model by resulting in 24% to 47% more in profits over 168 simulated days.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LANL Meteorological Program: 2022 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA- 54B, and TA-16B were installed in 2021, and will be included in the 2023 data completeness/quality report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗

Comparison of the Neutronic Performance of IRP-1 and IRP-2 at SNS

The Spallation Neutron Source (SNS) operated from start-up, in May 2006, through December, 2017 before replacing the Inner Reflector Plug (IRP). This component is the most costly and time-consuming “regular maintenance” replacement foreseen in the operation of the First Target Station (FTS). The IRP includes beryllium reflector blocks, steel and aluminum support structures, aluminum moderator vessels (which in turn include gadolinium and cadmium neutron poisons) and water coolant systems. The lifetime of this multi-million dollar component is driven by poison and decoupler burnup in moderator vessels. The moderators include these neutron poisons to best match neutron beam performance with scattering instrument needs. The burnup that comes with use changes the performance of the moderators until they no longer server their intended purpose. The reasonable desire to maximize the IRP lifetime means that the moderator performance at the Beginning Of Life (BOL) is significantly “over poisoned” and different from the performance at moderator End Of Life (EOL). Upon installation of the second IRP article, IRP-2, the SNS Neutronics team characterized the performance of the neutron beamlines in order to assess the differences between them, primarily by comparing the EOL performance of IRP-1 to the BOL performance of IRP-2. While IRP-2 was largely similar to IRP-1 in its conceptual design, there were some differences in the specific design of IRP-2 to support enhanced manufacturability, and the change from IPR-1 to IRP-2 coincided with the replacement of the light water in the IRP cooling loop with heavy water, as had been intended in the SNS design but not implemented during construction because of heavy water availability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modernizing Fermilab s Control Hardware

Modernizing the Fermilab accelerator control system is essential to future operations of the laboratory's accelerator complex. The existing control system has evolved over four decades and uses hardware that is no longer available. The Accelerator Controls Operations Research Network (ACORN) Project will modernize the control system and replace end-of-life power supplies to enable future accelerator complex operations with megawatt particle beams. The ACORN project is planning to replace Fermilab’s obsolete CAMAC crate-and-card controls hardware with modern MicroTCA hardware. There are over 2,000 CAMAC cards and over 250 CAMAC crates serving various functions in Fermilab’s control system. We will present an overview of the existing CAMAC hardware and the proposed MicroTCA replacement plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASSESSMENT OF HIGH-VOLUME HARVESTED FLY ASH BLENDS FOR USE IN PRECAST CONSTRUCTION

Declining supplies of fresh fly ashes in some regions have further driven the importance of using harvested fly ash as a supplementary cementitious material and thus replacement for more energy-intensive ordinary Portland cement (OPC). Higher replacement rates of OPC with fly ash in general has traditionally been limited in precast operations due to stringent early-age strength requirements necessitated by initial prestress and lifting/handling of hardened components – often well within 24 hours after fresh concrete placement. Therefore, a series of mix designs were developed, as part of a larger framework for reassessing high-volume fly ash (HVFA) use in the context of precast construction, to demonstrate the feasibility of using larger fractions of harvested fly ash in concrete formulations suitable for precast fabrication demands. More specifically, a target minimum 24-hour compressive strength of 24.1 MPa (3500 psi) was set, in accordance with conventional precast structural design checks, while increasing the fly ash content to 40% replacement of OPC – at least a 15% increase above the traditional limit of 25%. The effect of using more sustainable Type IL cement in contrast to conventional Type III Portland cement (the traditional standard for precast use) – both in conjunction with HVFA use – was also examined. Early-age mechanical properties including compressive strength, modulus of rupture, and modulus of elasticity were evaluated within the aforementioned early-age window. Lastly, corresponding design equations were then reassessed for their applicability with respect to the high-early strength HVFA mixes examined herein.

Gombeda, Matthew J.↗

LANL Meteorological Program: 2023 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA-54B, and TA-16B have been in testing since they were installed in 2021, and will be included in a future data completeness report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗