Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arms Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SAVANNAH RIVER SITE TANK 18 AND TANK 19 WALL SAMPLER PERFORMANCE

A sampling tool was required to evaluate residual activity ({mu}Curies per square foot) on the inner wall surfaces of underground nuclear waste storage tanks. The tool was required to collect a small sample from the 3/8 inch thick tank walls. This paper documents the design, testing, and deployment of the remotely operated sampling device. The sampler provides material from a known surface area to estimate the overall surface contamination in the tank prior to closure. The sampler consisted of a sampler and mast assembly mast assembly, control system, and the sampler, or end effector, which is defined as the operating component of a robotic arm. The mast assembly consisted of a vertical 30 feet long, 3 inch by 3 inch, vertical steel mast and a cantilevered arm hinged at the bottom of the mast and lowered by cable to align the attached sampler to the wall. The sampler and mast assembly were raised and lowered through an opening in the tank tops, called a riser. The sampler is constructed of a mounting plate, a drill, springs to provide a drive force to the drill, a removable sampler head to collect the sample, a vacuum pump to draw the sample from the drill to a filter, and controls to operate the system. Once the sampler was positioned near the wall, electromagnets attached it to the wall, and the control system was operated to turn on the drill and vacuum to remove and collect a sample from the wall. Samples were collected on filters in removable sampler heads, which were readily transported for further laboratory testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Midlatitude Oceanic Cloud and Precipitation Properties as Sampled By the ARM Eastern North Atlantic Observatory

Marine low clouds are critical to the climate system because of their extensive coverage and associated controls on boundary layer dynamics and radiative energy balance. The primary foci for this study are marine low cloud observations over a heavily instrumented site on the Azores archipelago in the eastern North Atlantic (ENA) and their associated raindrop size distribution (DSD) properties, relative low-cloud contributions to the precipitation, and additional sampling (instrument, environmental) considerations. The contribution from low clouds (e.g., cloud top < 4 km) to the overall precipitation over midlatitude oceans is poorly understood, in part because of the lack of coupled, high-quality measurements of precipitation and low-cloud properties. Cloud regime and precipitation breakdowns performed for a multi-year record emphasize the diurnal precipitation cycle and DSD characteristics for both low and deeper clouds. Results demonstrate that marine low clouds over this ENA location account for a significant (45%) contribution to the total rainfall and exhibit a diurnal cycle in cloud (thickness, top, base) and precipitation characteristics similar to satellite records. Additional controls on observed surface rainfall characteristics of low clouds allowed by the extended ground-based facility datasets are also explored. From those analyses, it is suggested that the synoptic state exerts a significant control on low-cloud and surface precipitation properties.

Giangrande, Scott↗

A Broadly Adaptive Array of Dose-Constraint Templates for Planning of Intensity-Modulated Radiation Therapy for Advanced T-Stage Nasopharyngeal Carcinoma

Purpose: To develop and validate adaptive dose-constraint templates in intensity-modulated radiotherapy (IMRT) planning for advanced T-stage nasopharyngeal carcinoma (NPC). Method and Materials: Dose-volume histograms of clinically approved plans for 20 patients with advanced T-stage NPC were analyzed, and the pattern of distribution in relation to the degree of overlap between targets and organs at risk (OARs) was explored. An adaptive dose constraint template (ADCT) was developed based on the degree of overlap. Another set of 10 patients with advanced T-stage NPC was selected for validation. Results of the manual arm optimization protocol and the ADCT optimization protocol were compared with respect to dose optimization time, conformity indices, multiple-dose end points, tumor control probability, and normal tissue complication probability. Results: For the ADCT protocol, average time required to achieve an acceptable plan was 9 minutes, with one optimization compared with 94 minutes with more than two optimizations of the manual arm protocol. Target coverage was similar between the manual arm and ADCT plans. A more desirable dose distribution in the region of overlap between planning target volume and OARs was achieved in the ADCT plan. Dose end points of OARs were similar between the manual arm and ADCT plans. Conclusions: With the developed ADCT, IMRT treatment planning becomes more efficient and less dependent on the planner's experience on dose optimization. The developed ADCT is applicable to a wide range of advanced T-stage NPC treatment and has the potential to be applied in a broader context to IMRT planning for other cancer sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biomechanics of the Treadmill Locomotion on the International Space Station

Exercise prescriptions completed by International Space Station (ISS) crewmembers are typically based upon evidence obtained during ground-based investigations, with the assumption that the results of long-term training in weightlessness will be similar to that attained in normal gravity. Coupled with this supposition are the assumptions that exercise motions and external loading are also similar between gravitational environments. Normal control of locomotion is dependent upon learning patterns of muscular activation and requires continual monitoring of internal and external sensory input [1]. Internal sensory input includes signals that may be dependent on or independent of gravity. Bernstein hypothesized that movement strategy planning and execution must include the consideration of segmental weights and inertia [2]. Studies of arm movements in microgravity showed that individuals tend to make errors but that compensation strategies result in adaptations, suggesting that control mechanisms must include peripheral information [3-5]. To date, however, there have been no studies examining a gross motor activity such as running in weightlessness other than using microgravity analogs [6-8]. The objective of this evaluation was to collect biomechanical data from crewmembers during treadmill exercise before and during flight. The goal was to determine locomotive biomechanics similarities and differences between normal and weightless environments. The data will be used to optimize future exercise prescriptions. This project addresses the Critical Path Roadmap risks 1 (Accelerated Bone Loss and Fracture Risk) and 11 (Reduced Muscle Mass, Strength, and Endurance). Data were collected from 7 crewmembers before flight and during their ISS missions. Before launch, crewmembers performed a single data collection session at the NASA Johnson Space Center. Three-dimensional motion capture data were collected for 30 s at speeds ranging from 1.5 to 9.5 mph in 0.5 mph increments with a 12-camera system. During flight, each crewmember completed up to 6 data collection sessions spread across their missions, performing their normal exercise prescription for the test day, resulting in varying data collection protocols between sessions. Motion data were collected by a single HD video camera positioned to view the crewmembers' left side, and tape markers were placed on their feet, legs, and neck on specific landmarks. Before data collection, the crewmembers calibrated the video camera. Video data were collected during the entire exercise session at 30 Hz. Kinematic data were used to determine left leg hip, knee, and ankle range of motion and contact time, flight time, and stride time for each stride. 129 trials in weightlessness were analyzed. Mean time-normalized strides were found for each trial, and cross-correlation procedures were used to examine the strength and direction of relationships between segment movement pattern timing in each gravitational condition. Cross-correlation analyses between gravitational conditions revealed highly consistent movement patterns at each joint. Peak correlation coefficients occurred at 0% phase, indicating there were no lags in movement timing. Joint ranges of motion were similar between gravitational conditions, with some slight differences between subjects. Motion patterns in weightlessness were highly consistent at a given speed with those occurring in 1G, indicating that despite differing sensory input, subjects maintain running kinematics. The data suggest that individuals are capable of compensating for loss of limb weight when creating movement strategies. These results have important implications for creating training programs for use in weightlessness as practitioners can have greater confidence in running motions transferring across gravitational environments. Furthermore, these results have implications for use by researchers investigating motor control mechanisms and investigating hypotheses related to movement strategies when using sensory input that is dependent upon gravity.

DeWitt, John↗

Disturbance observer-based dynamic optimal setting control

This paper deals with optimal operational control problems using a novel approach where a performance index is optimized by controller design together with set-points reselection. Firstly, the operational indices are obtained by employing some optimization algorithms. The controller is then designed for each closed loop to ensure the controlled variables can track the set points in the ideal situation. Taking advantage of disturbance observers, the set-points are reselected dynamically to minimize the effect caused by unexpected noises or disturbances. In the proposed method, the controller structure or parameters are never changed no matter what kind of disturbances affect the whole system. Finally, simulations on a 3 degrees of freedom robotic arm model are given to demonstrate the effectiveness and convenience of the proposed strategy.

Optimal control, Observer design, Setting Control↗

MSFC-TVC | TB-03: Derivation of Thrust Vector Control (TVC) Actuator-Force / Gimbal-Torque Transformation Matrix

Thrust vector control (TVC) systems for rocket engine propulsion traditionally use a simple linear relationship to convert between actuator forces and torques about the engine gimbal’s center-of-rotation (COR). As shown in Equation (1), the torque about the gimbal COR is proportional to the applied actuator force and the TVC moment arm (MA)—the perpendicular distance between the TVC actuator’s line-of-action (LOA) and the engine gimbal’s COR. While this fundamental relationship remains valid and accurate in a two-dimensional (2D), one-degree-of-freedom (1-DOF) context—particularly in its non-linear formulation as described in the ER63 Technical Bulletin TB-02 (Derivation of Thrust Vector Control (TVC) Engine-Gimbal / Actuator Moment-Arm Geometry)—it becomes limited when extended to three-dimensional (3D), two-degree-of-freedom (2-DOF) analyses. In 3D, out-of-plane angular displacements can arise, causing the gimbaled engine plane-of-motion to become non-coplanar with the respective actuator plane-of-motion. Such misalignments occur due to the rod-end (RE) and/or tail-stock (TE) mounting geometry of individual TVC actuators. These geometric complexities lead to inaccuracies in calculating engine torques and corresponding actuator forces if only the traditional TVC MA relationship is employed. For higher gimbal angular displacements (e.g., greater than 5 degrees), these inaccuracies become more pronounced, necessitating a more robust mathematical framework. This document presents a comprehensive 3D (2-DOF) derivation of a transformation matrix that accurately converts between gimbaled engine torques and TVC actuator forces. By incorporating the necessary geometric and rotational considerations, this new approach corrects the limitations of the traditional TVC MA method. Subsequent sections compare the newly formulated approach to the traditional method, demonstrating its enhanced accuracy and reliability for a broad range of gimbaled engine conditions.

Thrust Vector Control↗

An innovative exercise method to simulate orbital EVA work - Applications to PLSS automatic controls

An exercise method has been proposed which may satisfy the current need for a laboratory simulation representative of muscular, cardiovascular, respiratory, and thermoregulatory responses to work during orbital extravehicular activity (EVA). The simulation incorporates arm crank ergometry with a unique body support mechanism that allows all body position stabilization forces to be reacted at the feet. By instituting this exercise method in laboratory experimentation, an advanced portable life support system (PLSS) thermoregulatory control system can be designed to more accurately reflect the specific work requirements of orbital EVA.

Lantz, Renee↗

Dose-Escalated Intensity-Modulated Radiotherapy Is Feasible and May Improve Locoregional Control and Laryngeal Preservation in Laryngo-Hypopharyngeal Cancers

Purpose: To determine the safety and outcomes of induction chemotherapy followed by dose-escalated intensity-modulated radiotherapy (IMRT) with concomitant chemotherapy in locally advanced squamous cell cancer of the larynx and hypopharynx (LA-SCCL/H). Methods and Materials: A sequential cohort Phase I/II trial design was used to evaluate moderate acceleration and dose escalation. Patients with LA-SCCL/H received IMRT at two dose levels (DL): DL1, 63 Gy/28 fractions (Fx) to planning target volume 1 (PTV1) and 51.8 Gy/28 Fx to PTV2; DL2, 67.2 Gy/28 Fx and 56 Gy/28 Fx to PTV1 and PTV2, respectively. Patients received induction cisplatin/5-fluorouracil and concomitant cisplatin. Acute and late toxicities and tumor control rates were recorded. Results: Between September 2002 and January 2008, 60 patients (29 DL1, 31 DL2) with Stage III (41% DL1, 52% DL2) and Stage IV (52% DL1, 48% DL2) disease were recruited. Median (range) follow-up for DL1 was 51.2 (12.1-77.3) months and for DL2 was 36.2 (4.2-63.3) months. Acute Grade 3 (G3) dysphagia was higher in DL2 (87% DL2 vs. 59% DL1), but other toxicities were equivalent. One patient in DL1 required dilatation of a pharyngeal stricture (G3 dysphagia). In DL2, 2 patients developed benign pharyngeal strictures at 1 year. One underwent a laryngo-pharyngectomy and the other a dilatation. No other G3/G4 toxicities were reported. Overall complete response was 79% (DL1) and 84% (DL2). Two-year locoregional progression-free survival rates were 64.2% (95% confidence interval, 43.5-78.9%) in DL1 and 78.4% (58.1-89.7%) in DL2. Two-year laryngeal preservation rates were 88.7% (68.5-96.3%) in DL1 and 96.4% (77.7-99.5%) in DL2. Conclusions: At a mean follow-up of 36 months, dose-escalated chemotherapy-IMRT at DL2 has so far been safe to deliver. In this study, DL2 delivered high rates of locoregional control, progression-free survival, and organ preservation and has been selected as the experimental arm in a Cancer Research UK Phase III study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multi-Tier Provenance Model for Global Climate Research

Global climate researchers rely upon many forms of sensor data and analytical methods to help profile subtle changes in climate conditions. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) program provides researchers with curated products called Value Added Products (VAPs) resulting from continuous instrumentation streams, data fusion, and analytical profiling. To provide these projects the ARM operations and research teams rely upon a number of techniques to ensure strict quality control and quality assurance codes are maintained. End users in the climate research community are highly interested in obtaining as much causal evidence as possible and currently either not all the evidence are easily attainable or easily identifiable without significant effort. Our research interests are to identify a provenance model that serves both the producers and consumers of the VAP maintaining the quality assurance/quality control standards and tailored to meeting the individual researcher’s needs.

54 ENVIRONMENTAL SCIENCES↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Southern Great Plains Merged and Extended Cloud Condensation Nuclei Data

This data set contains best-estimate cloud condensation nuclei (CCN) spectra for five years of data (2009-2013) at the DOE Atmospheric Radiation Measurement Southern Great Plains (SGP) observatory at 45-minute time resolution. All CCN spectra span a wide SSw range, 0.0001% to ~30%, which is not measurable by CCN instrumentation alone. This product has been constructed by combining merged aerosol size distribution data (Marinescu, Peter, and Levin, Ezra. SGP Merged Aerosol Size Distribution (CPC+SMPS+APS). United States: N. p., 2019. Web. doi:10.5439/1511037 discussed in: Marinescu, PJ, EJT Levin, D Collins, SM Kreidenweis, and SC van den Heever. 2019. "Quantifying Aerosol Size Distributions and Their Temporal Variability in the Southern Great Plains, USA." Atmospheric Chemistry and Physics 19(18): 11985&ndash;12006, https://doi.org/10.5194/acp-19-11985-2019) with measurements of aerosol hygroscopicity from the humidified tandem differential mobility analyzer (HTDMA) and measured CCN distributions over a limited water supersaturation (SSw) range. Nephelometer and aerosol chemical speciation monitor (ACSM) data are used to resolve discrepancies between the above measurements, and as quality control measures.

54 ENVIRONMENTAL SCIENCES↗

Recursive Linearization Of Dynamical Models Of Manipulators

Report shows how spatial-operator algebra developed by authors used to derive linearized mathematical models of dynamics of robotic manipulators. Aspects of spatial-operator algebra also described in "Robot Control Based On Spatial-Operator Algebra" (NPO-17918), "Unified Formulation Of Dynamics Of Robot Arms" (NPO-18040), and "Spatial-Operator Algebra For Robotic Manipulators" (NPO-17770).

Jain, Abhinandan↗

A Petri net controller for distributed hierarchical systems

The solutions to a wide variety of problems are often best organized as a distributed hierarchical system. These systems can be graphically and mathematically modeled through the use of Petri nets, which can easily represent synchronous, asynchronous, and concurrent operations. This thesis presents a controller implementation based on Petri nets and a design methodology for the interconnection of distributed Petri nets. Two case studies are presented in which the controller operates a physical system, the Center for Intelligent Robotic Systems for Space Exploration Dual Arm Robotic Testbed.

Peck, Joseph E.↗

Elastin cross-linking in the skin from patients with amyotrophic lateral sclerosis

Two cross-links unique to elastin, desmosine and isodesmosine were measured and compared in skin tissue (left upper arm) from 10 patients with amyotrophic lateral sclerosis (ALS) and from seven age-matched controls. The contents of desmosine and isodesmosine were significantly decreased (p < 0.01 and p < 0.01, respectively) in patients with ALS compared with those of controls, and were negatively and significantly associated with duration of illness in ALS patients (r = -0.77, p < 0.01 and r = -0.65, p < 0.05, respectively). The decline in skin desmosine and isodesmosine is more rapid in ALS than in normal ageing. Thus cross-linking of skin elastin is affected in ALS.

Non-NASA Center↗

TPSAS-NF1676L-21010-DND

The primary objective of this work is the dynamic analyses of the Tendon-Actuated Lightweight In-Space Manipulator (TALISMAN) which entails structural dynamics, multi-body dynamics and flexible multi-body dynamics modeling and simulation of robotic systems, associated space vehicles and operations. The dynamic analysis is in the critical path of TALISMAN technology development for utilization in the Asteroid Redirect Mission (ARM) and for potential application to Satellite Servicing Missions (SSM). In addition, modeling work supports control design, and the testing of space operations.

Cornelia Altenbuchner↗

Heat Control via Torque Control in Friction Stir Welding

In a proposed advance in friction stir welding, the torque exerted on the workpiece by the friction stir pin would be measured and controlled in an effort to measure and control the total heat input to the workpiece. The total heat input to the workpiece is an important parameter of any welding process (fusion or friction stir welding). In fusion welding, measurement and control of heat input is a difficult problem. However, in friction stir welding, the basic principle of operation affords the potential of a straightforward solution: Neglecting thermal losses through the pin and the spindle that supports it, the rate of heat input to the workpiece is the product of the torque and the speed of rotation of the friction stir weld pin and, hence, of the spindle. Therefore, if one acquires and suitably processes data on torque and rotation and controls the torque, the rotation, or both, one should be able to control the heat input into the workpiece. In conventional practice in friction stir welding, one uses feedback control of the spindle motor to maintain a constant speed of rotation. According to the proposal, one would not maintain a constant speed of rotation: Instead, one would use feedback control to maintain a constant torque and would measure the speed of rotation while allowing it to vary. The torque exerted on the workpiece would be estimated as the product of (1) the torque-multiplication ratio of the spindle belt and/or gear drive, (2) the force measured by a load cell mechanically coupled to the spindle motor, and (3) the moment arm of the load cell. Hence, the output of the load cell would be used as a feedback signal for controlling the torque (see figure).

Venable, Richard↗

Maneuvering and control of flexible space robots

This paper is concerned with a flexible space robot capable of maneuvering payloads. The robot is assumed to consist of two hinge-connected flexible arms and a rigid end-effector holding a payload; the robot is mounted on a rigid platform floating in space. The equations of motion are nonlinear and of high order. Based on the assumption that the maneuvering motions are one order of magnitude larger than the elastic vibrations, a perturbation approach permits design of controls for the two types of motion separately. The rigid-body maneuvering is carried out open loop, but the elastic motions are controlled closed loop, by means of discrete-time linear quadratic regulator theory with prescribed degree of stability. A numerical example demonstrates the approach. In the example, the controls derived by the perturbation approach are applied to the original nonlinear system and errors are found to be relatively small.

Meirovitch, Leonard↗

Metrics of Balance Control for Use in Screening Tests of Vestibular Function

Decrements in balance control have been documented in astronauts after space flight. Reliable measures of balance control are needed for use in postflight field tests at remote landing sites. Diffusion analysis (DA) is a statistical mechanical tool that shows the average difference of the dependent variable on varying time scales. These techniques have been shown to measure differences in open-loop and closed-loop postural control in astronauts and elderly subjects. The goal of this study was to investigate the reliability of these measures of balance control. Eleven subjects were tested using the Clinical Test of Sensory Interaction on Balance: the subject stood with feet together and arms crossed on a stable or compliant surface, with eyes open or closed and with or without head movements in the pitch or yaw plane. Subjects were instrumented with inertial motion sensors attached to their trunk segment. The DA curves for linear acceleration measures were characterized by linear fits measuring open- (Ds) and closed-loop (Dl) control, and their intersection point (X-int, Y-int). Ds and Y-int showed significant differences between the test conditions. Additionally, Ds was correlated with the root mean square (RMS) of the signal, indicating that RMS was dominated by open-loop events (< 0.5 seconds). The Y-int was found to be correlated with the average linear velocity of trunk movements. Thus DA measures could be applied to derive reliable metrics of balance stability during field tests.

Fiedler, Matthew↗