Search NASASearch

SEARCH · Search NASA

Results for “Influenza A virus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,845 records · Page 68

Thermal Testing of High Performance: Thermal Barrier Coatings for Turbine Blades

A 350 micron thick 7 wt.% Y 2 O 3 -ZrO 2 (7YSZ) ceramic Thermal Barrier Coating (TBC) was manufactured in an argon atmosphere and with a strictly controlled substrate temperature on flat IN 600 samples and on IN 100 aircraft turbine blades. This new atmosphere and temperature controlled spraying (ATCS) allows the reduction of the residual stresses and an improvement in the microstructure and in the mechanical properties of the coating. The good performance of these new TBC's was assessed in thermal fatigue and in thermal shock tests carried out in air at 1100°C and at 1280°C respectively. The oxidation rate of the metal-ceramic interface was measured at 1100°C. Failure of the TBC's was induced only by the deterioration (like oxidation, cracking, ...) of the uncoated parts of the samples, as testing temperature was too severe for the base metals. Spalling was thereafter driven by compressive stresses near the aluminum oxide layer at the metal-ceramic interface. The results of these tests underline the good quality of the ceramic coating manufactured by the new ATCS technology.

L Bertamini

High‐Loading Lithium‐Sulfur Batteries with Solvent‐Free Dry‐Electrode Processing

Abstract Lithium‐sulfur (Li‐S) batteries, with their high energy density, nontoxicity, and the natural abundance of sulfur, hold immense potential as the next‐generation energy storage technology. To maximize the actual energy density of the Li‐S batteries for practical applications, it is crucial to escalate the areal capacity of the sulfur cathode by fabricating an electrode with high sulfur loading. Herein, ultra‐high sulfur loading (up to 12 mg cm −2 ) cathodes are fabricated through an industrially viable and sustainable solvent‐free dry‐processing method that utilizes a polytetrafluoroethylene binder fibrillation. Due to its low porosity cathode architecture formed by the binder fibrillation process, the dry‐processed electrodes exhibit a relatively lower initial capacity compared to the slurry‐processed electrode. However, its mechanical stability is well maintained throughout the cycling without the formation of electrode cracking, demonstrating significantly superior cycling stability. Additionally, through the optimization of the dry‐processing, a single‐layer pouch cell with a loading of 9 mg cm −2 and a novel multi‐layer pouch cell that uses an aluminum mesh as its current collector with a total loading of 14 mg cm −2 are introduced. To address the reduced initial capacity of dry‐processed electrodes, strategies such as incorporating electrocatalysts or employing prelithiated active materials are suggested.

Chemistry

Nuclear Safety [Vol. 37, No. 2, April-June 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 97 The Nuclear Community and the Public: Cognitive and Cultural Influences on Thinking About Nuclear Risk, M. A. Meyer; 109 Twenty-Third Water Reactor Safety Information Meeting, D. A. Copinger; ACCIDENT ANALYSIS: 126 Analysis of a PWR LBLOCA Without SCRAM, Trevor N. Tyler, Rafael Macian-Juan and John H. Mahaffy; DESIGN FEATURES: 139 Vulnerability of Multiple-Barrier Systems, N. C. Lind; ENVIRONMENTAL EFFECTS: 149 A Study of Wet Catalytic Oxidation of Radioactive Spent Ion Exchange Resin by Hydrogen Peroxide, Xingchao Jian, Tianbao Wu, and Guichun Yun; 157 A Comparison Study and Resolution of Differences Between Emergency Response and Safety Analysis Codes Used at the Savannah River Site, A. A. Simpkins; OPERATING EXPERIENCES: 164 Reactor Shutdown Experience, Compiled by J. W. Cletcher; RECENT DEVELOPMENTS: 167 Reports, Standards, and Safety Guides, D. S. Queener; 172 Proposed Rule Changes as of Dec. 31,1995; ANNOUNCEMENTS: 178 American Nuclear Society 1997 Annual Meeting; 178 American Nuclear Society Nuclear Criticality and Safety Division Topical Meeting; 176 The Authors.

05 NUCLEAR FUELS

Analysis of the Erosion of Cubic Centered and Face Centered Metallic Materials [Analyse de L'erosion de Matereaux Metalliques de Structures Cubiques Centree et Face Centree]

A generalized law of erosion, in nondimensional form, is proposed. The aforementioned explicitly gives an account of the nature and the microstructure of the material impacted, the angle of impact of the particles, and their hardness. The erosion behavior of various steels, pig iron, and cast iron is examined as well as the behavior of new ordered intermetallic materials, Fe-25% Al-(Zr, Cr, B). The concern of such alloys in an erosion-corrosion environment is shown. --- Une loi généralisée d'usure par érosion, sous forme non dimensionnelle, est proposée. Celle-ci rend compte explicitement de la nature et de la microstructure du matériau impacté, de l'angle d'impact des particules, de leur acuité at de leur durete. Le comportement à l'érosion de divers aciers et fontes est examiné ainsi que la tenue de nouveaux matériaux intermétalliques ordonnés Fe-25% Al - (Zr, Cr, B). L'interet de tels alliages dans des environnements agressifs du type érosion-corrosion est montré. Mots clés: usure, érosion, modèle, matériaux métalliques, intermétalliques Fe-Al.

A Magnée

Charm and bottom hadrons in hot hadronic matter

Heavy quarks, and the hadrons containing them, are excellent probes of the QCD medium formed in high-energy heavy-ion collisions, as they provide essential information on the transport properties of the medium and how quarks color-neutralize into hadrons. Large theoretical and phenomenological efforts have been dedicated thus far to assess the diffusion of charm and bottom quarks in the quark–gluon plasma and their subsequent hadronization into heavy-flavor (HF) hadrons. However, the fireball formed in heavy-ion collisions also features an extended hadronic phase, and therefore any quantitative analysis of experimental observables needs to account for the rescattering of charm and bottom hadrons. This is further reinforced by the presence of a QCD cross-over transition and the notion that the interaction strength is maximal in the vicinity of the pseudo-critical temperature. We review existing approaches for evaluating the interactions of open HF hadrons in a hadronic heat bath and the pertinent results for scattering amplitudes, spectral functions and transport coefficients. While most of the work to date has focused on D -mesons, we also discuss excited states as well as HF baryons and the bottom sector. Both the HF hadro-chemistry and bottom observables will play a key role in future experimental measurements. We also conduct a survey of transport calculations in heavy-ion collisions that have included effects of hadronic HF diffusion and assess its impact on various observables.

effective field theories

Exploring the Model Design Space for Battery Health Management

Battery Health Management (BHM) is a core enabling technology for the success and widespread adoption of the emerging electric vehicles of today. Although battery chemistries have been studied in detail in literature, an accurate run-time battery life prediction algorithm has eluded us. Current reliability-based techniques are insufficient to manage the use of such batteries when they are an active power source with frequently varying loads in uncertain environments. The amount of usable charge of a battery for a given discharge profile is not only dependent on the starting state-of-charge (SOC), but also other factors like battery health and the discharge or load profile imposed. This paper presents a Particle Filter (PF) based BHM framework with plug-and-play modules for battery models and uncertainty management. The batteries are modeled at three different levels of granularity with associated uncertainty distributions, encoding the basic electrochemical processes of a Lithium-polymer battery. The effects of different choices in the model design space are explored in the context of prediction performance in an electric unmanned aerial vehicle (UAV) application with emulated flight profiles.

Saha, Bhaskar

Single-Drop Reactive Extraction/Extractive Reaction With Forced Convective Diffusion and Interphase Mass Transfer

An algorithm has been developed for time-dependent forced convective diffusion-reaction having convection by a recirculating flow field within the drop that is hydrodynamically coupled at the interface with a convective external flow field that at infinity becomes a uniform free-streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet, or reactions can take place in both phases. The algorithm has been implemented, and for comparison results are shown here for the case of no reaction in either phase and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.

Leonid S Kleinman

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Effect of Fe on Co-Based SiO2Al2O3 Mixed Support Catalyst for Fischer–Tropsch Synthesis in 3D-Printed SS Microchannel Microreactor

This research explores the effect of a composite support of SiO2 and Al2O3 with Fe and Co incorporated as catalysts for Fischer–Tropsch synthesis (FTS) using a 3D-printed stainless steel (SS) microchannel microreactor. Two mesoporous catalysts, FeCo/SiO2Al2O3 and Co/SiO2Al2O3, were synthesized via a one-pot (OP) method and extensively characterized using N2 physisorption, XRD, SEM, TEM, H2-TPR, TGA-DSC, FTIR, and XPS. H2-TPR results revealed that the synthesis method significantly affected the reducibility of metal oxides, thereby influencing the formation of active FTS sites. SEM-EDS and TEM further revealed a well-defined hexagonal matrix with a porous surface morphology and uniform metal ion distribution. FTS reactions, carried out in the 200–350 °C temperature range at 20 bar with a H2/CO molar ratio of 2:1, exhibited the highest activity for FeCo/SiO2Al2O3, with up to 80% CO conversion. Long-term stability was evaluated by monitoring the catalyst performance for 30 h on stream at 320 °C under identical reaction conditions. The catalyst was initially active for the methanation reaction for up to 15 h, after which the selectivity for CH4 declined. Correspondingly, the C4+ selectivity increased after 15 h of time-on-stream, indicating a shift in the product distribution toward longer-chain hydrocarbons. This trend suggests that the catalyst undergoes gradual activation or restructuring under reaction conditions, which enhances chain growth over time. The increase in C4+ products may be attributed to the stabilization of the active sites and suppression of methane or light hydrocarbon formation.

Biochemistry & Molecular Biology

Sustainable Production of Biomass‐Derived Graphite and Graphene Conductive Inks from Biochar

Abstract Graphite is a commonly used raw material across many industries and the demand for high‐quality graphite has been increasing in recent years, especially as a primary component for lithium‐ion batteries. However, graphite production is currently limited by production shortages, uneven geographical distribution, and significant environmental impacts incurred from conventional processing. Here, an efficient method of synthesizing biomass‐derived graphite from biochar is presented as a sustainable alternative to natural and synthetic graphite. The resulting bio‐graphite equals or exceeds quantitative quality metrics of spheroidized natural graphite, achieving a RamanI D /I G ratio of 0.051 and crystallite size parallel to the graphene layers (L a ) of 2.08 µm. This bio‐graphite is directly applied as a raw input to liquid‐phase exfoliation of graphene for the scalable production of conductive inks. The spin‐coated films from the bio‐graphene ink exhibit the highest conductivity among all biomass‐derived graphene or carbon materials, reaching 3.58 ± 0.16 × 10 4 S m −1 . Life cycle assessment demonstrates that this bio‐graphite requires less fossil fuel and produces reduced greenhouse gas emissions compared to incumbent methods for natural, synthesized, and other bio‐derived graphitic materials. This work thus offers a sustainable, locally adaptable solution for producing state‐of‐the‐art graphite that is suitable for bio‐graphene and other high‐value products.

Chemistry

Determination of Local Experimental Heat-Transfer Coefficients on Combustion Side of an Ammonia-Oxygen Rocket

Local experimental heat-transfer coefficients were measured in the chamber and throat of a 2400-pound-thrust ammonia-oxygen rocket engine with a nominal chamber pressure of 600 pounds per square inch absolute. Three injector configurations were used. The rocket engine was run over a range of oxidant-fuel ratio and chamber pressure. The injector that achieved the best performance also produced the highest rates of heat flux at design conditions. The heat-transfer data from the best-performing injector agreed well with the simplified equation developed by Bartz at the throat region. A large spread of data was observed for the chamber. This spread was attributed generally to the variations of combustion processes. The spread was least evident, however, with the best-performing injector.

Curt H Liebert

Elastic-plastic models for multi-site damage

This paper presents recent developments in advanced analysis methods for the computation of stress site damage. The method of solution is based on the p-version of the finite element method. Its implementation was designed to permit extraction of linear stress intensity factors using a superconvergent extraction method (known as the contour integral method) and evaluation of the J-integral following an elastic-plastic analysis. Coarse meshes are adequate for obtaining accurate results supported by p-convergence data. The elastic-plastic analysis is based on the deformation theory of plasticity and the von Mises yield criterion. The model problem consists of an aluminum plate with six equally spaced holes and a crack emanating from each hole. The cracks are of different sizes. The panel is subjected to a remote tensile load. Experimental results are available for the panel. The plasticity analysis provided the same limit load as the experimentally determined load. The results of elastic-plastic analysis were compared with the results of linear elastic analysis in an effort to evaluate how plastic zone sizes influence the crack growth rates. The onset of net-section yielding was determined also. The results show that crack growth rate is accelerated by the presence of adjacent damage, and the critical crack size is shorter when the effects of plasticity are taken into consideration. This work also addresses the effects of alternative stress-strain laws: The elastic-ideally-plastic material model is compared against the Ramberg-Osgood model.

Actis, Ricardo L.

Power and Propulsion Element Steerable High Gain Antenna Lunar Transit Thermal Analysis Tracking Methodology

The Power and Propulsion Element (PPE) is an ion thruster propulsion spacecraft developed as an element of Space Reactor (SR-1) Freedom to provide propulsion, communications and power for the spacecraft. PPE was originally being developed for the use with the lunar orbiting space station Gateway as one of the first two planned elements. PPE was to be launched with the Habitation and Logistics Outpost (HALO) element in a configuration called the Co-Manifested Vehicle (CMV) that would arrive at a Near-Rectilinear Halo Orbit (NRHO) around the Moon via a lunar transit spiral trajectory phase. The PPE communication system is equipped with two Steerable High Gain Antennas (SHGA) each steered by a two-axis gimbal (TAG) mechanism. A thermal analysis was conducted during the near-Earth spiral phase of the mission using Thermal Desktop (TD). This analysis utilized multiple axis Earth tracking articulators in combination with SINDA system internal environmental heating symbols to produce accurate Earth ground station tracking communication system temperatures. This presentation provides an overview of the communication system thermal model and the analysis methodology.

Thermal Analysis

Photophoretic Propulsion Enabling Mesosphere Exploration NIAC Phase I Final Report

This Phase I report presents a comprehensive study on photophoretic flyers—innovative, ultralight, solar-powered vehicles that harness photophoretic forces generated via Knudsen pumping to achieve sustained flight in the mesosphere (50–80 km altitude). By integrating advanced materials such as nanocardboard— characterized by its extremely low areal density (~1 g/m²) and high bending stiffness—with ultrathin light-absorbing coatings, the project converts incident solar radiation directly into a directed thrust. Extensive experimental investigations, coupled with high-fidelity computational fluid dynamics (CFD) simulations using ANSYS Fluent, validate the concept across various three-dimensional geometries, including spherical, conical, and rocket-shaped configurations. These simulations bridge the gap between free-molecular and continuum flow regimes, demonstrating that optimized designs can generate lift forces sufficient to support kilogram-scale payloads even in low-pressure environments. At the heart of this innovation is the use of Knudsen pumping, where temperature gradients across porous surfaces induce directional gas flow, creating a modest overpressure that provides lift. The report introduces an analytical framework that interpolates between the well-known low-Reynolds number drag regime and the high-Reynolds number momentum theory. This model accurately predicts lift based on design parameters such as microchannel dimensions, porous wall geometry, areal density, and nozzle exit area. For instance, simulations indicate that 10-meter-scale structures with carefully engineered porous walls can achieve the necessary pressure differential to support scientifically significant payloads (~1 kg). The study also explores a hybrid propulsion approach that combines solar buoyancy with photophoretic lift. Initially, solar heating creates a buoyant force that elevates the flyer to mesospheric altitudes. Once in the optimal pressure range, the photophoretic mechanism—powered by Knudsen pumping—takes over as the primary source of lift, ensuring stable, long-duration flight. This dual-mode operation not only facilitates the deployment of photophoretic flyers but also broadens the potential applications for mesospheric exploration. In addition to propulsion, the report investigates the integration of photophoretic thrusters for trajectory control of existing research balloons in the upper stratosphere. By dynamically adjusting the nozzle orientation and controlling the flow-through velocity, these thrusters provide precise maneuverability, enabling the flyers to counteract atmospheric disturbances and adjust their flight paths in real time. For example, a photophoretic thruster approximately 7.5 by 7.5 meters in size could be unfolded below a payload gondola of a 60 million-cubic-foot zero-pressure balloon. Such a thruster can provide horizontal speed control of approximately 1 m/s using only sunlight and no moving parts (except those needed to track the Sun and control the jet direction). Importantly, photophoretic thrusters operate more efficiently at higher altitudes, which is complementary to known trajectory control techniques, such as propellers and tethered wings, which are more effective at lower altitudes. Finally, the report identifies three scientific research thrusts where mesospheric aircraft technology can have a profound impact: atmospheric tides, characterization of gravity waves, and investigation of mesospheric instabilities. Overall, the findings of this Phase I project represent a significant advancement in photophoretic propulsion technology. By demonstrating that large-scale, ultralight structures can be powered solely by solar radiation—via carefully engineered Knudsen pumping—this work lays a robust foundation for scalable, near-space flight architectures. Future refinements in material fabrication, structural optimization, and integrated trajectory control are expected to further enhance performance, paving the way for operational demonstrations that could revolutionize atmospheric science, remote sensing, and communication networks.

Knudsen Pump

Toyota Highlander FCHV (CRADA CRD-12-00469 Final Report)

This project relates to the loan of four Toyota Mirai FCEV-adv vehicles to NLR to provide a load (vehicles to fill with hydrogen) to our fueling station research facility to study hydrogen fueling infrastructure performance using 700 bar precooled hydrogen at ESIF’s Hydrogen Infrastructure Testing and Research Facility (HITRF) facility.

33 ADVANCED PROPULSION SYSTEMS

Swamp Works Regolith Compaction Technologies

While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technologies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discussions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature and additional lab testing (publication in work).

redwire

Circumventing data imbalance in magnetic ground state data for magnetic moment predictions

Abstract Magnetic materials play a crucial role in the transition to more sustainable forms of energy and electric vehicles. There is an anticipated shortage in magnetic materials in the future, and as a result there is an urgent need to discover and design new magnetic materials. Computational magnetic material design using density functional theory is daunting because of the challenge in identifying magnetic ground states from a combinatorially large set of possibilities. Machine learning offers a path forward by enabling efficient surrogate models that can more readily enumerate these states, but there is a dearth of training data available, and what is available tends to be imbalanced with too much non-magnetic data. In this work we show that the discrete and previously tackled data imbalance that exists at the level of the magnetic ordering leads to an imbalanced continuous distribution with many zeros when the data is unraveled at the atomic magnetic moment level, which subsequently leads to models with low accuracy for magnetic properties. We mitigate this by using a two-part model framework. Our scheme is able to classify atoms into magnetic and non-magnetic with an F1 score and Matthew’s correlation coefficient (MCC) of ~91% and then to provide an implicit embedding representation that maps directly onto the magnitude of the magnetic moment with a mean absolute error of 0.1 μ B . Beyond screening for new magnetic materials, we demonstrate an additional practical use case of our scheme: the provision of good initial guesses for magnetic moments in first-principles electronic relaxations. Such initialization is shown to lead to faster convergence to configurations that lie closer to the ground state.

Computer Science