Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

WDR-PK-AK-018

Method - CES SOP-HW-P556 'Field and Bulk Gamma Analysis'. Detector - High-purity germanium, 40% relative efficiency. Calibration - The detector was calibrated on February 8, 2006 using a NIST-traceable sealed source, and the calibration was verified using an independent sealed source. Count Time and Geometry - The sample was counted for 20 minutes at 72 inches from the detector. A lead collimator was used to limit the field-of-view to the region of the sample. The drum was rotated 180 degrees halfway through the count time. Date and Location of Scans - June 1,2006 in Building 235 Room 1136. Spectral Analysis Spectra were analyzed with ORTEC GammaVision software. Matrix and geometry corrections were calculated using OR TEC Isotopic software. A background spectrum was measured at the counting location. No man-made radioactivity was observed in the background. Results were determined from the sample spectra without background subtraction. Minimum detectable activities were calculated by the Nureg 4.16 method. Results - Detected Pu-238, Pu-239, Am-241 and Am-243.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Numerically Exact Approach to Quantum Impurity Problems in Realistic Lattice Geometries

We review a controlled numerical approach to quantum impurity problems in realistic geometries, consisting of exactly mapping the complete lattice Hamiltonian onto an equivalent one dimensional system through a unitary transformation. The resulting dimensional and entanglement reduction allows one to study the quantum many-body problem on arbitrary d-dimensional lattices using the density matrix renormalization group (DMRG) method. The real-space resolution allows one to position the impurities at the boundary or bulk of the sample and to study screening effects due to edge or surface modes. We describe how to generalize this approach to multi-impurity problems, discuss applications and possible extensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magneto-optical studies of SrGa{sub 0.7} Co{sub 0.3} O{sub 3−δ} perovskite thin films with embedded cobalt nanoparticles

Sr(Ga{sub 0.7} Co{sub 0.3})O{sub 3−δ}/Co perovskite/metal thin films have been systematically studied by means of Faraday and Kerr magneto-optical spectroscopies. The samples were prepared by pulsed laser deposition on (001) (LaAlO{sub 3}) {sub 0.3}(Sr{sub 2}AlTaO{sub 6}) {sub 0.7} (LSAT) and Si substrates, and grew as a perovskite matrix containing approximately 6% by volume of embedded metallic Co nanoparticles with diameter less than 20 nm, which were distributed throughout the film and at the film-substrate interface. The film thickness ranged from 130 to 310 nm. The perovskite matrix was single crystal on LSAT and polycrystalline on Si. The magneto-optical spectroscopy was carried out in both Faraday and Kerr configurations in the photon energy range from 0.5 to 5 eV in magnetic fields sufficient for sample saturation, showing a strong thickness dependence of the magneto-optical effect. This dependence was attributed to the different metallic Co content, nanoparticle size, and accumulation at the film-substrate interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of LPBF Steels for Nuclear Applications

This report provides an update on the prioritization of existing reactor materials for advanced manufacturing. This report is a Milestone 3 deliverable in FY2023, under work package CT-23AN130401 to support research and qualification activities supported by the Advanced Materials and Manufacturing Technologies (AMMT) program here at Argonne National Laboratory (ANL). The focus of FY23 for ANL included the determination of a decision criteria matrix for the prioritization of existing materials, the literature review of a select few Fe-based alloys, and working with vendors to obtain customized powders. The work package also includes fabricating test samples in a Renishaw AM400 Laser Powder Bed Fusion (LPBF) system and optimizing the process parameters. The major outcomes of this work package are: With collaborations from PNNL, ORNL, and INL, we were able to establish a decision criteria matrix containing a total of 6 categories and 31 different criteria. These will be used to downselect alloys for further evaluation; As part of that, 6 different Fe-based alloys were selected, 3 austenitic stainless steels (A709, D9, AFA) and 3 ferritic/martensitic steels (HT9, Grade 91, Grade 92). Customized powders were obtained from vendors in small quantities to fabricate initial prints to check printability of these specific alloys; A total of 72 single track experiments were performed on two alloy systems, 1 austenitic stainless steel (A709) and 1 ferritic/martensitic steel (Grade 91) in order to optimize the process parameters for the full 3d prints. The optimization led to the selection of 20 different processing conditions, 10 for each class of alloys; D9 and AFA alloys showed extensive cracking and porosity in the samples. This was due to less-than-ideal conditions present in the chamber during the deposition. A709 printed using the same process parameters showed almost fully dense samples with no noticeable porosity or any other defects. SEM and EBSD analysis revealed single phase FCC microstructure with cellular structure within the grains; HT9, Grade 91, Grade 92 alloys also showed no noticeable signs of cracking and ImageJ analysis showed porosity <0.5% in all conditions. While Grade 91 and Grade 92 showed single phase BCC microstructures, the presence of martensite laths was noted in HT9 alloy; Future work will include further characterization of these alloys to better understand the microstructural evolution during the 3d printing process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimized purification methods for metallic contaminant removal from directly recycled Li-ion battery cathodes

Metallic contaminants pose a significant challenge to the viability of directly recycling Li-ion batteries. To date, few strategies exist to selectively remove metallic impurities from mixtures of shredded end-of-life material (black mass; BM) without concurrently damaging the structure and electrochemical performance of the target active material. We herein present tailored methods to selectively ionize two major contaminants—Al and Cu—while retaining a representative cathode (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ; NMC-111) intact. This BM purification process is conducted at moderate temperatures in a KOH-based solution matrix. We rationally evaluate approaches to increase both the kinetic corrosion rate and the thermodynamic solubility of Al 0 and Cu 0 , and evaluate the impact of these treatment conditions on the structure, chemistry, and electrochemical performance of NMC. Specifically, we explore the impacts of chloride-based salts, a strong chelating agent, elevated temperature, and sonication on the rate and extent of contaminant corrosion, while concurrently evaluating the effects on NMC. The reported BM purification process is then demonstrated on samples of “simulated BM” containing a practically relevant 1 wt% concentration of Al or Cu. Increasing the kinetic energy of the purifying solution matrix through elevated temperature and sonication accelerates the corrosion of metallic Al and Cu, such that ∼100% corrosion of 75 μm Al and Cu particles is achieved within 2.5 hr. Further, we determine that effective mass transport of ionized species critically impacts the efficacy of Cu corrosion, and that saturated Cl – hinders rather than accelerates Cu corrosion by increasing solution viscosity and introducing competitive pathways for Cu surface passivation. The purification conditions do not induce bulk structural damage to NMC, and electrochemical capacity is maintained in half-cell format. Testing in full cells suggests that a limited quantity of residual surface species are present after treatment, which initially disrupt electrochemical behavior at the graphite anode but are subsequently consumed. Process demonstration on simulated BM suggests that contaminated samples—which prior to treatment show catastrophic electrochemical performance—can be recovered to pristine electrochemical capacity. The reported BM purification method offers a compelling and commercially viable solution to address contamination, particularly in the “fine” fraction of BM where contaminant sizes are on the same order of magnitude as NMC and where traditional separation approaches are unfeasible. Thus, this optimized BM purification technique offers a pathway towards viable direct recycling of BM feedstocks that would otherwise be unusable.

25 ENERGY STORAGE↗

Coupled Transport, Reactivity, and Mechanics in Fractured Shale Caprocks

Abstract Shales are low‐permeability caprocks that confine fluid, such as CO 2 , nuclear waste, and hydrogen, in storage formations. Stress‐induced fractures in shale caprocks provide pathways for fluid to leak and potentially contaminate fresh water aquifers. Fractured shales are also increasingly considered as resources for CO 2 sequestration, enhanced geothermal, and unconventional energy recovery. Injecting reactive fluids into shales introduces chemical disequilibrium, causing an onset of a series of dissolution, precipitation, and fines mobilization mechanisms. The reactions have rapid kinetics and significant impact on porosity and permeability; consequently, flow and storage properties of caprocks. While previous research has explored the separate effects of these reactions, this study aims to uncover their simultaneous occurrence and collective influence. This study unveils these highly coupled transport and reactivity mechanisms by tracking and visualizing the reaction‐induced alterations in the matrix, microcracks, and fractures of shales over time. We conducted brine injection experiments sequentially at pH 4 and 2 in a naturally fractured Wolfcamp shale sample while simultaneously imaging the dynamic processes using X‐ray computed tomography (CT). CT images are validated by finer resolution images obtained using micro‐CT and scanning electron microscopy. We also tracked the sample permeability and fluid chemistry using brine permeability and inductively coupled plasma mass spectrometry, respectively. Findings show that fluid primarily flowed through fractures, dissolving reactive minerals and mobilizing fines on fracture surfaces. Dissolution of fracture asperities under confining stress resulted in the closing of fractures. Clogging in narrow fracture pathways, caused by fines accumulation, diverted fluid flow into matrix pores.

58 GEOSCIENCES↗

Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83 ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24 h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. - Highlights: • We analyzed levels of endocrine disruptors in adipose tissue, serum and urine. • We found BPA, TCS, BP-3, 2-PP and MeP in >40% of the adipose tissue samples. • Adipose tissue levels of npEDCs did not correlate with those in urine or serum. • Adipose tissue levels may have a different biological meaning.

54 ENVIRONMENTAL SCIENCES↗

Formation of ionic complexes in cryogenic matrices: A case study using co-deposition of Cu{sup −} with rare gas cations in solid argon

Matrix isolation spectra have been obtained for ionic species formed from a beam of mass-selected ions, with a coincident beam of externally generated counter-ions used to provide charge balance. Infrared spectra were obtained for copper carbonyl complexes formed following deposition of Cu{sup −} ions with rare-gas counter-cations into CO-doped argon matrices. Both anionic and neutral copper carbonyl complexes Cu(CO){sub n}{sup q} (n = 1–3; q = 0, −1) were observed in the spectra, with peak positions corresponding to previously reported assignments; new partially resolved bands appearing in the range 1830–1845 cm{sup −1} are assigned to larger [Cu(CO){sub 3}•(CO){sub n}]{sup −} aggregates, having additional CO ligands in the second solvation shell. The experimental geometry ensures that all Cu-centers initially arrive at the matrix as anions, so the relative abundance of anionic relative to neutral complexes is much higher than in previous studies employing alternative methods for ion deposition; this allows for monitoring of electron-transfer processes between anions and cations in the matrix. Comparison of time-dependent vs. temperature-dependent trends reveals that there are two distinct mechanisms by which the population of anionic complexes is converted into neutral complexes: short-range electron transfer between a cation-anion pair following diffusion, and long-range electron transfer involving photodetachment of an electron from the anion into the conduction band of solid argon, resulting in eventual recombination of the electron with a cation in a remote matrix site. The spectra also show a marked dependence on the deposition temperature and dopant concentration, in that 100-fold higher CO concentrations were required during deposition with the sample window at 10 K compared to that used at 20 K, in order to obtain a similar distribution of copper carbonyl complexes. Furthermore, although no carbonyl complexes are observed initially when low concentrations of CO are used at 10 K, upon warming the matrix to 15 K, the neutral di- and tricarbonyl peaks appear abruptly, which is attributed to fast diffusion of CO stimulated by the energy released upon short-range electron-transfer between Cu{sup −}:counter-cation pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient many-jet event generation with flow matching

We apply for the first time, to the best of our knowledge, the flow matching method to the problem of phase-space sampling for event generation in high-energy collider physics. By training the model to remap the random numbers used to generate the momenta and helicities of the scattering matrix elements as implemented in the portable partonic event generator pepper, we find substantial efficiency improvements in the studied processes. We focus our study on the highest final-state multiplicities in Drell-Yan and top-antitop pair production used in simulated samples for the Large Hadron Collider, which computationally are the most relevant ones. We find that the unweighting efficiencies improve by factors of 184 and 25, respectively, when compared to the standard approach of using a vegas-based optimization. We also compare continuous normalizing flows trained with flow matching against the previously studied normalizing flows based on coupling layers and find that the former leads to better results, faster training and a better scaling behavior across the studied multiplicity range, while the latter evaluate faster. When combining the advantages of both methods using the regflow approach, we find parton-level unweighted event generation walltime gains of about a factor of 10 at the highest final-state multiplicities.

Bothmann, E. [CERN; Gottingen U.] (ORCID:000000016↗

XRD studies of cement embedding matrices containing complexing reagents from decontamination practices

The study of embedding matrix of radioactive waste is an important issue concerning the need to assure the radiological safety requirements for final disposal. The conditioning of the radioactive wastes by cementation process involves also a structural investigation by X-ray diffraction (XRD) of the samples prepared with cement and complexing agents at different concentration. This paper gives useful information about the influence of complexing agents related to damages produced in concrete microstructures. The experimental data obtained on samples kept in real repository environment for a period up to 15 years, offer structural information regarding the interaction between the different decontamination agents with the major components of the matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Experiments to Evaluate Matrix Diffusion of Dissolved Organic Carbon Carbon-14 in Southern Nevada Fractured-rock Aquifers

Dissolved inorganic carbon (DIC) carbon-14 ( 14 C) is used to estimate groundwater ages by comparing the DIC 14 C content in groundwater in the recharge area to the DIC 14 C content in the downgradient sampling point. However, because of chemical reactions and physical processes between groundwater and aquifer rocks, the amount of DIC 14 C in groundwater can change and result in 14 C loss that is not because of radioactive decay. This loss of DIC 14 C results in groundwater ages that are older than the actual groundwater ages. Alternatively, dissolved organic carbon (DOC) 14 C in groundwater does not react chemically with aquifer rocks, so DOC 14 C ages are generally younger than DIC 14 C ages. In addition to chemical reactions, 14 C ages may also be altered by the physical process of matrix diffusion. The net effect of a continuous loss of 14 C to the aquifer matrix by matrix diffusion and then radioactive decay is that groundwater appears to be older than it actually is. Laboratory experiments were conducted to measure matrix diffusion coefficients for DOC 14 C in volcanic and carbonate aquifer rocks from southern Nevada. Experiments were conducted using bromide (Br-) as a conservative tracer and 14 C-labeled trimesic acid (TMA) as a surrogate for groundwater DOC. Outcrop samples from six volcanic aquifers and five carbonate aquifers in southern Nevada were used. The average DOC 14 C matrix diffusion coefficient for volcanic rocks was 2.9 x 10 -7 cm 2 /s, whereas the average for carbonate rocks was approximately the same at 1.7 x 10 -7 cm 2 /s. The average Br- matrix diffusion coefficient for volcanic rocks was 10.4 x 10 -7 cm 2 /s, whereas the average for carbonate rocks was less at 6.5 x 10 -7 cm 2 /s. Carbonate rocks exhibited greater variability in DOC 14 C and Br- matrix diffusion coefficients than volcanic rocks. These results confirmed, at the laboratory scale, that the diffusion of DOC 14 C into southern Nevada volcanic and carbonate aquifers is slower than DIC 14 C. Because of the apparent sorption of 14 C-labeled TMA in the experiments, matrix diffusion coefficients are likely even lower. The reasons for the higher than expected Br-/ 14 C-labeled TMA are unknown. Because the molecular size of TMA is on the low end of the range in molecular size for typical humic substances, the matrix diffusion coefficients for the 14 C-labeled TMA likely represent close to the maximum diffusion rates for DOC 14 C in the volcanic and carbonate aquifers in southern Nevada.

54 ENVIRONMENTAL SCIENCES↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Constructing mutually unbiased bases in dimension six

The density matrix of a qudit may be reconstructed with optimal efficiency if the expectation values of a specific set of observables are known. In dimension six, the required observables only exist if it is possible to identify six mutually unbiased complex (6x6) Hadamard matrices. Prescribing a first Hadamard matrix, we construct all others mutually unbiased to it, using algebraic computations performed by a computer program. We repeat this calculation many times, sampling all known complex Hadamard matrices, and we never find more than two that are mutually unbiased. This result adds considerable support to the conjecture that no seven mutually unbiased bases exist in dimension six.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques

Mass spectrometry imaging (MSI) is a powerful analytical technique that enables label-free spatial localization and identification of molecules in complex samples.1-4 MSI applications range from forensics5 to clinical research6 and from understanding microbial communication7-8 to imaging biomolecules in tissues.1, 9-10 Recently, MSI protocols have been reviewed.11 Ambient ionization techniques enable direct analysis of complex samples under atmospheric pressure without special sample pretreatment.3, 12-16 In fact, in ambient ionization mass spectrometry, sample processing (e.g., extraction, dilution, preconcentration, or desorption) occurs during the analysis.17 This substantially speeds up analysis and eliminates any possible effects of sample preparation on the localization of molecules in the sample.3, 8, 12-14, 18-20 Venter and co-workers have classified ambient ionization techniques into three major categories based on the sample processing steps involved: 1) liquid extraction techniques, in which analyte molecules are removed from the sample and extracted into a solvent prior to ionization; 2) desorption techniques capable of generating free ions directly from substrates; and 3) desorption techniques that produce larger particles subsequently captured by an electrospray plume and ionized.17 This review focuses on localized analysis and ambient imaging of complex samples using a subset of ambient ionization methods broadly defined as “liquid extraction techniques” based on the classification introduced by Venter and co-workers.17 Specifically, we include techniques where analyte molecules are desorbed from solid or liquid samples using charged droplet bombardment, liquid extraction, physisorption, chemisorption, mechanical force, laser ablation, or laser capture microdissection. Analyte extraction is followed by soft ionization that generates ions corresponding to intact species. Some of the key advantages of liquid extraction techniques include the ease of operation, ability to analyze samples in their native environments, speed of analysis, and ability to tune the extraction solvent composition to a problem at hand. For example, solvent composition may be optimized for efficient extraction of different classes of analytes from the sample or for quantification or online derivatization through reactive analysis. In this review, we will: 1) introduce individual liquid extraction techniques capable of localized analysis and imaging, 2) describe approaches for quantitative MSI experiments free of matrix effects, 3) discuss advantages of reactive analysis for MSI experiments, and 4) highlight selected applications (published between 2012 and 2015) that focus on imaging and spatial profiling of molecules in complex biological and environmental samples.

Environmental Molecular Sciences Laboratory↗

Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

Wallace, William T.↗

Unbiased reduced density matrices and electronic properties from full configuration interaction quantum Monte Carlo

Properties that are necessarily formulated within pure (symmetric) expectation values are difficult to calculate for projector quantum Monte Carlo approaches, but are critical in order to compute many of the important observable properties of electronic systems. Here, we investigate an approach for the sampling of unbiased reduced density matrices within the full configuration interaction quantum Monte Carlo dynamic, which requires only small computational overheads. This is achieved via an independent replica population of walkers in the dynamic, sampled alongside the original population. The resulting reduced density matrices are free from systematic error (beyond those present via constraints on the dynamic itself) and can be used to compute a variety of expectation values and properties, with rapid convergence to an exact limit. A quasi-variational energy estimate derived from these density matrices is proposed as an accurate alternative to the projected estimator for multiconfigurational wavefunctions, while its variational property could potentially lend itself to accurate extrapolation approaches in larger systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

Hudson, Nicolas↗