Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Changes in European wind energy generation potential within a 1.5 °C warmer world

Global climate model simulations from the 'Half a degree Additional warming, Prognosis and Projected Impacts ' (HAPPI) project were used to assess how wind power generation over Europe would change in a future world where global temperatures reach 1.5 °C above pre-industrial levels. Comparing recent historical (2006–2015) and future 1.5 °C forcing experiments highlights that the climate models demonstrate a northward shift in the Atlantic jet, leading to a significant (p < 0.01) increase in surface winds over the UK and Northern Europe and a significant (p < 0.05) reduction over Southern Europe. We use a wind turbine power model to transform daily near-surface (10 m) wind speeds into daily wind power output, accounting for sub-daily variability, the height of the turbine, and power losses due to transmission and distribution of electricity. To reduce regional model biases we use bias-corrected 10 m wind speeds. We see an increase in power generation potential over much of Europe, with the greatest increase in load factor over the UK of around four percentage points. Increases in variability are seen over much of central and northern Europe with the largest seasonal change in summer. Focusing on the UK, we find that wind energy production during spring and autumn under 1.5 °C forcing would become as productive as it is currently during the peak winter season. Similarly, summer winds would increase driving up wind generation to resemble levels currently seen in spring and autumn. We conclude that the potential for wind energy in Northern Europe may be greater than has been previously assumed, with likely increases even in a 1.5 °C warmer world. While there is the potential for Southern Europe to see a reduction in their wind resource, these decreases are likely to be negligible.

54 ENVIRONMENTAL SCIENCES↗

Visualization and Analytics of Distribution Systems with Deep Penetration of Distributed Energy Resources (VADER)

In its current state, the distribution system is incapable of handling small to moderate amounts of photovoltaic (PV) penetration. This is because it was initially designed for handling passive loads which, at the level of a substation, have low variability and are forecastable with high accuracy. It has been an open loop system with little monitoring and control. With the addition of PV energy sources, the overall scenario will change dramatically due to (1) two way power flow on network; and (2) high aggregate variability. Additionally, changes on the consumption side lead to a number of smart loads, Electric Vehicles (EVs), and Demand Response. These fundamental changes in the characteristics of the generation and consumption of power will lead to a number of practical engineering problems which must be overcome to allow increased penetration of Distributed PV. Solving the unique engineering challenges which arise at moderate levels of PV penetration requires closed loop integration of data from (1) PV sources; (2) customer load data from smart meters; (3) EV charging data; and (4) local and line mounted precision instruments. These data are not traditionally used by utilities in operations since they are ”non-SCADA” and the current grid does not require such levels of control. To integrate this data and provide real time intelligence from these non-SCADA data, we created the Visualization and Analytics of Distribution Systems with Deep Penetration of Distributed Energy Resources (VADER) platform. VADER is a collection of analytics enabled by integration of massive and heterogeneous data streams for granular real-time monitoring, visualization and control of Distributed Energy Resources (DER) in distribution networks. VADER analytics enable utilities to have greater visibility into distributed energy resources. We built several batch- and stream-analytics in VADER which help operators better understand the impact of distributed energy resources on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water and Wastewater Systems as Potential Distributed Energy Resources for California - High-level Feasibility Assessment

Water systems in California are a major electricity user, and electricity costs represent a significant portion of water utilities’ operating costs. Water and wastewater utilities have the capacity to shift demand in response to grid needs or price signals and can generate power through biogas, hydropower or onsite renewable energy systems like solar panels and wind turbines. This report points to some of the most promising opportunity areas for water and wastewater utilities to implement distributed energy resources while also carefully laying out practical considerations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

The Economic Accessibility of CO2 Sequestration through Bioenergy with Carbon Capture and Storage (BECCS) in the US

Bioenergy with carbon capture and storage (BECCS) is one strategy to remove CO2 from the atmosphere. To assess the potential scale and cost of CO2 sequestration from BECCS in the US, this analysis models carbon sequestration net of supply chain emissions and costs of biomass production, delivery, power generation, and CO2 capture and sequestration in saline formations. The analysis includes two biomass supply scenarios (near-term and long-term), two biomass logistics scenarios (conventional and pelletized), and two generation technologies (pulverized combustion and integrated gasification combined cycle). Results show marginal cost per tonne CO2 (accounting for costs of electricity and CO2 emissions of reference power generation scenarios) as a function of CO2 sequestered (simulating capture of up to 90% of total CO2 sequestration potential) and associated spatial distribution of resources and generation locations for the array of scenario options. Under a near-term scenario using up to 206 million tonnes per year of biomass, up to 181 million tonnes CO2 can be sequestered annually at scenario-average costs ranging from $62 to $137 per tonne CO2; under a long-term scenario using up to 740 million tonnes per year of biomass, up to 737 million tonnes CO2 can be sequestered annually at scenario-average costs ranging from $42 to $92 per tonne CO2. These estimates of CO2 sequestration potential may be reduced if future competing demand reduces resource availability or may be increased if displaced emissions from conventional power sources are included. Results suggest there are large-scale opportunities to implement BECCS at moderate cost in the US, particularly in the Midwest, Plains States, and Texas.

09 BIOMASS FUELS↗

Use of the Hugoniot Elastic Limit in Laser Shockwave Experiments to Relate Velocity Measurements

---The Idaho National Laboratory (INL) has been developing a Laser Shock system to characterize interface strength in plate fuel for research reactors around the world [1]. This work is in support of the Unites states High Performance Research Reactor program whose goal is to reduce the risk of proliferation of weapons grade fuel while maintaining reactor performance. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. ---One of the concerns of the project is the difficulty of calibrating and standardizing the laser shock technique. The generation of the stress wave by the laser impinging on the plate surface is complex, with amplitude and shape dependence on numerous factors relating to the temporal and spatial distribution of power in the laser spot, surface treatment, and material properties of the plate. Thus the resulting back-face surface velocity, which is used to measure the time-varying stress field within the plate, is difficult to reproduce across different measurement systems. A technique that can generate or indicate a known shock intensity independent of the generating conditions would be valuable and allow us to directly compare results from different systems. ---A Laser Shock round robin test between the system at NRC and the INL was conducted. The goal of the round robin was to determine if there was any bias between the two systems. During the analysis of the data, it was noted that the Hugoniot Elastic Limit (HEL) was consistent within both system data sets independent of the laser power used. An analytical study under development supports that the HEL in metals could be a robust and simple benchmark to compare stresses generated by different laser shock systems. The HEL is a material property that should be insensitive to differences in the shock laser and surface preparation which enhances the reliability of the resulting HEL velocity measurement. 1. J. M. Lacy, J. A. Smith and B. H. Rabin, "Developing a Laser Shockwave Model for Characterizing Diffusion Bonded Interfaces," The 41st Annual Review of Progress in Quantitative Nondestructive Evaluation," Boise, ID, U.S.A., July 2014.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimal Regulation of Virtual Power Plants

This paper develops a real-time algorithmic framework for aggregations of distributed energy resources (DERs) in distribution networks to provide regulation services in response to transmission-level requests. Leveraging online primal-dual-type methods for time-varying optimization problems and suitable linearizations of the nonlinear AC power-flow equations, we believe this work establishes the system-theoretic foundation to realize the vision of distribution-level virtual power plants. The optimization framework controls the output powers of dispatchable DERs such that, in aggregate, they respond to automatic-generation-control and/or regulation-services commands. This is achieved while concurrently regulating voltages within the feeder and maximizing customers' and utility's performance objectives. Convergence and tracking capabilities are analytically established under suitable modeling assumptions. Simulations are provided to validate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Megawatt-Scale Power-Hardware-in-the-Loop Interface for Testing Ancillary Grid Services by Converter-Coupled Generation

Power-hardware-in-the-loop (PHIL) is a simulation tool that can support electrical systems engineers in the development and experimental validation of novel, advanced control schemes that ensure the robustness and resiliency of electrical grids that have high penetrations of low-inertia variable renewable resources. With PHIL, the impact of the device under test on a generation or distribution system can be analyzed using a real-time simulator (RTS). PHIL allows for the interconnection of the RTS with a 7 megavolt ampere (MVA) power amplifier to test multi-megawatt renewable assets available at the National Wind Technology Center (NWTC). This paper addresses issues related to the development of a PHIL interface that allows testing hardware devices at actual scale. In particular, the novel PHIL interface algorithm and high-speed digital interface, which minimize the critical loop delay, are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Megawatt-Scale Power-Hardware-in-the-Loop Interface for Testing Ancillary Grid Services by Converter-Coupled Generation: Preprint

Power-hardware-in-the-loop (PHIL) is a simulation tool that can support electrical systems engineers in the development and experimental validation of novel, advanced control schemes that ensure the robustness and resiliency of electrical grids that have high penetrations of low-inertia variable renewable resources. With PHIL, the impact of the device under test on a generation or distribution system can be analyzed using a real-time simulator (RTS). PHIL allows for the interconnection of the RTS with a 7 megavolt ampere (MVA) power amplifier to test multi-megawatt renewable assets available at the National Wind Technology Center (NWTC). This paper addresses issues related to the development of a PHIL interface that allows testing hardware devices at actual scale. In particular, the novel PHIL interface algorithm and high-speed digital interface, which minimize the critical loop delay, are discussed.

17 WIND ENERGY↗

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Integrated Smart Distribution RD&D Project Final Technical Report

Title XIII of the Energy Independence and Security Act of 2007 (EISA), tasked OE with accelerating the commercialization, deployment and integration of advanced digital systems that are needed to modernize the nation’s electricity delivery network for enhanced interoperability and cyber security. To support this mandated task, a goal of the SGR&D Program is to develop technology with the ability to dynamically optimize grid operations and resources and incorporate demand response and consumer participation. The majority of historical research and development in the domain of distribution management systems (DMS) had focused on classical, radial and passive networks with one-way power flow from transmission to distribution systems and thus to the end customer. With the focus on customers, a bottom-up approach required a completely new thinking in real-time operations, and automation, of smart distribution systems. Thus, the GE team embarked on a project with a plan of two distinct phases. Work during the first phase concentrated on research and development (R&D) for the first three years. The second phase, lasting approximately two years, accomplished the demonstration of the use cases developed during the first phase, with further sharing and dissemination of the research at industry events. The consolidated technical scope of the project can be summarized into the following six areas: Advanced distribution modeling capability to accurately simulate/model smart grid operations. Accurate representation of the distribution system in real- or near real-time (capture real-time topology). Interoperability with, and seamless communication between, other management systems and databases used by the utility Simulation of distribution systems based on real-time operational planning to analyze the benefits of smart grid assets. Integration of network, market, and renewable resource models for next generation DMS. Management and forecasting of DER (Distributed Generation, Storage, Demand Response).

14 SOLAR ENERGY↗

Systematic Approach to Better Understanding Integration Costs

This research presents a systematic approach to evaluating the costs of integrating new generation and operational procedures into an existing power system, and the methodology is independent of the type of change or nature of the generation. The work was commissioned by the U.S. Department of Energy and performed by the National Renewable Energy Laboratory to investigate three integration cost-related questions: (1) How does the addition of new generation affect a system's operational costs, (2) How do generation mix and operating parameters and procedures affect costs, and (3) How does the amount of variable generation (non-dispatchable wind and solar) impact the accuracy of natural gas orders? A detailed operational analysis was performed for seven sets of experiments: variable generation, large conventional generation, generation mix, gas prices, fast-start generation, self-scheduling, and gas supply constraints. For each experiment, four components of integration costs were examined: cycling costs, non-cycling VO&M costs, fuel costs, and reserves provisioning costs. The investigation was conducted with PLEXOS production cost modeling software utilizing an updated version of the Institute of Electrical and Electronics Engineers 118-bus test system overlaid with projected operating loads from the Western Electricity Coordinating Council for the Sacramento Municipal Utility District, Puget Sound Energy, and Public Service Colorado in the year 2020. The test system was selected in consultation with an industry-based technical review committee to be a reasonable approximation of an interconnection yet small enough to allow the research team to investigate a large number of scenarios and sensitivity combinations. The research should prove useful to market designers, regulators, utilities, and others who want to better understand how system changes can affect production costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring and control requirement definition study for Dispersed Storage and Generation (DSG). Volume 4, appendix C: Identification from utility visits of present and future approaches to integration of DSG into distribution networks

Visits to four utilities concerned with the use of DSG power sources on their distribution networks yielded useful impressions of present and future approaches to the integration of DSGs into electrical distribution network. Different approaches to future utility systems with DSG are beginning to take shape. The new DSG sources will be in decentralized locations with some measure of centralized control. The utilities have yet to establish firmly the communication and control means or their organization. For the present, the means for integrating the DSGs and their associated monitoring and control equipment into a unified system have not been decided.

Source record↗

Smart DG Hub Resilient Solar Project Final Report

Hurricanes, unstable fossil fuel supplies and increased energy loads have revealed the vulnerability of America’s electric grids. Renewable energy has emerged as a viable option; however in order for this sector to reach its full potential it needs to be paired with storage. For example, all of the solar installations in New York City in 2014 were wired to automatically shut down during grid outages for safety reasons and lacked battery backup or other means to function during outages. Pairing solar with batteries can provide critical power needs and reduce dependency on delivered fuel. Additionally, resilient solar systems can also provide benefits outside of emergencies such as utility bill savings and grid support services. Solar+Storage needed a pathway through regulatory, policy and financial hurdles, some of which are unique to urban environments. Sustainable CUNY of the City University of New York (CUNY) formed the Smart Distributed Generation (DG) Hub to develop a strategic pathway to a resilient distributed energy system that integrates storage into resiliency planning and provide support to the grid on peak power days. Through the Smart DG Hub Resilient Solar Project, with support from the U.S. Department of Energy (DOE) as well as the New York State Energy Research and Development Authority, the New York Power Authority and private funding, Sustainable CUNY worked with project partners - including the National Renewable Energy Laboratory, Meister Consultant Group (now Cadmus), subject matter experts at utility companies, and authorities having jurisdiction - to develop a roadmap for the greater deployment of solar+storage as well as a toolkit of resources. Ultimately, in addition to the completed deliverables of multiple resources, the project established a baseline of the current policy, financial, and market landscape, and an understanding of which key areas would require further actions. The DG Hub’s collaborative platform and subject matter expertise gained through this project led directly to a new award from the NYS Energy Research & Development Authority to continue CUNY’s work in targeted areas including energy storage permitting and stakeholder education, similar to the way DOE’s prior support had sowed the initial seeds for the growth of the solar market in NYC, to the NYS market. Finally, the Resilient Solar Project helped inform the New York City (NYC) administration, leading to a significant policy development that included Mayor Bill de Blasio setting a city-wide storage goal of 100 MW by 2020, the first of any city in the country.

25 ENERGY STORAGE↗

PacWave Grid Integration Study: Transient and Dynamic Conditions (Final Report)

This report describes the results of PSCAD simulations that were performed in 2020 to assess the impacts of PacWave generation on CLPUD's 12.47-kV distribution and 69-kV subtransmission systems. PacWave South (PacWave) is a wave energy test facility planned by Oregon State University. PacWave shore facilities will be located south of Seal Rock on the Oregon coast. PacWave is expected to be operational in 2022 and will connect up to 10 MW of generation to CLPUD's Seal Rock distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Military markets for solar thermal electric power systems

The Department of Defense maintains an inventory of over 1,800 MW of engine-generators 15 KW and larger, with an estimated procurement rate of over 140 MW/year. Nearly the entire requirement could be met by advanced heat engines of the types being developed as point-focussing, distributed receiver power plants. A conceptual system consisting of a heat engine which efficiently burns liquid fossil or synthetic fuels, with a 'solarization kit' for conversion to hybrid solar operation could meet existing DOD requirements for new systems which are quieter, lighter, and multi-fueled. An estimated 24 percent (33 MW/year) or more could operationally benefit from the solar option. Baseline cost projections indicate levelized energy cost goals of 210 to 120 mills/KWh (15 to 1000 KW systems). Fuel cost escalation is the major factor affecting the value of the solar option. A baseline calculation for fuel at $0.59/gal in spring, 1979, escalating at 8 percent above general inflation indicates a value of $2700/KWe for a solarization kit.

Hauger, J. S.↗

Probabilistic Voltage Sensitivity Analysis to Quantify Impact of High PV Penetration on Unbalanced Distribution System

From an operational and planning perspective, it is important to quantify the impact of increasing penetration of photovoltaics on the distribution system. Most existing impact assessment studies are scenario-based where derived results are scenario specific and not generalizable. Moreover, stochasticity in the temporal behavior of spatially distributed PVs requires a large number of scenarios that increase with the size of the network and the level of penetration. Therefore, we propose a new computationally efficient analytical framework of voltage sensitivity analysis that allows for stochastic analysis of voltage change due to random changes in PV generation. We first derive an analytical approximation for voltage change at any node of the network due to change in power at other nodes in an unbalanced distribution network. The quality of this approximation is reinforced via bounds on the approximation error. Then, we derive the probability distribution of voltage change at a certain node due to random changes in power injections/consumptions at multiple locations of the network. The accuracy of the proposed PVSA is illustrated using a modified version of the IEEE 37 bus test system. As a result, the proposed PVSA can serve as a powerful tool for proactive monitoring/control and ease the computational burden associated with perturbation based cybersecurity mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗