Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Status Report on the Passive Neutron Enrichment Meter (PNEM) for UF 6 Cylinder Assay

The Passive Neutron Enrichment Meter (PNEM) is a nondestructive assay (NDA) system being developed at Los Alamos National Laboratory (LANL). It was designed to determine 235 U mass and enrichment of uranium hexafluoride (UF 6 ) in product, feed, and tails cylinders (i.e., 30B and 48Y cylinders). These cylinders are found in the nuclear fuel cycle at uranium conversion, enrichment, and fuel fabrication facilities. The PNEM is a 3 He-based neutron detection system that consists of two briefcase-sized detector pods. A photograph of the system during characterization at LANL is shown in Fig. 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High spatial resolution thermal conductivity mapping of SiC/SiC composites

Herein, silicon carbide (SiC) ceramic matrix composites are being investigated as a new generation of fuel cladding materials due to its higher accident tolerance compared to Zircaloy. Characterization of the thermal conductivity of SiC constituents and their interfaces and interphases in SiC/SiC composites is needed as inputs to models of cladding performance. We used time-domain thermoreflectance (TDTR) to map the thermal conductivity with a spatial resolution of 2 µm. The SiC/SiC composite is comprised of Hi-Nicalon Type S fibers in a matrix made by chemical vapor infiltration (CVI matrix). The interphase material is a pyrolytic carbon/SiC multilayer. We report thermal conductivity maps of the SiC fiber and SiC matrix at temperatures of 25 °C, 90 °C, 164 °C, and 250 °C. The fiber has a uniform and isotropic thermal conductivity of 22 W m -1 K -1 at 25 °C; the thermal conductivity of fiber is approximately independent of temperature. The matrix thermal conductivity is not uniform and varies from 50 to 120 W m -1 K -1 at 25 °C; the thermal conductivity of the matrix scales approximately with the inverse of the square root of temperature, i.e., ∝ 1/T 1/2 . The thermal conductivity of the interphase at room temperature is 6 W m -1 K -1 . The calculated spatially averaged thermal conductivity of this SiC/SiC composite at 1000°C is 29 W m -1 K -1 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and operation in magnetic field of CMS GE1/1 station

In October and November 2021 the CMS Gas Electron Multiplier (GEM) detectors of station GE1/1 were operated for the first time in presence of a magnetic field in CMS. The phenomena observed in this first period led to performing a test on GE1/1 chambers to study their behaviour in presence of a magnetic field ramp. The magnetic field has been created using the Goliath magnet installed in the CERN North Area. In conclusion, the aim of the test is to determine if a magnetic field ramp causes serious problems to the operation of the GEM chambers and to develop a clear set of procedures, that will permit the safe operations of the GEM chambers during a magnetic field ramp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard-photon-triggered jets in 𝑝−𝑝 and 𝐴−𝐴 collisions

An investigation of high-transverse-momentum (high-𝑝 𝑇 ) photon-triggered jets in proton-proton (𝑝−𝑝) and ion-ion (𝐴−𝐴) collisions at $\sqrt{s_{NN}}$=0.2 and 5.02TeV is carried out, using the multistage description of in-medium jet evolution. Monte Carlo simulations of hard scattering and energy loss in heavy-ion collisions are performed using parameters tuned in a previous study of the nuclear modification factor (𝑅 𝐴⁢𝐴 ) for inclusive jets and high-𝑝𝑇 hadrons. We obtain a good reproduction of the experimental data for photon-triggered jet 𝑅 𝐴⁢𝐴 , as measured by the ATLAS detector, the distribution of the ratio of jet to photon 𝑝 𝑇 (𝑋 𝐽⁢𝛾 ), measured by both CMS and ATLAS, and the photon-jet azimuthal correlation as measured by CMS. We obtain a moderate description of the photon-triggered jet 𝐼 𝐴⁢𝐴 , as measured by STAR. A noticeable improvement in the comparison is observed when one goes beyond prompt photons and includes bremsstrahlung and decay photons, revealing their significance in certain kinematic regions, particularly at 𝑋 𝐽⁢𝛾 >1. Moreover, azimuthal angle correlations demonstrate a notable impact of bremsstrahlung photons on the distribution, emphasizing their role in accurately describing experimental results. This work highlights the success of the multistage model of jet modification to straightforwardly predict (this set of) photon-triggered jet observables. This comparison, along with the role played by bremsstrahlung photons, has important consequences on the inclusion of such observables in a future Bayesian analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Evaluation of Light-Element Reactions in the Resolved Resonance Region

Light-element reactions at low energies in the resolved resonance region are important for a range of applications in basic and applied sciences including nuclear reactors, nonproliferation, cultural heritage, forensics and environmental control, rare event investigations and nuclear astrophysics. In this paper, we report on an effort to evaluate charged-particle cross sections in the resolved resonance region and produce evaluated nuclear data files for further processing and inclusion in evaluated data libraries. We discuss the open issues in R-matrix calculations as we extend to higher energies, such as dealing with the rapidly growing number of open channels and merging with the regime of smooth cross sections described by the statistical model, and present attempts to address these issues in neutron-induced reactions relevant to nuclear reactor applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deuterated-xylene (xylene-d 10 ; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. x 3 in. deuterated-xylene organic liquid scintillator (C 8 D 10 ; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C 6 D 6 ; NE230, BC537, and E1315) this scintillator can provide good pulse shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene -based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition E1301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light -response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective ( x 10 to x 100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. Here, as we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse -selected beam (as needed for time-of-flight) is not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototyping an active neutron veto for SuperCDMS

Neutrons, originating cosmogenically or from radioactive decays, can produce signals in dark matter detectors that are indistinguishable from Weakly Interacting Massive Particles (WIMPs). To combat this background for the SuperCDMS SNOLAB experiment, we are investigating designs for an active neutron veto within the constrained space of the compact SuperCDMS passive shielding. The current design employs an organic liquid scintillator mixed with an agent to enhance thermal neutron captures, with the scintillation light collected using wavelength-shifting fibers and read out by silicon photo-multipliers. We will describe the proposed veto and its predicted efficiency in detail and give some recent results from our R&D and prototyping efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode

The Microhexcavity Panel (μHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The μHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate (> 100KHz / cm 2 ) capability. The devices reported here were fabricated as 16 × 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass–ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 μm diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both βs from radioactive sources and to cosmic ray muons. Finally, continuous avalanche mode operation over several days at hit rates over 300 KHz / cm 2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗