Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Expanding standards in viromics: in silico evaluation of dsDNA viral genome identification, classification, and auxiliary metabolic gene curation

Viruses influence global patterns of microbial diversity and nutrient cycles. Though viral metagenomics (viromics), specifically targeting dsDNA viruses, has been critical for revealing viral roles across diverse ecosystems, its analyses differ in many ways from those used for microbes. To date, viromics benchmarking has covered read pre-processing, assembly, relative abundance, read mapping thresholds and diversity estimation, but other steps would benefit from benchmarking and standardization. Here we use in silico-generated datasets and an extensive literature survey to evaluate and highlight how dataset composition (i.e., viromes vs bulk metagenomes) and assembly fragmentation impact (i) viral contig identification tool, (ii) virus taxonomic classification, and (iii) identification and curation of auxiliary metabolic genes (AMGs). The in silico benchmarking of five commonly used virus identification tools show that gene-content-based tools consistently performed well for long (≥3 kbp) contigs, while k -mer- and blast-based tools were uniquely able to detect viruses from short (≤3 kbp) contigs. Notably, however, the performance increase of k -mer- and blast-based tools for short contigs was obtained at the cost of increased false positives (sometimes up to ~5% for virome and ~75% bulk samples), particularly when eukaryotic or mobile genetic element sequences were included in the test datasets. Furthermore, for viral classification, variously sized genome fragments were assessed using gene-sharing network analytics to quantify drop-offs in taxonomic assignments, which revealed correct assignations ranging from ~95% (whole genomes) down to ~80% (3 kbp sized genome fragments). A similar trend was also observed for other viral classification tools such as VPF-class, ViPTree and VIRIDIC, suggesting that caution is warranted when classifying short genome fragments and not full genomes. Finally, we highlight how fragmented assemblies can lead to erroneous identification of AMGs and outline a best-practices workflow to curate candidate AMGs in viral genomes assembled from metagenomes. Together, these benchmarking experiments and annotation guidelines should aid researchers seeking to best detect, classify, and characterize the myriad viruses ‘hidden’ in diverse sequence datasets.

59 BASIC BIOLOGICAL SCIENCES↗

FOCUS: an alignment-free model to identify organisms in metagenomes using non-negative least squares

One of the major goals in metagenomics is to identify the organisms present in a microbial community from unannotated shotgun sequencing reads. Taxonomic profiling has valuable applications in biological and medical research, including disease diagnostics. Most currently available approaches do not scale well with increasing data volumes, which is important because both the number and lengths of the reads provided by sequencing platforms keep increasing. Here we introduce FOCUS, an agile composition based approach using non-negative least squares (NNLS) to report the organisms present in metagenomic samples and profile their abundances. FOCUS was tested with simulated and real metagenomes, and the results show that our approach accurately predicts the organisms present in microbial communities. FOCUS was implemented in Python. The source code and web-sever are freely available at http://edwards.sdsu.edu/FOCUS.

59 BASIC BIOLOGICAL SCIENCES↗

Budding yeasts in the subphylum Saccharomycotina Genome sequencing and assembly

Eukaryotic life depends on the functional elements encoded by both the nuclear genome and organellar genomes, such as those contained within the mitochondria. The content, size, and structure of the mitochondrial genome varies across organisms with potentially large implications for phenotypic variance and resulting evolutionary trajectories. Among yeasts in the subphylum Saccharomycotina, extensive differences have been observed in various species relative to the model yeast Saccharomyces cerevisiae, but mitochondrial genome sampling across many groups has been scarce, even as hundreds of nuclear genomes have become available. By extracting mitochondrial reads from existing short-read genome sequence datasets, we have greatly expanded both the number of available genomes and the coverage across sparsely sampled clades. Comparison of 353 yeast mitochondrial genomes revealed that, while size and GC content were fairly consistent across species, those in the genera Metschnikowia and Saccharomyces trended larger, while several species in the order Saccharomycetales exhibited lower GC content. Extreme examples for both size and GC content were scattered throughout the subphylum. All mitochondrial genomes shared a core set of protein-coding genes for Complexes III, IV, and V, but they varied in the presence or absence of mitochondrially-encoded canonical Complex I genes. We traced the loss of Complex I genes to a major event in the ancestor of the orders Saccharomycetales and Saccharomycodales, but we also observed several independent losses in the orders Phaffomycetales, Pichiales, and Dipodascales. In contrast to prior hypotheses based on smaller-scale datasets, comparison of evolutionary rates in protein-coding genes showed no bias towards elevated rates among aerobically fermenting (Crabtree/Warburg-positive) yeasts. Mitochondrial introns were widely distributed, but highly enriched in some groups. The majority of mitochondrial introns were poorly conserved within groups, but several were shared within groups, between groups, and even across taxonomic orders, which is consistent with horizontal gene transfer, likely involving homing endonucleases acting as selfish elements. As the number of available fungal nuclear genomes continues to expand, the methods described here to retrieve mitochondrial genome sequences from these datasets will prove invaluable to ensuring that studies of fungal mitochondrial genomes keep pace with their nuclear counterparts.

diversity↗

Compact cartridge drives coded tape at constant readout speed

To facilitate storage and repetitive reading of short-program coded tape, a cartridge case, containing mechanical drive and readout assemblies, has been fabricated. The drive transports the tape past a conventional pickup device during the reading function.

Austin, D. C.↗

Nonvolatile read/write memory element - A concept

Bidirectional MOS driver, integrated with diode matrix reduces fuse read current to only that of junction leakage and transient MOS gate charging current. No current, except junction leakage current, flows in unaddressed cells. Current required to drive MOS gate flows through unfused branch only during read mode.

Cricchi, J. R.↗

Automatic control of liquid cooling garment by cutaneous and external auditory meatus temperatures

An automatic control apparatus for a liquid cooling garment is described that is responsive to actual physiological needs during work and rest periods of a man clothed in the liquid cooling garment. Four skin temperature readings and a reading taken at the external portion of the auditory meatus are added and used in the control signal for a temperature control valve regulating inlet water temperature for the liquid cooling garment. The control apparatus comprises electronic circuits to which the temperatures are applied as control signals and an electro-pneumatic transducer attached to the control valve.

Fulcher, C. W. G.↗

Coordination and establishment of centralized facilities and services for the University of Alaska ERTS survey of the Alaskan environment

The author has identified the following significant results. Specifications have been prepared for the engineering design and construction of a digital color display unit which will be used for automatic processing of ERTS data. The color display unit is a disk refresh memory with computer interfaced input and a color cathode ray tube output display. The system features both analog and digital post disk data manipulation and a versatile color coding device suitable for displaying not only images, but also computer generated graphics such as diagrams, maps, and overlays. Input is from IBM compatible 9 track, 800 BPI tapes, as generated by an IBM 360 computer. ERTS digital tapes are read into the 360, where various analyses such as maximum likelihood classification are performed and the results are written on a magnetic tape which is the input to the color display unit. The greatest versatility in the data manipulation area is provided by the minicomputer built into the color display unit, which is off-line from the main 360 computer. The minicomputer is able to read any line from the refresh disk and place it in its 4K-16 bit memory. Considerable flexibility is available for post-processing enhancement of images by the investigator.

Belon, A. E.↗

Binary concatenated coding system

Coding, using 3-bit binary words, is applicable to any measurement having integer scale up to 100. System using 6-bit data words can be expanded to read from 1 to 10,000, and 9-bit data words can increase range to 1,000,000. Code may be ''read'' directly by observation after memorizing simple listing of 9's and 10's.

Monford, L. G., Jr.↗

A fluidic device for measuring constituent masses of a flowing binary gas mixture

A continuous reading mass flow device was developed to measure the component flow of a binary gas mixture. The basic components of the device are a fluidic humidity sensor and a specially designed flow calorimeter. These components provide readings of gas mixture ratio, mixture heat capacity, heat dissipated by the calorimeter and the gas temperature rise across the calorimeter. These parameter values, applied in the general definitions of specific heat capacity and the heat capacity of a gas mixture, produce calculated component flow rates of the mixture being metered. A test program was conducted to evaluate both the steady state and dynamic performance of the device.

Prokopius, P. R.↗

Optical memory development. Volume 1: prototype memory system

The design, development, and implementation of a prototype, partially populated, million bit read-write holographic memory system using state-of-the-art components are described. The system employs an argon ion laser, acoustooptic beam deflectors, a holographic beam splitter (hololens), a nematic liquid crystal page composer, a photoconductor-thermoplastic erasable storage medium, a silicon P-I-N photodiode array, with lenses and electronics of both conventional and custom design. Operation of the prototype memory system was successfully demonstrated. Careful attention is given to the analysis from which the design criteria were developed. Specifications for the major components are listed, along with the details of their construction and performance. The primary conclusion resulting from this program is that the basic principles of read-write holographic memory system are well understood and are reducible to practice.

Cosentino, L. S.↗

Facilitating the exploitation of ERTS imagery using snow enhancement techniques

The author has identified the following significant results. New fracture detail within New England test area has been interpreted from ERTS-1 images. Comparative analysis of snow-free imagery (1096-15065 and 1096-15072) has demonstrated that MSS bands 5 and 7 supply the greatest amount of geological fracture detail. Interpretation of the first snow-covered ERTS-1 images (1132-15074 and 1168-15065) in correlation with ground snow depth data indicates that a heavy blanket of snow (less than 9 inches) accentuates major structural features while a light dusting (greater than 1 inch) accentuates more subtle topographic expressions. Snow cover was found to accentuate drainage patterns which are indicative of lithological and/or structural variations. Snow cover provided added enhancement for viewing and detecting topographically expressed fractures and faults. A recent field investigation was conducted within the New England test area to field check lineaments observed from analysis of ERTS-1 imagery, collect snow depth readings, and obtain structural joint readings at key locations in the test area.

Wobber, F. J.↗

Cathodochromic cathode ray tube: An operations manual

A cathodochromic (CC) storage and display system capable of storing full TV resolution images has been built. The images are derived from standard TV signals: composite video, composite sync, composite blanking, horizontal drive, and vertical drive. Image storage takes place in the CC CRT; the fixed image is written for several TV frames for the contrast to be usable. Once stored on the CC CRT, the image can be read out in one of three modes: with the eye, a 35-mm camera, or a TV camera. Incoming information may also be stored in a storage tube similar to the CC CRT but with a phosphor layer behind the CC layer. By exciting the phosphor layer with a standard raster scan it is possible to read out an image stored in the CC layer in one of three modes: direct viewing, photography, or flying-spot readout using a photomultiplier.

Heyman, P. M.↗

The V-3 contamination test of the chamber A facility and a subsequent cryogenic/vacuum study of the V-3 test quartz crystal microbalance

The areas of orbital and ground contamination of flight experiment hardware have been well established. This report relates directly to results of vacuum chamber testing for the ground evaluation of flight experiment hardware performance. First, the data obtained during the V-3 contamination testing in the Johnson Space Center's Chamber A space simulation test facility are presented. Second, during the V-3 contamination tests, the MSFC Space Sciences Laboratory's quartz crystal microbalance exhibited two periods of anomalous readings. Therefore, a subsequent small chamber tests was conducted in a controlled cryogenic/vacuum environment. The objective was to reproduce with known parameters the anomalous behavior patterns of the V-3 test data. Analyses of the anomalous readings are made on the basis of these tests. Additionally, as a by-product of the small chamber tests, calibration curves then existing for the quartz crystal microbalance were empirically extended, and certain data-formatting aids were documented.

Moore, W. W., Jr.↗

Image data rate converter having a drum with a fixed head and a rotatable head

A data-rate converter is disclosed comprising a rotatable data-storing drum with at least one fixed read/record head and a rotatable read/record head. The latter is rotatable in a circular path about the drum axis of rotation. The drum is positionable in any one of a plurality of axial positions with respect to the heads, so that at least one drum track is aligned with the fixed head in one drum position and with the rotatable head in another drum position. When a track is aligned with the fixed head, data may be recorded therin or read out therefrom at a rate which is a function of drum rotation, while when aligned with the rotatable head, data may be recorded or read out at a rate which is a function of the rates and directions of rotation of both the drum and the head.

Billingsley, F. C.↗

Remote measurement of turbidity and chlorophyll through aerial photography

Studies were conducted utilizing six different film and filter combinations to quantitatively detect chlorophyll and turbidity in six farm ponds. The low range of turbidity from 0-35 JTU correlated well with the density readings from the green band of normal color film and the high range above 35 JTU was found to correlate with density readings in the red band of color infrared film. The effect of many of the significant variables can be reduced by using standardized procedures in taking the photography. Attempts to detect chlorophyll were masked by the turbidity. The ponds which were highly turbid also had high chlorophyll concentrations; whereas, the ponds with low turbidity also had low chlorophyll concentrations. This prevented a direct correlation for this parameter. Several suggested approaches are cited for possible future investigations.

Schwebel, M. D.↗

Experimental transient vane temperatures in a cascade for gas stream temperature cycling between 922 and 1644 K (1200 and 2500 F)

Experimental transient turbine vane metal temperatures were obtained from tests conducted on air-cooled vanes installed in a four-vane cascade for a gas temperature cycled between 922 and 1644 K (1200 and 2500 F). Transient data were recorded by a high-speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 11 kelvins (20 F), simulated cruise and idle steady-state readings were repeated by the cruise and idle readings taken from the ends of a transient half-cycle at low pressure to within 17 kelvins (30 F). The tests were conducted at pressure levels of 31 and 83 N-sq cm (45 and 120 psia) with coolant temperatures of 811 and 589 K (1000 and 600 F), respectively.

Gauntner, D. J.↗

Plant size, etc., and aerial films

Chlorophyll concentration of chlorotic leaves, expressed as milligrams of chlorophyll per cubic centimeter of leaf volume, was positively correlated to film density readings. Images on the film became darker as chlorophyll concentration increased. Plant size was not related to density readings.

Gausman, H.↗