Search NASASearch

SEARCH · Search NASA

Results for “Turbine Engine Test Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,292 records · Page 69

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped

Remote Sensing-Driven Hydrodynamic Modeling in Data-Scarce Regions: Integrating ICESat-2, Sentinel-2, SWOT and Re-analysis Models for Coastal Monitoring

Hydrodynamic models in coastal and estuarine systems are typically constrained by sparse bathymetry, boundary, and validation data, especially in regions where field campaigns are costly or impractical. Here we develop and test a fully satellite-driven framework for hydrodynamic modeling in South Africa’s Langebaan Lagoon without using any local in situ measurements. Bathymetry is derived by training multispectral Sentinel-2 reflectance against ICESat-2 ATL24 photon-derived depths using an XGBoost model optimized with Bayesian search. The final satellite-derived bathymetry reproduces independent ATL24 points with RMSE = 0.45 m and R 2 = 0.97. This bathymetry was used in a depth-averaged Delft3D Flexible Mesh model driven at the open boundary by TPXO tidal harmonics and by ERA5 winds. We validate modeled water surface elevation against 16 SWOT low-rate (250 m, unsmoothed) passes in 2023. SWOT–model comparisons yield an overall RMSE of 0.11 m and R 2 = 0.61, with typical point differences <0.10 m (∼7% of the 1.5 m tidal range), and showed consistent spatial gradients in water level from the offshore boundary, through Saldanha Bay, and into the lagoon. At the offshore boundary, TPXO and SWOT sea surface heights agree closely (R 2 = 0.86). A simple phase adjustment of ∼26,min between TPXO and SWOT lowers the RMSE from 0.18,m to 0.11,m, showing that phase offset accounts for some of the discrepancy, with additional errors likely linked to non-tidal signals. Our results demonstrate that combining passive optical, photon-counting LiDAR, radar interferometry, and global tidal/atmospheric models enables robust, transferrable hydrodynamic modeling in data-scarce coastal systems, offering a cost-effective pathway for monitoring.

ICESat-2

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE

Interaction of Soil pH and Mineralogy Controls Soil Organic Matter Persistence through Changes in the Composition and Amount of Microbial Necromass

Microbial necromass–mineral associations are key to long-term soil organic matter (SOM) persistence. However, how soil pH and mineralogy interact to regulate SOM stability remains poorly understood. Here, we used artificial soils to test how three clay minerals (bentonite, kaolinite, and goethite), adjusted to four pH levels (5–8), affect microbial activity (respiration), microbial physiology (carbon use efficiency, CUE), microbial-derived residue material (necromass), and the formation and stability of mineral-associated organic matter (MAOM). Artificial soils were inoculated with a rhizosphere-derived microbial community cultured under the same pH conditions and on two representative simulated exudate types (organic acids and carbohydrates) and incubated for 6 weeks. In two complementary experiments, we added necromass from known microbial taxa to the same minerals across pH levels to isolate the role of necromass chemistry and loading. We found that soil pH shaped MAOM chemistry by altering microbial activity and necromass composition. In interaction with mineral type, pH also controlled MAOM thermal stability. Higher necromass loading weakened mineral-organic bonding, reducing MAOM stability, consistent with zonal mineral–organic interaction models. Our results demonstrate that microbial activity, rather than carbon use efficiency, better predicts MAOM formation and that pH-dependent necromass composition and loading govern MAOM persistence. These findings advance mechanistic understanding of SOM stabilization and have implications for predicting soil carbon dynamics under shifting environmental conditions.

carbon use efficiency

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health

The Shape Effect: Influence of 1D and 2D Boron Nitride Nanostructures on the Radiation Shielding, Thermal, and Damping Properties of High-Temperature Epoxy Composites

In space exploration, lightweight multifunctional materials capable of shielding neutron radiation, dissipating heat, and providing damping are essential. Polymer composites reinforced with boron nitride (BN) nanomaterials—specifically one-dimensional boron nitride nanotubes (BNNTs) and two-dimensional boron nitride nanoplatelets (BNNPs)—offer promising solutions. This study investigates how BN nanomaterial morphology influences the performance of high-temperature (HT) epoxy composites. We developed ultralightweight, three-dimensional BN foams comprising 1D BNNTs, 2D BNNPs, and hybrid 1D BNNT/2D BNNP structures via freeze-drying, then infiltrated them with HT epoxy to form dense composites. The BNNT foam exhibited the highest neutron radiation shielding, with a mass absorption coefficient of 26.64 cm2 g −1 , outperforming the hybrid foam (18.18 cm 2 g −1 ) and the BNNP foam (11.12 cm 2 g −1 ). A similar trend was observed in the HT epoxy composites; incorporating these foams at least doubled the mass absorption coefficient compared to the neat polymer. In terms of thermal conductivity, the BNNT/BNNP foam-epoxy composite achieved the highest value of 0.34 W m −1 K −1 , a 2.13-fold increase over neat HT epoxy. The BNNT/BNNP foam-epoxy composites also improved by 1.88 and 1.75 times, respectively. Mechanical testing revealed that BNNP foams withstood the highest loads during nanoindentation (3.53 kN), followed by BNNT/BNNP foams (1.93 kN) and BNNT foams (1.56 kN). All BN foam-epoxy composites exhibited enhanced damping properties, with tan δ increasing by at least 30 % compared to neat HT epoxy. These findings elucidate the impact of BN nanomaterial morphology on the multifunctional performance of HT epoxy composites, offering insights for developing high-performance, tailorable materials for demanding environments.

Kazue Orikasa

Identification of potent inhibitors of JUN N-terminal kinases for treatment of endometriosis and associated pain

Endometriosis, defined as the ectopic growth of endometrial tissue outside of the uterine cavity, is an inflammatory and hormone-dependent disease that causes excruciating pelvic pain, infertility, and significantly decreases quality of life in affected patients. The JUN N-terminal kinases (JNKs) are a leading class of nonhormonal therapeutic targets that have been validated in preclinical models of endometriosis and in a Phase 1/2 clinical trial. Despite their therapeutic potential, JNK inhibitors with increased potency and specificity are needed to address the inflammatory pathology of endometriosis and to prevent disease progression. Leveraging a DNA-encoded chemical library collection of ~4 billion compounds, we identified lead inhibitor CDD-2428 and optimized derivatives, CDD-2728 and CDD-3013, with excellent binding affinity to JNK1-3 (K d = 0.12 to 3.7 nM), enhanced selectivity, metabolic stability, and cellular permeability. Crystallographic and biochemical studies confirmed that CDD-3013 exhibited superior kinase selectivity with improved efficacy compared to existing JNK inhibitors. In primary endometriosis cell models, CDD-2728 and CDD-3013 suppressed JNK-dependent inflammatory signaling, dampening pathways linked to pain, invasion, angiogenesis, and macrophage recruitment. In an endometriosis mouse model, both CDD-2728 and CDD-3013 reduced endometriotic lesion size, macrophage infiltration, and cellular proliferation, showing in vivo efficacy. When tested in a lipopolysaccharide-induced hyperalgesia model, CDD-2728 and CDD-3013 decreased markers of induced pain, as measured by changes in a dynamic weight bearing test and Grimace scores. These findings nominate CDD-2728 and CDD-3013 as potent, nonhormonal therapeutic candidates for endometriosis with broad anti-inflammatory and analgesic activity, addressing a critical unmet clinical need.

Madasu, Chandrashekhar [Department of Pathology an

Spectrograph stabilization using a single-delay interferometer on the Hale Telescope

We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.

Erskine, David J [Lawrence Livermore National Labo

Revealing the Roles of CuF 2 /NiF 2 Incorporation in the Electrochemical Performance of FeF 3 Cathodes in Solid‐State Batteries

Mixed metal fluorides have been considered as a promising candidate to lower the voltage hysteresis of conversion-type iron fluoride cathodes, but their cycling stability is limited due to transition metal dissolution and interphase growth in liquid electrolyte batteries. Here, we study the role of incorporating CuF 2 and NiF 2 in the electrochemical performance of FeF 3 cathode in halide-based solid-state batteries to test whether we can transfer the kinetic benefit of low voltage hysteresis to solid-state batteries while using solid electrolyte to eliminate transition metal dissolution and stabilize the interphase. Synchrotron X-ray absorption spectroscopy results indicated the redox reactions are attributed to Cu 0 /Cu + and Fe 0 /Fe 2+ in 25CuF 2 -75FeF 3 and Ni 0 /Ni 2+ and Fe 0 /Fe 3+ in 10NiF 2 -90FeF 3 . While no apparent improvement in electrode kinetics can be observed, the incorporation of CuF 2 and NiF 2 can largely improve the cycling stability of FeF 3 cathodes. In conclusion, the results demonstrate the advantages of using solid-state concept to improve the cycling stability of conversion-type cathodes.

25 ENERGY STORAGE

Properties of a Ni19.5Pd30Ti50.5 High-Temperature Shape Memory Alloy in Tension and Compression

Potential applications involving high-temperature shape memory alloys have been growing in recent years. Even in those cases where promising new alloys have been identified, the knowledge base for such materials contains gaps crucial to their maturation and implementation in actuator and other applications. We begin to address this issue by characterizing the mechanical behavior of a Ni 19.5 Pd 30 Ti 50.5 high-temperature shape memory alloy in both uniaxial tension and compression at various temperatures. Differences in the isothermal uniaxial deformation behavior were most notable at test temperatures below the martensite finish temperature. The elastic modulus of the material was very dependent on strain level; therefore, dynamic Young’s Modulus was determined as a function of temperature by an impulse excitation technique. More importantly, the performance of a thermally activated actuator material is dependent on the work output of the alloy. Consequently, the strain-temperature response of the Ni 19.5 Pd 30 Ti 50.5 alloy under various loads was determined in both tension and compression and the specific work output calculated and compared in both loading conditions. It was found that the transformation strain and thus, the specific work output were similar regardless of the loading condition. Also, in both tension and compression, the strain-temperature loops determined under constant load conditions did not close due to the fact that the transformation strain during cooling was always larger than the transformation strain during heating. This was apparently the result of permanent plastic deformation of the martensite phase with each cycle. Consequently, before this alloy can be used under cyclic actuation conditions, modification of the microstructure or composition would be required to increase the resistance of the alloy to plastic deformation by slip.

High-Temperature Shape Memory Alloy

Dynamic nanodomains dictate macroscopic properties in lead halide perovskites

Lead halide perovskites have emerged as promising materials for solar energy conversion and X-ray detection owing to their remarkable optoelectronic properties. However, the microscopic origins of their superior performance remain unclear. Here we show that low-symmetry dynamic nanodomains present in the high-symmetry average cubic phases, whose characteristics are dictated by the A-site cation, govern the macroscopic behaviour. We combine X-ray diffuse scattering, inelastic neutron spectroscopy, hyperspectral photoluminescence microscopy and machine-learning-assisted molecular dynamics simulations to directly correlate local nanoscale dynamics with macroscopic optoelectronic response. Our approach reveals that methylammonium-based perovskites form densely packed, anisotropic dynamic nanodomains with out-of-phase octahedral tilting, whereas formamidinium-based systems develop sparse, isotropic, spherical nanodomains with in-phase tilting, even when crystallography reveals cubic symmetry on average. We demonstrate that these sparsely distributed isotropic nanodomains present in formamidinium-based systems reduce electronic dynamic disorder, resulting in a beneficial optoelectronic response, thereby enhancing the performance of formamidinium-based lead halide perovskite devices. By elucidating the influence of the A-site cation on local dynamic nanodomains, and consequently, on the macroscopic properties, we propose leveraging this relationship to engineer the optoelectronic response of these materials, propelling further advancements in perovskite-based photovoltaics, optoelectronics and X-ray imaging.

Materials Science

A review of nickel hydrogen battery technology

This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A NASA Lewis Research Center innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass, volume and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a reduction in manufacturing cost.

Smithrick, John J.

Transient histone deacetylase inhibition reveals cell type invariant and specific effects of chromatin decondensation on irradiation response

Radiation therapy plays a prominent role in breast cancer treatment, but the high doses of radiation damage both healthy and cancerous cells. Therefore, additional research is needed into combination therapies that could preferentially radiosensitize cancer cells compared to surrounding healthy tissue without causing deleterious side effects. Histone deacetylase inhibitor drugs (HDACis) have been tested as radiosensitizers in both basic research and clinical trials, but the long exposure time typically used in these treatments and the lack of matched healthy cell controls often leave aspects of their mechanism of action unclear. Here, we show that transient (2 h) trichostatin A (TSA) treatment of cancerous and non-tumorigenic breast epithelial cell lines increases immediate DNA damage and decreases long term cell viability in both cell types at high radiation doses. Transient TSA treatment also causes an increase in DNA damage signals after 5 Gy X-rays in other cancer and healthy cell types: A375 melanoma cells and BJ5-ta fibroblasts. This suggests that chromatin decompaction acts to increase cellular vulnerability to initial DNA damage from high doses of radiation in a cell type independent manner that does not rely on changes to DNA repair pathways caused by longer TSA treatment. However, responses to lower doses of radiation and long term survival are more cell type specific: only MCF7 cells experience an effect of TSA on DNA damage after 1 Gy X-ray radiation while MCF10a cells experience somewhat more evident cell viability effects of combined TSA and radiation treatment long term.

Li, Heng [Biochemistry & Cellular and Molecular Bi

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL

Multitask graph neural networks for elastoplastic response prediction in dual-phase polycrystals

Microstructure-sensitive prediction of elastoplastic response remains a recurring bottleneck in multiscale damage and fatigue modeling, where large ensembles of statistically distinct polycrystals are required to quantify variability and extreme-value behavior. In this work, we develop a multitask graph neural network (GNN) surrogate that maps dual-phase ferrite–martensite polycrystal microstructures to Statistical Volume Element (SVE)-level elastoplastic Quantities of Interest (QoIs). Each SVE is represented as a grain-adjacency graph, with node features encoding phase, geometry, and crystallographic orientation, and edge features encoding relative misorientation. A message-passing graph convolution generates node embeddings, which are pooled into a graph representation and passed to a multitask regression head that jointly predicts 10 scalar QoIs and vector-valued stress–strain responses in orthogonal loading directions across multiple martensite volume fractions and SVE sizes. Results show high accuracy for scalar QoIs and strong agreement for full stress–strain trajectories, with population envelopes reproducing both median behavior and finite-SVE variability across compositions and partition scales. A unified model trained on pooled volume-fraction data preserves most within-regime accuracy relative to regime-specific models while also capturing the broader cross-regime variation reflected in the pooled test set. Distributional comparisons further demonstrate that the surrogate preserves heterogeneity under SVE partitioning, enabling statistically consistent block-wise random-field construction for mesoscale analyses. Overall, the proposed grain-graph surrogate provides a practical pathway to accelerate ensemble-based studies of SVE-level constitutive variability in dual-phase polycrystals.

Crystal plasticity

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens

Development of an Additively Manufactured Subscale Secondary Sealed Container for the NASA FROSTE Project

This presentation details the development of an additively manufactured (AM) subscale test article for the secondary sealed container (SSC) as part of the NASA FROSTE project. FROSTE is focused on the collection of regolith samples from shadowed regions of the Moon and the preservation of those samples at cryogenic temperatures for return to Earth. Our team was integrated into the FROSTE program to leverage innovative design approaches and additive manufacturing capabilities in support of a scalable development strategy, where the subscale configuration serves as the development path toward a full-scale SSC. Scalmalloy was selected as the primary material for all AM components due to its favorable strength-to-weight ratio, thermal conductivity, and demonstrated performance in aerospace applications. Its aluminum-based composition supports robust mechanical behavior at cryogenic temperatures while enabling efficient heat transfer and control of thermal gradients within the containment system. The SSC architecture consists of an outer container assembly that houses a phase change material (PCM) tank, which in turn contains primary containers holding the regolith. Thermal management relies on controlled conductive and radiative heat transfer, including a thermal connection assembly that interfaces the PCM tank to an external cryocooler via a thermal strap, and IMLI surrounding the PCM tank to inhibit radiative heat transfer. The outer container assembly incorporates sealing interfaces, thermal connection ports, and I/O feedthroughs, with PTFE spring seals used at critical interfaces to maintain containment integrity. The PCM tank is manufactured as a single monolithic Scalmalloy component and incorporates an integral lattice structure to minimize thermal gradients, internal channels for thermocouple routing, and interface features for thermal connection assembly integration. The tank is centrally suspended within the outer container using support rings, with G10 insulating components employed to inhibit thermal leaks. This work describes the design methodology, AM approach, and key considerations used to inform the design.

regolith

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)