Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

History-dependent dissipative vortex dynamics in superconducting arrays

In this study, we perform current (I)-voltage (V) measurements on low resistance superconductor-normal-superconductor arrays in finite magnetic fields, focusing on the dilute vortex population regime. We observe significant deviations from predicted behavior, notably the absence of a differential resistance peak near the vortex depinning current, and a broad linear I-V region with an extrapolated I intercept equal to the depinning current. Comparing these results to an overdamped molecular vortex model, we find that this behavior can be explained by the presence of a history-dependent dissipative force. Lastly, this approach has not been considered previously, to our knowledge, yet it is crucial for obtaining a correct description of the vortex dynamics in superconducting arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the Generation of Positrons near the Threshold

The results of experimental studies of positron generation near the threshold carried out in 2018 at the ILC MSU femtosecond laser complex and the LUE-8 linear electron accelerator of the Institute for Nuclear Research of the Russian Academy of Sciences are presented. The measurements were carried out using three different detection methods: using a MEDIPIX detector; phosphor films and video cameras; as well as scintillation arrays and silicon photomultipliers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive linear predictor FIR filter based on the Cyclone V FPGA with HPS to reduce narrow band RFI in AERA radio detection of cosmic rays

We present the new approach to a filtering of radio frequency interferences (RFI) in the Auger Engineering Radio Array (AERA) which study the electromagnetic part of the Extensive Air Showers. The radio stations can observe radio signals caused by coherent emissions due to geomagnetic radiation and charge excess processes. AERA observes frequency band from 30 to 80 MHz. This range is highly contaminated by human-made RFI. In order to improve the signal to noise ratio RFI filters are used in AERA to suppress this contamination. The first kind of filter used by AERA was the Median one, based on the Fast Fourier Transform (FFT) technique. The second one, which is currently in use, is the infinite impulse response (IIR) notch filter. The proposed new filter is a finite impulse response (FIR) filter based on a linear prediction (LP). A periodic contamination hidden in a registered signal (digitized in the ADC) can be extracted and next subtracted to make signal cleaner. The FIR filter requires a calculation of n=32, 64 or even 128 coefficients (dependent on a required speed or accuracy) by solving of n linear equations with coefficients built from the covariance Toeplitz matrix. This matrix can be solved by the Levinson recursion, which is much faster than the Gauss procedure. The filter has been already tested in the real AERA radio stations on Argentinean pampas with a very successful results. The linear equations were solved either in the virtual soft-core NIOSR processor (implemented in the FPGA chip as a net of logic elements) or in the external Voipac PXA270M ARM processor. The NIOS processor is relatively slow (50 MHz internal clock), calculations performed in an external processor consume a significant amount of time for data exchange between the FPGA and the processor. Test showed a very good efficiency of the RFI suppression for stationary (long-term) contaminations. However, we observed a short-time contaminations, which could not be suppressed either by the IIR-notch filter or by the FIR filter based on the linear predictions. For the LP FIR filter the refreshment time of the filter coefficients was to long and filter did not keep up with the changes of a contamination structure, mainly due to a long calculation time in a slow processors. We propose to use the Cyclone V SE chip with embedded micro-controller operating with 925 MHz internal clock to significantly reduce a refreshment time of the FIR coefficients. The lab results are promising. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Linear accelerator x-ray sources with high duty cycle

X-ray cargo inspection systems typically use a several-MV pulsed linear accelerator (linac) to produce a bremsstrahlung spectrum of x rays by bombarding a target with electrons. The x rays traverse the cargo and are detected by a detector array. Spectroscopy of the detected x rays is very desirable: if one can determine the spectrum of the transmitted x rays, one can determine the Z of the material they traversed. Even in relatively low-dose modes of operation, thousands of x rays arrive at each detector element during each pulse, unless the x rays are heavily absorbed or scattered by the cargo. For portal or fixed-site systems, dose rates, and therefore x-ray count rates, are even higher. Because of the high x-ray count rate, spectroscopy is impractical in conventional cargo inspection systems, except in certain special cases. For a mobile system, typical pulse durations are a few microseconds, and the number of pulses is on the order of 100 per second, leading to a duty factor of about 0.04%. Clearly, a linear accelerator x-ray source with much higher duty factor would be useful, since then the same number of x rays could be spread out over time, reducing the x-ray count rate. In this paper, we explore the possibility of designing a linear accelerator system, using more or less Conventional Off the Shelf (COTS) components, capable of duty cycles of 1% or greater. A survey was conducted of available linac RF source options and, given the possibilities, calculations were performed for suitable beam centerline designs. Keeping in mind that the size and cost of the accelerator system should be practical for use in a mobile cargo inspection system, only a few options are shown to be reasonably feasible, both requiring the use of klystrons instead of the magnetrons used in conventional systems. An S-Band design appears clearly possible, and there is also a promising X-Band design.

43 PARTICLE ACCELERATORS↗

Airborne Acoustic Vortex End Effector‐Based Contactless, Multi‐Mode, Programmable Control of Object Surfing

Abstract Tweezers based on optical, electric, magnetic, and acoustic fields have shown great potential for contactless object manipulation. However, current tweezers designed for manipulating millimeter‐sized objects such as droplets, particles, and small animals exhibit limitations in translation resolution, range, and path complexity. Here, a novel acoustic vortex tweezers system is introduced, which leverages a unique airborne acoustic vortex end effector integrated with a three‐degree‐of‐freedom (DoF) linear motion stage, for enabling contactless, multi‐mode, programmable manipulation of millimeter‐sized objects. The acoustic vortex end effector utilizes a cascaded circular acoustic array, which is portable and battery‐powered, to generate an acoustic vortex with a ring‐shaped energy pattern. The vortex applies acoustic radiation forces to trap and spin an object at its center, simultaneously protecting this object by repelling other materials away with its high‐energy ring. Moreover, The vortex tweezers system facilitates contactless, multi‐mode, programmable object surfing, as demonstrated in experiments involving trapping, repelling, and spinning particles, translating particles along complex paths, guiding particles around barriers, translating and rotating droplets containing zebrafish larvae, and merging droplets. With these capabilities, It is anticipated that the tweezers system will become a valuable tool for the automated, contactless handling of droplets, particles, and bio‐samples in biomedical and biochemical research.

Li, Teng↗

Multi-channel conduction in redox-based resistive switch modelled using quantum point contact theory

A simple analytic model for the electron transport through filamentary-type structures in Si-rich silica (SiO{sub x})-based resistive switches is proposed. The model is based on a mesoscopic description and is able to account for the linear and nonlinear components of conductance that arise from both fully and partially formed conductive channels spanning the dielectric film. Channels are represented by arrays of identical scatterers whose number and quantum transmission properties determine the current magnitude in the low and high resistance states. We show that the proposed model not only reproduces the experimental current-voltage (I-V) characteristics but also the normalized differential conductance (dln(I)/dln(V)-V) curves of devices under test.

36 MATERIALS SCIENCE↗

Beam power scale-up in micro-electromechanical systems based multi-beam ion accelerators

We report on the development of multi-beam RF linear ion accelerators that are formed from stacks of low cost wafers and describe the status of beam power scale-up using an array of 120 beams. The total argon ion current extracted from the 120-beamlet extraction column was 0.5 mA. The measured energy gain in each RF gap reached as high as 7.25 keV. We present a path of using this technology to achieve ion currents >1 mA and ion energies >100 keV for applications in materials processing.

47 OTHER INSTRUMENTATION↗

FBG array-based random distributed feedback Raman fibre laser

We have demonstrated the possibility of making a Raman laser with a random distributed feedback ensured by an array of 57 fibre Bragg gratings with random phases and amplitudes inscribed in a 13-m-long polarisation-maintaining passive fibre. The linearly polarised cw output power at a wavelength of 1092.3 nm reaches 5.7 W. The laser linewidth at the highest output power is about 80 pm. In the nearthreshold regime, we observe single-frequency lasing with a linewidth under 100 kHz as determined by self-heterodyne measurements. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anharmonic Bloch oscillations in a coupler composed of two parallel optical fibre arrays

The effects of laser beam propagation in a coupler composed of two parallel optical-fibre arrays are studied by the coupled-mode method taking into account the interaction of a given fibre with the nearest neighbours and the linear dependence of the propagation constant on the fibre number. It is shown that, due to the complex structure of each subsystem, the structure of light intensity spatial distribution becomes significantly complicated in the system under study. The occurrence of space limited transverse light diffraction is predicted. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DISCOVERY OF THE FIRST GIANT DOUBLE RADIO RELIC IN A GALAXY CLUSTER FOUND IN THE PLANCK SUNYAEV-ZEL'DOVICH CLUSTER SURVEY: PLCK G287.0+32.9

We report the discovery of large-scale diffuse non-thermal radio emission in PLCK G287.0+32.9, an exceptionally hot (T {approx} 13 keV), massive, and luminous galaxy cluster, strongly detected by the Planck satellite in a recent, all-sky blind search for new clusters through Sunyaev-Zel'dovich effect. Giant Metrewave Radio Telescope 150 MHz and Very Large Array 1.4 GHz radio data reveal a pair of giant (>1 Mpc) 'arc'-shaped peripheral radio relics (signatures of shock waves) of unprecedented scale (linear separation {approx}4.4 Mpc at redshift 0.39), located at distances from the cluster center that are about 0.7 and 1.3 of the cluster's virial radius, respectfully. Another possible giant relic and a radio halo is detected closer to the cluster center. These relic sources are unique 'signposts' of extremely energetic mergers and shocks (both ongoing and past) that are assembling and heating up this very massive galaxy cluster. They are also a probe of the filamentary cosmic-web structure beyond the cluster virial radius. Optical imaging with the IUCAA 2 m telescope and XMM-Newton X-ray data confirm a very rich galaxy cluster with a morphologically disturbed core region, suggesting a dynamically perturbed merging system.

79 ASTRONOMY AND ASTROPHYSICS↗

DEEP RADIO CONTINUUM IMAGING OF THE DWARF IRREGULAR GALAXY IC 10: TRACING STAR FORMATION AND MAGNETIC FIELDS

We exploit the vastly increased sensitivity of the Expanded Very Large Array to study the radio continuum and polarization properties of the post-starburst, dwarf irregular galaxy IC 10 at 6 cm, at a linear resolution of {approx}50 pc. We find close agreement between radio continuum and H{alpha} emission, from the brightest H II regions to the weaker emission in the disk. A quantitative analysis shows a strictly linear correlation, where the thermal component contributes 50% to the total radio emission, the remainder being due to a non-thermal component with a surprisingly steep radio spectral index of between -0.7 and -1.0 suggesting substantial radiation losses of the cosmic-ray electrons. We confirm and clearly resolve polarized emission at the 10%-20% level associated with a non-thermal superbubble, where the ordered magnetic field is possibly enhanced due to the compression of the expanding bubble. A fraction of the cosmic-ray electrons has likely escaped because the measured radio emission is a factor of three lower than what is suggested by the H{alpha}-inferred star formation rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Shear Assisted Processing and Extrusion (ShAPE) of Aluminum Alloy 7075, 2024, and Al-12.4TM

The most common aluminum alloys utilized in the aerospace industry are 7075 and 2024 due to their high strength-to-weight ratio compared to advanced high strength steels and other aluminum alloys. Despite excellent performance, these aluminum alloys have seen limited use outside of the aerospace industry due in part to high cost. If high-performance aluminum extrusions could be made more cost effectively by eliminating energy intensive process steps typical of conventional extrusion, then numerous opportunities exist for more widespread adoption. A key reason for the high cost of 7075 and 2024 extrusions (25-75% higher than 6061) is their slow extrusion speed. 7075 and 2024 are limited to 2 m/min and 3.5 m/min respectively, in contrast to 6061 which can be extruded at 20–80 m/min. In addition to slow speed, aluminum alloys require numerous thermal treatments throughout the extrusion process including homogenization and pre-heating prior to extrusion, and solution heat treating and artificial aging after extrusion. Each of these steps contribute to the total energy consumed during manufacturing of extruded components. This project investigates the use of ShAPE to improve extrusion speed and reduce, or even eliminate, the typical thermal treatments for high strength aluminum alloys, all while improving material performance. The overarching goal of this project was to demonstrate that Shear Assisted Processing and Extrusion (ShAPE) can manufacture high-performance aluminum alloy tubing with lower manufacturing energy and improved mechanical properties compared to conventional extrusion. Unlike conventional extrusion where the billet is rammed against a stationary die using a strictly linear motion, the ShAPE process superimposes a rotational shear force by spinning the die while the billet is plunged. Compared to conventional linear extrusion, the ShAPE process imparts significantly more strain into the feedstock material, which enables the formation of novel microstructures. These microstructures manifest an array of property and process improvements for extrusion of high-performance aluminum alloys. The following accomplishments were achieved for this project: Extrusion of 7075 at 12.2 meters/min compared to 2 meters/min for conventional extrusion; Elimination of 7075 billet homogenization (430 °C for 20 hours) which is required prior to conventional extrusion; Elimination of 7075 billet pre-heating (400 °C for 1 hour) in a separate furnace which is required prior to conventional extrusion; Achieved 7075-T6with yield strength = 595 MPa, ultimate tensile strength = 531MPa, and elongation = 17.4% for extrusions made from unhomogenized billets. Exceeds the ASTM and ASM standard, and typical industry values; Achieved 7075-T5 (i.e., no solution heat treatment) with yield strength = 588 MPa, ultimate tensile strength = 535 MPa, and elongation = 14.8% for extrusions made from homogenized billets; Extrusion of 2024 at 7.4 meters/min compared to 3.5 meters/min for conventional extrusion; Achieved 2024-T8510 yield strength = 522 MPa, ultimate strength = 510MPa, and elongation = 7.1% for extrusions made from wrought billets. Exceeds the ASTM and ASM standard, and typical industry values; Extrusion of Al-12.4TM high-performance aluminum powder directly into tubing, in a single step, which eliminates process steps typical of powder metallurgy extrusion.

36 MATERIALS SCIENCE↗

Optimal read/write memory system components

Two holographic data storage and display systems, voltage gradient ionization system, and linear strain manipulation system are discussed in terms of creating fast, high bit density, storage device. Components described include: novel mounting fixture for photoplastic arrays; corona discharge device; and block data composer.

Kozma, A.↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗

A Simple Approach for Calibrating Imaging Systems with a Solid-State Sensor

Solid-state array imaging has become an indispensable tool for various modem scientific instrumentation and industrial applications. Often in experiments, use of an imaging system with linear response is very desirable. The linearity of commercial products, however, has yet to be accurately determined in order to assess their nonlinearity effects. Linearity is affected both by sensors and electronics. It is also very desirables to employ low-cost products if we can provide the performance comparable of expensive ones through calibration. Here, we present a very simple approach for approximately checking linearity of imaging systems and also a simple calibration method for precisely measuring intensity ratio or relative intensity variation. These methods can be readily implemented with existing equipment. The calibration method works well with an intermediate-grade analog sensor interfaced by a frame grabber. In our initial attempt for calibration, the nonlinearity of the camera can be reduced from about five percent to much less than one percent in standard deviation.

Leslie, Fred W.↗

Unconventional Defects in a Quasi-One-Dimensional KMn 6 Bi 5

Quasi-one-dimensional (Q1D) structures comprising a compact array of indefinitely long 1D nanowires (NWs) are scarce, especially in a bulk device-scale showing metallic and semiconducting behaviors along different axes. Unlike plentiful observations of nature of defects in three-/two -dimensional materials, there is a notable paucity of such reports in Q1D. Herein we present unconventional motific defects and their properties in a bulk Q1D KMn 6 Bi 5 crystal, in which an individual NW motif acts as one body. We discovered motific inter- and intra-NW defects, such that a linear set of 1D motifs are displaced. Stress generates two domains with altered inter-NW spacings and a Bi–Mn solid solution grain, leading to a local bulk plasmon shift due to NW array reconfiguration as well as atomic rearrangement. The observation of such exotic defects and associated phenomena in this Q1D may provide guidance on overall defect mechanism in other Q1D systems and their collective anisotropic properties.

36 MATERIALS SCIENCE↗