Toward Unified Autonomous Scattering Experiments: A Cross-Facility Case Study at ALS and PETRA III

Autonomous experiments rely on the integration of control, data acquisition, analysis, and decision-making frameworks. While such systems have been demonstrated at individual facilities, adapting them to additional instruments remains challenging due to differences in local infrastructure. We present a modular workflow that connects existing open-source tools for data access (Tiled), workflow orchestration (Prefect), analysis and visualization (pyFAI, Plotly Dash), and Gaussian-process-based adaptive sampling (gpCAM) into a unified framework for autonomous scattering experiments. The same configuration operates across two synchrotron beamlines (ALS 7.3.3 and PETRA III P03) with only minimal facility-specific adjustments, as shown in proof-of-concept demonstrations. This validates that a consistent design emphasizing modularity and shared interfaces can ease deployment across diverse experimental environments. The resulting framework provides a flexible foundation for extending autonomous control and analysis capabilities beyond a single beamline or instrument.

47 OTHER INSTRUMENTATION↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Findings of the African Combustion Aerosol Collaborative Intercomparison Analysis (ACACIA) Pilot Project to Understand the Optical Properties of Biomass Burning Smoke

Africa is a critical source of biomass burning (BB) aerosols, and its importance is increasing. The African Combustion Aerosol Collaborative Intercomparison Analysis (ACACIA) Pilot Project set to optically characterize BB aerosol generated from sub-Saharan African fuels. We used a photoacoustic spectrometer as a reference instrument to determine the multiple-scattering correction factor C λ for an AE33 aethalometer at three wavelengths, which produced weighted mean values of C 370 =3.69, C 470 =5.65, and C 520 =6.39. C λ increased with wavelength and C 370 was statistically independent of the others, suggesting a single C λ is insufficient, especially in BB scenarios. While a dependence of C λ on burning state was not found, C λ was shown to strongly relate to particle single scattering albedo (SSA, ω). When Cλ was plotted against SSA, values slowly rose at low SSA values, followed by a sharp rise around an SSA of ∼ 0.9; indicating a larger correction needed for less absorbing aerosol. A number of functions operating on either SSA or C λ were explored and the best function was -C λ /(1-C λ )=Aω+B. This is an important parametrization of C λ specifically geared towards BB aerosol from African fuels under different aging states, and is of particular importance for future field work in that continent. An Ångström matrix plot shows that African BB aerosol can have values more akin to dust, which demonstrates that these fuels are distinct in their wavelength dependence from more typical BB aerosol. Lastly, we examined the mass extinction and absorbance cross sections for BB aerosol generated for the same fuels with two different tube furnace setups. Not only is this combustion method flexible, it was found to be reproducible between labs.

47 OTHER INSTRUMENTATION↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Chiral Kirigami for Bend‐Tolerant Reconfigurable Hologram with Continuously Variable Chirality Measures

Abstract Despite the commonality of static holograms, the holography with multiple information layers and reconfigurable grey‐scale images at communication frequencies remain a confluence of scientific challenges. One well‐known difficulty is the simultaneous modulation of phase and amplitude of electromagnetic wavefronts with a high modulation depth. A less appreciated challenge is scrambling of the information and images with hologram bending. Here, this work shows that chirality‐guided pixelation of plasmonic kirigami sheets enables tunable multiplexed holography at terahertz (THz) frequencies. The convex and concave structures with slanted Au strips exhibit gradual variations in geometries facilitating modulation of light ellipticity reaching 40 deg. Real‐time switching of 3D images of the letter “ M ” and the Mona Lisa demonstrates the possibility of complex grey‐scale information content and importance of continuously variable mirror asymmetry. Microscale chirality measures of each pixel experiences little change with bending while retaining controllable reconfigurability upon stretching, which translates to remarkable resilience of chiral holograms to bending. Simplicity of their design with local chirality measures opens the door to information technologies with fault‐tolerant THz encryption, wearable holographic devices, and new communication technologies.

36 MATERIALS SCIENCE↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

Dislocation‐Driven Formation of Oriented Macroperiodic Metastructures of Curved Single Crystal Lattices in Glass

Abstract Single crystals fabricated in glass by localized heating can develop uniquely deformed lattices stabilized by the surrounding amorphous medium. The development of lattice curvature appears to be intrinsic to the crystal growth process in some systems, while the result of the locally changing crystallography in others. In this work, a model laser‐fabricated rotating lattice Sb 2 S 3 crystal grown in stoichiometric glass is used to demonstrate fabrication of novel macroperiodic metastructures that utilize intrinsic lattice curvature superimposed with subtle crystallographic influences. The limited availability of slip systems drives the lattice curvature magnitude to vary with crystal growth direction, maximizing for lattices aligned with the predominant Burgers vector along with corresponding increases in dislocation density. Misaligned lattice orientations form smaller secondary lattice curvatures arising from misaligned Burgers vectors with further elastic contributions. Over extended crystal growth, these secondary components align the lattice to rotate about either the <001> or <010> crystal axes forming repeating metastructures of lattice orientation with periodicity 20–160 microns in length. The mechanistic approach used in this work may be expanded to other systems with known slip systems to better understand and design macroperiodic metastructures.

36 MATERIALS SCIENCE↗

The Future of a Myriad of Accelerated Biodiscoveries Lies in AI‐Powered Mass Spectrometry and Multiomics Integration

The intersection of modern artificial intelligence (AI) and mass spectrometry (MS) is set to transform the MS‐based “omics” research fields, particularly proteomics, metabolomics, lipidomics, and glycomics, enabling advancements across a wide range of domains, from health to environment and industrial biotechnology. Beginning with an overview of key challenges inherent in MS software pipelines, this personal perspective explores how AI‐driven solutions can address them to enhance data processing, integration and interpretation. It proposes a paradigm shift in molecular identification and quantitation algorithms, leveraging AI to enable holistic interpretation of MS‐based multiomics data. While centered on MS‐based omics, this holistic AI‐driven paradigm is also critical for connecting dynamic biochemical changes to genomics and transcriptomics contexts, reinforcing the integrative value of MS in multiomics research. Ultimately, this AI‐driven approach could enhance efficiency, accuracy, and molecular breadth of coverage, deepening our systems‐level understanding of biological processes and accelerating a myriad of biodiscoveries.

47 OTHER INSTRUMENTATION↗