Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A wide-band high-resolution spectrum analyzer

A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.

Quirk, Maureen P.↗

A Nanometer Aerosol Size Analyzer (nASA) for Rapid Measurement of High-Concentration Size Distributions

We have developed a fast-response Nanometer Aerosol Size Analyzer (nASA) that is capable of scanning 30 size channels between 3 and 100 nm in a total time of 3 seconds. The analyzer includes a bipolar charger (P0210), an extended-length Nanometer Differential Mobility Analyzer (Nano-DMA), and an electrometer (TSI 3068). This combination of components provides particle size spectra at a scan rate of 0.1 second per channel free of uncertainties caused by response-time-induced smearing. The nASA thus offers a fast response for aerosol size distribution measurements in high-concentration conditions and also eliminates the need for applying a de-smearing algorithm to resulting data. In addition, because of its thermodynamically stable means of particle detection, the nASA is useful for applications requiring measurements over a broad range of sample pressures and temperatures. Indeed, experimental transfer functions determined for the extended-length Nano-DMA using the Tandem Differential Mobility Analyzer (TDMA) technique indicate the nASA provides good size resolution at pressures as low as 200 Torr. Also, as was demonstrated in tests to characterize the soot emissions from the J85-GE engine of a T38 aircraft, the broad dynamic concentration range of the nASA makes it particularly suitable for studies of combustion or particle formation processes. Further details of the nASA performance as well as results from calibrations, laboratory tests and field applications are presented.

Han, Hee-Siew↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

Modeling Techniques Used to Analyze Safety of Payloads for Generic Missile Type Weapons Systems During an Indirect Lightning Strike

During lightning strikes buildings and other structures can act as imperfect Faraday Cages, enabling electromagnetic fields to be developed inside the facilities. Some equipment stored inside these facilities may unfortunately act as antenna systems. It is important to have techniques developed to analyze how much voltage, current, or energy dissipation may be developed over valuable components. In this discussion we will demonstrate the modeling techniques used to accurately analyze a generic missile type weapons system as it goes through different stages of assembly. As work is performed on weapons systems detonator cables can become exposed. These cables will form different monopole and loop type antenna systems that must be analyzed to determine the voltages developed over the detonator regions. Due to the low frequencies of lightning pulses, a lumped element circuit model can be developed to help analyze the different antenna configurations. We will show an example of how numerical modeling can be used to develop the lumped element circuit models used to calculate voltage, current, or energy dissipated over the detonator region of a generic missile type weapons system.

42 ENGINEERING↗

Application of Printed Circuit Board Technology to FT-ICR MS Analyzer Cell Construction and Prototyping

Although Fourier transform ion cyclotron resonance mass spectrometry (FT-ICRMS) remains themass spectrometry platform that provides the highest levels of performance for mass accuracy and resolving power, there is room for improvement in analyzer cell design as the ideal quadrupolar trapping potential has yet to be generated for a broadband MS experiment. To this end, analyzer cell designs have improved since the field’s inception, yet few research groups participate in this area because of the high cost of instrumentation efforts. As a step towards reducing this barrier to participation and allowing for more designs to be physically tested, we introduce a method of FT-ICR analyzer cell prototyping utilizing printed circuit boards at modest vacuum conditions. This method allows for inexpensive devices to be readily fabricated and tested over short intervals and should open the field to laboratories lacking or unable to access high performance machine shop facilities because of the required financial investment.

Analyzer Cell↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

Compact Multichannel Charged-Particle Energy Analyzer Based on a Conical Cut Electrode

An electrostatic compact analyzer for obtaining the energy spectrum and for detecting simultaneously charged particles in a wide energy range, which is especially important for fast processes in various materials, has been proposed and designed. The energy analyzer consists of an outer conical electrode with closed end faces, which is cut into parts and fed in accordance with the law of odd numbers, and an grounded inner electrode on the surface of which charged particle beams with a wide energy range are focused. To increase the sharpness of low-energy beam focusing, an auxiliary, very small conical electrode is introduced. In spite of the small energy dispersion factor, the optimal regime of operation of the proposed analyzer with energy resolution not worse than 1% has been found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SynopFrame: Multiscale time-dependent visual abstraction framework for analyzing DNA nanotechnology simulations

We present an open-source framework, SynopFrame, that allows DNA nanotechnology (DNA-nano) experts to analyze and understand molecular dynamics simulation trajectories of their designs. We use a multiscale multi-dimensional abstraction space, connect the representations to a projected conformational space plot of the structure’s temporal sequence, and thus enable experts to analyze the dynamics of their structural designs and, specifically, failure cases of the assembly. In addition, our time-dependent abstraction representation allows the biologists, for the first time in a smooth and structurally clear way, to identify and observe temporal transitions of a DNA-nano design from one configuration to another, and to highlight important periods of the simulation for further analysis. We realize SynopFrame as a dashboard of the different synchronized 3D spatial and 2D schematic visual representations, with a color overlay to show essential properties such as the status of hydrogen bonds. The linking of the spatial, schematic, and abstract views ensures that users can effectively analyze the high-frequency motion. We also categorize the status of the hydrogen bonds into a new format to allow us to color-encode it and overlay it on the representations. To demonstrate the utility of SynopFrame, we describe example usage scenarios and report user feedback.

Abstraction space↗

$\mathrm{D}$ark$\mathrm{F}$lux: A new tool to analyze indirect-detection spectra of next-generation dark matter models

Here we present DarkFlux, a software tool designed to analyze indirect-detection signatures for next-generation models of dark matter (DM) with multiple annihilation channels. Version 1.0 of this tool accepts user-generated models with 2→2 tree-level dark matter annihilation to pairs of Standard Model (SM) particles and analyzes DM annihilation to γ rays. The tool consists of three modules, which can be run in a loop in order to scan over DM mass if desired: The annihilation fraction module calls an internal installation of MadDM, a dark matter phenomenology plugin for the Monte Carlo event generator MadGraph5 _ aMC@NLO, to compute the thermally averaged cross section $\langle σv\rangle_i$ for each annihilation channel $χχ$ ($\bar{χ}$,$χ^†$)→ i $\∈{SM, SM}. . The module then computes the fractional annihilation rate (annihilation fraction) into each channel. The flux module combines the flux spectrum from each annihilation channel, weighted by the appropriate annihilation fractions, to compute the total flux at Earth due to DM annihilation. In DarkFlux v1.0, this module specifically computes the γ-ray flux for each channel using the publicly available PPPC4DMID tables. The analysis module compares the total flux to observational data and computes the upper limit at 95% confidence level (CL) on the total thermally averaged DM annihilation cross section. In DarkFlux v1.0, this module compares the total γ-ray flux to a joint-likelihood analysis of fifteen dwarf spheroidal galaxies (dSphs) analyzed by the Fermi-LAT collaboration. DarkFlux v1.0 automatically provides data tables and can plot the output of these three modules. In this manual, we briefly motivate this indirect-detection computer tool and review the essential DM physics. We then describe the several modules of DarkFlux in greater detail. Finally, we show how to install and run DarkFlux and provide two worked examples demonstrating its capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Unit cell dilation technique for analyzing dilatometry data in microalloyed steels

Highlights: • Lever rule is not an adequate method to analyze dilatometry data. • A method called “Unit Cell Dilation” is developed to analyze the dilatometry data. • The new method calculates phase fractions while accounting for chemical changes during diffusive phase transformation. - Abstract: Dilatometry is the most accurate and common method for measuring the kinetics of phase transformations in solid specimens. Despite the development of a more accurate technique, an inferior method, i.e., the lever rule, is widely used in the scientific community to interpret raw dilatometry data. This paper introduces a sound mathematical approach to modeling the physical phenomena of phase transformations, named continuous sequential phase transformation (CSPT). CSPT is used in creating an algorithm called unit cell dilation (UCD) that is used for analyzing the continuous phase transformation of two microalloyed steels. Results show that the UCD algorithm generates quantitative data for the phase content of the steel that is in good agreement with metallographic observations. The source code for an implementation of the UCD algorithm is distributed under GPL-3.0 license and available for download at (https://github.com/Nassehk/Dilatometry-analysis.git).

36 MATERIALS SCIENCE↗

Neutron Irradiation Induced Changes in Isotopic Abundance of 6Li and 3D Nanoscale Distribution of Tritium in LiAlO2 Pellets Analyzed by Atom Probe Tomography

Tritium, a radioactive isotope of hydrogen is produced by neutron irradiation of 6Li enriched LiAlO2 pellets in Tritium producing burnable absorber rods (TPBARs). Three-dimensional nanoscale mapping of Tritium in irradiated pellets is critical to understand its spatial variation and its association with various microstructural features in the pellets. Spatially resolved analysis of 6Li isotopic enrichment in such ceramic pellets before and after irradiation can provide insights to heterogeneities in Li isotopic distribution. However, Li being a light isotope, its spatially resolved compositional or isotopic analysis is a challenging task to most analytical methods. Here we used atom probe tomography, to evaluate the Li isotopic enrichment in both the LiAlO¬2 matrix and the Li deficient secondary phase LiAl5O8 before irradiation. These results were then compared with 6Li isotopic ratio measured by APT analysis of neutron irradiated pellets to clearly demonstrate the unique capability of APT to quantitatively analyze the isotopic enrichment of 6Li as well as for other light elements present in these materials. Evidence for heterogenous nanoscale distribution of 3H and O3H within irradiated pellet microstructure is also provided, which is attributed to 3H trapping in irradiation induced vacancy clusters or voids within the LiAlO2 matrix. The characterization results given here, now prove the feasibility for using APT for analyzing nanoscale spatially resolved isotopic enrichment of Li as well as other light elements such as Tritium in TPBARs. This work also paves way to adopt APT for analyzing light elements such as Li and tritium in materials used for nuclear fusion reactor applications, geochemistry, astrophysics as well as for energy storage applications.

Devaraj, Arun↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

The role of acceptance angle in measurements with ion energy analyzers: Study by numerical simulations

The importance of an acceptance angle in the plasma diagnostics with ion energy analyzers is investigated by means of numerical simulations. It is shown that wide acceptance angles result in low energy tails in measured ion distribution functions (IDF{sub x}). For flowing plasmas or plasmas with beams, the orientation of the analyzer's orifice gives different results due to bending of ion trajectories in the vicinity of the analyzer. It is demonstrated that the maximum in the IDF{sub x} is at energies lower than the plasma potential. Simulations are done with DIP3D, a three-dimensional particle-in-cell code.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: The intermodulation lockin analyzer

Nonlinear systems can be probed by driving them with two or more pure tones while measuring the intermodulation products of the drive tones in the response. We describe a digital lockin analyzer which is designed explicitly for this purpose. The analyzer is implemented on a field-programmable gate array, providing speed in analysis, real-time feedback, and stability in operation. The use of the analyzer is demonstrated for intermodulation atomic force microscopy. A generalization of the intermodulation spectral technique to arbitrary drive waveforms is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on a logarithmically bent Laue crystal analyzer for X-ray monochromatic backlight imaging

A new logarithmically bent Laue imaging crystal analyzer (LBLICA) was proposed to obtain the monochromatic image of plasmas and exhibited a great potential for application in the Inertial Confinement Fusion experiment over a large field of view (FOV) and with a high spatial resolution. The imaging geometry of the LBLICA has been discussed. According to the Bragg condition and the equation of the logarithmic spiral, the key image parameters of the crystal analyzer, including the system magnification, the spatial resolution, and the FOV, have been analyzed theoretically. An experiment has been performed with a Cu target X-ray tube as a backlighter to backlight a mesh grid consisting of 50-μm Cu wires, and the monochromatic image of the grid has been obtained with a spatial resolution of approximately 30 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Portable rare-earth element analyzer using pyroelectric crystal

We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spatially resolved retarding field energy analyzer design suitable for uniformity analysis across the surface of a semiconductor wafer

A novel retarding field energy analyzer design capable of measuring the spatial uniformity of the ion energy and ion flux across the surface of a semiconductor wafer is presented. The design consists of 13 individual, compact-sized, analyzers, all of which are multiplexed and controlled by a single acquisition unit. The analyzers were tested to have less than 2% variability from unit to unit due to tight manufacturing tolerances. The main sensor assembly consists of a 300 mm disk to mimic a semiconductor wafer and the plasma sampling orifices of each sensor are flush with disk surface. This device is placed directly on top of the rf biased electrode, at the wafer location, in an industrial capacitively coupled plasma reactor without the need for any modification to the electrode structure. The ion energy distribution, average ion energy, and average ion flux were measured at the 13 locations over the surface of the powered electrode to determine the degree of spatial nonuniformity. The ion energy and ion flux are shown to vary by approximately 20% and 5%, respectively, across the surface of the electrode for the range of conditions investigated in this study.

36 MATERIALS SCIENCE↗