Vapor generation methods for explosives detection research

The generation of calibrated vapor samples of explosives compounds remains a challenge due to the low vapor pressures of the explosives, adsorption of explosives on container and tubing walls, and the requirement to manage (typically) multiple temperature zones as the vapor is generated, diluted, and delivered. Methods that have been described to generate vapors can be classified as continuous or pulsed flow vapor generators. Vapor sources for continuous flow generators are typically explosives compounds supported on a solid support, or compounds contained in a permeation or diffusion device. Sources are held at elevated isothermal temperatures. Similar sources can be used for pulsed vapor generators; however, pulsed systems may also use injection of solutions onto heated surfaces with generation of both solvent and explosives vapors, transient peaks from a gas chromatograph, or vapors generated by s programmed thermal desorption. This article reviews vapor generator approaches with emphasis on the method of generating the vapors and on practical aspects of vapor dilution and handling. In addition, a gas chromatographic system with two ovens that is configurable with up to four heating ropes is proposed that could serve as a single integrated platform for explosives vapor generation and device testing. Issues related to standards, calibration, and safety are also discussed.

2,4-DNT↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work performed at SRNL as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization, an efficient and sensitive method was produced. Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly SRR Tank 50 samples. The statistical evaluations presented in this document support the following conclusions: for internal validation data, the two laboratories demonstrate biases of -4.3% for SRNL and 4.4% for Eurofins FGS, though neither are statistically significant at the 5% level. While the percent relative standard deviation for each of the laboratories is rather large (21.5% for SRNL and 18.4% for Eurofins FGS), there is no indication of a statistically significant difference between the two laboratories in the precision of these results. For the three sets of SRR quarterly Tank 50 samples, there is no indication of a statistically significant bias between the two laboratories at the 5% significance level. These results indicate that SRNL may provide data to the customer of statistically similar quality to Eurofins FGS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field evaluation of semi‐automated moisture estimation from geophysics using machine learning

Geophysical methods can provide three-dimensional (3D), spatially continuous estimates of soil moisture. However, point-to-point comparisons of geophysical properties to measure soil moisture data are frequently unsatisfactory, resulting in geophysics being used for qualitative purposes only. This is because (1) geophysics requires models that relate geophysical signals to soil moisture, (2) geophysical methods have potential uncertainties resulting from smoothing and artifacts introduced from processing and inversion, and (3) results from multiple geophysical methods are not easily combined within a single soil moisture estimation framework. To investigate these potential limitations, an irrigation experiment was performed wherein soil moisture was monitored through time, and several surface geophysical datasets indirectly sensitive to soil moisture were collected before and after irrigation: ground penetrating radar, electrical resistivity tomography (ERT), and frequency domain electromagnetics (FDEM). Data were exported in both raw and processed form, and then snapped to a common 3D grid to facilitate moisture prediction by standard calibration techniques, multivariate regression, and machine learning. A combination of inverted ERT data, raw FDEM, and inverted FDEM data was most informative for predicting soil moisture using a random regression forest model (one-thousand 60/40 training/test cross-validation folds produced root mean squared errors ranging from 0.025–0.046 cm 3 /cm 3 ). This cross-validated model was further supported by a separate evaluation using a test set from a physically separate portion of the study area. Machine learning was conducive to a semi-automated model-selection process that could be used for other sites and datasets to locally improve accuracy.

54 ENVIRONMENTAL SCIENCES↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Absolute Gas-Counting Capability for Low to Medium Activities

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing a capability to measure the absolute activity concentration of various gaseous radionuclides using length-compensated proportional-counting methods. This capability will enable the validation and use of low-level, gaseous radionuclide calibration standards for use in PNNL’s shallow underground laboratory. Two sets of unequal length proportional counters have been fabricated. These detector assemblies operate on a static gas-fill principle, in contrast to continuous, flow-through configurations. One set of three counters has been fabricated using ultra-low background (ULB) electroformed copper and low-background fabrication methods. Once fully operational, these ULB counters will be used in PNNL’s shallow underground counting laboratory for analysis of gases with low activity concentrations < 1 Bq/cc. A second set of four unequal length counters has been fabricated from Oxygen-Free High-Conductivity Copper (OFHC) using similar low-background cleaning and assembly methods. These OFHC counters will be operated above ground in the analysis of gases with activity concentrations in the range of 1-10 Bq/cc. A gas delivery system is being developed to actively mix the analyte gas with an appropriate amount of count-gas and uniformly deliver it to the counters with high accuracy and repeatability. A description of both detector assemblies and gas delivery system will be given along with a preliminary uncertainty analysis of a simulated 0.05 Bq/cm3 gas measurement.

Williams, Richard M.↗

Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond filament-laser ablation molecular isotopic spectrometry

A new remote sensing technology for real-time isotopic analysis is introduced: Femtosecond Filament-Induced Laser Ablation Molecular Isotopic Spectrometry (F 2 -LAMIS). The technique combines femtosecond (fs) laser filamentation and ablation-based molecular isotopic spectroscopy, thereby enabling isotopic analysis of samples at a distance, in ambient air and at ambient pressure conditions. Isotopic analysis of zirconium (Zr) samples by F 2 -LAMIS is demonstrated, and the molecular and atomic emission intensity, and properties of the filament-induced plasma generated at different filament propagation distances were investigated. Spectral fitting of F 2 -LAMIS spectra enabled semi-quantitative isotopic analysis without the use of calibration standards, which was independent of the filament propagation distance for the studied range. As a result, this technology provides new capabilities for direct isotopic ratio measurements at remote distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

Studies of the Correlation Between Ionospheric Anomalies and Seismic Activities in the Indian Subcontinent

The VLF (Very Low Frequency) signals are long thought to give away important information about the Lithosphere-Ionosphere coupling. It is recently established that the ionosphere may be perturbed due to seismic activities. The effects of this perturbation can be detected through the VLF wave amplitude. There are several methods to find this correlations and these methods can be used for the prediction of these seismic events. In this paper, first we present a brief history of the use of VLF propagation method for the study of seismo-ionospheric correlations. Then we present different methods proposed by us to find out the seismo-ionospheric correlations. At the Indian Centre for Space Physics, Kolkata we have been monitoring the VTX station at Vijayanarayanam from 2002. In the initial stage, we received 17 kHz signal and latter we received 18.2 kHz signal. In this paper, first we present the results for the 17 kHz signal during Sumatra earthquake in 2004 obtained from the terminator time analysis method. Then we present much detailed and statistical analysis using some new methods and present the results for 18.2 kHz signal. In order to establish the correlation between the ionospheric activities and the earthquakes, we need to understand what are the reference signals throughout the year. We present the result of the sunrise and sunset terminators for the 18.2 kHz signal as a function of the day of the year for a period of four years, viz, 2005 to 2008 when the solar activity was very low. In this case, the signal would primarily be affected by the Sun due to normal sunrise and sunset effects. Any deviation from this standardized calibration curve would point to influences by terrestrial (such as earthquakes) and extra-terrestrial (such as solar activities and other high energy phenomena). We present examples of deviations which occur in a period of sixteen months and show that the correlations with seismic events is significant and typically the highest deviation in terminator shift takes place up to a couple of days prior to the seismic event. We introduce a new method where we find the effects of the seismic activities on D-layer preparation time (DLPT) and the D-layer disappearance time (DLDT). We identify those days in which DLPT and DLDT exhibit deviations from the average value and we correlate those days with seismic events. Separately, we compute the energy release by the earthquakes and using this, we compute the total energy released locally from distant earthquakes and find correlations of the deviations with them. In this case also we find pre-cursors a few days before the seismic events. In a third approach, we consider the nighttime fluctuation method (differently quantified than the conventional way). We analyzed the nighttime data for the year 2007 to check the correlation between the night time fluctuation of the signal amplitude and the seismic events. Using the statistical method for all the events of the year and for the individual individual earthquakes (Magnitude > 5) we found that the night time signal amplitude becomes very high on three days prior to the seismic events.

58 GEOSCIENCES↗

Correlelations between the Anomalous Behaviour of the Ionosphere and the Seismic Events for VTX-MALDA VLF Propagation

One of the most important application of the VLF signals is that it contains possible information about the lithosphere-ionosphere coupling. In other words, in near future, it may be possible to predict seismic events by judging signatures of VLF signals. In this paper, we present the result of the monitoring of the VLF signals collected in the Malda branch of ICSP, located in Malda, West Bengal, for four years (2005, 2007-09) and we try to find out the co-relations, if any, between the ionospheric activities and the earthquakes. Here we use that VLF signals which are transmitted from the VTX station (18.2 KHz), located near Vijayanarayanam in Tamilnadu, about 2290 km away from the receiver. To find out the co-relation of the ionospheric activities with the seismic events such as earthquake, first we have to study the average signal throughout the year. For this, we plot the so-called standardized calibration curve using the four years data. Here we use a total of 481 no. of data. To establish the co-relation between the ionospheric activities and the seismic events, we use the data of the year 2008 and we found that the deviations of the anomalous data are co-related with the seismic event. We found that the highest deviation takes place one day prior to the seismic events. We also calculated the 'D-layer preparation time'(DLPT) and the 'D-layer disappearance time'(DLDT) for the data of 2008 and tried to establish the co-relation between the anomalous DLPT and DLDT with the seismic events, if any. We compare our result with the VLF signals received from other places.

58 GEOSCIENCES↗

Quantifying uncertainty in analysis of shockless dynamic compression experiments on platinum. I. Inverse Lagrangian analysis

Absolute measurements of solid-material compressibility by magnetically driven shockless dynamic compression experiments to multi-megabar pressures have the potential to greatly improve the accuracy and precision of pressure calibration standards for use in diamond anvil cell experiments. Here, to this end, we apply characteristics-based inverse Lagrangian analysis (ILA) to 11 sets of ramp-compression data on pure platinum (Pt) metal and then reduce the resulting weighted-mean stress–strain curve to the principal isentrope and room-temperature isotherm using simple models for yield stress and Grüneisen parameter. We introduce several improvements to methods for ILA and quasi-isentrope reduction, the latter including calculation of corrections in wave speed instead of stress and pressure to render results largely independent of initial yield stress while enforcing thermodynamic consistency near zero pressure. More importantly, we quantify in detail the propagation of experimental uncertainty through ILA and model uncertainty through quasi-isentrope reduction, considering all potential sources of error except the electrode and window material models used in ILA. Compared to previous approaches, we find larger uncertainty in longitudinal stress. Monte Carlo analysis demonstrates that uncertainty in the yield-stress model constitutes by far the largest contribution to uncertainty in quasi-isentrope reduction corrections. We present a new room-temperature isotherm for Pt up to 444 GPa, with 1-sigma uncertainty at that pressure of just under ±1.2%; the latter is about a factor of three smaller than uncertainty previously reported for multi-megabar ramp-compression experiments on Pt. The result is well represented by a Vinet-form compression curve with (isothermal) bulk modulus K 0 = 270.3 ± 3.8 GPa, pressure derivative K$^{'}_{0}$= 5.66 ± 0.10, and correlation coefficient $R_{K_{0},K^{'}_{0}}$= –0.843.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of Seven Organic Impurities in FD&C Yellow No. 6 by Ultra-High-Performance Liquid Chromatography

The U.S. Food and Drug Administration (FDA) batch certifies FD&C Yellow No. 6 (Y6) to ensure that the color additive meets requirements published in the Code of Federal Regulations (CFR), including specifications for seven organic manufacturing impurities consisting of two intermediates, a reaction by-product, an impurity originating from an intermediate, and three subsidiary colors. An ultra-high-performance liquid chromatography (UHPLC) method was developed and validated for determining seven organic impurities in Y6. For comparison, the currently used high-performance liquid chromatography (HPLC) method was also validated. The new UHPLC method uses a 1.7 µm particle size biphenyl column with aqueous ammonium formate and methanol as eluants. Analytes are identified by comparing their retention times and UV-visible spectra to those of reference standards. Calibration is performed in the presence of the dye matrix and analyte levels are determined from their peak areas. UHPLC and HPLC validation studies obtained linear calibration curves and excellent values for limits of detection, limits of quantitation, recovery, repeatability, and intermediate precision for all analytes. Survey analyses of 30 samples using the UHPLC and HPLC methods yielded results that were consistent within experimental error; however, the UHPLC method provided more accurate results for two analytes that coelute using the HPLC method. The UHPLC method satisfies the accuracy and precision requisites for routine certification of Y6. The UHPLC method is faster and generates less waste than the HPLC method while delivering better sensitivity, separation, and accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗