Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skipper CCD Long-Term Vacuum Chamber

The Skipper CCD is a high-sensitivity Charge Coupled Device (CCD) sensor designed at Fermilab that has extremely low readout noise. The Skipper can only be operated at pressures below 10-4Torr (about a millionth of an atmosphere). The purpose of this project was to investigate whether a long-term vacuum chamber could be used for the Skipper CCD, which would require only being re-pumped once a year. This would allow the Skipper to be fully integrated here at Fermilab and then be transported anywhere for immediate use.

Struven, Wolfgang↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions 10 B (n,α0γ) 7 Li (6%) and 10 B(n,α1γ) 7 Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts α, 7 Li and γ (electron recoils). A signal-to-noise improvement on the order of 10 4 over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m 2 . The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MISR Level 1A CCD Science data, all cameras (MIL1A_V1)

The Level 1A data are raw MISR data that are decommutated, reformatted 12-bit Level 0 data shifted to byte boundaries, i.e., reversal of square-root encoding applied and converted to 16 bit, and annotated (e.g., with time information). These data are used by the Level 1B1 processing algorithm to generate calibrated radiances. The science data output preserves the spatial sampling rate of the Level 0 raw MISR CCD science data. CCD data are collected during routine science observations of the sunlit portion of the Earth. Each product represents one 'granule' of data. A 'granule' is defined to be the smallest unit of data required for MISR processing. Also, included in the Level 1A product are pointers to calibration coefficient files provided for Level 1B processing. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].

CCD↗

MISR Level 1A CCD Science data, all cameras (MIL1A_V2)

The Level 1A data are raw MISR data that are decommutated, reformatted 12-bit Level 0 data shifted to byte boundaries, i.e., reversal of square-root encoding applied and converted to 16 bit, and annotated (e.g., with time information). These data are used by the Level 1B1 processing algorithm to generate calibrated radiances. The science data output preserves the spatial sampling rate of the Level 0 raw MISR CCD science data. CCD data are collected during routine science observations of the sunlit portion of the Earth. Each product represents one 'granule' of data. A 'granule' is defined to be the smallest unit of data required for MISR processing. Also, included in the Level 1A product are pointers to calibration coefficient files provided for Level 1B processing. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].

AM-1↗

Lloyd's Mirror for MTF Testing of MISR CCD

Direct measurement of CCD MTF using a unique Lloyd's mirror fringe projector is described. MTF measurements on the MISR linear CCD arrays have been performed as a function of spatial frequency, wavelength, number of charge transfers, radiation dosage, and device architecture. Test results are reported here.

MTF↗

Narrow-beam x-ray tests of CCD edge response.

The physical boundaries of a fully-depleted charged-coupled device (CCD) can lead to distorted field lines and non-uniform response. We study this response with a beam of X-rays constrained to a width of less than one pixel, and a system to map the CCD response as a function of transverse position.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-electron readout noise in a Skipper CCD fabricated on high resistivity silicon

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the detector in a low-energy X-ray detection experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Comparative study of ionization chamber detectors vis-a-vis a CCD detector for dispersive XAS measurement in transmission geometry

We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE THIRD US NAVAL OBSERVATORY CCD ASTROGRAPH CATALOG (UCAC3)

The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3, was released at the IAU General Assembly on 2009 August 10. It is the first all-sky release in this series and contains just over 100 million objects, about 95 million of them with proper motions, covering about R = 8-16 mag. Current epoch positions are obtained from the observations with the 20 cm aperture USNO Astrograph's 'red lens', equipped with a 4k x 4k CCD. Proper motions are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the southern hemisphere, the Yale/San Juan first epoch plates from the Southern Proper Motion (SPM) program (YSJ1) form the basis for proper motions. These data are supplemented by all-sky Schmidt plate survey astrometry and photometry obtained from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major differences of UCAC3 data as compared with UCAC2 include a completely new raw data reduction with improved control over systematic errors in positions, significantly improved photometry, slightly deeper limiting magnitude, coverage of the north pole region, greater completeness by inclusion of double stars, and weak detections. This of course leads to a catalog which is not as 'clean' as UCAC2 and problem areas are outlined for the user in this paper. The positional accuracy of stars in UCAC3 is about 15-100 mas per coordinate, depending on magnitude, while the errors in proper motions range from 1 to 10 mas yr{sup -1} depending on magnitude and observing history, with a significant improvement over UCAC2 achieved due to the re-reduced SPM data and inclusion of more astrograph plate data unavailable at the time of UCAC2.

79 ASTRONOMY AND ASTROPHYSICS↗

BRORFELDE SCHMIDT CCD CATALOG

The Brorfelde Schmidt CCD Catalog (BSCC) contains about 13.7 million stars, north of +49{sup 0} decl. with precise positions and V, R photometry. The catalog has been constructed from the reductions of 18,667 CCD frames observed with the Brorfelde Schmidt Telescope between 2000 and 2007. The Tycho-2 catalog was used for astrometric and photometric reference stars. Errors of individual positions are about 20-200 mas for stars in the R = 10-18 mag range. External comparisons with the Two Micron All-Sky Survey (2MASS) and Sloan Digital Sky Survey reveal possible small systematic errors in the BSCC of up to about 30 mas. The catalog is supplemented with J, H, and K{sub s} magnitudes from the 2MASS catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FOURTH US NAVAL OBSERVATORY CCD ASTROGRAPH CATALOG (UCAC4)

The fourth United States Naval Observatory (USNO) CCD Astrograph Catalog, UCAC4, was released in 2012 August (double-sided DVD and CDS data center Vizier catalog I/322). It is the final release in this series and contains over 113 million objects; over 105 million of them with proper motions (PMs). UCAC4 is an updated version of UCAC3 with about the same number of stars also covering all-sky. Bugs were fixed, Schmidt plate survey data were avoided, and precise five-band photometry was added for about half the stars. Astrograph observations have been supplemented for bright stars by FK6, Hipparcos, and Tycho-2 data to compile a UCAC4 star catalog complete from the brightest stars to about magnitude R = 16. Epoch 1998-2004 positions are obtained from observations with the 20 cm aperture USNO Astrograph's 'red lens', equipped with a 4k by 4k CCD. Mean positions and PMs are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the southern hemisphere, the first epoch plates from the Southern Proper Motion program form the basis for PMs, while the Northern Proper Motion first epoch plates serve the same purpose for the rest of the sky. These data are supplemented by 2MASS near-IR photometry for about 110 million stars and five-band (B, V, g, r, i) APASS data for over 51 million stars. Thus the published UCAC4, as were UCAC3 and UCAC2, is a compiled catalog with the UCAC observational program being a major component. The positional accuracy of stars in UCAC4 at mean epoch is about 15-100 mas per coordinate, depending on magnitude, while the formal errors in PMs range from about 1 to 10 mas yr{sup -1} depending on magnitude and observing history. Systematic errors in PMs are estimated to be about 1-4 mas yr{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

CCD MEASUREMENTS OF DOUBLE AND MULTIPLE STARS AT NAO ROZHEN AND ASV IN 2011. FIVE LINEAR SOLUTIONS

Using the 2 m telescope of the Bulgarian National Astronomical Observatory at Rozhen, observations of 222 double or multiple stars were carried out during three nights in 2011. This is the sixth series of measurements of CCD frames of double and multiple stars obtained at Rozhen. Also in 2011, using the 0.6 m telescope of the Serbian Astronomical Station on the mountain of Vidojevica, observations of 208 double or multiple stars were carried out during six nights. This is the first series of measurements of CCD frames of double and multiple stars obtained at this station. In this paper, we present the results for the position angle and angular separation for 337 pairs and residuals for 72 pairs with published orbital elements or linear solutions. These observations have angular separations in the range from 1.''37 to 172.''81, with a median angular separation of 7.''66. We also present the recalculated linear solutions for four pairs and one linear solution that has been calculated for the first time.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging

Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.

79 ASTRONOMY AND ASTROPHYSICS↗