Frequency-dependence of dynamic lung compliance during acute exposures to an altitude of 3,962 meters
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The point of view taken is that the Environmental Protection Agency (EPA) Air Quality Standards (AQS) represent conditions which must be made to exist in the ambient environment. The statistical techniques developed should serve as tools for measuring the closeness to achieving the desired quality of air. It is shown that the sampling frequency recommended by EPA is inadequate to meet these objectives when the standard is expressed as a level not to be exceeded more than once per year and sampling frequency is once every three days or less frequent.
A method is presented for using simple electronic components to obtain the high sensitivity needed to measure very slow crack growth rates. The technique presented can reduce the experimental time considerably and also yield a greater amount of data more accurately than optical techniques for measuring crack growth rates.
Under a sampling program operated in conformity with EPA guidelines, calculational procedures are described for estimating the corresponding ambient pollution level. The statistical independence of the data, the commutativity of expectation and exponential operations, and the statistical variability of the calculated results are quantitatively evaluated. It is shown that the recommended sampling frequencies of every third to every sixth day are inadequate in determining conformity when the standards are expressed as levels not to be exceeded more than once a year.
A ballast circuit employing a constant current diode and a vacuum tube that can provide a constant current over a voltage range of 1000 volts. The simple circuit can prove useful in studying voltage breakdown characteristics.
Calibration of the mode II aluminum fatigue specimen was performed experimentally to provide displacement and stress intensity coefficients over crack length to specimen width ratios (a/W) of 0.5 to 0.9. Displacements were measured both at the specimen notch mouth and at the intersection of the notch with the centerline of the loading pin holes.
An accelerated viscoelastic characterization procedure for use with polymer-based composite materials is presented which employs short term test data obtained using unidirectional specimens to predict the long term viscoelastic behavior of general composite laminates. This procedure is here illustrated using the Schapery (1966, 1969) nonlinear theory as the required viscoelastic constitutive model, as well as classical lamination theory for the lamination scheme. The technique is applied to T300/5208 graphite/epoxy.
An explanation is offered for the extreme sensitivity that has been observed in the power law parameters of the T300/934 graphite epoxy material systems during experiments to evaluate the system's viscoelastic response. It is shown that the singularity associated with the power law can explain the sensitivity as well as the observed variability in the calculated parameters. Techniques for minimizing errors are suggested.
Many manufacturing assembly tasks require fine compliant motion and fast, accurate positioning. Conventional robots perform poorly in these tasks because of their large mass, friction and backlash in gears, cogging in drive motors and other deleterious effects. Even robots equipped with special control systems enabling compliant operation offer only partial solutions. It is difficult or impossible to automate many product assemblies requiring fine, compliant motion. This problem can be greatly alleviated by dividing the manipulation system into coarse and fine domains. In this scenario, a standard industrial robot can serve as a coarse positioner which in turn carries a six degrees of freedom fine motion wrist. Thus the robot can access a workspace measured in meters at low bandwidth and low resolution while the wrist can move over millimeters at high bandwidth and high resolution during the final phase of the assembly operation. Work indicates that fine motion wrists using Lorentz levitation can greatly augment the accuracy and dexterity of robots because they are frictionless, have high bandwidths and have a single back drivable moving part. Also, since there is no contact between the moving and stationary parts, wear and contamination can be eliminated. The use of six Lorentz force actuators in combination with real time position and orientation sensing offers several important advantages over magnetic bearing approaches.
An International workshop was held to address how remote sensing technology could be used to support the environmental monitoring requirements of the Kyoto Protocol. An overview of the issues addressed and the findings of the workshop are discussed.
BACKGROUND: Net whole-body transcapillary fluid transport (TFT) between the circulation and the interstitial (extravascular) space may be calculated as: IV - deltaPV - UV - IL, where IV=infused or ingested volume (when applicable), deltaPV = change in plasma volume, UV=urine volume, and IL=insensible loss. RESULTS: Infusion of 30 mL/kg isotonic saline over 25 minutes increased supine TFT from a basal capillary reabsorption of -106+/-24 mL/h (mean+/-SE) to a net filtration of 1,229+/-124 mL/h. One hour after infusion, reabsorption of -236+/-102 mL/h was seen, and control reabsorption levels returned by 3 hours. Four hours of 30 mm Hg lower body negative pressure (LBNP) elicited no net TFT, probably because of upper body reabsorptive compensation for lower body capillary filtration. When ingestion of 1 L of isotonic saline accompanied LBNP, filtration of 145+/-10 mL/h occurred. Reabsorption of extravascular fluid into the circulation always followed LBNP. CONCLUSION: Application of this technique could aid understanding of physiologic conditions, experimental interventions, disease states, and therapies that cause or are influenced by fluid shifts between intravascular and interstitial compartments.
A human-in-the-loop experiment was conducted at the NASA Ames and Langley Research Centers, investigating the En Route Free Maneuvering component of a future air traffic management concept termed Distributed Air/Ground Traffic Management (DAG-TM). NASA Langley test subject pilots used the Autonomous Operations Planner (AOP) airborne toolset to detect and resolve traffic conflicts, interacting with subject pilots and air traffic controllers at NASA Ames. Experimental results are presented, focusing on conflict resolution maneuver choices, AOP resolution guidance acceptability, and performance metrics. Based on these results, suggestions are made to further improve the AOP interface and functionality.
In this paper, Rutgers University has teamed with the Jet Propulsion Laboratory (JPL) to pursue the development and demonstration of a novel haptic interfacing capability called MEMICA.
This paper addresses the problem of controlling a maniupulator in compliant motion while in contact with an environment having an unknown stiffness.
Explore the source record for details and available documents.
Pharmacovigilance is the science of, and activities relating to the detection, assessment, understanding, and prevention of drug-related problems. Over the lase decade, pharmacovigilance activities have contributed to the development of numerous technological and conventional advances focused on medication safety and regulatory intervention. The topics discussed include: 1) Proactive Pharmacovigilance; 2) A New Frontier; 3) Research Activities; 4) Project Purpose; 5) Methods; 6) Flight Stability Kit Components; 7) Experimental Conditions; 8) Research Project Logistics; 9) Research Plan; 10) Pharmaceutical Stability Research Project Pharmacovigilance Aspects; 11) Security / Control; 12) Packaging/Containment Actions; 13) Shelf-Life Assessments; 14) Stability Assessment Parameters; 15) Chemical Content Analysis; 16) Preliminary Results; 17) Temperature/Humidity; 18) Changes in PHysical and Chemical Assessment Parameters; 19) Observations; and 20) Conclusions.
NASA planetary protection, formerly planetary quarantine, is a set of regulations for extraterrestrial space missions which addresses applicable COSPAR resolutions, and ultimately derives from a 1967 United Nations treaty (the "Moon treaty"). The purpose of the NASA regulations is set forth in a basic policy, NPD 8020.7E (Ref. 1). The purposes are: to protect extraterrestrial objects from terrestrial biological contamination that may interfere with the search for extant life or its remnants or its precursors; and to protect the Earth from the possible hazards of an extraterrestrial sample return.