Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Modeling the Contribution of Precipitation Loss to a Radiation Belt Electron Dropout Observed by Van Allen Probes

A drift-diffusion model is used to simulate the low-altitude electron distribution, accounting for azimuthal drift, pitch angle diffusion, and atmospheric backscattering effects during a rapid electron dropout event on 21st August 2013, at L = 4.5. Additional external loss effects are introduced during times when the low-altitude electron distribution cannot be reproduced by diffusion alone. Here, the model utilizes low-altitude electron count rate data from five POES/MetOp satellites to quantify pitch angle diffusion rates. Low-altitude data provides critical constraint on the model because it includes the drift loss cone region where the electron distribution in longitude is highly dependent on the balance between azimuthal drift and pitch angle diffusion. Furthermore, a newly derived angular response function for the detectors onboard POES/MetOp is employed to accurately incorporate the bounce loss cone measurements, which have been previously contaminated by electrons from outside the nominal field-of-view. While constrained by low-altitude data, the model also shows reasonable agreement with high-altitude data. Pitch angle diffusion rates during the event are quantified and are faster at lower energies. Precipitation is determined to account for all of the total loss observed for 450 keV electrons, 88% for 600 keV and 38% for 900 keV. Predictions made in the MeV range are deemed unreliable as the integral energy channels E3 and P6 fail to provide the necessary constraint at relativistic energies.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-photon detection using high-temperature cuprate superconductors

The detection of individual quanta of light is important for quantum computation, fluorescence lifetime imaging, single-molecule detection, remote sensing, correlation spectroscopy, and more. Thanks to their broadband operation, high detection efficiency, exceptional signal-to-noise ratio, and fast recovery times, superconducting nanowire single-photon detectors (SNSPDs) have become a critical component in these applications. The operation of SNSPDs based on conventional superconductors, which have a low critical temperature (T c ), requires costly and bulky cryocoolers. This motivated exploration of other superconducting materials with higher T c that would enable single-photon detection at elevated temperatures, yet this task has proven exceedingly difficult. Here we show that with proper processing, high-T c cuprate superconductors can meet this challenge. We fabricated superconducting nanowires (SNWs) out of thin flakes of Bi 2 Sr 2 CaCu2O 8+δ and La 1.55 Sr 0.45 CuO 4 /La 2 CuO 4 (LSCO-LCO) bilayer films and demonstrated their single-photon response up to 25 and 8 K, respectively. The single-photon operation is revealed through the linear scaling of the photon count rate (PCR) on the radiation power. Both of our cuprate-based SNSPDs exhibited single-photon sensitivity at the technologically-important 1.5 μm telecommunications wavelength. Our work expands the family of superconducting materials for SNSPD technology, opens the prospects of raising the temperature ceiling, and raises important questions about the underlying mechanisms of single-photon detection by unconventional superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L

Abstract A NanoSIMS 50L is used to investigate uranium molecular ( 235 U 16 O, 236 U 16 O, 238 U 16 O, 235 U 1 H, 238 U 1 H, 236 U 16 O 1 H, and 238 U 16 O 1 H) and elemental ( 235 U, 236 U, and 238 U) secondary ion production during sputtering of synthetic UO 2 and the NIST-610 standard to determine if: (1) the 236 U 16 O/ 238 U 16 O molecular oxide ratio performs better than the 236 U/ 238 U elemental ratio, and (2) there is co-variance between the molecular hydrides and oxides. Despite an order of magnitude greater abundance of 236 U 16 O secondary ions (compared to 236 U), the 236 U 16 O/ 238 U 16 O ratios are less accurate than the 236 U/ 238 U ratios. Further work is needed before the higher count rate of the 236 U 16 O secondary ion can be used to obtain a better 236 U/ 238 U ratio. The second objective was undertaken because correction for the interference of 235 U 1 H on the 236 U secondary ion species typically utilizes the 238 U 1 H/ 238 U ratio. This becomes problematic in samples containing 239 Pu, so our aim was to understand if the hydride formation rate can be constrained independently of having to measure the 238 U 1 H. We document correlations between the hydride ( 238 U 1 H and 238 U 16 O 1 H) and oxide ( 236 U 16 O) secondary ions, suggesting that pursuing an alternative correction regime is worthwhile.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lithium-niobate-on-insulator waveguide-integrated superconducting nanowire single-photon detectors

Here, we demonstrate waveguide-integrated superconducting nanowire single-photon detectors on thin-film lithium niobate (LiNbO 3 , LN). Using a 250 μm-long NbN superconducting nanowire lithographically defined on top of a 125 μm-long LN nanowaveguide, an on-chip detection efficiency of 46% is realized with simultaneous high performance in dark count rates and timing jitter. As LN possesses high χ (2) second-order nonlinear and electro-optic properties, an efficient single-photon detector on thin-film LN opens up the possibility to construct a small-scale fully integrated quantum photonic chip, which includes single-photon sources, filters, tunable quantum gates, and detectors.

42 ENGINEERING↗

Investigating Quantum Materials with Half-Polarized Diffraction and magnetic PDF analysis at the HB-2A Neutron Powder Diffractometer

Local magnetic ordering and anisotropy is often central to the emergent behavior and subsequent functional properties in quantum materials and beyond. Neutron powder diffraction provides a straightforward yet extremely powerful technique for quantitative measurements of microscopic magnetic properties. The HB-2A powder diffractometer located at the High Flux Isotope Reactor in ORNL is traditionally utilized for long-range magnetic structure determination. Recently these capabilities have been extended to include methods aimed at accessing local magnetism: Half- polarized neutron powder diffraction (pNPD) and magnetic pair distribution function (mPDF) analysis. These two distinct techniques are possible on HB-2A due to the versatility of the instrument’s reciprocal space coverage, resolution and novel ultra-low temperature multi-sample changers that operate down to dilution refrigerator temperatures. This provides unique capabilities not found on any powder diffraction instrument and is particularly well suited to investigations of magnetic quantum materials. The development and implementation of these techniques will be discussed with a series of science case examples ranging from geometric frustrated magnets to magnetic metal-organic frameworks. Data reduction and analysis tools will be presented that enable the extraction of the local site susceptibility tensor and local spin-spin correlations in real space. Finally, potential combinations of these techniques in the form of half-polarized magnetic pair distribution function (pmPDF) analysis will be considered. Looking forward, HB-2A is undergoing a detector upgrade that will be in the user program by 2026. This will offer an order of magnitude increase in count rates to further aid the development of these often low signal measurements and provide new scientific capabilities.

Neutron Scattering↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Predicted performance of a tangential viewing hard x-ray camera for the DIII-D high field side lower hybrid current drive experiment

High field side launch of lower hybrid current drive (LHCD) has improved accessibility and penetration over low field side launch on DIII-D. Simulations predict single pass absorption under a wide range of plasma conditions. Hard x-ray (HXR) measurement of LHCD generated fast electron bremsstrahlung (50–250 keV) will validate wave propagation and absorption. Emissivity profiles are recovered from one-dimensional inversion of HXR brightness to determine LH damping location, fast electron slowing down time, and some indication of the fast electron energy. The camera will be implemented by populating 32 tangential sightlines of the existing Gamma Ray Imager with Kromek SPEARTM Cadmium Zinc Telluride (CZT) detectors sensitive to 10–1000 keV photons with 10 keV energy resolution. Expected count rates allow for <0.5 ms time resolution. Pulses are processed using 50 ns shaping time Cremat CR-200 Gaussian shaping modules and are digitized by 25 MHz D-TACQ ACQ216 digitizers. The performance of the HXR camera is evaluated by comparing predicted fast electron density profiles and inverted synthetic brightnesses obtained from the ray-tracing/Fokker–Planck codes GENRAY/CQL3D. Inversions closely matched predicted fast electron profiles for a range of experimental parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades to the gamma ray imager on DIII-D enabling access to high flux hard x-ray measurements during the runaway electron plateau phase (invited)

The Gamma Ray Imager (GRI) is a pinhole camera providing 2D imaging of MeV hard x-ray (HXR) bremsstrahlung emission from runaway electrons (REs) over the poloidal cross section of the DIII-D tokamak. We report a series of upgrades to the GRI expanding the access to RE scenarios from the diagnosis of a trace amount of REs to high flux HXR measurements during the RE plateau phase. We present the implementation of novel gamma ray detectors based on LYSO and YAP crystals coupled to multi-pixel photon counters, enabling a count rate in excess of 1 MHz. Finally, we highlight new insights into the RE physics discovered during the current quench and RE plateau phase experiments as the result of these upgrades.

Lvovskiy, A. (ORCID:0000000236491169)↗

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

Fragmentation dynamics of CS 2 dications and trications following S 2p ionization

Here, we present the results from a detailed study of the fragmentation dynamics of CS$_2^{2+}$ and CS$_2^{3+}$, formed in intense femtosecond soft x-ray pulses above the sulfur 2p edge, primarily through single core photoionization from the S 2p site, and subsequent Auger–Meitner decay(s). By combining three-dimensional velocity map imaging with covariance analysis, we determine the relative momenta of the ions produced in each two- and three-body fragmentation channel, at significantly higher ion count rates than conventional coincidence measurements. We shed new light on the wide range of fragmentation channels observed from the CS 2 dication and trication, including channels that involve ionization-induced bond formation and fragmentations producing undetected neutral cofragments. In the latter case, a “native frames” approach is used to isolate contributions from concerted and sequential fragmentations and extract dynamical information about each step of a concerted fragmentation process. While dications often fragment sequentially, the trication is dominated by concerted fragmentation. The main trication fragmentation channel into S + + C + + S + can be well-approximated by classical Coulombic simulations of the ground-state geometry distribution, reflecting both the nature of the trication potential energy surface and the rapid multiple ionization prior to substantial structural dynamics. This study demonstrates ways in which fundamental insights into the fragmentation dynamics of polycations following x-ray ionization may be extracted, which will be beneficial to future studies that employ time-resolved x-ray Coulomb explosion imaging to study ultrafast photochemistry.

Allum, Felix [Deutsches Elektronen-Synchrotron (DE↗

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of DIII-D experiments to diagnose the lifetime of spin polarized fuel

Abstract In magnetic fusion experiments, the cross sections for the D-T and D- 3 He fusion reactions are increased by as much as 50% if the fuel remains spin polarized parallel to the magnetic field. The goal of this study is to assess the feasibility of lifetime measurements of spin polarization, in magnetic fusion relevant conditions, on the DIII-D tokamak using relative changes in charged fusion product (CFP) loss measurements that depend upon the differential fusion cross section d σ /dΩ. Relative measurements that capture changes in the escaping CFP pitch, poloidal, and energy distributions are studied in two realistic TRANSP calculated plasma scenarios: (a) vector-polarized 3 He and D pellets are injected into a hot hydrogen plasma to produce thermonuclear reactions, and (b) a tensor-polarized deuterium pellet is injected into an L-mode hydrogen background plasma that includes unpolarized 3 He neutral beam injection. Ideal CFP signals in both scenarios show substantial pitch sensitivity to polarization for 14.7 MeV proton detection at a poloidal angle of − 56 ∘ (on the outer wall in the ion ∇ B direction), and strong sensitivity to polarization for 3.6 MeV alpha flux detection by an array of poloidal detectors. Energy-resolved measurements of 14.7 MeV protons are also sensitive to the degree of polarization for the − 56 ∘ port in the beam-plasma scenario. A realistic assessment of CFP signals in the thermonuclear scenario show count rates in the range of 2 × 10 4 cps for pitch-resolved proton detection and 2 × 10 5 cps for alpha flux measurements. Reduced chi-squared χ r 2 calculations show polarization lifetime measurements are feasible for either proton or alpha detection of both enhanced or suppressed polarization for the thermonuclear scenario. Measurements of gamma rays produced in the weak D + 3 He → γ + 5 Li branch complement the CFP measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

DAmodel: hierarchical Bayesian modelling of DA white dwarfs for spectrophotometric calibration

We use hierarchical Bayesian modelling to calibrate a network of 32 all-sky faint DA white dwarf (DA WD) spectrophotometric standards (⁠16.5 < V , 19.5⁠) alongside three CALSPEC standards, from 912 Å to 32 μm. The framework is the first of its kind to jointly infer photometric zero points and WD parameters (surface gravity log g⁠, effective temperature T eff ⁠, extinction A V ⁠, dust relation parameter R V ) by simultaneously modelling both photometric and spectroscopic data. We model panchromatic Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) UVIS and IR photometry, HST/STIS UV spectroscopy, and ground-based optical spectroscopy to sub-per cent precision. Photometric residuals for the sample are the lowest yet yielding < 0.004 mag RMS on average from the UV to the NIR, achieved by jointly inferring time-dependent changes in system sensitivity and WFC3/IR count-rate nonlinearity. Our GPU-accelerated implementation enables efficient sampling via Hamiltonian Monte Carlo, critical for exploring the high-dimensional posterior space. The hierarchical nature of the model enables population analysis of intrinsic WD and dust parameters. Inferred spectral energy distributions from this model will be essential for calibrating the James Webb Space Telescope as well as next-generation surveys, including Vera Rubin Observatory’s Legacy Survey of Space and Time and the Nancy Grace Roman Space Telescope.

methods: statistical↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗