A graphical test for checking the stability of a linear time-invariant feedback system.

A continuous-time scalar linear time-invariant feedback system is considered for the purpose of checking Willems' (1969, 1970) graphical test for a scalar linear time-invariant feedback system with constant feedback. Heavy reliance is placed on the theory of almost periodic functions. Following definition of the problem and layout of notation, attention is given to solution of the problem, considering only the almost periodic part of the open-loop transfer function.

Callier, F. M.↗

Detailed balance as a check on impact parameter calculations.

It is demonstrated numerically that detailed balance indeed is well satisfied in the multi-state impact parameter formulation of proton-hydrogen atom collisions. It is also demonstrated numerically that detailed balance is a much more sensitive test of computational accuracy than is the charge conservation test usually employed in such impact parameter calculations. It is suggested that detailed balance be used as a check on all impact parameter calculations. That even agreement with detailed balance may not be a sufficient test for accuracy of the results is pointed out.

Tai, H.↗

Liquid rocket pressure regulators, relief valves, check valves, burst disks, and explosive valves

The development of and operational programs for effective use in design are presented for liquid rocket pressure regulators, relief valves, check valves, burst disks, and explosive valves. A review of the total design problem is presented, and design elements are identified which are involved in successful design. Current technology pertaining to these elements is also described. Design criteria are presented which state what rule or standard must be imposed on each essential design element to assure successful design. These criteria serve as a checklist of rules for a project manager to use in guiding a design or in assessing its adequacy. Recommended practices are included which state how to satisfy each of the criteria.

Source record↗

Method and apparatus for checking the stability of a setup for making reflection type holograms

A method and apparatus are described for checking the stability of a setup for recording reflection-type (white light) holograms. Two sets of interference fringes are simultaneously obtained, one giving information about coherence and stability of the setup alone and the other demonstrating coherence of the entire system, including the holographic recording plate. Special emphasis is given to the stability of the plate, due to the fact that any minute vibration might severely degrade or completely destroy the recording.

Lackner, H. G.↗

Water system microbial check valve development

Development work on a device for the Space Shuttle that will prevent the transfer of viable microorganisms within water systems is described. The device serves as a check valve in that it prevents the transfer or cross-contamination of microorganisms from a nonpotable system into a potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the air gap found in conventional one gravity systems. The device is essentially a bed of resin material impregnated with iodine. Basic design data for a variety of flow and temperature conditions are presented, together with results of challenging the beds with suspensions of seven microorganisms including aerobes, anaerobes, and spore formers.

Colombo, G. V.↗

Water system microbial check valve development

A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

Colombo, G. V.↗

Microbial Check Valve for Shuttle

The Microbial Check Valve (MCV) is a device developed for the Space Shuttle that prevents the transfer of viable microorganisms within water systems. The device is essentially a bed of resin material, impregnated with iodine, that kills microorganisms on contact. It prevents the cross-contamination of microorganisms from a nonpotable system into the potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the 'air gap' found in conventional one-gravity systems. Basic design data are presented including pressure drop, scaling factors, sizing criteria, and the results of challenging the device with suspensions of seven microorganisms including aerobes, anaerobes and spore formers.

Colombo, G. V.↗

Fault tolerance using self-checking building-block computers

The paper attempts to define and characterize a set of VLSI (very large scale integration) building-block circuits which can be used to combine existing microprocessors and memories into a wide variety of fault-tolerant computing systems. Such VLSI circuits would transform fault-tolerant computing into an off-the-shelf technology and enable its routine use for new applications. The self-checking computer module (SCCM) is the basic component out of which fault-tolerant computer systems are constructed. Several fault-tolerant configurations of SCCM are discussed, including the standby redundant uniprocessor, the voted/hybrid uniprocessor, and the distributed computer network.

Rennels, D. A.↗

Flight manager and check-airman training

An analysis of industry incidents, accidents, and related human factors research is given. The need to develop more effective resource management training for the flight deck crewmembers is discussed with specific emphasis on flight manager and check-airman training.

Carroll, J. E.↗

Advanced microbial check valve development

A flight certified assembly identified as a Microbial Check Valve (MCV) was developed and tested. The MCV is a canister packed with an iodinated anionic exchange resin. The device is used to destroy organisms in a water stream as the water passes through the device. The device is equally effective for fluid flow in either direction and its primary method of organism removal is killing rather than filtering. The MCV was successfully developed for the space shuttle to: disinfect fuel cell water; and prevent back contamination of the stored potable water supply. One version of the device consists of a high residual iodinated resin bed that imparts approximately 2 ppm of iodine to the fuel cell water as it flows to the potable water tanks. A second version of the device consists of a low residual iodinated resin bed. One of these low residual beds is located at each use port in the potable water system for the dual purpose of removing some iodine from the potable water as it is dispensed and also to prevent back contamination of the potable supply.

Colombo, G. V.↗

Improved orthogonality check for measured modes

A method is proposed for performing an orthogonality check for normal modes derived from ground vibration testing. The method utilizes partitioned mass and stiffness matrices for a linear undamped representation of a structure. The normalization of the modes by the proposed method inherently includes the effects of significant displacements which were not measured; and the method may allow the use of fewer measurement points than would be necessary with the conventional method.

Berman, A.↗

User's manual for large-scale integrated circuit layout check program

A computer program is described that checks for the correctness of chip design layout generated by the Banning Placement Routing Folding program (PRF) by verifying agreement between a specified circuit design and a corresponding computer generated circuit layout as stored on the Artwork (PRF output) tape. An example computer run is included.

Source record↗

Jig Quickly Checks Connector Pin Alinement

Test jig checks whether pins of connector are within location tolerance. Jig greatly reduces test time. Machined slots on opposite faces of plate form matrix of rectangular windows at intersections. If connector pin is out of alinement, it makes electrical contact with side of window, triggering indicator.

Hall, W. M.↗

Advanced Microbial Check Valve development

The Microbial Check Valve (MCV) is a flight qualified assembly that provides bacteriologically safe drinking water for the Space Shuttle. The 1-lb unit is basically a canister packed with an iodinated ion-exchange resin. The device is used to destroy organisms in a water stream as the water passes through it. It is equally effective for fluid flow in either direction and its primary method of disinfection is killing rather than filtering. The MCV was developed to disinfect the fuel cell water and to prevent back contamination of stored potable water on the Space Shuttle. This paper reports its potential for space applications beyond the basic Shuttle mission. Data are presented that indicate the MCV is suitable for use in advanced systems that NASA has under development for the reclamation of humidity condensate, wash water and human urine.

Colombo, G. V.↗

Wind-Tunnel-Model Leak-Checking System

Voice-actuated system allows one operator to do work of three. System uses voice-recognition-and-response unit and graphics terminal to interact with technician and to provide technician visual feedback. Computer-based Leakcheck system allows computer to do more of total work in checking model for leaks to reduce time and manpower required to perform task.

Larson, W. E.↗