Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data eye”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Usability Evaluation of Indicators of Energy-Related Problems in Commercial Airline Flight Decks

A series of pilot-in-the-loop flight simulation studies were conducted at NASA Langley Research Center to evaluate indicators aimed at supporting the flight crew’s awareness of problems related to energy states. Indicators were evaluated utilizing state-of-the-art flight deck systems such as on commercial air transport aircraft. This paper presents results for four technologies: (1) conventional primary flight display speed cues, (2) an enhanced airspeed control indicator, (3) a synthetic vision baseline that provides a flight path vector, speed error, and an acceleration cue, and (4) an aural airspeed alert that triggers when current airspeed deviates beyond a specified threshold from the selected airspeed. Full-mission high-fidelity flight simulation studies were conducted using commercial airline crews. Crews were paired by airline for common crew resource management procedures and protocols. Scenarios spanned a range of complex conditions while emulating several causal factors reported in recent accidents involving loss of energy state awareness by pilots. Data collection included questionnaires administered at the completion of flight scenarios, aircraft state data, audio/video recordings of flight crew, eye tracking, pilot control inputs, and researcher observations. Questionnaire response data included subjective measures of workload, situation awareness, complexity, usability, and acceptability. This paper reports relevant findings derived from subjective measures as well as quantitative measures.

Evans, Emory T.↗

SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.

60 APPLIED LIFE SCIENCES↗

An Introduction to Data Visualization

Data visualization can be used to present findings, explore data, and use the human eye to find patterns that a computer would struggle to locate. Borrowing tools from art, storytelling, data analytics and software development, data visualization is an indispensable part of the analysis process. While data visualization usage spans across multiple disciplines and sectors, most never receive formal training in the subject. As such, this tutorial will introduce key data visualization building blocks and how to best use those building blocks for different scenarios and audiences. We will also go over tips on accessibility, design and interactive elements. While this will by no means be a complete overview of the data visualization field, by building a foundation and introducing some rules of thumb, attendees will be better equipped for communicating their findings to their audience.

data visualization↗

Interaction of the body, head, and eyes during walking and turning

Body, head, and eye movements were measured in five subjects during straight walking and while turning corners. The purpose was to determine how well the head and eyes followed the linear trajectory of the body in space and whether head orientation followed changes in the gravito-inertial acceleration vector (GIA). Head and body movements were measured with a video-based motion analysis system and horizontal, vertical, and torsional eye movements with video-oculography. During straight walking, there was lateral body motion at the stride frequency, which was at half the frequency of stepping. The GIA oscillated about the direction of heading, according to the acceleration and deceleration associated with heel strike and toe flexion, and the body yawed in concert with stepping. Despite the linear and rotatory motions of the head and body, the head pointed along the forward motion of the body during straight walking. The head pitch/roll component appeared to compensate for vertical and horizontal acceleration of the head rather than orienting to the tilt of the GIA or anticipating it. When turning corners, subjects walked on a 50-cm radius over two steps or on a 200-cm radius in five to seven steps. Maximum centripetal accelerations in sharp turns were ca.0.4 g, which tilted the GIA ca.21 degrees with regard to the heading. This was anticipated by a roll tilt of the head of up to 8 degrees. The eyes rolled 1-1.5 degrees and moved down into the direction of linear acceleration during the tilts of the GIA. Yaw head deviations moved smoothly through the turn, anticipating the shift in lateral body trajectory by as much as 25 degrees. The trunk did not anticipate the change in trajectory. Thus, in contrast to straight walking, the tilt axes of the head and the GIA tended to align during turns. Gaze was stable in space during the slow phases and jumped forward in saccades along the trajectory, leading it by larger angles when the angular velocity of turning was greater. The anticipatory roll head movements during turning are likely to be utilized to overcome inertial forces that would destabilize balance during turning. The data show that compensatory eye, head, and body movements stabilize gaze during straight walking, while orienting mechanisms direct the eyes, head, and body to tilts of the GIA in space during turning.

Non-NASA Center↗

Practice Patterns Analysis of Ocular Proton Therapy Centers: The International OPTIC Survey

Purpose: To assess the planning, treatment, and follow-up strategies worldwide in dedicated proton therapy ocular programs. Methods and Materials: Ten centers from 7 countries completed a questionnaire survey with 109 queries on the eye treatment planning system (TPS), hardware/software equipment, image acquisition/registration, patient positioning, eye surveillance, beam delivery, quality assurance (QA), clinical management, and workflow. Results: Worldwide, 28,891 eye patients were treated with protons at the 10 centers as of the end of 2014. Most centers treated a vast number of ocular patients (1729 to 6369). Three centers treated fewer than 200 ocular patients. Most commonly, the centers treated uveal melanoma (UM) and other primary ocular malignancies, benign ocular tumors, conjunctival lesions, choroidal metastases, and retinoblastomas. The UM dose fractionation was generally within a standard range, whereas dosing for other ocular conditions was not standardized. The majority (80%) of centers used in common a specific ocular TPS. Variability existed in imaging registration, with magnetic resonance imaging (MRI) rarely being used in routine planning (20%). Increased patient to full-time equivalent ratios were observed by higher accruing centers (P=.0161). Generally, ophthalmologists followed up the post–radiation therapy patients, though in 40% of centers radiation oncologists also followed up the patients. Seven centers had a prospective outcomes database. All centers used a cyclotron to accelerate protons with dedicated horizontal beam lines only. QA checks (range, modulation) varied substantially across centers. Conclusions: The first worldwide multi-institutional ophthalmic proton therapy survey of the clinical and technical approach shows areas of substantial overlap and areas of progress needed to achieve sustainable and systematic management. Future international efforts include research and development for imaging and planning software upgrades, increased use of MRI, development of clinical protocols, systematic patient-centered data acquisition, and publishing guidelines on QA, staffing, treatment, and follow-up parameters by dedicated ocular programs to ensure the highest level of care for ocular patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti‐lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post‐flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio‐ each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured

Otto, Christian↗

Out of the Corner of My Eye: Foveal Semantic Load Modulates Parafoveal Processing in Reading.

In two experiments, we examined the impact of foveal semantic expectancy and congruity on parafoveal word processing during reading. Experiment 1 utilized an eye-tracking gaze contingent display change paradigm, and Experiment 2 measured event-related brain potentials (ERP) in a modified RSVP paradigm to track the time-course of foveal semantic influences on convert attentional allocation to parafoveal word processing. Furthermore, eye-tracking and ERP data converged to reveal graded effects of semantic foveal load on parafoveal processing.

97 MATHEMATICS AND COMPUTING↗

DAP: Cosmic Plastics D33/6120 vs. Sumitomo Bakelite 52-01

As soon as you lay eyes on the two data sheets for these materials, Cosmic D33/6120 and Sumitomo Bakelite 52-01, there are some pretty clear differences in mechanical, thermal, electrical, and physical properties. There are three distinct hypotheses relating to why the plastics are so distinctly different from one another: 1. unique composition; 2. different molding procedure; and 3. separate molding parameters A closer look into each of these hypotheses is necessary in explaining why the Sumitomo Bakelite and Cosmic DAPs are so different from one another.

36 MATERIALS SCIENCE↗

Optical polarimetry of PKS 2155 - 304 and constraints on accretion disk models for BL Lacertae objects

Optical broad-band polarimetry and photometry of the BL Lacertae object PKS 2155 - 304 during late 1990 are presented. Variability in both flux and linear polarization was moderate during this period. The optical polarization ranged from 2 to 7 percent while photometric variations were within 0.2 mag (V = 13.2-13.4). Accurate multicolor measurements were made to study any wavelength dependence of the polarization with an eye to using these data to test the model of Wandel and Urry (1991) which proposes that the UV to soft X-ray continuum of this object arises from an accretion disk. Wavelength-dependent polarization (WDP) is observed in PKS 2155 - 304. However, the polarization is always seen to decrease with wavelength when WDP is observed. This is opposite to the expected sense of WDP if the UV continuum is dominated by an accretion disk.

Smith, Paul S.↗

Sources Sought for Innovative Scientific Instrumentation for Scientific Lunar Rovers

Lunar rovers should be designed as integrated scientific measurement systems that address scientific goals as their main objective. Scientific goals for lunar rovers are presented. Teleoperated robotic field geologists will allow the science team to make discoveries using a wide range of sensory data collected by electronic 'eyes' and sophisticated scientific instrumentation. rovers need to operate in geologically interesting terrain (rock outcrops) and to identify and closely examine interesting rock samples. Enough flight-ready instruments are available to fly on the first mission, but additional instrument development based on emerging technology is desirable. Various instruments that need to be developed for later missions are described.

Meyer, C.↗

Novel Co:MgF2 lidar for aerosol profiler

Lidars are of great interest because of their unique capabilities in remote sensing applications in sounding of the atmosphere, meteorology, and climatology. In this small business innovative research (SBIR) phase II program, laser sources including Co:MgF2, CTH:YAG, CTH:YSGG, CT:YAG, and Er:Glass were evaluated. Modulator of fused silica and TeO2 materials with Brewster's angle end faces were used with these lasers as acousto-optical (AO) Q-switches. A higher hold-off energy and hence a higher Q-switched energy was obtained by using a high power RF driver. The report provides performance characteristics of these lasers. The tunable (1.75-2.50 microns) Co:MgF2 laser damaged the TeO2 Q-switch cell. However, the CTH:YAG laser operating at 2.09 microns provided output energy of over 300 mJ/p in 50 ns pulse width using the fused silica Q-switch. This Q-switched CTH:YAG laser was used in a breadboard vertical aerosol profiler. A 40 cm diameter telescope, InSb and InGaAs detectors were used in the receiver. The data obtained using this lidar is provided in the report. The data shows that the eye safe lidar using CTH:YAG laser for the vertical aerosol density and range measurements is the viable approach.

Acharekar, M. A.↗

Remote Sensing for Farmers and Flood Watching

The Applied Sciences Directorate, part of NASA s Science Mission Directorate, makes use of the Agency s remote-sensing capabilities to acquire detailed information about our home planet. It uses this information for a variety of purposes, ranging from increasing agricultural efficiency to protecting homeland security. Sensors fly over areas of interest to detect and record information that sometimes is not even visible from the ground with the human eye. Scientists analyze these data for a variety of purposes and make maps of the areas. These maps are often used to answer questions about the environment, weather, natural resources, community growth, and natural disasters.

Source record↗

Looking into Ocular Risks of Spaceflight through the Mouse Retina

Ocular alterations have been observed at anatomical levels in astronauts on long duration spaceflight missions, such as what would be required for missions to Mars. These alterations cause an array of signs which together constitute the Spaceflight-Associated Neuro-ocular Syndrome (SANS), one of the top risk priorities of the NASA Human Research Program. Not much is known about SANS at the cellular and molecular level, but studies in mice and rats have recently begun to yield observations on how the spaceflight environment might affect the eye’s biology. Preliminary data from shuttle mouse experiments, and more recently experiments on ISS, have shown changes in retinal physiology via histology and gene expression analysis. This study utilizes samples from the CASIS sponsored Rodent Research 8 Experiment (RRRM-1) tissue sharing opportunity, delivered to the ISS by SpaceX CRS-16 on 12/08/2018. Female BALB/cAnNTac mice were on the ISS for 45 days, while ground controls consisted ofa standard vivarium group and spaceflight habitat group. Here we investigate the molecular response of the mouse retina to identify genes and pathways affected by spaceflight conditions using histology and transcriptomic RNAseq data. This Differentially Expressed Gene (DEG) data was used for pathway analysis with Galaxy (Genelab) and Ingenuity Pathway Analysis (IPA). We identified pathways related to neuronal differentiation, cellular transport/movement, and wound healing. Some of the top DEGs have known relation to ophthalmic diseases. Though there were DEGs throughout the comparisons we tested, there was no clear effect of spaceflight. This could be due to sample processing, which required mice to be returned to Earth about a day before they were sacrificed, possibly allowing for readaptation affecting the retinal transcriptome. However, there was a clear effect of age, between the young (10-12 weeks) and old (32 weeks) groups, and between the baseline and end of experiment, about 46 days.

SANS↗

Field Assessment of Sensorimotor Function Following Long-Duration Spaceflight

INTRODUCTION: Field assessments of functional task performance following long duration spaceflight are critical to characterize the risk associated with sensorimotor adaptation. A portable test battery involving sit-to-stand, prone-to-stand, walk and turn with obstacle, and tandem walking has been implemented during pre- and postflight testing to provide Sensorimotor Standard Measures that could be implemented in remote test locations. METHODS: To date, 19 astronauts (12 males, 7 females) participated in this study before and after 6–8-month expeditions to the International Space Station (198 ± 70 days, mean ±std). Ethics approvals were obtained, and all subjects provided informed consent. Tests were conducted preflight, within a few hours after landing, and then 1 day and 6–11 days later. Time to stability was the outcome measure for both standing tasks, time to completion and turn rate for the walk and turn task, and percent complete steps for the tandem walking (eyes open and closed). Statistical analyses included mixed effects (multi-level) generalized linear models. RESULTS: Consistent with previous Field Tests, significant effects of spaceflight were observed during the initial testing including longer times to stabilize posture when standing, longer times to complete the short obstacle walk, and fewer correct steps during tandem walking. The recovery timeline varied with task complexity, generally taking longer when either the basis of support was limited (e.g., tandem walk) and/or visual cues were deprived (eyes closed). DISCUSSION: These data suggest that additional sensorimotor-based countermeasures may be necessary to maintain functional performance during long-duration spaceflight. Maintaining core measures as new countermeasures are implemented during future missions will be instrumental in assessing their efficacy. This test battery will also serve as the basis for developing sensorimotor assessments during future space exploration.

Scott Jonathan Wood↗

Comparison of Active and Passive Head Impulse Testing of the Horizontal Vestibulo-Ocular Reflex: Exploring the Feasibility of Different Approaches for Spaceflight

INTRODUCTION: Astronauts experience a wide variety of sensorimotor disturbances primarily due to microgravity-induced vestibular adaptations during spaceflight. Head Impulse Testing (HIT) will be conducted during the Complement of Integrated Protocols for Human Exploration Research program(CIPHER) Vestibular Health study to examine changes in the horizontal vestibulo-ocular reflex in response to high-velocity head movements to detect changes in peripheral vestibular function [1,2]. However, correct interpretation will require consideration of potential artifacts and the constraints of conducting this test across different phases of the mission. Therefore, the aims of our study were to (1) examine reliability across different test operators, and (2) compare results of active (aHIT) versus passive (pHIT) approaches to evaluate the feasibility of self-administered versus operator-assisted approaches. A comparison of responses with visual viewing of a wall target (default condition) versus vision occluded evaluated the influence of other oculomotor control influence across conditions, and comparison with computer-generated rotator head impulse tests (rHIT) examined the variability associated with the ocular responses independent of the variability in executing the head movements themselves. METHODS: Seventeen non-astronaut volunteers (male n=12, age=22.9 ± 3.0; female n=5, age=27.0 ± 6.0, mean ± std) completed HIT testing using video-oculography (VOG) goggles and a high-torque rotator system. The test order was counterbalanced across conditions: (1) passive head-on-torso (pHIT, default condition for flight study) using two operators (Op1 and Op2), (2) active head-on-torso (aHIT, subject initiated), and (3) passive head and torso using rotary chair (rHIT). Eye and head movement data were processed to obtain gain in each direction. The main outcome measures were average gain and asymmetry [1], as well as the percentage of acceptable trials not excluded due to insufficient head amplitude or recording artifacts. RESULTS: While the pHIT gains were similar with vision (1.032 ± 0.043) and vision occluded (1.029 ± 0.038) conditions, the percentage of acceptable trials was greater with vision (Op1 = 93.0%, Op2 = 93.2%) versus occluded (Op1 = 70.7%, Op2 = 67.6%). The reliability between operators was greater for pHIT gain (Intraclass Correlation, ICC = 0.66, p = 0.001) than for pHIT asymmetry (ICC = 0.57, p = 0.01). The percentage of acceptable trials reduced by ~20% during the self-administered aHITs for both visual conditions and tended to be lower than computer-generated rHITs (76% versus 83%). While the aHIT gains were not significantly different than pHIT gains for vision or vision occluded conditions, these measures were poorly correlated. Both aHIT and pHIT gains were significantly greater than the rHIT gains, presumably due to the reduced velocities from the rotator. The asymmetry measures were poorly correlated across pHIT, aHIT, and rHIT conditions, although none of the subjects had asymmetries greater than 16%. DISCUSSION: Our findings support the feasibility of using the standard pHIT methodology for spaceflight. Similarities between visual conditions reflect that these responses are mediated by the peripheral lateral canals rather than other oculomotor mechanisms. The inter-tester reliability was acceptable despite differences in the tester training. In addition to concerns of non-vestibular mechanisms introduced during self-administered aHITs [2], operator-assisted pHITs resulted in higher percentage of acceptable trials and should result in more efficient and reliable measures during spaceflight.

M R Ehrenburg↗

Statistical evaluation of control inputs and eye movements in the use of instruments clusters during aircraft landing

Two different types of analyses were done on data from a study in which eye movements and other variables were recorded while four pilots executed landing sequences in a Boeing 737 simulation. Various conditions were manupulated, including changes in turbulence, starting position, and instrumentation. Control inputs were analyzed in the context of the various conditions and compared against ratings of workload obtained using the Cooper-Harper scale. A number of eye-scanning measures including mean dwell time and transition from one instrument to another were entered into a principal components factor analysis. The results show a differentiation between control inputs and eye-scanning behavior. This shows the need for improved definition of workload and experiments to uncover the important differences among control inputs, eye-scanning and cognitive processes of the pilot.

Dick, A. O.↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗

A Preliminary Development of The Intelligent Change Detection System (ICDS): Using Machine Learning to Combat Change Blindness in Remote Operation Environments

The emergence of Advance Air Mobility (AAM) will increase the number and types of aerial vehicles operating in shared airspaces, which will subsequently affect the amount of actionable data that ground control station operators (GCSOs) will be expected to manage. In this environment, GCSOs are particularly susceptible to the visual perceptual phenomenon known as change blindness, in which a stimulus undergoes a change without the change being noticed by its observer. A machine agent designed to detect change blindness and mitigate the effects could improve human agent performance in a data-saturated remote operations environment. The objective of this paper is to describe a proof-of-concept system architecture that integrates real-time eye tracking and vehicle telemetry data to prevent human-agent errors resulting from change blindness while operating aircraft from a remote ground control station (GCS).

Real-Time Streaming Data Architecture↗