Search NASA⌕ Search

SEARCH · Search NASA

Results for “ECCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demonstration of CFD to support the coupled analysis of a reactor pressure vessel subjected to pressurized thermal shock

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended duration or under accident condition. As one of the most significant components of a reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Aging degradation mechanisms (e.g. thermo-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The prediction of the temperature field is achieved by using computational fluid dynamics (CFD) simulation. In this report, a demonstration CFD standalone simulation is performed to support coupled analysis for Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS). The study use a simplified computational domain to represents a real RPV. The purpose of the study is to demonstrate the transient temperature response of RPV to ECC injection. The CFD model is built in a robust and efficient way for further coupled calculation. The next steps of this work, including the coupled thermal and tensor mechanics capabilities using Cardinal are expected to be complete by the end of FY21 for the demo problem. After this, into FY22, the capability will be demonstrated for a realistic RPV.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation and Analysis on Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS) under SBLOCA scenario by using Cardinal to support the fracture mechanics analyses

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended durations or under accident condition. As one of the most significant components of a Reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Ageing degradation mechanisms (e.g. thermos-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The multi-physics simulations are performed using Cardinal, a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and other multi-physics sub-modules within the MOOSE framework. Cardinal now fully supports MOOSE stochastic perturbations of NekRS models with varying boundary conditions, initial conditions, material properties, and any other quantity which is defined by a kernel (such as coefficients in a momentum source model). The implementation is designed in a flexible manner so that scalar values are sent from MOOSE into a user scratch space in NekRS, which can then be applied for any purpose within the NekRS case files (both on the host and device). When modeling PTS, several factors can impact the results significantly. In this report, the impacts of the geometry of the model, Reynolds number and buoyancy effect are investigated. Two geometry, i.e., a simplified model and a realistic RPV model, with both laminar and turbulent flow condition are adopted for the PTS simulation with and without buoyancy effect. The purpose of the investigation is to understand the impact of these factors on the prediction of temperature history of RPV. The accurate prediction on the temperature evolution, which will be exported to Grizzly code for further analyses on the progression of aging mechanisms and their effects on the integrity of RPV structures, is very crucial. Based on the understanding of these factors, a more sophisticated model is built to analysis the PTS under SBLOCA scenario. A literature survey is conducted to pick the SBLOCA scenario for the multi-physics simulation. The analysis helps to explain the form and the transformation of the cold plum when the ECC is activated under SBLOCA. This model can be can be applied to study the PTS effect for different RPV configurations. The results can help to assess structural component degradation for advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emerald Connections Weatherization Plus Health Pilot Program

The Emerald Connections Weatherization Plus Health Pilot Program (Healthy Homes Pilot or the pilot), delivered 97 comprehensive energy retrofits to low-income households in two underserved communities: Lynn, Massachusetts (57) and the Beacon Hill neighborhood in Seattle, Washington (40). Designed by Emerald Cities Collaborative (ECC) and funded via a U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) Enhancement and Innovation (E&I) grant, ECC created the pilot to expand the reach and range of services typically available to participating WAP households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ACTUAL-WASTE TESTS OF ENHANCED CHEMICAL CLEANING FOR RETRIEVAL OF SRS HLW SLUDGE TANK HEELS AND DECOMPOSITION OF OXALIC ACID

Savannah River National Laboratory conducted a series of tests on the Enhanced Chemical Cleaning (ECC) process using actual Savannah River Site waste material from Tanks 5F and 12H. Testing involved sludge dissolution with 2 wt% oxalic acid, the decomposition of the oxalates by ozonolysis (with and without the aid of ultraviolet light), the evaporation of water from the product, and tracking the concentrations of key components throughout the process. During ECC actual waste testing, the process was successful in decomposing oxalate to below the target levels without causing substantial physical or chemical changes in the product sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Error-correction coding for hot-swapping semiconductor devices

A memory read operation is directed at a group of semiconductor devices from which a first semiconductor device has been removed. An error in data for the memory read operation is detected based on error-correction coding (ECC). The error is caused at least in part by the first semiconductor device having been removed. ECC is used to determine corrected data for the memory read operation.

42 ENGINEERING↗

Passive techniques for long-term reactor cooling

In a pressurized water reactor (PWR), emergency core cooling (ECC) responds to depressurization due to a vessel penetration break at the top of the pressure vessel by draining water from a body of water through an injection line into the pressure vessel. A barrier operates concurrently with the ECC to suppress flow of liquid water from the pressure vessel out the vessel penetration break. The barrier may comprise one or more of: (1) an injection line extension passing through the central riser to drain water into the central riser; (2) openings in a lower portion of a central riser to shunt some upward flow from the central riser into a lower portion of the downcomer annulus; and (3) a surge line providing fluid communication between a pressurizer volume at the top of the pressure vessel and the remainder of the pressure vessel which directs water outboard toward the downcomer annulus.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive techniques for long-term reactor cooling

In a pressurized water reactor (PWR), emergency core cooling (ECC) responds to depressurization due to a vessel penetration break at the top of the pressure vessel by draining water from a body of water through an injection line into the pressure vessel. A barrier operates concurrently with the ECC to suppress flow of liquid water from the pressure vessel out the vessel penetration break. The barrier may comprise one or more of: (1) an injection line extension passing through the central riser to drain water into the central riser; (2) openings in a lower portion of a central riser to shunt some upward flow from the central riser into a lower portion of the downcomer annulus; and (3) a surge line providing fluid communication between a pressurizer volume at the top of the pressure vessel and the remainder of the pressure vessel which directs water outboard toward the downcomer annulus.

Malloy, III, John D.↗

Rethinking of Zircaloy Embrittlement Criteria for Improving Safety Margin of Light Water Reactor

Zircaloy embrittlement criteria have become a basis for the current emergency core cooling system (ECCS) criteria to maintain the coolable geometry. U.S. NRC has considered that retaining adequate cladding ductility is a simple and effective way for ensuring the structural integrity of fuel rods under the accident conditions. Considering this, the current ECCS criteria limits the peak cladding temperature(PCT) to be 1204 deg. C, and equivalent cladding reacted (ECR) to be 17%, calculated by the Baker-Just equation. However, the criteria were established based on the experimental investigations in early 1970's and it has inevitably limitations, in particular, about hydrogen embrittlement with burnup. As a consequence, the new draft-rule proposes a relation that gives rise to a decreasing ECR limit with respect to pre-transient hydrogen content by U.S NRC. The regulation of Japan is quite different from that of U.S. NRC. This rule is set to assure structural integrity of ruptured fuel rods upon water-quenching. Recently, Japanese Atomic Energy Agency (JAEA) conducted integral fuel rod thermal shock tests with high burnup claddings. These investigations confirmed that the original criteria (PCT 1200 deg. C, ECR 15% calculated by Baker-Just equation ) still successfully guarantee fuel rod structural integrity upon thermal shock and concluded that the high-burnup effects are inconsiderable as the thermal-shock fracture boundary is not significantly reduced. Hence, there exists an obvious disagreement between the embrittlement-based and the thermal shock fracture-based criterion particularly when it comes to the high burnup consideration. The one of them can be adopted to define safety limit and safety margin which is the difference between the regulation limit and actual value of the parameter. Also, it is worth noting that the temperature limit (1204 deg. C) of the Zircaloy embrittlement criteria has not been altered since it was first determined in 1970's. Such a qualitative concern alone should not limit further discussions on the potential increase in the temperature limit. Indeed, there is ample experimental evidence that supports the possibility that Zircaloy ductility can be maintained beyond 1204 deg. C if it is oxidized for a limited time period. The increase in the temperature margin can lead to a reactor power uprate, or allow an increased accident coping time. This paper aims to achieve a comprehensive understanding of an engineering compatibility between nuclear fuel behaviors, safety system, and safety criteria, in the pursuit of increasing safety margin of LWRs. Specifically, this study presents a revision the current temperature limit (1204 deg. C) with adjustable ECR levels through an extensive literature review. And the impact of this temperature limit on the actual design basis accident margin is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Chemical Cleaning: A New Process for Chemically Cleaning Savannah River Waste Tanks

At the Savannah River Site (SRS) there are 49 High Level Waste (HLW) tanks that eventually must be emptied, cleaned, and closed. The current method of chemically cleaning SRS HLW tanks, commonly referred to as Bulk Oxalic Acid Cleaning (BOAC), requires about a half million liters (130,000 gallons) of 8 weight percent (wt%) oxalic acid to clean a single tank. During the cleaning, the oxalic acid acts as the solvent to digest sludge solids and insoluble salt solids, such that they can be suspended and pumped out of the tank. Because of the volume and concentration of acid used, a significant quantity of oxalate is added to the HLW process. This added oxalate significantly impacts downstream processing. In addition to the oxalate, the volume of liquid added competes for the limited available tank space. A search, therefore, was initiated for a new cleaning process. Using TRIZ (Teoriya Resheniya Izobretatelskikh Zadatch or roughly translated as the Theory of Inventive Problem Solving), Chemical Oxidation Reduction Decontamination with Ultraviolet Light (CORD-UV{reg_sign}), a mature technology used in the commercial nuclear power industry was identified as an alternate technology. Similar to BOAC, CORD-UV{reg_sign} also uses oxalic acid as the solvent to dissolve the metal (hydr)oxide solids. CORD-UV{reg_sign} is different, however, since it uses photo-oxidation (via peroxide/UV or ozone/UV to form hydroxyl radicals) to decompose the spent oxalate into carbon dioxide and water. Since the oxalate is decomposed and off-gassed, CORD-UV{reg_sign} would not have the negative downstream oxalate process impacts of BOAC. With the oxalate destruction occurring physically outside the HLW tank, re-precipitation and transfer of the solids, as well as regeneration of the cleaning solution can be performed without adding additional solids, or a significant volume of liquid to the process. With a draft of the pre-conceptual Enhanced Chemical Cleaning (ECC) flowsheet, taking full advantage of the many CORD-UV{reg_sign} benefits, performance demonstration testing was initiated using available SRS sludge simulant. The demonstration testing confirmed that ECC is a viable technology, as it can dissolve greater than 90% of the sludge simulant and destroy greater than 90% of the oxalates. Additional simulant and real waste testing are planned.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation of reflooding on two parallel heated channel by TRACE

In case of Loss-Of-Coolant accident (LOCA) in a Boiling Water Reactor (BWR), heat generated in the nuclear fuel is not adequately removed because of the decrease of the coolant mass flow rate in the reactor core. This fact leads to an increase of the fuel temperature that can cause damage to the core and leakage of the radioactive fission products. In order to reflood the core and to discontinue the increase of temperature, an Emergency Core Cooling System (ECCS) delivers water under this kind of conditions. This study is an investigation of how the power distribution between two channels can affect the process of reflooding when the emergency water is injected from the top of the channels. The peak cladding temperature (PCT) on LOCA transient for different axial level is determined as well. A thermal-hydraulic system code TRACE has been used. A TRACE model of the two heated channels has been developed, and three hypothetical cases with different power distributions have been studied. Later, a comparison between a simulated and experimental data has been shown as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Industry Application Emergency Core Cooling System Cladding Acceptance Criteria Early Demonstration

The U. S. NRC is currently proposing rulemaking designated as “10 CFR 50.46c” to revise the loss-of-coolant-accident (LOCA)/emergency core cooling system (ECCS) acceptance criteria to include the effects of higher burnup on cladding performance as well as to address other technical issues. The NRC is also currently resolving the public comments with the final rule expected to be issued in April 2016. The impact of the final 50.46c rule on the industry may involve updating of fuel vendor LOCA evaluation models, NRC review and approval, and licensee submittal of new LOCA evaluations or re-analyses and associated technical specification revisions for NRC review and approval. The rule implementation process, both industry and NRC activities, is expected to take 4-6 years following the rule effective date. As motivated by the new rule, the need to use advanced cladding designs may be a result. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently, there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin. The proposed rule would apply to a light water reactor and to all cladding types.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiological Impact Assessment (RIA) following a postulated accident in PHWRS

Radiological Impact Assessment (RIA) following postulated accident i.e Loss of Coolant Accident (LOCA) with failed Emergency Core Cooling System (ECCS), performed as part of the reactor safety analysis of a typical 700 MWe Indian Pressurized Heavy Water Reactor(PHWR). The rationale behind the assessment is that the public needs to be protected in the event that the postulated accident results in radionuclide release outside containment. Radionuclides deliver dose to the human body through various pathways namely, plume submersion, exposure due to ground deposition, inhalation and ingestion. The total exposure dose measured in terms of total effective dose equivalent (TEDE) is the sum of doses to a hypothetical adult human at exclusion zone boundary by all the exposure pathways. The analysis provides the important inputs to decide upon the type of emergency counter measures to be adopted during the postulated accident. The importance of the various pathways in terms of contribution to the total effective dose equivalent(TEDE) is also assessed with respect to time of exposure. Inhalation and plume gamma dose are the major contributors towards TEDE during initial period of accident whereas ingestion and ground shine dose start dominating in TEDE in the extended period of exposure. Moreover, TEDE is initially dominated by I-131, Kr-88, Te-132, I-133 and Sr-89, whereas, as time progresses, Xe-133,I-131 and Te-132 become the main contributors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental investigation on the chemical precipitation generation under the loss of coolant accident of nuclear power plants

The PWR containment buildings are designed to facilitate core cooling in the event of a Loss of Coolant Accident (LOCA). The cooling process requires water discharged from the break and containment spray to be collected in a sump for recirculation. The containment sump contains screens to protect the components of the Emergency Core Cooling System (ECCS) and Containment Spray System (CSS) from debris. Since the containment materials may dissolve or corrode when exposed to the reactor coolant and spray solutions, various chemical precipitations can be generated in a post-LOCA environment. These chemical precipitations may become another source of debris loading to be considered in sump screen performance and downstream effects. In this study, new experimental methodology to predict the type and quantity of chemical precipitations has been developed. To generate the plant-specific chemical precipitation in a post-LOCA environment, the plant specific chemical condition of the recirculation sump during post-LOCA is simulated with the experimental reactor for the chemical effect. The plant-specific containment materials are used in the present experiment such as glass fibers, concrete blocks, aluminum specimens, and chemical reagent - boric acid, spray additives or buffering chemicals (sodium hydroxide, Tri-Sodium Phosphate (TSP), or others). The inside temperature of the reactor is controlled to simulate the plant-specific temperature profile of the recirculation sump. The total amount of aluminum released from aluminum specimens is evaluated by ICP-AES analysis to determine the amount of AlOOH and NaAlSi{sub 3}O{sub 8} which induce very adverse effect on the head loss across the sump screens. The amount of these precipitations generated in the present experimental study is compared with the results of WCAP-16530-NP-A. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of 1% hot leg SBLOCA with TRACE5

During a Small Break Loss-of-Coolant Accident (SBLOCA) transient, depressurization can be slow enough to delay the Accumulators (ACC) entry for a long time. Actuation of High Pressure Injection (HPI) system is then necessary in order to maintain the core temperature low enough to avoid core boil off, and consequently avoiding the core level to fall below fuel rods level, thus producing a temperature trip in the fuel cladding. In this frame, the OECD/NEA ROSA Project Test 1.2 (SB-HL-17 in Japan Atomic Energy Agency (JAEA)) has been simulated using the thermal-hydraulic code TRACES. Test 1.2 was performed in the Large Scale Test Facility (LSTF) reproducing a 1% hot leg SBLOCA in a Pressurized Water Reactor (PWR). A comparison between experimental and the main simulated variables was performed to study the effect of important parameters (liquid stratification, geometry and size) to model the break. Finally, in an Emergency Core Cooling System (ECCS) failure scenario, loss of coolant is large enough to produce core boil-off and a Peak Cladding Temperature (PCT) excursion. With this purpose a sensitivity analysis varying the HPI mass flow rate has been performed covering the range between HPI actuation and failure. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Alternatives for Dismantling of the Equipment in Building 117/1 at Ignalina NPP - 13278

Ignalina NPP was operating two RBMK-1500 reactors which are under decommissioning now. In this paper dismantling alternatives of the equipment in Building 117/1 are analyzed. After situation analysis and collection of the primary information related to components' physical and radiological characteristics, location and other data, two different alternatives for dismantling of the equipment are formulated - the first (A1), when major components (vessels and pipes of Emergency Core Cooling System - ECCS) are segmented/halved in situ using flame cutting (oxy-acetylene) and the second one (A2), when these components are segmented/halved at the workshop using CAMC (Contact Arc Metal Cutting) technique. To select the preferable alternative MCDA method - AHP (Analytic Hierarchy Process) is applied. Hierarchical list of decision criteria, necessary for assessment of alternatives performance, are formulated. Quantitative decision criteria values for these alternatives are calculated using software DECRAD, which was developed by Lithuanian Energy Institute Nuclear engineering laboratory. While qualitative decision criteria are evaluated using expert judgment. Analysis results show that alternative A1 is better than alternative A2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRACE Code Validation of BWR SVEA Fuel Assembly Spray Cooling

Emergency spray cooling injection is a safety feature implemented in many boiling water reactor designs to reflood a reactor during an accident. Significant experimental work has qualified the efficacy of spray cooling, and ongoing computational modeling efforts strive to more accurately portray the phenomena involved. This work examines the physical phenomena pertaining to emergency spray cooling injection over SVEA-type fuel assemblies. BWR emergency core cooling system (ECCS) designs commonly incorporate a Low-Pressure Core Spray (LPCS) system that introduces coolant through spray nozzles directed to the top of the core, and are located in the upper plenum region. This design is effective for LOCA response, particularly during the initial refill and reflood stages of accident response where the goal is limiting the peak cladding temperature rise in the core. The U.S. NRC thermal-hydraulics code TRACE version 5.0 Patch 4 has been chosen to simulate the separate-effect tests performed by ASEA-ATOM. The computational model was evaluated by performing forward uncertainty quantification using Dakota as the analysis tool and code driver on 31 identified parameters from the input model and TRACE physical constitutive models. This paper discusses the sensitivity of the investigated parameters with respect to spray cooling simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Shuffling and Fuel Management Capability in PHISICS code

PHISICS (Parallel and Highly Innovative Simulation for the INL Code System) code is a reactor physics package, under development at the Idaho National Laboratory since few years ago. This package is aimed to provide a modern analysis and design tool for reactor physics investigation. It has been designed with the idea to maximize accuracy for a given availability of computational resources and to give state of the art tools and advanced solutions to the nuclear engineer. This is obtained through the implementation of several different solution algorithms and meshing approaches among which the user will be able to choose, in order to balance his computational resources and accuracy needs. PHISICS has been coded following an object-oriented mindset, evolving in a complete modular design; this determines remarkable simplifications in the development of modules by different teams and future maintenance. The different modules currently available in the PHISICS package are a nodal and semi-structured transport core solver (INSTANT), a depletion and burn-up module (MRTAU), a time-dependent solver (Time Integrator), a cross section interpolation and manipulation framework (MIXER), a criticality search module (Criticality) and a fuel management and shuffling component (Shuffle), which is the subject of this paper, having been recently redesigned and improved. PHISICS is fully parallelized to take advantage of multi-core workstations and High Performance Computing systems (4 to 500 cores). In addition, the package is coupled with the system safety analysis code RELAP5-3D. Using the coupling between PHISICS and RELAP5-3D is possible to drive a accurate dynamic analysis switching between a steady state and time-dependent calculations. The main purpose of this paper is to present the redesigned module Shuffle, within the PHISICS tool-kit. All the functionality limitations of the old design have been faced and resolved. The functionality of the module has been fully tested and represented a key development in order to face a challenging problems, such as the revision of the requirements in 10 CFR 50.46C rules, focused on the ECCS rule in LOCA scenarios. The renovated Shuffle module is now completed and represents a key feature of the PHISICS for fuel cycle studies and optimization. Currently it is possible to perform multi-cycle full core analysis including accounting for the thermal-hydraulic feedback by the coupling with RELAP-5. (authors)

97 MATHEMATICS AND COMPUTING↗

Estimation of LOCA break size using cascaded support vector regression - 334

A failure of emergency core cooling system (ECCS) during a certain small break loss of coolant accident (SBLOCA) can cause a severe core uncovery and fuel failure. The safety injection systems (SISs) might not function properly in case of a SBLOCA, due to the slight change of pressure in the pipes. Early trend of the major parameters has to be observed and the accurate information has to be given to the nuclear power plant (NPP) operators by precisely identifying the break size to effectively manage accidents. In this study, the objective is to provide to operators the information on the break size in a short time by considering the accident situations such as hot-leg LOCA, cold-leg LOCA, steam generator tube rupture (SGTR). A cascaded support vector regression (CSVR) is used in order to estimate the break size. The simulation data set was obtained from the optimized power plant reactor 1000 (OPR1000) using modular accident analysis program (MAAP) code. And genetic algorithm (GA) was used to select the input variables of the CSVR model and optimize its parameters. As a result of this study, the CSVR model estimate very well the break size of LOCAs. If the operators can predict the break size in the LOCA, they can response quickly and properly to LOCA circumstances to prevent the core uncovery and fuel failure. Also, it will be possible to more efficiently manage beyond design basis accidents. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗