Correlation of wind-tunnel predictions with flight tests of a twin-engine patrol airplane II : lateral- and directional-stability and control characteristics
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An investigation of cowlings for long-nose radial engines was made on the Curtiss XP-42 fighter in the NACA full-scale wind tunnel. The unsatisfactory aerodynamic characteristics of all the cowlings with scoop inlets tested led to the development of the annular high-velocity inlet cowlings. Tests showed that ratio of cooling-air velocity at cowling inlet to stream velocity should not be less than 0.5 for this type of cowling and that critical compressibility speed can be extended to more than 500 mph at 20,000 ft altitude.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In order to provide engineers interested in rotating-wing aircraft, but with no specialized training in stability theory, some understanding of the factors that influence the flying qualities of the helicopter, an explanation is made of both the static stability and the stick-fixed oscillation in hovering and forward flight in terms of fundamental physical quantities. Three significant stability factors -- static stability with angle of attack, static stability with speed, and damping due to a pitching or rolling velocity -- are explained in detail.
The advent of exascale supercomputers heralds a new era of scientific discovery, yet it introduces significant architectural challenges that must be overcome for MPI applications to fully exploit its potential. Among these challenges is the adoption of heterogeneous architectures, particularly the integration of GPUs to accelerate computation. Additionally, the complexity of multithreaded programming models has also become a critical factor in achieving performance at scale. The efficient utilization of hardware acceleration for communication, provided by modern NICs, is also essential for achieving low latency and high throughput communication in such complex systems. In response to these challenges, the MPICH library, a high-performance and widely used Message Passing Interface (MPI) implementation, has undergone significant enhancements. Here, this paper presents four major contributions that prepare MPICH for the exascale transition. First, we describe a lightweight communication stack that leverages the advanced features of modern NICs to maximize hardware acceleration. Second, our work showcases a highly scalable multithreaded communication model that addresses the complexities of concurrent environments. Third, we introduce GPU-aware communication capabilities that optimize data movement in GPU-integrated systems. Finally, we present a new datatype engine aimed at accelerating the use of MPI derived datatypes on GPUs. These improvements in the MPICH library not only address the immediate needs of exascale computing architectures but also set a foundation for exploiting future innovations in high-performance computing. By embracing these new designs and approaches, MPICH-derived libraries from HPE Cray and Intel were able to achieve real exascale performance on OLCF Frontier and ALCF Aurora respectively.
The requirements engineering phase of software development projects is characterized by the intensity and importance of communication activities. During this phase, the various stakeholders must be able to communicate their requirements to the analysts, and the analysts need to be able to communicate the specifications they generate back to the stakeholders for validation. This paper describes a field investigation into the problems of communication between disparate communities involved in the requirements specification activities. The results of this study are discussed in terms of their relation to three major communication barriers: (1) ineffectiveness of the current communication channels; (2) restrictions on expressiveness imposed by notations; and (3) social and organizational barriers. The results confirm that organizational and social issues have great influence on the effectiveness of communication. They also show that in general, end-users find the notations used by software practitioners to model their requirements difficult to understand and validate.
An equation is presented for calculating the heat flow required from the surface of an internally heated windshield in order to prevent the formation of ice accretions during flight in specified icing conditions. To ascertain the validity of the equation, comparison is made between calculated values of the heat required and measured values obtained for test windshields in actual flights in icing conditions. The test windshields were internally heated and provided data applicable to two common types of windshield configurations; namely the V-type and the type installed flush with the fuselage contours. These windshields were installed on a twin-engine cargo airplane and the icing flights were conducted over a large area of the United States during the winters of 1945-46 and 1946-47. In addition to the internally heated windshield investigation, some test data were obtained for a windshield ice-prevention system in which heated air was discharged into the windshield boundary layer. The general conclusions resulting from this investigation are as follows: 1) The amount of heat required for the prevention of ice accretions on both flush- and V-type windshields during flight in specified icing conditions can be calculated with a degree of accuracy suitable for design purposes. 2) A heat flow of 2000 to 2500 Btu per hour per square foot is required for complete and continuous protection of a V-type windshield in fight at speeds up to 300 miles per hour in a moderate cumulus icing condition. For the same degree of protection and the same speed range, a value of 1000 Btu per hour per square foot suffices in a moderate stratus icing condition. 3) A heat supply of 1000 Btu per hour per square foot is adequate for a flush windshield located well aft of the fuselage stagnation region, at speeds up to 300 miles per hour, for flight in both stratus and moderate cumulus icing conditions. 4) The external air discharge system of windshield thermal ice prevention is thermally inefficient and requires a heat supply approximately 20 times that required for an internal system having the same performance.