Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗

Radiation damage of a two-dimensional carbon fiber composite (CFC)

Carbon fiber composites (CFC) are, among other applications, already in use as low-impedance collimating elements for intercepting TeV-level protons machines, like the CERN Large Hadron Collider. Towards a comprehensive understanding of these materials’ properties and behavior, a series of radiation damage campaigns have been undertaken in order to quantitively investigate the response of AC-150 K CFC to high proton fluences. The CFCs dimensional changes, stability, micro-structural evolution, and structural integrity below and above 5 × 10 20 p/cm 2 fluence threshold were studied. The irradiating particles were protons of kinetic energies in the range of 130–200 MeV. The effects of the irradiation temperature (~90–180°C and 280–500°C) combined with the proton fluence on the dimensional stability and the microstructural evolution of this anisotropic two-dimensional composite structure were studied using precision dilatometry and X-ray diffraction. Our results shed light on the fluence-based limitations for these composite materials. Furthermore, we compare these results with reference unirradiated graphite, and we discuss the similarities and differences in the dimensional changes and post-irradiation annealing properties.

36 MATERIALS SCIENCE↗

A quantitative study of retention and release of deuterium and tritium during irradiation of y-LiAlO2 pellets

This study reports on the quantification of deuterium in ion-irradiated gamma-LiAlO2 pellets as a function of dose and temperature. The gamma-LiAlO2 pellets were sequentially irradiated with He+ and D2+ ions to the same fluences of 5E16, 1E17 and 2E17 He++D+/cm2 at 188 K. Additional irradiation was performed to 1E17, 2E17 and 4E17 He++D+/cm2 at 573 K. A set of the pellets irradiated at 188 K was shipped and stored at low temperatures from 80 to 132 K and characterized using time-of-flight secondary ion mass spectrometry at ~173 K. The deuterium depth profiles show a Gaussian-like distribution in the low-temperature pellets. The total deuterium retention is found to be directly proportional to the ion fluence. About 27 at.% of the implanted deuterium atoms were released from the pellet irradiated to 2E17 He++D+/cm2 at 188 K during storage at room temperature for ~1 month. Retention of the trapped or bound deuterium during ion irradiation at 573 K increases initially with ion fluence and tends to saturate at a high fluence. The amount of the released deuterium is observed to be quantitatively consistent with that of the released tritium from similar standard pellets during neutron irradiation at 573 K.

Deuterium retention and release, ion irradiation, ↗

Cluster dynamics modeling of Mn-Ni-Si precipitates coupled with radiation-induced segregation in low-Cu reactor pressure vessel steels

Formation of precipitates enhanced or induced by irradiation causes hardening and embrittlement of nuclear structural materials. Post-irradiation microstructure characterization of reactor pressure vessel (RPV) steels has shown that precipitation can be strongly associated with radiation-induced segregation (RIS) of solutes on dislocations. However, RIS and precipitation have not been coupled in previous precipitation modeling of RPV steels. Here in this study, a new hybrid and spatially-dependent precipitation model is developed that couples cluster dynamics with RIS, providing an unique way to account for concurrent evolution of heterogeneous cluster densities as well as solute and point defect concentration profiles. The model is applied to study the segregation of Mn, Ni, and Si on dislocations and heterogeneous nucleation of Mn-Ni-Si rich precipitates (MNSPs) in a low-Cu RPV steel. The result shows that the onset of MNSP nucleation on dislocations occurs at the fluence of 2 x 10 23 n.m -2 . The number density and mean radius can reach ~ 10 24 m -3 and 1-2 nm at high fluence, respectively. These observations suggest that the role of RIS and heterogeneous nucleation can be significant for RPV steels under a high fluence of irradiation. Results of simulations adopting various dose rates and dislocation densities show an increased fraction of MNSPs on dislocations at the condition of low dose rate, high dislocation density, and high fluence.

36 MATERIALS SCIENCE↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced magnetization in proton irradiated Mn 3 Si 2 Te 6 van der Waals crystals

van der Waals (vdW) engineering of magnetism is a topic of increasing research interest in the community at present. We study themagnetic properties of quasi-two-dimensional layered vdW Mn 3 Si 2 Te 6 (MST) crystals upon proton irradiation as a function of fluences of 1 × 10 15 , 5 ×10 15 , 1 × 10 16 , and 1 × 10 18 H⁺/cm 2 . We find that the magnetization is significantly enhanced by 53% and 37% in the ferrimagnetic phase (at 50 K) when the MST crystal was irradiated with the proton fluence of 5 ×10 15 , both in ab and c planes, respectively.The ferrimagnetic ordering temperature and magnetic anisotropy are retained even after proton irradiation. From the fluence dependence of magnetization, electron paramagnetic resonance spectral parameters (g-value and signal width), and Raman data, we show that the magnetic exchange interactions (Mn–Te–Mn) are significantly modified at this fluence. This work shows that it is possible to employ protonirradiation in tuning the magnetic properties of vdW crystals and provide many opportunities to design desired magnetic phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

Response of ZrC to swift heavy ion irradiation

Zirconium carbide (ZrC) is commonly used for energy sector research, as well as a surrogate for the proposed advanced nuclear fuel candidate uranium carbide. Here this study investigates structural modifications to nanocrystalline and microcrystalline ZrC resulting from dense electronic excitations induced by swift heavy ion exposure. Samples were irradiated with 946 MeV Au ions to various fluences up to 6 × 10 13 ions cm –2 and characterized using synchrotron-based x-ray diffraction. The evolution of the unit-cell parameter and heterogeneous microstrain were evaluated as a function of fluence and compared with those of nanocrystalline and microcrystalline CeO 2 (a surrogate for UO 2 fuel) irradiated under identical conditions. Distinct differences were observed in the radiation responses of the carbide and oxide across both grain sizes. Most notably, microcrystalline ZrC exhibits swelling characterized by two distinct regimes, which does not result in saturation at the ion fluences achieved. This contrasts with CeO 2 , which exhibits the well-documented direct-impact defect accumulation mechanism, reaching a steady-state saturation of swelling at higher fluences. Nanocrystalline CeO 2 undergoes more pronounced swelling compared with microcrystalline CeO 2 , in contrast to nanocrystalline ZrC, which exhibits only minimal unit-cell changes. These results demonstrate that swift heavy ion-induced structural changes can be quite different in carbides and oxides, which must be considered when extrapolating fission-fragment type damage in current fuels to advanced fuels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of Helium Flux on Near-surface Helium Accumulation in Plasma-Exposed Tungsten

We report results of object kinetic Monte Carlo (OKMC) simulations aimed at understanding the effect of helium flux on the near-surface helium accumulation in plasma-facing tungsten, which is initially defect-free and has a W(100) surface orientation. These OKMC simulations are performed at 933 K for fluxes ranging from 10 22 to 4 × 10 25 He/m 2 s, with 100 eV helium atoms impinging on a W(100) surface up to a maximum fluence of 4×10 19 He/m 2 . In the near-surface region, helium clusters interact elastically with the free surface. The interaction is attractive and results in the drift of mobile helium clusters towards the surface as well as increased trap mutation rates. The associated kinetics and energetics of the above-mentioned processes obtained from molecular dynamics simulations are also considered. The OKMC simulations indicate that as the flux decreases, the retention of implanted helium decreases, and its depth distribution shifts to deeper below the surface in initially pristine tungsten. Furthermore, the fraction of retained helium diffusing into the bulk increases as well, so much so that for 10 22 He/m 2 s, almost all of the retained helium diffused into the bulk with minimal/negligible near-surface helium accumulation. At a given flux, with increasing fluence, the fraction of retained helium initially decreases and then starts to increase after reaching a minimum. The occurrence of the retention minimum shifts to higher fluences as the flux decreases. Although the near-surface helium accumulation spreads deeper into the material with decreasing flux and increasing fluence, the spread appears to saturate at depths between 80 and 100 nm. Finally, we present a detailed analysis of the influence of helium flux on the size and depth distribution of total helium and helium bubbles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symmetry instability induced by topological phase transitions

The symmetry-topology interplay dictates how to define order parameters and classify material ordered phases. However, current understanding of this interplay has been predominately approached from a one-sided perspective, with topological states being classified within the constraints imposed by specific fixed symmetries. Here, in this study, we complete this full circle by demonstrating spontaneous symmetry breaking that results from a periodic alteration of topological phases induced by light in a centrosymmetric Dirac material ZrTe 5 . The distinguishing feature is the observation of robust correlation and striking anomalies in the fluence and temperature dependence of key transport parameters. First, both shift current 𝐽 𝑠 and displacement current 𝐽 𝑑 , arising from interband transition and infrared phonon driving, respectively, along with charge carrier pumping, exhibit similar behaviors. Second, they all peak at similar low pump fluence, followed by a subsequent reduction as the fluence further increases. This behavior cannot be explained by conventional energetically allowed, direct excitations. Third, all the three observables exhibit anomalies when they approach the topological phase transition temperature. These results highlight the unique low-energy pumping behaviors in ZrTe 5 , characterized by reversible fluence dependence and a “hinge-like” interaction that connects various electronic and lattice observables, including phonons, charge carriers, and currents. Our findings, supported by model analysis, provide key insights into the fragility of crystalline (inversion) and time-reversal symmetries during the dynamics of topological phase transitions. This fragility drives spontaneous symmetry breaking, evidenced by the synchronized emergence of off-resonant infrared phonons and broken-symmetry photocurrents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

Integrated structural dynamics uncover new modes of B12 photoreceptor activation

**SACLA** A crystallographic pump-power titration was first carried-out with pump laser fluences of 12, 30, 60 and 120 uJ.cm-2 and a time delay of 3 us. Then, a time-series was performed with a pump-laser fluence of 30 uJ.cm-2 (~2.4 absorbed photon per chromophore) and time-delays of 10 ns, 300 ns, 3 µs, 100 us and 3 ms. Finally, two time-delays (10 ns and 3 us) were collected with a pump laser fluence of 12 uJ.cm-2. Raw images, crystFEL streams and merged mtzs are available for all collected dat **SwissFEL** A time series with a pump laser fluence of 30 mJ.cm-2 was performed at time delys of 3 µs and 10 ms. Raw images, crystFEL streams and merged mtzs are available for all collected datasets. Refined detector geometry for each experimental campaign is also provided (crystFEL format)

RIOS-SANTACRUZ, Ronald↗

Integrated structural dynamics uncover new modes of B12 photoreceptor activation

**SACLA** A crystallographic pump-power titration was first carried-out with pump laser fluences of 12, 30, 60 and 120 ??J.cm-2 and a time delay of 3 ??s. Then, a time-series was performed with a pump-laser fluence of 30 ??J.cm-2 (~2.4 absorbed photon per chromophore) and time-delays of 10 ns, 300 ns, 3 ??s, 100 ??s and 3 ms. Finally, two time-delays (10 ns and 3 ??s) were collected with a pump laser fluence of 12 ??J.cm-2. Raw images, crystFEL streams and merged mtzs are available for all collected dat **SwissFEL** A time series with a pump laser fluence of 30 mJ.cm-2 was performed at time delys of 3 ??s and 10 ms. Raw images, crystFEL streams and merged mtzs are available for all collected datasets. Refined detector geometry for each experimental campaign is also provided (crystFEL format)

RIOS-SANTACRUZ, Ronald↗

Data for "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid"

This repository contains source data for key plots presented in the manuscript "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid." Experimental data that was analyzed in Igor Pro 8 are presented as the .pxp files used to generate individual sub-plots. Electronic spectral function calculations are provided as .txt files, in which consecutive rows refer to the meshgrid x coordinate, y coordinate, spectral function (and, where relevant, axis-projected local angular momentum). We additionally include the Wannier model and DFT-obtained bulk band structure on which the Wannier model was based. Files are named as the number of the figure in the manuscript to which they correspond, with additional details included where necessary. Details of file names: 2a_DOS_Lxz_Ek_KGM_40layer_xnum_800kpt_tot.txt: Density of states, xz-axis projected local orbital angular momentum, for 800 points along the K-Gamma-M path, for a 40-layer model. 2c_composite_y.pxp: ARPES (angle-resolved photoemission spectroscopy) spectra along the ky axis, including both a scan near the Fermi level and a scan at high kinetic energies. 2d_LCP_RCP_diff_Sect_20K.pxp: difference between ARPES constant energy cuts at T=20 K at E0 + 0.23 eV taken with left- and right-circularly polarized photons. The polarization-integrated intensity at the constant energy cut is also included. 2e_DOS_L45_E11pt79_m0pt25to0pt25_xnum_800kpt_tot.txt: Density of states, xz-projected local orbital angular momentum, and corresponding k-points in two dimensions from ab-initio electronic structure calculations for a constant-energy cut. 3a_[x]_[y]ps: ARPES cut under excitation at a fluence of x uJ/cm2, measured y ps after photoexcitation. Measurements were performed at 9 K. 3b_[x]: Energy distribution curves under excitation at a fluence x uJ/cm2 at selected delay times after photoexcitation. 4a_ImSigma_vs_temperature.pxp: Imaginary self energy (extracted from ARPES linewidths) at different energies above E0 for selected lattice temperatures. 4b_EELS_lowE.pxp: Electron energy loss spectrum over a low energy range 5b_diff_55m15.pxp: Difference between momentum-integrated Tr-ARPES traces at 55 uJ/cm2 and 15 uJ/cm2 photoexcitation. Time-dependent intensity at each energy level has been normalized to a maximum of 1 for each individual fluence prior to subtraction. 5d_invtau_at_EX_vs_fluence.pxp: decay rate at a specified energy EX for different excitation fluences, from single exponential fits. NOTE: Analyses based on the Wannier model presented here should cite both the associated Article and this dataset. For all other files in the repository, citing the dataset alone is sufficient.

Acharya, Rishi [University of Illinois] (ORCID:000↗