Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Enhancing Technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

EverGREEN 2045: An Energy Mix to Decarbonize Washington State

Washington State’s future resource mix is likely to be comprised of intermittent renewables and carbon-free generation including hydropower by 2045. Generation will likely be comprised of wind, solar photovoltaic (PV), batteries, pumped storage hydropower (PSH), existing nuclear power plants, and potentially enhanced geothermal systems and advanced nuclear reactor technologies. To assess the cost and stability of the future resource mix, we partner with X-energy (advanced reactor design) and AltaRock Energy (enhanced geothermal system) for proprietary cost data. After estimating the costs of these two new technologies, we design plausible future resource mix scenarios to meet Washington State’s Clean Energy Transformation Act which transitions the state to carbon-free generation by 2045. We assess the cost and stability of the future resource mix with power system analysis tools, finding revenues are sufficient to cover variable operating and maintenance costs for most technologies providing power in 2030 and 2045, but capacity payments or power purchase agreements will likely be necessary for flexible resources, including enhanced geothermal systems and advanced nuclear reactors, to participate in the future resource mix.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

A New Design Consideration for Bidirectional Resonant Converters

This paper introduces innovative design considerations for a bidirectional resonant converter, optimized for Electric Vehicle (EV) charging and vehicle-togrid (V2G) applications. By eliminating the need for complex voltage or current gain functions, the proposed design greatly simplifies the development process, making it more accessible for manufacturers and system integrators. This approach not only reduces engineering time and resource investment but also accelerates time-to-market, giving stakeholders a competitive edge in rapidly expanding EV infrastructure markets. In addition, the streamlined design ensures soft switching at maximum output power, leading to higher efficiency and improved durability, which translates to lower operating costs and a longer service life for EV charging equipment. These benefits provide a clear pathway to more cost-effective, scalable, and sustainable EV charging and V2G solutions, enhancing value for stakeholders by facilitating smoother integration into the grid and supporting energy resilience. To validate the benefits, a 60 kW bidirectional charger with a flexible input range of 700−900VDC and an output range of 400−1250VDC was developed, underscoring the design's adaptability and potential for large-scale implementation.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Improving anaerobic digestion of sewage sludge to renewable natural gas by the Advanced Pretreatment & Anaerobic Digestion technology (APAD): Pilot testing

Conventional anaerobic digestion (AD) of sewage sludge in wastewater treatment facilities suffers from low carbon conversion efficiency (CCE = 40%) and requires costly CO2 removal for injection of the produced CH4 into the natural gas grid. To address these limitations, we developed the Advanced Pretreatment and Anaerobic Digestion (APAD) process. This integrates Advanced Wet Oxidation & Steam Explosion (AWOEx) pretreatment of residual sludge after conventional AD, followed by biogas upgradation using a novel methanogenic strain, Methanothermobacter wolfeii BSEL, converting CO2 with H2 into CH4 or RNG (renewable natural gas). Pilot-scale results demonstrated that AWOEx pretreatment achieved a CCE of 62% for the residual sludge, 68% higher than the conventional AD process. The CH4 production was further increased by 79%. Subsequent biogas upgrading in a trickling bed reactor with H2 further enhanced total methane output by 100% and resulted in a final CO2 concentration of =3%. The integrated APAD process achieved a remarkable overall CCE of 83%, resulting in a 200% increase in RNG output when compared to conventional AD. Techno-economic analysis revealed that AWOEx pretreatment alone reduced sludge treatment costs from $494 to $253 per ton of dry solids. The complete APAD process incurred a higher cost of treatment of $530 per ton, driven by prices for bottled H2. The process did, however, show gains in energy recovery and decarbonization. Renewable H2, which may reduce in price in the near future, can positively improve the economics of biogas upgrading for the APAD process.

Life Cycle Assessment (LCA)↗

Real-Time Simulation of Solid Oxide Electrolyzers (SOEC) for Dynamic Operability Improvement and Cyber-Physical System Development

As more intermittent-renewable generations are being added to the power grid, solid oxide electrolysis cells (SOEC) must enhance their rapid load transition capabilities to load follow and support grid resilience. At NETL, we developed real-time SOEC models to research SOEC transients during load step changes. The gained insights can be useful for dynamic operability improvement. These real-time SOEC models also established the basis for cyber-physical SOEC hybrid energy systems. (Virtual presentation to the 2025 MILLENNIUM CLEAN and SUSTAINABLE POWER workshop, University of Genoa, Italy)

20 FOSSIL-FUELED POWER PLANTS↗

A comprehensive academic and industrial survey of blockchain technology for the energy sector using fuzzy Einstein decision-making

The global energy sector is undergoing a significant transformation driven by decarbonization and digitalization, leading to the emergence of Distributed Ledger Technology (DLT) — particularly blockchain — as a promising tool for enhancing transparency, security, and efficiency in modern power systems. This study aims to provide a comprehensive academic and industrial survey of blockchain applications in the energy sector and develop a robust decision-making framework to identify and prioritize the most promising real-world use cases based on multidisciplinary criteria. A three-stage methodology was adopted: (i) a literature and market review encompassing over 300 academic publications and commercial blockchain initiatives in energy, (ii) an in-depth evaluation of the evolution and viability of blockchain initiatives in energy with the help of expert surveys, and (iii) a novel decision-making model using a q-rung orthopair fuzzy Multi-Attributive Border Approximation (q-ROF-MABAC) method under the Einstein operator. The results were compared with existing decision models to validate consistency and robustness. Nine key blockchain use case categories were identified and ranked based on technical, economic, and governance dimensions. The results demonstrated that integrating expert insights into a fuzzy logic framework helps filter out overhyped claims in the literature and prioritize realistic and high-impact applications such as green certificates, grid services, and peer-to-peer energy trading. The model’s rankings remained stable across varying weight configurations, confirming the robustness of the methodology. This study provides an evidence-based decision-support tool for researchers, industry stakeholders, and policymakers to better understand, evaluate, and adopt blockchain technologies in the energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of ~25% Efficient Double Side Screen Printed Poly-Si/SiO x Passivated Contact Solar Cells

This program aims to overcome these challenges and develop high-efficiency (24-25%) double-side (DS) TOPCon solar cells by maximizing passivation on both sides while mitigating light absorption losses. To achieve this, the program will implement either thin (≤ 20 nm) homogeneous n-TOPCon on the entire front surface or selective area thick (≥ 100 nm) n-TOPCon only underneath the front metal contact with ~90% field region composed of dielectric passivated textured n-Si in between the poly-Si/metal grid. The rear side will feature ~250 nm-thick full-area planar p-TOPCon, which functions as the rear junction. Recombination and parasitic absorption losses in the front and rear TOPCon layers will be minimized by tailoring their doping profiles and thickness. Additionally, the device performance will be further enhanced through the optimization of bulk parameters, including the carrier lifetime, resistivity, and thickness of the n-type Si absorber. Finally, advanced metallization techniques, such as fine-line printing, and floating busbar or busbar-less designs, will be employed to reduce recombination, resistive, and optical losses. The program started with the development of a technology roadmap for DS-TOPCon cells to achieve target efficiency.

14 SOLAR ENERGY↗

Oceanic fronts shape hemispheric contrasts in polar stratospheric extremes

Sudden Stratospheric Warmings (SSWs) and Polar Stratospheric Clouds (PSCs) exhibit striking inter-hemispheric asymmetries: SSWs are frequent in the Arctic but rare in the Antarctic, while PSCs are more persistent in the Antarctic. Although land–sea thermal contrast and orography (LSCO) have been traditionally invoked to explain these asymmetries, here we show using semi-idealized model experiments that even though LSCO strongly impacts the mean state of SSWs and PSCs, it alone cannot fully account for the observed differences. Using model experiments, we reveal that midlatitude oceanic sea surface temperature (SST) fronts represent a crucial supporting additional driver of the hemispheric stratospheric differences. Like LSCO, SST fronts enhance stratospheric convergence of resolved waves, strengthening the Brewer–Dobson Circulation and inducing high-latitude adiabatic warming. This warming significantly enhances Arctic SSW frequency and strongly suppresses PSC formation. Sub-grid-scale non–resolved wave forcing modulates the stratospheric resolved waves effect. The oceanic impact is dominated by North Pacific SST fronts. Our results highlight the indispensable role of SST fronts in shaping Arctic–Antarctic asymmetries in stratospheric dynamics and associated extremes.

Omrani, Nour-Eddine [Univ. of Bergen (Norway)] (OR↗

Connected Residential Communities with Enhanced Resiliency and both Customer and Utility Attributes (Final Technical Report)

This report is a compilation of information from Quarter Progress Reports submitted to the Department of Energy’s Office of Energy Efficiency Building Technologies Office (BTO) by SunPower Corporation. The report has been uploaded to OSTI by DOE as a substitute for the required Final Technical Report which was never received from the project recipient.

14 SOLAR ENERGY↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Deep Cyber-Physical Situational Awareness for Energy Systems: A Secure Foundation for Next-Generation Energy Management

This document provides the final report for the CYPRES project. The purpose is (1) to highlight and summarize its major accomplishments and (2) to provide guidance on how its outcomes have informed and can inform important additional research and technology transfer. The goal of CYPRES was the research, development, and demonstration of a security-oriented next generation cyber-physical EMS for electric power systems that detects malicious and abnormal events through the fusion of cyber and physical data. To achieve this, the CYPRES project team researched, developed, and built a prototype of the solution, referred to as the CYPRES EMS. The CYPRES EMS is a proof-of-concept cyber-physical platform that demonstrates the management of the energy system, communications, security, and cyber-physical grid modeling and analytics. As part of the capabilities of the CYPRES EMS, the team designed and developed a suite of power system applications for monitoring, risk analyses, detection, and control that are inherently cyberaware. At its core, the project aimed to research, develop, and demonstrate a security-oriented next-generation cyber-physical Energy Management System (EMS) capable of detecting malicious and abnormal events through the innovative fusion of cyber and physical data. This approach represents a fundamental shift from traditional EMS, reimagining how critical infrastructure can be protected through unified cyber-aware and physics-aware secure data flow pipelines. The project’s cornerstone deliverable, the CYPRES EMS, serves as a proof-of-concept cyber-physical platform that revolutionizes the management of energy systems, communications, security, and cyber-physical grid modeling and analytics. This prototype implements a comprehensive suite of power system applications for monitoring, risk analyses, detection, and control, all designed with inherent cyber awareness. The system’s architecture extends from end-devices in the field through to control center applications, establishing a secure and resilient control framework that addresses the challenges posed by diverse devices of unknown trustworthiness connecting to modern power systems. Through this innovative approach to deep cyber-physical situational awareness, the CYPRES project not only advances the state-of-the-art in energy infrastructure protection but also establishes a new paradigm for how EMS can be designed, deployed, and operated in an increasingly complex threat landscape. The findings and developments from this project provide crucial insights for stakeholders across the energy sector, offering a blueprint for enhancing the reliability and resilience of our nation’s critical energy infrastructure in the face of evolving cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Enhancing Distribution System Resilience: A First-Order Meta-RL Algorithm for Critical Load Restoration

The increasing frequency of extreme events and the integration of distributed energy resources (DERs) into modern grids have elevated the need for resilient and efficient critical load restoration strategies in distribution systems. However, the stochastic nature of renewable DERs, limited energy resource availability and the intricate nonlinearities inherent in complex grid control problem make the problem challenging. Although reinforcement learning (RL) and warm-start RL methods have shown promising results, their performance often falls short in rapidly adapting to new, unseen situations and typically requires exhaustive problem-specific tuning. To address these gaps, we propose a First-Order Meta-based RL (FOM-RL) algorithm within an online framework for adaptive and robust critical load restoration. By harnessing local DERs as the enabling technology, FOM-RL allows the RL agent to swiftly adapt to new unseen scenarios by leveraging previously acquired knowledge of different tasks. Experimental results provide evidence that proposed algorithm learns more efficiently and showcases generalization capabilities across diverse set of operational scenarios. Moreover, a rigorous theoretical analysis yields a tight sublinear regret bound, sensitive to temporal variability, with a task-averaged optimality gap bounded by O(VM+D*/(Tsquare root(M))). These results suggest that optimality improves with task similarity and an increased number of tasks M, reaffirming the efficacy and scalability of the proposed approach in addressing the complexities of critical load restoration in distribution systems.

complexity theory↗

The Staged, Pressurized Oxy-Combustion Technology: Status and Application to Boiler Retrofits to Yield Carbon-Negative Power via Biomass

Recognizing the benefits of pressurization and fuel staging on the efficiency of oxy-combustion, the staged, pressurized oxy-combustion (SPOC) process was introduced in 2012. The combination of fuel staging and pressurized oxy-combustion results in a more compact plant, a higher plant efficiency and reduced costs for pollutant and greenhouse gas removal compared with plants equipped with conventional carbon capture. This approach to power generation enables a modular boiler design and optimizes the plant for flexible operation, which is essential to meet the demands of the modern grid when it contains intermittent power sources. Originally designed to burn coal, the SPOC process is well-suited for biomass because the combustion of biomass leads to a high moisture content in the flue gas and the SPOC process is able to recover the latent heat of this moisture, enhancing system performance over that of traditional biomass combustion at atmospheric pressure. The present work is focused on evaluating the potential for utilizing the SPOC process in retrofit applications wherein the boilers of an existing plant are replaced with the SPOC process, and woody biomass is used as the fuel to yield carbon-negative power. Two applications are considered: power generation and cogeneration (heat and power). Modeling these systems in Aspen Plus demonstrates that the SPOC process surpasses the performance of baseline plants with post-combustion capture (PCC) for both power generation and cogeneration. Specifically, compared to a PCC equipped plant, the SPOC power plant has 33% higher efficiency, and the SPOC cogeneration plant reaches 42% higher net energy. Experimentally, the existing SPOC facility was fired for the first time with 100% biomass and after minor improvements were made to the feeding system, the facility demonstrated excellent performance during startup, steady-state operation and turndown.

Carbon capture and storage↗

Using AMReX's Embedded Boundaries to Support MFIX-Exa’s Geometry Capabilities

MFIX-Exa is an AMReX-based application used for the simulation of chemically reacting multiphase flows inside reactors. The reactor geometry is mostly a combination of primitive shapes such as cylinders, cubes and spheres of varying dimensions connected together with potentially a lot of dead space between them. Additionally, the reactors may have particle-laden jets introduced at different parts of their geometry to enhance reactant mixing. This talk presents how MFIX-Exa uses OpenSCAD’s csg format to allow users to define the embedded boundary (EB) geometry and how it supports specifying inflow through certain sections of the EB. The talk will describe how MFIX-Exa leverages the EB features of grid-pruning, restart files and redistribution. Finally, the talk goes over some capabilities which are currently not available in MFIX-Exa but planned for the future, such as moving parts of the reactor geometry.

embedded boundaries↗