Search NASA⌕ Search

SEARCH · Search NASA

Results for “HISTOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dosimetric benefits of automation in the treatment of lower thoracic esophageal cancer: Is manual planning still an alternative option?

This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V{sub 5}) for the lung (p = 0.005). For auto-planning, the V{sub 5} of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V{sub 5} of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Importance of deformable image registration and biological dose summation in planning of radiotherapy retreatments

The purpose of this study is to evaluate the effect of nonrigid and fractionation-corrected dose summation on total doses in radiotherapy and to demonstrate the benefits of such dose summation on clinical decision-making for planning of retreatments. Dose summation of organs at risk (OARs) was investigated for 3 clinical cases with need of retreatment to the same site: head and neck, brain, and mediastinum. Three different summation methods over old and new radiotherapy treatment plans are presented and compared: (1) rigid raw sum with rigid registration of the planning images and direct dose summing; (2) deformable raw sum with deformable image registration and direct dose summing; and (3) deformable biological sum with deformable registration and takes into account the dose per fraction in biological manner in certain critical organs. In 2 cases, a user-defined dose downscaling is applied to take into account the time between the treatments and the healing from the radiation-induced effects. Of the 3 summation methods presented, the deformable biological sum was considered to offer the most biologically plausible account of the treatment. There were remarkable differences between near-maximum doses (D0.1cc) and dose-volume histogram (DVH) curves for OARs between different summation methods. The differences between deformable raw sum and rigid raw sum D0.1cc doses are in the range from −8 Gy to 2 Gy. Similarly, the deviation was from −14 Gy to 5 Gy for the deformable biological sum compared with the rigid raw sum. These differences come from incorrect summation of doses in the rigid raw sum case, and from the dose per fraction effect in biological summation. We conclude that computing the 3-dimensional deformable biological summation could be a valuable tool for treating patients with complex retreatments. It has the potential to assist the oncologist in refining plans for maximally curative doses while respecting appropriate tissue tolerances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical analysis of the approximate, 3-dimensional, biological effective dose equation in multiphase treatment plans

A multiphase, approximate biological effective dose (BED{sub A}) equation was introduced because most treatment planning systems (TPS) are incapable of calculating the true BED (BED{sub T}). This work investigates the accuracy and precision of the multiphase BED{sub A} relative to the BED{sub T} in clinical cases. Ten patients with head and neck cancer and 10 patients with prostate cancer were studied using their treatment plans from Pinnacle{sup 3} 9.2 (Philips Medical, Fitchburg, WI). The organs at risk (OARs) that were studied are the normal brain, left and right optic nerves, optic chiasm, spinal cord, brainstem, bladder, and rectum. BED{sub A} and BED{sub T} distributions were calculated using MATLAB 2010b (MathWorks, Natick, MA) and analyzed on a voxel basis for percent error, percent error volume histograms (PEVHs), Pearson correlation coefficient, and Bland-Altman analysis. The maximum BED values that were calculated using the BED{sub A} and BED{sub T} methods were also analyzed. BED{sub A} was found to always underestimate BED{sub T}. The accuracy and precision of BED{sub A} distributions varied between the organs: for optic chiasm and brainstem, 50% of the patients had an overall BED{sub A} percent error of A percent error of A percent error of A distributions had maximum errors ranging from 2% to 11%, with the 11% error occurring for bladder. BED{sub A} produced much more accurate maximum BED values with adjacent organs such as normal brain, bladder, and rectum. This study has shown that BED{sub A} can calculate BED distributions with acceptable accuracy under certain circumstances. However, its consistency and accuracy strongly depend on the dose distributions of the different treatment phases. One should be cautious when using BED{sub A}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing dose variance from immobilization devices in VMAT head and neck treatment planning: A retrospective case study analysis

Immobilization devices serve several purposes in radiation oncology including improved positional reproducibility and decreased patient movement. If immobilization device beam attenuation is unaccounted for in the treatment planning process, planning target volume (PTV) coverage can be compromised. A retrospective case study was performed to evaluate beam attenuation from head and neck (HN) immobilization devices in volumetric-modulated arc therapy using the Eclipse treatment planning system and the Anisotropic Analytical Algorithm. Three facilities retrospectively evaluated 15 patients with various HN carcinomas. A test plan was created from each patient's existing plan in Eclipse to include immobilization devices in the dose calculation. Plan comparisons were performed using dose-volume histograms, which assessed the maximum dose, percentage of the PTV that received 95% of the prescription dose (V{sub 95}), and dose covering 100% of the PTV (D{sub 100}). The test plan normalization values were then adjusted to match the original PTV coverage. The maximum dose difference calculated ranged from 0.3% to 4.1%. The absolute difference in V{sub 95} coverage between the HN and the test plans ranged from 0.4% to 2.3%. The difference in the D{sub 100} was more statistically significant, reporting a range of 1.2% to 71.4%. Finally, to achieve the same PTV coverage as observed in the HN plan, an adjustment to the normalization value was needed, which required a change ranging from 0.1 to 7.7. Attenuation from immobilization devices, when unaccounted for, can cause a misrepresentation of the dose delivered to the PTV. It is not a standardized practice among institutions to include immobilization devices within the body contour for dose calculations. However, with the increasing use of volumetric-modulated arc therapy for treatment of the HN region, precision is of the utmost importance, and inclusion of immobilization devices should be standardized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques

The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V{sub 95%}, V{sub 105%}, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and V{sub XGy}, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p mean and of approximately 5.7% in V{sub 95%} dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in D{sub mean} and V{sub 95%}. IMRT was the best in terms of conformity index and homogeneity index (p 30Gy and V{sub 40Gy} was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V{sub 5%} and V{sub 10%}, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques

The aim of this study is to evaluate the impact of anisotropic analytical algorithm (AAA) and 2 reporting systems (AXB-D{sub m} and AXB-D{sub w}) of Acuros XB algorithm (AXB) on clinical plans of nasopharyngeal patients using intensity-modulated radiotherapy (IMRT) and RapidArc (RA) techniques. Six plans of different algorithm-technique combinations are performed for 10 patients to calculate dose-volume histogram (DVH) physical parameters for planning target volumes (PTVs) and organs at risk (OARs). The number of monitor units (MUs) and calculation time are also determined. Good coverage is reported for all algorithm-technique combination plans without exceeding the tolerance for OARs. Regardless of the algorithm, RA plans persistently reported higher D{sub 2%} values for PTV-70. All IMRT plans reported higher number of MUs (especially with AXB) than did RA plans. AAA-IMRT produced the minimum calculation time of all plans. Major differences between the investigated algorithm-technique combinations are reported only for the number of MUs and calculation time parameters. In terms of these 2 parameters, it is recommended to employ AXB in calculating RA plans and AAA in calculating IMRT plans to achieve minimum calculation times at reduced number of MUs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison between DVH-based doses and ICRU point-based doses to the rectum and the bladder using CT-based high-dose rate brachytherapy to the cervix

Traditionally, doses to the bladder and the rectum were quantified using the bladder and rectal reference points defined by the International Commission on Radiation Units and Measurements (ICRU) in Report No. 38. In this study, we compared the 0.1-, 1.0-, 2.0-cc doses to the bladder and the rectum with the corresponding ICRU point doses using computed tomography (CT)-based planning in the intracavitary brachytherapy of carcinoma of the cervix. CT datasets of 136 consecutive intracavitary brachytherapy insertions between January and May 2015 were analyzed. The bladder and the rectum were contoured on consecutive CT slices as per Groupe Europeen de Curietherapie and the European Socie Ty for Radiotherapy and Oncology recommendations. Dose volume histograms were generated and doses of 0.1, 1.0, and 2.0 cc to the bladder and the rectum were recorded. ICRU bladder and rectal points were identified in the treatment plan. Mean doses of 0.1, 1.0, and 2.0 cc to the bladder was found to be 2.02, 1.57, and 1.35 times the ICRU point dose, respectively. The maximum dose received by the bladder was found to be 5.83 times the average ICRU point dose. Mean doses of 0.1, 1.0, and 2.0 cc to the rectum were found to be 1.12, 0.90, and 0.78 times the ICRU rectal point dose, respectively. The maximum dose received by the rectum was 4.79 times the average ICRU point dose. The Pearson correlation coefficient value (r) was found to be 0.639 for D2cc and ICRU bladder point values. The Pearson correlation coefficient value was found to be 0.752 for D2cc and ICRU rectal point values. Our results show that the ICRU bladder points underestimated the dose to the bladder, which is in agreement with other studies. ICRU rectal point doses were higher than the corresponding D2cc doses. However, there was a good correlation between D2cc and ICRU point doses for both the bladder and the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of body habitus on dose parameters of nodal levels III to IV irradiation for breast cancer: comparison of 3 techniques

This study aimed to investigate the effect of body habitus on supraclavicular (SC) dose-volume histogram (DVH) parameters among breast cancer patients according to 3 different techniques. Three SC irradiation plans were generated for 24 postoperative breast cancer patients: (1) direct antero-posterior field only (1fieldP), with dose prescribed to a 3-cm depth; (2) 3-cm depth plan (3cmP) using an antero-posterior field plus a posterior boost with the dose prescription defined to 3 cm; and (3) optimized plan (OptP) similar to 3cmP, with dose prescribed depending on the anatomy. The OptP plans had the least variation in DVH parameters with body habitus; 3cmP plans were the most varied. Conformity index among normal weight patients were 0.73, 0.78, and 0.87 (p = 0.02) and 0.61, 0.6, and 0.82 among overweight-obese patients for 1fieldP, 3cmP, and OptP, respectively (p 95% of the planning target volume among normal weight patients were 72.63%, 78.03%, and 87.18% for 1fieldP, 3cmP, and OptP, respectively (p = 0.02). The corresponding values among overweight-obese patients were 60.5%, 59.62%, and 81.62%, respectively (p = 0.001). Fixed depth dose prescriptions caused greater SC under dose than plans optimized according to patient's anatomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An in silico comparative dosimetric study of postmastectomy locoregional irradiation using intensity-modulated vs 3-dimensional conventional radiotherapy

An in silico dosimetric evaluation of intensity-modulated radiation therapy (IMRT) vs 3-dimensional conventional radiation therapy (3D-CRT) treatment plans in postmastectomy radiation therapy (PMRT) to the chest wall and regional lymphatics was conducted. Twenty-five consecutive patients with breast cancer referred for locoregional PMRT, stages T{sub 2-4} with N{sub 1-3}, were planned to receive 50 Gy in 25 fractions with IMRT. Additionally, a 3D-CRT plan was generated using identical contours for the clinical target volumes (CTV), planning target volumes (PTV), and organs at risk (OAR). Treatment plans were assessed using dose-volume histogram (DVH) parameters of D{sub 98}, D{sub 95}, D{sub 50}, D{sub 2}, and homogeneity index for individual CTVs and PTVs. OARs evaluated were ipsilateral and contralateral lungs, heart, spinal cord, and opposite breast. Most DVH parameters pertaining to CTVs and PTVs significantly favored IMRT. V{sub 20} for ipsilateral and contralateral lungs, D{sub 33} of heart and maximum dose to spinal cord favored IMRT (all p vs 2.0 ± 1.0 Gy, p < 0.001). Thus, except for the mean dose to the opposite breast, the compliance to DVH constraints applied to PTV and OARs were significantly better with IMRT. At a median follow-up of 76 months (7-91), none had locoregional failure or pulmonary or cardiac morbidity. For PMRT, requiring comprehensive irradiation to both chest wall and regional lymphatics, IMRT offers superior dosimetric advantages over 3D-CRT. This was also corroborated by long-term outcomes in these patients treated with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-volume and radiobiological dependence on the calculation grid size in prostate VMAT planning

This study evaluated the effects of dose-volume and radiobiological dependence on the calculation grid size in prostate volumetric-modulated arc therapy (VMAT) planning. Ten patients with prostate cancer were selected for this retrospective treatment planning study. Prostate VMAT plans were created for the patients using the 6 MV photon beam produced by a Varian TrueBEAM linac with the calculation grid size equal to 1, 2, 2.5, 3, 4, and 5 mm. Dose-volume histograms (DVHs) of targets and organs at risk were generated for different grid sizes. We calculated the radiobiological parameters of the tumor control probability (TCP) of clinical target volume (CTV) and planning target volume (PTV), and the normal tissue complication probability (NTCP) of organs at risk (rectal wall, rectum, bladder wall, bladder, left femur, and right femur). The homogeneity, conformity, and gradient indexes of CTV and PTV were calculated for different grid sizes. The TCP of PTV was found decreasing with a rate of 0.06%/mm when the calculation grid size increased from 1 to 5 mm. On the other hand, both NTCPs of rectal wall and rectum were found decreasing with rates of 0.03%/mm and 0.05%/mm, respectively, with an increase of grid size. The homogeneity index of PTV increased with a rate of 0.57/mm of the calculation grid size, whereas the conformity index of PTV decreased with a rate of 0.0075/mm. The gradient index of PTV was found increasing with a rate equal to 0.05/mm. In prostate VMAT planning, variations of dose-volume and radiobiological parameters with calculation grid size on PTV, rectal wall, and rectum were more significant than those of CTV and other organs at risk such as bladder wall, bladder, and femurs. Results in this study are important in the treatment planning quality assurance when the calculation grid size is varied to compromise a shorter dose computing time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oncentra brachytherapy planning system

In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of several clinical sample cases were discussed to illustrate the effectiveness and clinical efficacy. The American Association of Physicists in Medicine brachytherapy reports of TG-43 and TG-186 were also described and compared in evaluations of fundamental calculation methodologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Object detection with deep learning for rare event search in the GADGET II TPC

In the pursuit of identifying rare two-particle events within the GADGET II Time Projection Chamber (TPC), this paper presents a comprehensive approach for leveraging Convolutional Neural Networks (CNNs) and various data processing methods. To address the inherent complexities of 3D TPC track reconstructions, the data is expressed in 2D projections and 1D quantities. This approach capitalizes on the diverse data modalities of the TPC, allowing for the efficient representation of the distinct features of the 3D events, with no loss in topology uniqueness. Additionally, it leverages the computational efficiency of 2D CNNs and benefits from the extensive availability of pre-trained models. Given the scarcity of real training data for the rare events of interest, simulated events are used to train the models to detect real events. To account for potential distribution shifts when predominantly depending on simulations, significant perturbations are embedded within the simulations. This produces a broad parameter space that works to account for potential physics parameter and detector response variations and uncertainties. These parameter-varied simulations are used to train sensitive 2D CNN object detectors. When combined with 1D histogram peak detection algorithms, this multi-modal detection framework is highly adept at identifying rare, two-particle events in data taken during experiment 21072 at the Facility for Rare Isotope Beams (FRIB), demonstrating a 100% recall for events of interest. Here, we present the methods and outcomes of our investigation and discuss the potential future applications of these techniques.

Convolutional neural network↗

Performance evaluation of the three-point angular correlation function

In recent years, we have observed an increase in the diversity of the processors ecosystem. Different designs and architectures are being studied based on their performance and power characteristics. While using benchmarks for this purpose allows for reproducibility and easy understanding of the results, using real scientific applications allows researchers to realize the actual implications of each design on the overall performance of their codes. This paper analyzes the performance of different implementations of a three-point angular correlation function. This function is used in the study of Large-Scale Distribution of galaxies in a variety of computational platforms. The function is based on histogram construction and presents a large computational cost. This cost dramatically increases with the size of the datasets. We have considered two different GPUs, a set of x86 Intel machines (multi- and many-core), ARM chipsets, as well as an FPGA. We first study the best possible implementation for each platform in terms of time to solution. We then compare the power used by those platforms for a predefined number of datasets. Energy is one of the main constraints that computer architects are facing nowadays. The results will be used to evaluate the performance of this function considering those two targets – time and energy – for those platforms and to analyze the suitability of each of those platforms for this specific problem.

Computer Science↗

Monte Carlo simulations for understanding the transport properties of metallic nanowires

We report the conductance calculation of metallic nanowires of different metals under the application of a tensile force. The elongation induced by the tensile force was simulated by means of the canonical Monte Carlo method combined with the embedded atom method to compute the energy of the system. We studied nanowires composed of Ag, Au, Pt and Cu. The conductance was calculated by means of the Landauer formula and the non-equilibrium Green function formalism. As previously verified experimentally and using other simulation techniques, the conductance is quantized. In addition to this, we have found that there is a strong correlation between the magnitude of the conductance and the width of the nanowire at its thinnest point. Conductance histograms were analyzed for all the different metals.

36 MATERIALS SCIENCE↗